Search NASA⌕ Search

SEARCH · Search NASA

Results for “power sharing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Parametric Comparative Analysis between Virtual Synchronous Generator and Droop-based Inertia for Inverter-Based Microgrids

This paper presents a parametric comparative analysis between the virtual synchronous generator (VSG) method and the droop control method to emulate inertia in the voltage-source inverter (VSI). Droop controllers are commonly used to regulate sharing power in microgrids and distribute power generation proportionally among VSI’s depending on their rated power. Additionally, VSG has been used to regulate the Rate-of-Change-of-Frequency (RoCoF) of the microgrid using virtual inertia. Although both methods can be used to regulate the frequency variation, the influence of each method on the closed loop eigenvalues is not the same. In this work, the transient response of the frequency is analyzed for each method to determine their advantages and disadvantages regarding frequency regulation in microgrid applications. The results were verified by conducting experimental trials using VSI’s. These experiments demonstrated that VSG is more suitable for regulating RoCoF and frequency nadir than droop controllers since it provides inertial support and improves frequency response.

Campo-Ossa, Daniel D.↗

Droop Control-Based Dispatch of an Islanded Microgrid with Multiple Grid-Forming Sources

Before rotating, fossil fuel-based, synchronous generators (SGs) are phased out, in line with renewable generation goals, grid-forming (GFM) inverters are expected to parallel SGs. Primary droop control allows GFM inverters to share power without communication; however, it is necessary to dispatch GFM inverters and/or SGs with the desired output power for better energy management (e.g., one GFM inverter needs to charge the battery due to a low state of charge). Therefore, this paper develops an analytic approach to dispatching GFM inverters and SGs with the desired output power by shifting the droop intercept up/down while maintaining the same frequency operating point for improved transient stability. This concept is demonstrated through a pure hardware setup with two off-the-shelf inverters and one diesel generator under an islanded microgrid, and we provide insight on the real-world implementation of the proposed concept.

droop control↗

Adaptive Reinforcement Learning Control for Power Distribution in Multi-Output Resonant Converters

This paper presents an adaptive reinforcement learning (ARL)-based control framework for efficient power distribution in a multi-output resonant converter for UAV applications. The proposed system is based on a high-frequency isolated resonant architecture, where a single energy source supplies multiple propulsion loads through independently controlled output rectifiers, addressing the need for coordinated multi-motor power management. The ARL framework dynamically allocates output power by learning optimal phase-shift control actions under varying load demands and operating conditions. The agent autonomously determines control parameters that maximize conversion efficiency while ensuring accurate power sharing among multiple outputs. In addition, the proposed approach enables adaptive operation without requiring detailed system modeling or manual tuning. Experimental results demonstrate stable and efficient performance over a wide range of operating conditions, confirming the effectiveness and robustness of the learning-based control strategy for multi-output resonant converter system.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Topology-Agnostic, Scalable, Self-Healing, and Cost-Aware Protection of Microgrids

Most microgrid protection schemes found in published literature suffer from a lack of generality in that they work well for the assumed topology, including type and placement of sources. Other generic protection schemes tend to be too complicated, too expensive, or both. To overcome these draw- backs, a topology-agnostic, scalable, and cost-aware protection based on fundamental principles that work in the presence of high penetration of inverter-based resources (IBRs) is developed and tested in this paper. Here, the protection system also implements stable automatic reconfiguration of the healthy sections of the system after clearance of fault, thus increasing resilience by self- healing. To achieve this ambitious goal, stable inverter models are developed that operate in unbalanced networks in grid-connected and islanded modes, even with 100% IBRs, share power without conflicting controls, and can ride through faults while limiting fault currents. The scheme is tested for primary and backup protection and reconfiguration on the IEEE 123-node feeder in grid-connected and islanded modes with 15 IBRs connected to the system.

42 ENGINEERING↗

Employing Interacting Qubits for Distributed Microgrid Control

To empower flexible and scalable operations, distributed control of multi-inverter microgrids, based on classical communication networks among distributed energy resources, has attracted considerable attention as it can guarantee synchronization and provide suitable remedies to the problem of improper power sharing. Notwithstanding this, resilience of the current schemes on classical communication makes microgrids vulnerable to cyber attacks. Inspired by recent revolutionary breakthroughs in quantum communication, in this paper, we devise a novel synchronization mechanism. We extend the synchronization framework utilized in distributed control algorithms to networks of quantum systems by generating pinning terms and coupling mechanism for the new synchronization rule via exploiting proper quantum jump operators and observables, and show that the quantum system will converge to a time-variant target state. Our devised quantum distributed controller (QDC) gives rise to a novel quantum communication scheme for distributed control of microgrids and enables microgrids to exploit the state-of-the-art quantum communication frameworks as communication infrastructure. Finally, test results on two representative AC and DC networked microgrids validate the efficacy and universality of the quantum distributed control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Evaluation of the Economic and Resilience Benefits of a Microgrid in Northampton, Massachusetts

Recent developments and advances in distributed energy resource (DER) technologies make them valuable assets in microgrids. This paper presents an innovative evaluation framework for microgrid assets to capture economic benefits from various grid and behind-the-meter services in grid-connecting mode and resilience benefits in islanding mode. In particular, a linear programming formulation is used to model different services and DER operational constraints to determine the optimal DER dispatch to maximize economic benefits. For the resiliency analysis, a stochastic evaluation procedure is proposed to explicitly quantify the microgrid survivability against a random outage, considering uncertainties associated with photovoltaic (PV) generation, system load, and distributed generator failures. Optimal coordination strategies are developed to minimize unserved energy and improve system survivability, considering different levels of system connectedness. The proposed framework has been applied to evaluate a proposed microgrid in Northampton, Massachusetts that would link the Northampton Department of Public Works, Cooley Dickenson Hospital, and Smith Vocational Area High School. The findings of this analysis indicate that over a 20-year economic life, a 441 kW/441 kWh battery energy storage system, and 386 kW PV solar array can generate $2.5 million in present value benefits, yielding a 1.16 return on investment ratio. Results of this study also show that forming a microgrid generally improves system survivability, but the resilience performance of individual facilities varies depending on power-sharing strategies.

25 ENERGY STORAGE↗

Development of a ruggedized 20-watt, 2.3- gigahertz transistor

This program was to develop a ruggedized transistor capable of meeting the following CW objectives at 2.3 gigahertz: a power output of 20 watts, a power gain of 6 db, and an efficiency of 40 percent. Devices developed produced the following CW performance at 2.3 gigahertz: a power output of 23 watts, a power gain of 7.7 db, and an efficiently of 40.0 percent. This performance was achieved with an eight-cell TA8407 transistor design having the following modifications: a thin pellet, high-frequency diffusion, high-level emitter ballasting, an optimized emitter-bonding configuration for uniform power sharing, and a package that provides for some internal matching through the use of distributed line techniques.

Source record↗

Development of a breadboard design of a high-performance, high-reliability switching regulator

A comparison of two potential conversion methods, the series inverter and the inductive energy transfer (IET) conversion technique, is presented. The investigations showed that a characteristic of the series inverter circuit (high equalizing current values in each half cycle) could not be accomplished with available components, and the investigations continued with the IET circuit only. An IET circuit system was built with the use of computer-aided design in a 2, 4, and 8 stage configuration, and these stages were staggered 180, 90, and 45 degrees, respectively. All stages were pulsewidth modulated to regulate over an input voltage range from 200 to 400 volts dc at a regulated output voltage of 56 volts. The output power capability was 100 to 500 watts for the 2 and 8 stage configuration and 50 to 250 watts for the 4 stage configuration. Equal control of up to eight 45 degree staggered stages was accomplished through the use of a digital-to-analog control circuit. Equal power sharing of all stages was achieved through a new technique using an inductively coupled balancing circuit. Conclusions are listed.

Lindena, S. J.↗

Electric propulsion: Synergy of orbit transfer and maintenance

Electric propulsion systems for transferring large payload masses to geosynchronous Earth orbits and providing accurate on-orbit stationkeeping are evaluated. Orbit boosting, inclination change, attitude control, stationkeeping, relocation, disposal, and power sharing on orbits using electric propulsion are compared with the use of chemical propulsion.

Zafran, S.↗

Integrated propulsion for near-Earth space missions. Volume 2: Technical

The calculation approach is described for parametric analysis of candidate electric propulsion systems employed in LEO to GEO missions. Occultation relations, atmospheric density effects, and natural radiation effects are presented. A solar cell cover glass tradeoff is performed to determine optimum glass thickness. Solar array and spacecraft pointing strategies are described for low altitude flight and for optimum array illumination during ascent. Mass ratio tradeoffs versus transfer time provide direction for thruster technology improvements. Integrated electric propulsion analysis is performed for orbit boosting, inclination change, attitude control, stationkeeping, repositioning, and disposal functions as well as power sharing with payload on orbit. Comparison with chemical auxiliary propulsion is made to quantify the advantages of integrated propulsion in terms of weight savings and concomittant launch cost savings.

Dailey, C. L.↗

Operation of high power converters in parallel

High power converters that are used in space power subsystems are limited in power handling capability due to component and thermal limitations. For applications, such as Space Station Freedom, where multi-kilowatts of power must be delivered to user loads, parallel operation of converters becomes an attractive option when considering overall power subsystem topologies. TRW developed three different unequal power sharing approaches for parallel operation of converters. These approaches, known as droop, master-slave, and proportional adjustment, are discussed and test results are presented.

Decker, D. K.↗

Teams and teamwork at NASA Langley Research Center

The recent reorganization and shift to managing total quality at the NASA Langley Research Center (LaRC) has placed an increasing emphasis on teams and teamwork in accomplishing day-to-day work activities and long-term projects. The purpose of this research was to review the nature of teams and teamwork at LaRC. Models of team performance and teamwork guided the gathering of information. Current and former team members served as participants; their collective experience reflected membership in over 200 teams at LaRC. The participants responded to a survey of open-ended questions which assessed various aspects of teams and teamwork. The participants also met in a workshop to clarify and elaborate on their responses. The work accomplished by the teams ranged from high-level managerial decision making (e.g., developing plans for LaRC reorganization) to creating scientific proposals (e.g., describing spaceflight projects to be designed, sold, and built). Teams typically had nine members who remained together for six months. Member turnover was around 20 percent; this turnover was attributed to heavy loads of other work assignments and little formal recognition and reward for team membership. Team members usually shared a common and valued goal, but there was not a clear standard (except delivery of a document) for knowing when the goal was achieved. However, members viewed their teams as successful. A major factor in team success was the setting of explicit a priori rules for communication. Task interdependencies between members were not complex (e.g., sharing of meeting notes and ideas about issues), except between members of scientific teams (i.e., reliance on the expertise of others). Thus, coordination of activities usually involved scheduling and attendance of team meetings. The team leader was designated by the team's sponsor. This leader usually shared power and responsibilities with other members, such that team members established their own operating procedures for decision making. Sponsors followed a hands-off policy during team operations, but they approved and reviewed team products. Most teams, particularly high-level decision-making teams, had little or no authority to carry out their decisions. Team members had few interpersonal conflicts. They monitored each other respectfully about meeting deadlines. Feedback and backup behaviors were seen as desirable aspects of teamwork, wanted by the members, and done appropriately.

Dickinson, Terry L.↗

Overview of the Upper Atmosphere Research Satellite: Observations from 1991 to 2002

The Upper Atmosphere Research Satellite (UARS) was launched in September 1991 by the Space Shuttle Discovery. Seven of the original ten instruments aboard the UARS are functional and six instruments regularly take measurements. The UARS is in a stable observing configuration, in spite of experiencing several anomalies which have impacted the data tape storage and power available. Power sharing and "real-time" operations using the Tracking and Data Relay Satellites have reduced the data collection over the past five years. Although the UARS measurements have not been continuous, the UARS instruments HALOE, SUSIM, SOLSTICE, HRDI, WINDII, and PEM have provided important observations over an entire solar cycle. The UARS HALOE instrument measures ozone and other constituents important in understanding ozone variations. The UARS SUSIM and SOLSTICE instruments observe ultraviolet light between 120 and 420 nm, which influence middle atmospheric constituent fluctuations. The UARS HRDI and WINDII instruments measure winds in the stratosphere, mesosphere, and thermosphere, which move constituents among the various atmospheric regions. The UARS PEM instrument provides observations of input precipitating charged particles, including both electrons and protons. This paper will provide an overview about the UARS mission and its relevant atmospheric measurements.

Jackman, Charles H.↗

Incorporation of Nanosensors into Aerospace Vehicles

Traditional sensors are too big and heavy for installation in space vehicles, including the Space Shuttle Orbiter as well as future manned and unmanned vehicles currently in the early design phase. Advances in nanotechnology have led to the availability of smaller and more accurate sensors. Multiple and redundant nanosensors can be used to conduct more accurate and comprehensive measurements in a space vehicle. Early planning can lead to the relatively easy incorporation of miniature sensors sharing power and communication lines, thus reducing the requirement for large amount of electrical and/or optical cabling.

Medelius, Pedro J.↗