Search NASA⌕ Search

SEARCH · Search NASA

Results for “prelaunch characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ares I-X Range Safety Flight Envelope Analysis

Ares I-X was the first test flight of NASA's Constellation Program's Ares I Crew Launch Vehicle designed to provide manned access to low Earth orbit. As a one-time test flight, the Air Force's 45th Space Wing required a series of Range Safety analysis data products to be developed for the specified launch date and mission trajectory prior to granting flight approval on the Eastern Range. The range safety data package is required to ensure that the public, launch area, and launch complex personnel and resources are provided with an acceptable level of safety and that all aspects of prelaunch and launch operations adhere to applicable public laws. The analysis data products, defined in the Air Force Space Command Manual 91-710, Volume 2, consisted of a nominal trajectory, three sigma trajectory envelopes, stage impact footprints, acoustic intensity contours, trajectory turn angles resulting from potential vehicle malfunctions (including flight software failures), characterization of potential debris, and debris impact footprints. These data products were developed under the auspices of the Constellation's Program Launch Constellation Range Safety Panel and its Range Safety Trajectory Working Group with the intent of beginning the framework for the operational vehicle data products and providing programmatic review and oversight. A multi-center NASA team in conjunction with the 45th Space Wing, collaborated within the Trajectory Working Group forum to define the data product development processes, performed the analyses necessary to generate the data products, and performed independent verification and validation of the data products. This paper outlines the Range Safety data requirements and provides an overview of the processes established to develop both the data products and the individual analyses used to develop the data products, and it summarizes the results of the analyses required for the Ares I-X launch.

Starr, Brett R.↗

SeaWiFS Technical Report Series. Volume 22: Prelaunch Acceptance Report for the SeaWiFS Radiometer

The final acceptance, or rejection, of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) will be determined by the instrument's on-orbit operation. There is, however, an extensive set of laboratory measurements describing the operating characteristics of the radiometer. Many of the requirements in the Ocean Color Data Mission (OCDM) specifications can be checked only by laboratory measurements. Here, the calibration review panel examines the laboratory characterization and calibration of SeaWiFS in the light of the OCDM performance specification. Overall, the performance of the SeaWiFS instrument meets or exceeds the requirements of the OCDM contract in all but a few unimportant details. The detailed results of this examination are presented here by following the outline of the specifications, as found in the Contract. The results are presented in the form of requirements and compliance pairs. These results give conclusions on many, but not all, of the performance specifications. The acceptance by this panel of the performance of SeaWiFS must only be considered as an intermediate conclusion. The ultimate acceptance (or rejection) of the SeaWiFS data set will rely on the measurements made by the instrument on orbit.

Hooker, Stanford B.↗

Characterization of NPP Visible/Infrared Imager Radiometer Suite (VIIRS) Reflective Solar Bands Dual Gain Anomaly

The Visible/Infrared Imager Radiometer Suite (VIIRS) contains six dual gain bands in the reflective solar spectrum. The dual gain bands are designed to switch gain mode at pre-defined thresholds to achieve high resolution at low radiances while maintaining the required dynamic range for science. During pre-launch testing, an anomaly in the electronic response before transitioning from high to low gain was discovered and characterized. On-orbit, the anomaly was confirmed using MODIS data collected during Simultaneous Nadir Overpasses (SNOs). The analysis of the Earth scene data shows that dual gain anomaly can be determined at the orbital basis. To characterize the dual gain anomaly, the anomaly region and electronic offsets were tracked per week during the first 8 month of VIIRS operation. The temporal analysis shows the anomaly region can drift ~20 DN and is impacted by detectors DC Restore. The estimated anomaly flagging regions cover ~2.5 % of the high gain dynamic range and are consistent with prelaunch and on-orbit LUT. The prelaunch results had a smaller anomaly range (30-50 DN) and are likely the results of more stable electronics from the shorter data collection time. Finally, this study suggests future calibration efforts to focus on the anomaly's impact on science products and possible correction method to reduce uncertainties.

Lee, Shihyan↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

SeaWiFS technical report series. Volume 22: Prelaunch acceptance report for the SeaWFS radiometer

The final acceptance, or rejection, of the Sea-viewing Wide field-of-view Sensor (SeaWiFS) will be determined by the instrument's on-orbit operation. There is, however, an extensive set of laboratory measurements describing the operating characteristics of the radiometer. Many of the requirements in the Ocean Color Data Mission (OCDM) specifications can be checked only by laboratory measurements. Here, the calibration review panel (composed of the authors of this technical memorandum) examines the laboratory characterization and calibration of SeaWiFS in the light of the OCDM performance specification. Overall, the performance of the SeaWiFS instrument meets or exceeds the requirements of the OCDM contract in all but a few unimportant details. The detailed results of this examination are presented here by following the outline of the specifications, as found in the Contract. The results are presented in the form of requirements and compliance pairs. These results give conclusions on many, but not all, of the performance specifications. The acceptance of this panel of the performance of SeaWiFS must only be considered as an intermediate conclusion. The ultimate acceptance (or rejection) of the SeaWiFS data set will rely on the measurements made by the instrument on orbit.

Hooker, Stanford B.↗

Thermal band characterization of LANDSAT-4 thematic mapper

The TM band 6 shutter background and the 34.7 C internal black body signal were measured over 50 day dates. Variability of the shutter background temperature was from 7 C to 11 C. For ten specific images, the digital counts of the calibration data were measured. The average pulse value of the black body peak decreased from 174 to 149 counts while the shutter background counts varied as a function of shutter temperature from 77 to 85. Relative internal gains between the four channels were calculated and compared to prelaunch values. They showed gains over 9 months of up to 5%. Frequency histograms of number of pixels vs. digital counts from a night scene were used to determine gain relative to the mean and to discern a systematic along-scan pattern in a difference between forward and reverse scan counts of up to 0.5. A corrected digital image was obtained. A temperature estimate for and area of Lake Erie of 18.5 C to 19.9 C was obtained. Local temperature records showed 21 C.

Lansing, J. C.↗

Analyzing the Impacts of Natural Environments on Launch and Landing Availability for NASA's Eploration Systems Development Programs

NASA is developing new capabilities for human and scientific exploration beyond Earth orbit. Natural environments information is an important asset for NASA's development of the next generation space transportation system as part of the Exploration Systems Development Program, which includes the Space Launch System (SLS) and MultiPurpose Crew Vehicle (MPCV) Programs. Natural terrestrial environment conditions - such as wind, lightning and sea states - can affect vehicle safety and performance during multiple mission phases ranging from prelaunch ground processing to landing and recovery operations, including all potential abort scenarios. Space vehicles are particularly sensitive to these environments during the launch/ascent and the entry/landing phases of mission operations. The Marshall Space Flight Center (MSFC) Natural Environments Branch provides engineering design support for NASA space vehicle projects and programs by providing design engineers and mission planners with natural environments definitions as well as performing custom analyses to help characterize the impacts the natural environment may have on vehicle performance. One such analysis involves assessing the impact of natural environments to operational availability. Climatological time series of operational surface weather observations are used to calculate probabilities of meeting or exceeding various sets of hypothetical vehicle-specific parametric constraint thresholds.

Altino, Karen M.↗

Transmittal of Geotail Prelaunch Mission Operation Report

Geotail is an element in the International Solar Terrestrial Physics (ISTP) Program. The overall goal of the ISTP Program is to employ simultaneous and closely coordinated remote observations of the sun and in situ observations both in the undisturbed heliosphere near Earth and in Earth s magnetosphere to measure, model, and quantitatively assess the processes in the sun/Earth interaction chain. In the early phase of the Program, simultaneous measurements in the key regions of geospace from Geotail and the two U.S. satellites of the Global Geospace Science (GGS) Program, Wind and Polar, along with equatorial measurements, will be used to characterize global energy transfer.

Source record↗

STS-102 Expedition 2 Increment and Science Briefing

Merri Sanchez, Expedition 2 Increment Manager, John Uri, Increment Scientist, and Lybrease Woodard, Lead Payload Operations Director, give an overview of the upcoming activities and objectives of the Expedition 2's (E2's) mission in this prelaunch press conference. Ms. Sanchez describes the crew rotation of Expedition 1 to E2, the timeline E2 will follow during their stay on the International Space Station (ISS), and the various flights going to the ISS and what each will bring to ISS. Mr. Uri gives details on the on-board experiments that will take place on the ISS in the fields of microgravity research, commercial, earth, life, and space sciences (such as radiation characterization, H-reflex, colloids formation and interaction, protein crystal growth, plant growth, fermentation in microgravity, etc.). He also gives details on the scientific facilities to be used (laboratory racks and equipment such as the human torso facsimile or 'phantom torso'). Ms. Woodard gives an overview of Marshall Flight Center's role in the mission. Computerized simulations show the installation of the Space Station Remote Manipulator System (SSRMS) onto the ISS and the installation of the airlock using SSRMS. Live footage shows the interior of the ISS, including crew living quarters, the Progress Module, and the Destiny Laboratory. The three then answer questions from the press.

Source record↗

Measurement of the Earth-Observer-1 Satellite X-Band Phased Array

The recent launch and successful orbiting of the EO-1 Satellite has provided an opportunity to validate the performance of a newly developed X-Band transmit-only phased array aboard the satellite. This paper will compare results of planar near-field testing before and after spacecraft installation as well as on-orbit pattern characterization. The transmit-only array is used as a high data rate antenna for relaying scientific data from the satellite to earth stations. The antenna contains distributed solid-state amplifiers behind each antenna element that cannot be monitored except for radiation pattern measurements. A unique portable planar near-field scanner allows both radiation pattern measurements and also diagnostics of array aperture distribution before and after environmental testing over the ground-integration and prelaunch testing of the satellite. The antenna beam scanning software was confirmed from actual pattern measurements of the scanned beam positions during the spacecraft assembly testing. The scanned radiation patterns on-orbit were compared to the near-field patterns made before launch to confirm the antenna performance. The near-field measurement scanner has provided a versatile testing method for satellite high gain data-link antennas.

Perko, Kenneth↗

ACTS Multibeam Communications Package - Description and Performance Characterization

To maintain its competitive position in the 1990s, satellite communications must evolve to provide new services and to reduce the costs of supplying existing services. NASA's Advanced Communications Technology Satellite (ACTS) program is directed toward developing the technology base that will support this evolution. The ACTS communications payload is optimized for digital communications using a time-division multiple-access format. Scanning spot-beam antennas provide high-performance, on-demand service to communications earth stations. On-board processing and switching allow full connectivity in a single-hop network architecture. ACTS employs Ka-Band (30/20 GHz) links for communications traffic and includes techniques for mitigating rain fades. The prelaunch test program has verified that all critical payload performance requirements have been realized, including G/T, EIRP, beam coverage, AM/AM, AM/PM, and BER vs. E(b)/N(o). Scheduled to be launched by a Space Shuttle in 1993, ACTS will provide in-orbit technology verification and support experimental communications networks for up to four years.

Cashman, William F.↗

STS-76 Flight Day 1

On this first day of the STS-76 mission, the flight crew, Cmdr. Kevin P. Chilton, Pilot Richard A Searfoss, and Mission Specialists Shannon W. Lucid, Linda M. Godwin, Michael R. Clifford, and Ronald M. Sega, are shown performing prelaunch and launch activities for the night launch of the Space Shuttle Atlantis. The primary objective of this mission is the third docking between the Mir Space Station and Atlantis and a crew transfer. Lucid will remain onboard the Mir for about four months. Other activities include an EVA by Godwin and Clifford, logistics operations, and scientific research with a SPACEHAB module, some middeck experiments, and a Get Away Special (GAS) canister. Also, almost a ton of equipment and supplies will be transferred to the Mir. Experiments include the Mir Electric Field Characterization (MEFC), European Space Agency (ESA) Biorack life sciences experiment, Queens University Experiment in Liquid Diffusion (QUELD), Optizone Liquid Phase Sintering Experiment (OLIPSE), and a Naval Research Laboratory (NRL) GAS payload Trapped Ions in Space (TRIS), which will measure low-energy particle radiation in the inner magnetosphere. This mission also will include a KidSat, a prototype of Earth viewing cameras and instruments, that allow students in grades K-12 to see and direct the capture of pictures from space. Footage from Mission control is also included.

Source record↗

Measured space environmental effects to LDEF during retrieval

The Interim Operational Contamination Monitor (IOCM) is an attached shuttle payload to the Long Duration Exposure Facility (LDEF) that was used on 2 earlier flights to quantify the contamination deposited during the course of the missions. The IOCM can characterize by direct measurement the deposition of molecular and particulate contamination during any phase of flight. Also, the IOCM actively measures the optical property changes of thermal control surfaces by calorimetry, the flux of the ambient atomic oxygen environment, the incident solar flux, and the absolute ambient pressure in the payload bay. The IOCM also provides a structure and sample holders for the exposure of passive material samples to the space environment, e.g., thermal cycling, atomic oxygen, and micrometeoroids and/or debris. Some of the more salient results from the flight suggests that the payload bay was slightly contaminated during both the prelaunch phase of the mission and after the deployment of the SYNCOM IV payload. Measurements during the postflight phases, i.e., ferry flight and deintegration processing, show negligible to very low mass deposition. The results of the data are discussed in depth.

Maag, Carl R.↗

HALOE Science Investigation

This cooperative agreement has investigated a number of spectroscopic problems of interest to the Halogen Occultation Experiment (HALOE). The types of studies performed are in two parts, namely, those that involve the testing and characterization of correlation spectrometers and those that provide basic molecular spectroscopic information. In addition, some solar studies were performed with the calibration data returned by HALOE from orbit. In order to accomplish this a software package was written as part of this cooperative agreement. The HALOE spectroscopic instrument package was used in various tests of the HALOE flight instrument. These included the spectral response test, the early stages of the gas response test and various spectral response tests of the detectors and optical elements of the instruments. Considerable effort was also expended upon the proper laboratory setup for many of the prelaunch tests of the HALOE flight instrument, including the spectral response test and the gas response test. These tests provided the calibration and the assurance that the calibration was performed correctly.

Benner, D. Chris↗

Uncertainties for Pre- and Post-Launch Radiometric Calibration of Imaging Spectrometers for Multi-Sensor Applications

An important aspect to using imaging spectrometer data is the radiometric characterization and calibration of the sensors and validation of their data products and doing so with error budgets with known traceability. The radiometric accuracy of a given sensor is important for demonstrating the expected quality of data from the sensor. Known traceability allows data from multiple sensors to be directly comparable as will become more important in the near future with the expected launches of multiple imaging spectrometers from multiple countries, agencies, and commercial entities. The current work describes the state of pre- and post-launch radiometric absolute and relative uncertainties and their role in harmonising on-orbit data. Examples of prelaunch uncertainties based on the calibration of EnMAP and the calibration planned for the CLARREO Pathfinder Mission are presented highlighting recent work in the area of detector-based approaches using tunable laser sources. Post-launch calibration approaches for Pathfinder, EnMAP, CHIME, and DESIS including traditional vicarious calibration methods and the challenges of working with commercial data are presented. The vicarious calibration discussion relies on the example of the recently-available RadCalNet data to describe typical methods and challenges that will be faced when harmonising data between imaging spectrometers as well as with multispectral sensors.

Thome, K.↗

Aqua MODIS Thermal Emissive Band On-Orbit Calibration, Characterization, and Performance

The NASA's Earth Observing System Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) has continued to operate with satisfactory performance since its launch in May 2002, exceeding its nominal six-year design lifetime. Its continuous Earth observations have been used to generate many science data products for studies of the Earth's, system. MODIS has 36 spectral bands; 20 reflective solar bands and 16 thermal emissive bands (TEBs). All TEB observations are made at 1-km nadir spatial resolution with spectral wavelengths from 3.7 to 14.4 pm. Primary applications of MODIS TEB 'include surface, cloud, and atmospheric temperatures, water vapor, and cloud top altitude. MODIS TEB on-orbit calibration uses a quadratic algorithm with its calibration coefficients derived using an onboard blackbody (BB). This paper will present Aqua MODIS TEB on-orbit calibration, characterization, and performance over its six-year mission. Examples of instrument thermal behavior, BB temperature stability, detector short-term stability, and changes in long-term response (or system gain) will be presented. Comparisons will also be made with Terra MODIS, launched in December 1999. On-orbit results show that Aqua MODIS and its focal plane temperatures have behaved normally. BB temperature has remained extremely stable with typical scan -to-scan variations of less than +/-0.15 mK. Most TEB detectors continue to exceed their specified signal-to-noise ratio requirements, exhibiting excellent short-term stability and calibration accuracy. Excluding a few noisy detectors, either identified prelaunch or occurring postlaunch, on-orbit changes in TEB responses have been less than 0.5% on an annual basis. By comparison; the overall Aqua TEB performance has been better than that of Terra MODIS,

Xiong, Xiaoxiong↗

Landsat-7 EMT+ On-Orbit Radiometric Calibration

Landsat-7 was launched on April 15, 1999 and completed its on orbit initialization and verification period on June 28, 1999. The ETM+ payload is similar to the TM sensors on previous Landsat satellites and incorporates two new devices to improve its absolute radiometric calibration. The Full Aperture Solar Calibrator (FASC) is a deployable diffuser panel. This device has been deployed 9 times to date, with a normal deployment schedule of once per month. The initial analysis of the FASC data has given absolute calibration results within 5% of the prelaunch integrating sphere calibrations and a range of variation of 2% between dates. The Partial Aperture Solar Calibrator (PASC), is a set of auxiliary optics that allows the ETM+ to view the sun through a reduced aperture. Data have normally been acquired on a daily basis with the PASC. Initial results with the PASC were encouraging, despite some unexpected saturation in the shortest wavelength band. The response of the ETM+ short wavelength (silicon) bands to the PASC increased initially and has begun to decrease in some of these bands. The longer wavelength (InSb) bands have shown up to 30% oscillations that vary between detectors within the band. Studies are ongoing to better characterize the response to the PASC. The ETM+ also incorporates an internal calibrator (IC), a shutter that oscillates in front of the focal plane that directs light from the internal calibrator lamps to the focal plane. The responses to this device are also varying, though differently than the PASC results. Both the IC and PASC results are attributable to the calibration devices as opposed to the ETM+ itself.

Markham, Brian L.↗

SeaWiFS Postlaunch Technical Report Series: The 1997 Prelaunch Radiometric Calibration of SeaWiFS - Volume 4

The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) was originally calibrated by the instrument's manufacturer, Santa Barbara Research Center (SBRC), in November 1993. In preparation for an August 1997 launch, the SeaWiFS Project and the National Institute of Standards and Technology (NIST) undertook a second calibration of SeaWiFS in January and April 1997 at the facility of the spacecraft integrator, Orbital Sciences Corporation (OSC). This calibration occurred in two phases, the first after the final thermal vacuum test, and the second after the final vibration test of the spacecraft. For the calibration, SeaWiFS observed an integrating sphere from the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at four radiance levels. The spectral radiance of the sphere at these radiance levels was also measured by the SeaWiFS Transfer Radiometer (SXR). In addition, during the calibration, SeaWiFS and the SXR observed the sphere at 16 radiance levels to determine the linearity of the SeaWiFS response. As part of the calibration analysis, the GSFC sphere was also characterized using a GSFC spectroradiometer. The 1997 calibration agrees with the initial 1993 calibration to within +/- 4%. The new calibration coefficients, computed before and after the vibration test, agree to within 0.5%. The response of the SeaWiFS channels in each band is linear to better than 1%. In order to compare to previous and current methods, the SeaWiFS radiometric responses are presented in two ways: using the nominal center wave-lengths for the eight bands; and using band-averaged spectral radiances. The band-averaged values are used in the flight calibration table. An uncertainty analysis for the calibration coefficients is also presented.

Hooker, Stanford B.↗