At least 91 records · Page 5

Automation for Grid Interconnected Laboratory Emulation

As computational capabilities improve, digital twins are becoming vital for evaluating equipment realistically in laboratories. This paper outlines a digital twin architecture for the power grid, employing electromagnetic transient (EMT) simulation alongside real-time simulation of power hardware and hierarchical control systems. EMT simulation occurs on a high-performance computing server for scalability. Additionally, the paper describes a workflow and real-time data streaming software facilitating connectivity among EMT simulation, hierarchical control systems, and power hardware. This software enables automated equipment connectivity in the laboratory for realistic evaluations, aiding in identifying necessary upgrades for both equipment control systems and the power grid.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000

Dynamic analysis of a photovoltaic power system with battery storage capability

A photovolataic power system with a battery storage capability is analyzed. A dual battery current control concept is proposed, which enables the battery to either supply or accept power depending upon system environment and load conditions. A simulation of the power system, including the battery current control, is developed and evaluated. The evaulation demonstrate the visbility of the battery control concept of switch the battery from a charge to discharge mode and back as required by load and environmental conditions. An acceptable system operation is demonstrated over the entire insolation range. Additionally, system sensitivity, bandwidth, and damping characteristics of the battery control are shown to be acceptable for a projected hardware implementation.

Merrill, W. C.

Sonic simulation of the SPS power beam

A Satellite Power System Microwave Transmission Simulator is described. The simulator generates and transmits a beam audible sound energy which is mathematically similar to the microwave beam which would transmit energy to Earth from a Solar Power Satellite. This allows areas such as power beam formation to be studied in a laboratory environment.

Ott, J. H.

Experimental Validation of a Closed Brayton Cycle System Transient Simulation

The Brayton Power Conversion Unit (BPCU) is a closed cycle system with an inert gas working fluid. It is located in Vacuum Facility 6 at NASA Glenn Research Center. Was used in previous solar dynamic technology efforts (SDGTD). Modified to its present configuration by replacing the solar receiver with an electrical resistance heater. The first closed-Brayton-cycle to be coupled with an ion propulsion system. Used to examine mechanical dynamic characteristics and responses. The focus of this work was the validation of a computer model of the BPCU. Model was built using the Closed Cycle System Simulation (CCSS) design and analysis tool. Test conditions were then duplicated in CCSS. Various steady-state points. Transients involving changes in shaft rotational speed and heat input. Testing to date has shown that the BPCU is able to generate meaningful, repeatable data that can be used for computer model validation. Results generated by CCSS demonstrated that the model sufficiently reproduced the thermal transients exhibited by the BPCU system. CCSS was also used to match BPCU steady-state operating points. Cycle temperatures were within 4.1% of the data (most were within 1%). Cycle pressures were all within 3.2%. Error in alternator power (as much as 13.5%) was attributed to uncertainties in the compressor and turbine maps and alternator and bearing loss models. The acquired understanding of the BPCU behavior gives useful insight for improvements to be made to the CCSS model as well as ideas for future testing and possible system modifications.

Johnson, Paul K.

Performance and stability analysis of a photovoltaic power system

The performance and stability characteristics of a 10 kVA photovoltaic power system are studied using linear Bode analysis and a nonlinear analog simulation. Power conversion efficiencies, system stability, and system transient performance results are given for system operation at various levels of solar insolation. Additionally, system operation and the modeling of system components for the purpose of computer simulation are described.

Merrill, W. C.

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays

Rapid ISS Power Availability Simulator

The ISS (International Space Station) Power Resource Officers (PROs) needed a tool to automate the calculation of thousands of ISS power availability simulations used to generate power constraint matrices. Each matrix contains 864 cells, and each cell represents a single power simulation that must be run. The tools available to the flight controllers were very operator intensive and not conducive to rapidly running the thousands of simulations necessary to generate the power constraint data. SOLAR is a Java-based tool that leverages commercial-off-the-shelf software (Satellite Toolkit) and an existing in-house ISS EPS model (SPEED) to rapidly perform thousands of power availability simulations. SOLAR has a very modular architecture and consists of a series of plug-ins that are loosely coupled. The modular architecture of the software allows for the easy replacement of the ISS power system model simulator, re-use of the Satellite Toolkit integration code, and separation of the user interface from the core logic. Satellite Toolkit (STK) is used to generate ISS eclipse and insulation times, solar beta angle, position of the solar arrays over time, and the amount of shadowing on the solar arrays, which is then provided to SPEED to calculate power generation forecasts. The power planning turn-around time is reduced from three months to two weeks (83-percent decrease) using SOLAR, and the amount of PRO power planning support effort is reduced by an estimated 30 percent.

Downing, Nicholas

Longitudinal aerodynamic characteristics of an externally blown flap powered lift model with several propulsive system simulators

An investigation of a four-engine externally blown flap (EBF) powered-lift transport was conducted in the Langley V/STOL tunnel to determine the effect of different engine configurations on the longitudinal aerodynamic characteristics. The different engine configurations were simulated by five different sets of propulsion simulators on a single aircraft model. Longitudinal aerodynamic data were obtained for each simulator on each flap deflection corresponding to cruise, take-off, and landing at a range of angles of attack and various thrust coefficients. The bypass ratio (BPR) 6.2 engine simulator provided the best lift and drag characteristics of the five simulators tested in the take-off and landing configurations. The poor performance of the BPR 10.0 and 3.2 engine simulators can be attributed to a mismatch of engine-model sizes or poor engine location and orientation. Isolated engine wake surveys indicated that a reasonable assessment of the aerodynamic characteristics of an engine-wing-flap configuration could be made if qualitative information were available which defined the engine wake characteristics. All configurations could be trimmed easily with relatively small horizontal-tail incidence angles; however, the take-off landing configurations required a high-lift tail.

Hoad, D. R.

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS

Laboratory Evaluation of Federated, Hierarchical Controls for Distribution Power System Management: Preprint

The connection of more loads and distributed energy resources (DERs) to the distribution power system brings both challenges and opportunities to system operators. There are opportunities to aggregate flexible loads and DERs to provide transmission grid services, but the coordinated actions of DERs being managed by independent, third-party DER aggregators to support transmission system operations can present challenges. We developed a federated DER management architecture and control framework that aims to manage heterogeneous DERs to deliver reliable transmission grid services while respecting distribution system constraints. The controls include stochastic day-ahead optimization, model predictive control, and a simple real-time management scheme. We present simulation results obtained from a realistic laboratory test bed of federated controls managing DERs within a substation service area to make the substation net power follow the optimal net power determined by the day-ahead optimization based on cost and limiting reverse power flow.

24 POWER TRANSMISSION AND DISTRIBUTION

Computer program analyzes and monitors electrical power systems (POSIMO)

Requirements to monitor and/or simulate electric power distribution, power balance, and charge budget are discussed. Computer program to analyze power system and generate set of characteristic power system data is described. Application to status indicators to denote different exclusive conditions is presented.

Jaeger, K.

Real-time microcomputer simulation for space Shuttle/Centaur avionics

The design of a simulator system for emulating the characteristics of Shuttle/Centaur avionic support equipment for launching the Solar Polar Mission and the Galileo probe are discussed. The simulators are being constructed on a modular basis for the Centaur control avionics, the Centaur Airborne Support Equipment avionics, the tanking skid ground support equipment, development mechanisms, the tanking skid ground support equipment, deployment mechanisms, the tanking onboard fluid functions, the star scanner guidance update avionics, the Orbiter command interface avionics, and the Orbiter power system. Each simulator portrays the actual working conditions, including signal delay times and harnessing. Block diagrams are provided of the interfaces and a flow diagram is presented of the software.

Szatkowski, G. P.

Development and Integration of a Thermal Management Simulation for a Quadrotor Parallel Hybrid Propulsion System

This paper details the development of a propulsion system simulation for a six-passenger parallel hybrid quadrotor and utilizes the Numerical Propulsion System Simulation (NPSS) along with the NPSS Power System Library as the development environment. This simulation integrates an engine power plant with an electrical generation and distribution system and includes the required thermal management system. The thermal management system is comprised of liquid cooling loops that reject the heat load through air to coolant heat exchangers and utilizes a map-based performance estimation method. This method is developed within NPSS and detailed in this paper. The full system model is designed to predict system weight, range, and performance through a proposed mission profile. Results of the paper show an all-engine system maintains the best range, while a mostly electric system that utilizes an engine as a backup or a conditional power contributor offers range benefit.

Vertical lift and take off vehicle

Development and Integration of a Thermal Management Simulation for a Quadrotor Parallel Hybrid Propulsion System

This paper details the development of a propulsion system simulation for a six-passenger parallel hybrid quadrotor and utilizes the Numerical Propulsion System Simulation (NPSS) along with the NPSS Power System Library as the development environment. This simulation integrates an engine power plant with an electrical generation and distribution system and includes the required thermal management system. The thermal management system is comprised of liquid cooling loops that reject the heat load through air to coolant heat exchangers and utilizes a map-based performance estimation method. This method is developed within NPSS and detailed in this paper. The full system model is designed to predict system weight, range, and performance through a proposed mission profile. Results of the paper show an all-engine system maintains the best range, while a mostly electric system that utilizes an engine as a backup or a conditional power contributor offers range benefit.

Vertical lift and take off vehicle

Impact of Reordering on the LU Factorization Performance of Bordered Block-Diagonal Sparse Matrix

Power engineers rely on computer-based simulation tools to assess grid performance and ensure security. At the core of these tools are solvers for sparse linear equations. When transformed into a bordered block-diagonal (BBD) structure, part of the sparse linear equation solving can be parallelized. This work focuses on using the Schur-complement-based method for LU factorization on BBD matrices, specifically, Jacobian matrices from large-scale systems. Our findings show that the natural ordering method outperforms the default ordering method in computational performance for each block of the BBD matrix. This observation is validated using synthetic 25k-bus and 70k-bus cases, showing a speedup of up to 38% when using natural ordering without permutation. Additionally, the impact of the number of partitions is studied, and the result shows that computational performance improves with more, smaller partitions in the BBD matrices.

BBD matrix

Impact of Hydrological Data on Power System Operational Studies: Preprint

Hydropower is expected to play an important role in maintaining grid reliability and flexibility as the share of of variable renewable energy increases. While the current hydropower operational models have been studied and used widely, they haven't been updated for decades to meet new performance standards. For example, current steady state and dynamic models often neglect hydrological conditions, which may lead to unrealistic expectations when relying on hydropower for energy and ancillary services. To study this impact, a multi-timescale hydrological model was created by leveraging the National Renewable Energy Laboratory-developed Multi-timescale Integrated Dynamics and Scheduling (MIDAS) tool. Using MIDAS, we compare the impact of considering hydrological conditions in a day-ahead unit commitment (DAUC) schedule on the reduced 240-bus Western Interconnect (WI) test system under winter and summer case studies. We show that neglecting current hydrological conditions of hydropower plants in power system models can lead to an overestimation of hydropower capabilities, which could lead to power balancing issues. For example, power system DAUC simulation results of our reduced test system show that in the case where hydrological conditions are not considered in the model, an approximate 31% overestimation of hydropower capabilities occurs in the summer case and approximately 60% occurs in the winter case compared to what is available. Additionally, results show an underestimation of WI day-ahead power system generation costs by approximately $54M - $80M in the weekly summer scenario and $116M - $126M in the weekly winter scenario. This analysis helps to underscore the importance of considering hydrological data in power system operational studies.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY

Experimental Validation of a Closed Brayton Cycle System Transient Simulation

The Brayton Power Conversion Unit (BPCU) located at NASA Glenn Research Center (GRC) in Cleveland, Ohio was used to validate the results of a computational code known as Closed Cycle System Simulation (CCSS). Conversion system thermal transient behavior was the focus of this validation. The BPCU was operated at various steady state points and then subjected to transient changes involving shaft rotational speed and thermal energy input. These conditions were then duplicated in CCSS. Validation of the CCSS BPCU model provides confidence in developing future Brayton power system performance predictions, and helps to guide high power Brayton technology development.

Johnson, Paul K.