Search NASA⌕ Search

SEARCH · Search NASA

Results for “power system regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Frequency Injection Based HVDC Attack-Defense Control Via Squeeze-Excitation Double CNN

Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.

42 ENGINEERING↗

Review of Power System Support Functions for Inverter-Based Distributed Energy Resources - Standards, Control Algorithms, and Trends

Penetration of renewable energy in power systems has been increasing in the past decades in response to increased global electricity demand and concerns for the environment. Distributed energy resources (DERs) based on renewables have experienced rapid growth thanks to the incentive programs and broad-based participation. With the growing prevalence of DERs, the risk of grid instability and vulnerability increases due to the intermittent nature of renewable energy. At the same time, the voltage and frequency deviation problems emerge more often when the reverse power flow occurs under supply-demand imbalance in distributed power systems. Standards and grid codes have been issued for DER inverters to interconnect with the distribution grid. The updated standard and grid codes expect DERs to provide a variety of power system support functions in order to incorporate higher DER penetration and to maximize DER value to the grid. This paper provides an overview of the power system support functions from renewable DER inverters, which are categorized as: voltage regulation by active/reactive power control, frequency regulation by active power control, voltage ride-through, and frequency ride-through. The benefits and drawbacks of each algorithm are presented and compared with its predecessor, manifesting the logic in the evolution of the algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of DER Voltage Regulation Technologies Using Real-Time Simulations

Grid operators are now considering using distributed energy resources (DERs) to provide distribution voltage regulation rather than installing costly voltage regulation hardware. DER devices include multiple adjustable reactive power control functions, so grid operators have the difficult decision of selecting the best operating mode and settings for the DER. In this work, we develop a novel state estimation-based particle swarm optimization (PSO) for distribution voltage regulation using DER-reactive power setpoints and establish a methodology to validate and compare it against alternative DER control technologies (volt–VAR (VV), extremum seeking control (ESC)) in increasingly higher fidelity environments. Distribution system real-time simulations with virtualized and power hardware-in-the-loop (PHIL)-interfaced DER equipment were run to evaluate the implementations and select the best voltage regulation technique. Each method improved the distribution system voltage profile; VV did not reach the global optimum but the PSO and ESC methods optimized the reactive power contributions of multiple DER devices to approach the optimal solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pathways for Tamil Nadu’s Electric Power Sector: 2020 - 2030

This report is part one of a two-part series that represents a year-long collaboration with the Tamil Nadu Generation and Distribution Corporation Limited (TANGEDCO) and Tamil Nadu Transmission Corporation Limited (TANTRANSCO) on power sector planning. This Pathways for Tamil Nadu’s Electric Power Sector 2020-2030 report outlines NREL’s work with TANGEDCO's electricity sector planning department to develop a model of the State power system and evaluate multiple scenarios of system evolution given resource constraints, costs of technologies, and power sector policies. A broad stakeholder group comprised of TANGEDCO leadership, developers, regulators, and researchers from within the power sector community in Tamil Nadu helped to guide the main objectives of the study and provided technical feedback to the research team. The outcomes of this effort include multiple pathways for power sector growth to 2030 and a robust model of Tamil Nadu's power system that can be used to continually analyze the impact of new policies, regulations, or system changes. The second report in this series will build on the bulk system analysis by focusing on the rapidly transforming distribution network in the State. The report will outline a framework developed by NREL and TANGEDCO's distribution utility to quickly and accurately analyze the impacts of integrating renewable energy onto Tamil Nadu's distribution system. Together these studies help to prepare Tamil Nadu for a rapidly transforming power system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regulatory Considerations for Nuclear Energy Applications of Digital Twin Technologies

Digital twins (DTs) in complex industrial and engineering applications have potential benefits that include increased operational efficiencies, enhanced safety and reliability, improved security engineering, reduced errors, faster information sharing, and better predictions. The interest in DT technologies continues to grow, and many of these advanced technologies are expected to experience rapid and wide industry adoption in the near future. Some of the potential application areas for DTs in the nuclear industry are design, licensing, plant construction, training simulators, predictive operations and maintenance, autonomous operation and control, failure and degradation prediction, physical protection modeling and simulation, and safety and reliability analyses. The Office of Nuclear Regulatory Research at the U.S. Nuclear Regulatory Commission (NRC) has initiated a future-focused research project to assess the regulatory viability of DTs for nuclear power plants and other NRC-regulated activities, such as fuel cycle facilities and operations. This report explores the potential impact of DT technologies in nuclear applications on NRC-regulated activities of interest. This report describes a nuclear DT system and its capabilities for nuclear power plant applications, followed by identification and discussion of some regulated activities that merit special consideration and present opportunities in implementing DT-enabling technologies and capabilities.

99 GENERAL AND MISCELLANEOUS↗

Power-to-Gas Systems for Active Load Management at EV Charging Sites with High DER Penetration

Intermittent renewable systems and increasing electric vehicle (EV) penetrations increase load intermittency—and will require expensive distribution system infrastructure upgrades. Power-to-gas (P2G) systems are highly controllable loads that can be modulated to regulate the net load behind the meter. In this work, we present an active load management approach using P2G systems to regulate the net load for an EV charging station with high penetrations of renewable generation. The system also validates the feasibility of the proposed approach using a 750-kW electrolyzer operated with the distribution system in a real-time power-hardware-in-the-loop test. Finally, we evaluate the impact of the size of the P2G system on its ability to regulate the net load.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Electric Vehicles Charging Time Constrained Deliverable Provision of Secondary Frequency Regulation

Aggregation of electric vehicles (EVs) is a promising technique for providing secondary frequency regulation (SFR) in highly renewable energy-penetrated power systems. Equipped with energy storage devices, EV aggregation can provide reliable SFR. However, the main challenge is to guarantee reliable intra-interval SFR capacities and inter-interval delivery following the automatic generation control (AGC) signal. Furthermore, aggregated EV SFR provision will be further complicated by the EV charging time anxiety because SFR provision might extend EV's charging time. This paper proposes a deliverable EV SFR provision with a charging-time-constrained control strategy. First, a charging-time-constrained EV aggregation is proposed to address the uncertainty of EV capacity based on the state-space model considering the charging-time restriction of EV owners. Second, a real-time economic dispatch and time domain simulation (RTED-TDS) cosimulation framework is proposed to verify financial results and the dynamic performance of the EV SFR provision. Last, the proposed charging time-constrained EV aggregation is validated on the IEEE 39-bus system. In conclusion, the results demonstrate that with charging time-constrained EV aggregation, the dynamic performance of the system can be improved with a marginal increase in total cost. More importantly, the charging time constraint can be respected in the proposed SFR provision of the EV aggregation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering↗

Adaptive primal–dual control for distributed energy resource management

With the increased adoption of distributed energy resources (DERs) in distribution networks, their coordinated control with a DER management system (DERMS) that provides grid services (e.g., voltage regulation, virtual power plant) is becoming more necessary. One particular type of DERMS using primal–dual control has recently been found to be very effective at providing multiple grid services among an aggregation of DERs; however, the main parameter, the primal–dual step size, must be manually tuned for the DERMS to be effective, which can take a considerable amount of engineering time and labor. To this end, we design a simple method that self-tunes the step size(s) and adapts it to changing system conditions. Additionally, it gives the DER management operator the ability to prioritize among possibly competing grid services. Here we evaluate the automatic tuning method on a simulation model of a real-world feeder in Colorado with data obtained from an electric utility. Through a variety of scenarios, we demonstrate that the DERMS with automatically and adaptively tuned step sizes provides higher-quality grid services than a DERMS with a manually tuned step size.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Design of Series-connected PV-powered Grid-forming Converters via Singular Perturbation

We report modular architectures that consist of several series-connected dc-ac converters have been a focal point of recent innovations in transformerless medium-voltage applications. In this paper, we consider an architecture consisting of dc-ac modules containing a quadruple active bridge dc-dc converter, which generates three floating dc links that feed grid-side dc-ac inverters. Practical implementation of such a converter module in PV systems requires a variety of controllers that collectively achieve maximum power point tracking, dc-link regulation, and ac-side power control. Design of such multi-loop systems is generally quite challenging due to the potential for destabilizing interactions among loops. Here we propose a design approach where singular perturbation theory is used to decompose the timescales at which each control loop operates and provides a systematic framework for parametric selection. Our approach also ensures system stability of multiple modules with identical controls connected in series across a grid. The paper concludes with experimental results of three 1000 W series-connected converter modules across a stiff grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Primary Frequency Control Using Motor Drives for Short Term Grid Disturbances

Industrial motor systems make up a quarter of all electric sales in the United States. Variable speed drives (VSDs) can provide energy efficiency savings to the customer by regulating motor speed based on specific and varying needs. In addition to the benefits provided to the customer, VSDs can provide support to the grid through ancillary services. The Center for Ultra-Wide-Area Resilient Electric Energy Transmission Networks (CURENT) developed a power electronics converter-based grid emulator to allow testing of various power system architectures and demonstration of key technologies in monitoring, control, actuation, and visualization. This paper proposes using an active front-end VSD's connected motor load to provide frequency regulation to a large scale power grid. Each part of the emulator is described including motor and power electronics model and control. The proposed frequency regulation is implemented in VSDs and modeled in both a transmission system in EMTDC/PSCAD and verified on CURENT's hardware testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Co-Simulation Framework for Steady-State Analyses of Multiple Droop-based MTdc Grids in Continental-Scale Systems

The growing scale and complexity of planning continental hybrid ac and multi-terminal dc (MTdc) systems require scalable steady-state modeling and analysis approaches not currently available in commercial tools. This paper presents a comprehensive multi-fidelity model-conversion framework that enables the efficient transition of MTdc grid models from production cost modeling (PCM) and approximated ac power flow to detailed ac–MTdc power flow for large-scale planning studies. The core of this framework is a scalable co-simulation approach that, for the first time, enables power flow analysis in continental-scale ac–MTdc systems. It seamlessly couples commercial ac solvers with a detailed MTdc grid model that incorporates droop-based control and current-limiting strategies of multiple meshed MTdc grids. Leveraging this capability, an evaluation framework to systematically assess and compare different MTdc power redispatch strategies under ac and dc contingencies is introduced. The proposed framework and algorithm are evaluated using a combined Western and Eastern Interconnection system with 11 MTdc grids of various sizes, showing a coherent transition from PCM to detailed ac–MTdc power flow and improved system performance in voltage regulation and line overload mitigation following typical contingencies.

Nguyen, Quan H.↗

DOE CESER 6 GHz Interference Study

DOE CESER has sponsored Idaho National Laboratory (INL) to conduct an objective and independent study of potential 6 GHz interference from outdoor operation of unlicensed devices in the 6 GHz band on fixed service (FS) microwave communication links operated by electrical sector incumbents in that band. INL is collaborating with University of Notre Dame (UND), Electric Power Research Institute (EPRI), Lockard & White, Southern Company, and AT&T, to gather data with real-world 6 GHz interference experiments and identify (1) the potential for interference from unlicensed devices and (2) the interference necessary to cause harm to the incumbents. In addition to the functional assessment, a security assessment of the FCC mandated Automatic Frequency Coordination (AFC) System to regulate use of unlicensed 6 GHz standard power devices is also being conducted. A major objective is to create a science-based and defensible methodology used to produce the necessary data and to derive objective conclusions. This proven methodology can then be used to produce objective data and conclusions for other spectrum bands with similar incumbent uses including 4.4 – 4.9 GHz and 7.125 – 7.4 GHz, identified in the reconciliation bill that was adopted on July 4, 2025, as well as the National Spectrum Strategy discussions that are ongoing. This report contains 6 GHz field experiments and findings in the following real-world scenarios with commercial unlicensed standard power (SP) 6 GHz devices regulated by Automated Frequency Coordination (AFC): • University of Notre Dame (UND) Stadium with a capacity of 80,000 spectators, where Wi-Fi operating in 6 GHz has been deployed recently • Southern Company 6 GHz FS microwave link between Columbus and Fortson, Georgia Following are the following key findings from this study. 1. The AFC is under-protective of FS when line-of-sight exists along the path centerline. Data collected at Southern’s 6 GHz fixed link site shows significant erosion of as much as 21.4-24.4 dB of under-protection that can lead to potential service degradation under typical operating conditions. This first key finding is most likely the result of erroneous use of the RF propagation model. INL will collaborate with EPRI and the AFC Functional Requirements Working Group to submit a change request to the WinnForum TS-1014 standard towards correct use of the propagation model by the AFC. 2. There is additive interference effect of about 3 dB from nearly equal power interferers measured from simultaneous operation of two SP AP's operating co-channel with the FS receive from different locations along the path. This second key finding should be used to add the impact of additive interference of operation of multiple APs in the same geographical area, to the next generation of AFCs. INL will collaborate with FCC on the need for the AFC to consider additive interference. We also recommend that additional experiments are conducted on 6 GHz spectrum interference to further improve the AFC operation as the number of outdoor Wi-Fi devices continues to increase. These proposed steps and recommendations will make the co-existence of the incumbents and the 6 GHz outdoor Wi-Fi providers possible without any impact on the incumbents with a win-win outcome for all.

6 GHz↗

A Bilevel Voltage Regulation Operation for Distribution Systems With Self-Operated Microgrids

The emerging of microgrids in distribution systems has significantly enhanced the resilience of power grids. However, the operators of a distribution system and microgrids therein can be different and have accessibility to different devices. To model the operation of such a grid, this work proposes a bilevel formulation and probes into the voltage regulation operation, considering the interaction between different systems. The proposed bilevel formulation considers the cooperation of active energy resources (AER), transformer tap-changers, and capacitor banks that are controlled by different operators. To facilitate the solution time of the target bilevel optimization, the lower-level problems with different objectives are modeled using deep neural networks (DNNs) which are then converted into a set of constraints. Hence, the bilevel problem can be reformed to a single-level problem. Lastly, the proposed solution procedures are validated using a customized joint system constructed by the IEEE 123-bus system and a real distribution system in Iowa. According to the numerical validation results, the solution time of the proposed nonlinear activation function based DNN model is 69 times faster than other methods in solving voltage regulation with a bilevel structure.

24 POWER TRANSMISSION AND DISTRIBUTION↗