Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision cleaning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

In response to the elimination of production of several Ozone Depleting Chemicals (ODCs) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-Free cleaning procedures. One leg of that philosophy is the initiation of a several tier testing program which will deliver increasing amounts of information over the next few years, starting with original surface analysis comparisons between ODC and various ODC-Free cleaning technologies. The other leg is the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years with a number of important tribological questions unanswered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life mechanism based on a number of parameters, including a comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODCs based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

Predmore, Roamer↗

The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

In response to the elimination of production of several Ozone Depleting Chemicals (ODC's) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-free cleaning procedures. The short term leg of the philosophy was the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. The long-term leg of that philosophy was the initiation of a several tier testing program that will deliver increasing amounts of information over the next few years, starting with accelerated lubricant life tests that compare lubricant life on surfaces cleaned with ODC solvents with lubricant life on surfaces cleaned with ODC-free solvents. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years before a number of important tribological questions can be answered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life lubricated mechanism based on a number of parameters, including 4 comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODC's based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

Predmore, Roamer↗

Prospects for exploring non-standard neutrino properties with argon-based CEvNS experiments

Coherent elastic neutrino-nucleus scattering (CEvNS) provides a powerful frame-work for testing the Standard Model (SM) and searching for new physics at low energies. In this work, we examine the prospects for argon-based CEvNS experiments at stopped-pion sources to perform precision measurements of weak interactions and probe non-standard neutrino properties. Our study focused on the CENNS-10 and CENNS-750 detectors at the Spallation Neutron Source at Oak Ridge National Laboratory, the Coherent Captain Mills (CCM) detector at Los Alamos National Laboratory, and the proposed PIP2-BD detector at Fermilab’s Facility for Dark Matter Discovery (F2D2). Using realistic neutrino fluxes and detector configurations corresponding to these facilities, we evaluate event rates and sensitivities to a range of observables. Within the SM, argon-based CEvNS detectors enable precision tests of electroweak parameters, including the weak mixing angle, at momentum transfers well below the electroweak scale. We also investigate the sensitivity of these experiments to neutrino electromagnetic properties, such as the magnetic moment and effective charge radius, as well as to possible non-standard neutrino interactions with quarks. Together, these studies highlight the potential of argon-based CEvNS experiments as a clean and versatile platform for precision exploration of non-standard neutrino properties.

Carey, Sam [Wayne State U.] (ORCID:000900029607531↗

Deterministic Fabrication of Large-Area, High-Crystallinity Oxide Moiré Superlattices

Oxide twistronics extends moiré engineering beyond van der Waals materials, offering a promising platform for accessing emergent interfacial phenomena arising from the strong coupling of lattice, charge, and orbital degrees of freedom in complex oxides. However, deterministic fabrication of high-crystallinity oxide moiré superlattices over large lateral dimensions remains challenging due to the three-dimensional bonding network of oxides. Here, we demonstrate a scalable, generalized fabrication strategy that enables the formation of high-crystallinity oxide moiré superlattices with clean, chemically bonded interfaces and precisely controlled twist angles down to nominal values of 0.1°, achieving subdegree twist-angle accuracy across large contiguous lateral dimensions approaching the millimeter scale. Using NaNbO3 as a model system, we show that the resulting interlayer coupling drives pronounced structural reconstruction that modifies both the phase structure and ferroelectric domain configuration. Synchrotron-based X-ray 3D reciprocal space mapping reveals the emergence of a single-phase state in twisted bilayers, in contrast to the mixed-phase structure observed in single-layer membranes prior to twist assembly. The structural signatures are further consistent with gradual lattice rotation distributed along the thickness direction that may accommodate interfacial shear strain, distinct from reconstruction observed in van der Waals moiré systems which primarily occurs through in-plane stacking rearrangement. This collective lattice response is correlated with twist-dependent nanoscale electromechanical modulations observed by piezoresponse force microscopy. These results establish a scalable materials platform for oxide twistronics and support the implementation of twist-engineered functionalities in practical, macroscale device architectures.

Ghanbari, Reza [North Carolina State University (N↗

Rhenium in seawater - Confirmation of generally conservative behavior

A depth profile of the concentration of Re was measured in the Pacific Ocean using a technique developed for the clean chemical separation and the precise measurement of Re by isotope dilution and negative thermal ionization mass spectrometry (ID-NTIMS). We obtain a narrow range for Re from 7.20 +/- 0.03 to 7.38 +/- 0.03 ng/kg for depths between 45 m and 4700 m. This demonstrates that Re is relatively well mixed throughout the water column and confirms the theoretical prediction that the behavior of Re in the oceans is conservative. When examined in detail, both salinity and the concentration of Re increase by approximately 1.5 percent between 400 and 4700 m, a correlation consistent with conservative behavior. However, Re appears to be depleted relative to salinity by 1.0-1.5 percent at 100 m, and enriched by approximately 4 percent at the surface. These observations suggest a minor level of Re scavenging in near surface waters, and an input of Re to the ocean surface. This work demonstrates the utility of geochemical investigations of certain trace elements not previously been amenable to detailed study.

Anbar, A. D.↗

Development of CFC-Free Cleaning Processes at the NASA White Sands Test Facility

The NASA White Sands Test Facility (WSTF) is developing cleaning and verification processes to replace currently used chlorofluorocarbon-113- (CFC-113-) based processes. The processes being evaluated include both aqueous- and solvent-based techniques. The presentation will include the findings of investigations of aqueous cleaning and verification processes that are based on a draft of a proposed NASA Kennedy Space Center (KSC) cleaning procedure. Verification testing with known contaminants, such as hydraulic fluid and commonly used oils, established correlations between nonvolatile residue and CFC-113. Recoveries ranged from 35 to 60 percent of theoretical. WSTF is also investigating enhancements to aqueous sampling for organics and particulates. Although aqueous alternatives have been identified for several processes, a need still exists for nonaqueous solvent cleaning, such as the cleaning and cleanliness verification of gauges used for oxygen service. The cleaning effectiveness of tetrachloroethylene (PCE), trichloroethylene (TCE), ethanol, hydrochlorofluorocarbon-225 (HCFC-225), tert-butylmethylether, and n-Hexane was evaluated using aerospace gauges and precision instruments and then compared to the cleaning effectiveness of CFC-113. Solvents considered for use in oxygen systems were also tested for oxygen compatibility using high-pressure oxygen autoignition and liquid oxygen mechanical impact testing.

Beeson, Harold↗

Clean Electrical-Discharge Machining Of Delicate Honeycomb

Precise recesses in fragile metal honeycomb blocks formed in special electrical-discharge machining process. Special tooling used, and recesses bored with workpiece in nonstandard alignment. Cutting electrode advances into workpiece along x axis to form pocket of rectangular cross section. Deionized water flows from fitting, along honeycomb tubes of workpiece, to electrode/workpiece interface.

Johnson, Clarence S.↗

Perturbative Stability and Error-Correction Thresholds of Quantum Codes

Topologically ordered phases are stable to local perturbations, and topological quantum error-correcting codes enjoy thresholds to local errors. We connect the two notions of stability by constructing classical statistical mechanics models for decoding general Calderbank-Shor-Steane codes and classical linear codes. Our construction encodes correction success probabilities under uncorrelated bit-flip and phase-flip errors, and simultaneously describes a generalized ℤ 2 lattice-gauge theory with quenched disorder. We observe that the clean limit of the latter is precisely the discretized imaginary-time path integral of the corresponding quantum code Hamiltonian when the errors are turned into a perturbative 𝑋 or 𝑍 magnetic field. Motivated by error-correction considerations, we define general order parameters for all such generalized ℤ 2 lattice-gauge theories, and show that they are generally lower bounded by success probabilities of error correction. For CSS codes satisfying the low-density parity-check condition and with a sufficiently large code distance, we prove the existence of a low-temperature ordered phase of the corresponding lattice-gauge theories, particularly for those lacking Euclidean spatial locality and/or when there is a nonzero code rate. We further argue that these results provide evidence for stable phases in the corresponding perturbed quantum Hamiltonians, obtained in the limit of continuous imaginary time. To do so, we distinguish space- and timelike defects in the lattice-gauge theory. A high free-energy cost of spacelike defects corresponds to a successful “memory experiment” and suppresses the energy splitting among the ground states, while a high free-energy cost of timelike defects corresponds to a successful “stability experiment” and points to a nonzero gap to local excitations.

quantum error correction↗

Laser Surface Preparation and Bonding of Aerospace Structural Composites

Adhesive bonds are critical to the integrity of built-up structures. Disbonds can often be detected but the strength of adhesion between surfaces in contact is not obtainable without destructive testing. Typically the number one problem in a bonded structure is surface contamination, and by extension, surface preparation. Standard surface preparation techniques, including grit blasting, manual abrasion, and peel ply, are not ideal because of variations in their application. Etching of carbon fiber reinforced plastic (CFRP) panels using a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser appears to be a highly precise and promising way to both clean a composite surface prior to bonding and provide a bond-promoting patterned surface akin to peel ply without the inherent drawbacks from the same (i.e., debris and curvature). CFRP surfaces prepared using laser patterns conducive to adhesive bonding were compared to typical prebonding surface treatments through optical microscopy, contact angle goniometry, and post-bonding mechanical testing.

Belcher, M. A.↗

Laser Surface Preparation for Adhesive Bonding of Aerospace Structural Composites

Adhesive bonds are critical to the integrity of built-up structures. Disbonds can often be detected but the strength of adhesion between surfaces in contact is not obtainable without destructive testing. Typically the number one problem in a bonded structure is surface contamination, and by extension, surface preparation. Standard surface preparation techniques, including grit blasting, manual abrasion, and peel ply, are not ideal because of variations in their application. Etching of carbon fiber reinforced plastic (CFRP) panels using a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser appears to be a highly precise and promising way to both clean a composite surface prior to bonding and provide a bond-promoting patterned surface akin to peel ply without the inherent drawbacks from the same (i.e., debris and curvature). CFRP surfaces prepared using laser patterns conducive to adhesive bonding were compared to typical pre-bonding surface treatments through optical microscopy, contact angle goniometry, and post-bonding mechanical testing.

Belcher, M. A.↗

Toll-Booth Purification

NASA's Technology Application Team at Stanford Research Institute searched available information and suggested a transfer of clean-room technology employing the use of the same laminar flow techniques found in environmental control systems of clean rooms used for contamination-free assembly of precision aerospace equipment. That information, from technology originally developed by NASA and the Energy Research & Development Administration was incorporated in the design of a prototype toll booth purifier. The draft-free design includes a "diffusor", which blows clean air out the toll booth doorway, thus retarding the infiltration of contaminated air. The net effect is a decrease in the toll collector's inhalation of exhaust fumes. The Washington Department of Highways installed the prototype system in a toll booth at the Evergreen Point Bridge near Seattle. After a successful two-year test, the department now has equipped all 10 of the bridge's toll booths with the air purifiers.

Source record↗

A Reduced-Temperature Process for Preparing Atomically Clean Si(100) and SiGe(100) Surfaces with Vapor HF

Silicon processing techniques such as atomic precision advanced manufacturing (APAM) and epitaxial growth require surface preparations that activate oxide desorption (typically >1000 °C) and promote surface reconstruction toward atomically clean, flat, and ordered Si(100)-2 × 1. Here, in this study, we compare the aqueous and vapor phase cleaning of Si and Si/SiGe surfaces to prepare APAM-ready and epitaxy-ready surfaces at lower temperatures. Angle resolved X-ray photoelectron spectroscopy (ARXPS) and Fourier transform infrared (FTIR) spectroscopy indicate that vapor hydrogen fluoride (VHF) cleans dramatically reduce carbon surface contamination and allow the chemically prepared surface to reconstruct at lower temperatures, 600 °C for Si and 580 °C for a Si/Si 0.7 Ge 0.3 heterostructure, into an ordered atomic terrace structure indicated by scanning tunneling microscopy (STM). After thermal treatment and vacuum hydrogen termination, we demonstrate STM hydrogen desorption lithography (HDL) on VHF-treated Si samples, creating reactive zones that enable area-selective chemistry by using a thermal budget similar to CMOS process flows. We anticipate that these results will establish new pathways to integrate APAM with Si foundry processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum mechatronics

The discipline of vacuum mechatronics is defined as the design and development of vacuum-compatible computer-controlled mechanisms for manipulating, sensing and testing in a vacuum environment. The importance of vacuum mechatronics is growing with an increased application of vacuum in space studies and in manufacturing for material processing, medicine, microelectronics, emission studies, lyophylisation, freeze drying and packaging. The quickly developing field of vacuum mechatronics will also be the driving force for the realization of an advanced era of totally enclosed clean manufacturing cells. High technology manufacturing has increasingly demanding requirements for precision manipulation, in situ process monitoring and contamination-free environments. To remove the contamination problems associated with human workers, the tendency in many manufacturing processes is to move towards total automation. This will become a requirement in the near future for e.g., microelectronics manufacturing. Automation in ultra-clean manufacturing environments is evolving into the concept of self-contained and fully enclosed manufacturing. A Self Contained Automated Robotic Factory (SCARF) is being developed as a flexible research facility for totally enclosed manufacturing. The construction and successful operation of a SCARF will provide a novel, flexible, self-contained, clean, vacuum manufacturing environment. SCARF also requires very high reliability and intelligent control. The trends in vacuum mechatronics and some of the key research issues are reviewed.

Hackwood, Susan↗

It's a Clean Machine

Under an SBIR (Small Business Innovative Research) from Lewis Research Center, Precision Combustion, Inc. (PCI) developed the Advanced Technology Catalytic Combustor. The research proved the viability of efficient, cost-effective catalytic reduction of gas turbine nitrogen oxide emissions along with fuel efficiency. PCI has signed agreements with Westinghouse, other gas turbine manufacturers, including Capstone Turbine Corporation to develop a catalytic combustor for their hybrid electric vehicle.

Source record↗

Repurposing the James Webb Space Telescope’s center of curvature optical bench hexapod for future mirror calibration testing at NASA Marshall’s x-ray & cryogenic facility

The James Webb Space Telescope’s (JWST) center of curvature optical bench (CoCOB) hexapod was repurposed to enhance NASA Marshall Space Flight Center’s X-Ray & Cryogenic Facility (XRCF) optical metrology capabilities. This upgrade unlocked higher test article load capacity and extended the allowable ranges of motion of the CoCOB hexapod. The hexapod was also coupled to a new long-stroke, linear motion axis to form a 7 degrees of freedom system and allow for high precision testing of larger diameter test articles. A 9 degrees of freedom motion system, consisting of a three-axis linear mount in an X-Y-Z configuration and a commercially available hexapod, was also designed to allow high resolution positioning of the focal plane instrumentation over a large range of motion. A modern control architecture and graphical user interface was developed for the CoCOB hexapod and additional motion stages to permit streamlined commanding and operation. This paper discusses the justification for re-using the CoCOB hexapod by highlighting its unique precision motion control capabilities in a high vacuum and optically clean environment. The design, key component selection, and environmental compatibility for each of the additional motion stages is presented along with testing results for achieved range, repeatability, and minimum step size performance for all motion axes. Finally, a summary of the motion control system architecture and its flexibility to address tomorrow’s optical metrology needs are presented.

hexapod↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surface of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The six commonly used methods for establishing objective cleanliness acceptance limits will be discussed. Special emphasis shall focus on the use of multiple extraction, a technique that has been demonstrated for additively manufactured parts.

Welker, Roger W.↗

Cleaning and Cleanliness Measurement of Additive Manufactured Parts

The successful acquisition and utilization of piece parts and assemblies for contamination sensitive applications requires application of cleanliness acceptance criteria. Contamination can be classified using many different schemes. One common scheme is classification as organic, ionic and particulate contaminants. These may be present in and on the surface of solid components and assemblies or may be dispersed in various gaseous or liquid media. This discussion will focus on insoluble particle contamination on the surfaces of piece parts and assemblies. Cleanliness of parts can be controlled using two strategies, referred to as gross cleanliness and precision cleanliness. Under a gross cleanliness strategy acceptance is based on visual cleanliness. This approach introduces a number of concerns that render it unsuitable for controlling cleanliness of high technology products. Under the precision cleanliness strategy, subjective, visual assessment of cleanliness is replaced by objective measurement of cleanliness. When a precision cleanliness strategy is adopted there naturally arises the question: How clean is clean enough? The methods for establishing objective cleanliness acceptance limits will be discussed.

Mitchell, Mark A.↗

Prospects for Probing Strong Gravity with a Pulsar-Black Hole System

The discovery of a pulsar (PSR) in orbit around a black hole (BH) is expected to provide a superb new probe of relativistic gravity and BH properties. Apart from a precise mass measurement for the BH, one could expect a clean verification of the dragging of space-time caused by the BH spin. In order to measure the quadrupole moment of the BH for testing the no-hair theorem of general relativity (GR), one has to hope for a sufficiently massive BH. In this respect, a PSR orbiting the super-massive BH in the center of our Galaxy would be the ultimate laboratory for gravity tests with PSRs. But even for gravity theories that predict the same properties for BHs as GR, a PSR-BH system would constitute an excellent test system, due to the high grade of asymmetry in the strong field properties of these two components. Here we highlight some of the potential gravity tests that one could expect from different PSR-BH systems.

gravity↗