Search NASA⌕ Search

SEARCH · Search NASA

Results for “preparation methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sorbents for the oxidation and removal of mercury

A promoted activated carbon sorbent is described that is highly effective for the removal of mercury from flue gas streams. The sorbent comprises a new modified carbon form containing reactive forms of halogen and halides. Optional components may be added to increase reactivity and mercury capacity. These may be added directly with the sorbent, or to the flue gas to enhance sorbent performance and/or mercury capture. Mercury removal efficiencies obtained exceed conventional methods. The sorbent can be regenerated and reused. Sorbent treatment and preparation methods are also described. New methods for in-flight preparation, introduction, and control of the active sorbent into the mercury contaminated gas stream are described.

Olson, Edwin S.↗

Pd-CeO 2 catalyst facilely derived from one-pot generated Pd@Ce-BTC for low temperature CO oxidation

Due to the capacity to offer abundant catalytic sites within porous solids featuring high surface areas, metal-organic frameworks (MOFs) and their derivatives have garnered considerable attention as prospective catalysts in environmental catalysis. Here, to promote the industrial application of MOFs, there is an urgent need for an effective and environmental-friendly preparation approach. Breaking through the limitation of the traditional two-step preparation method that Pd was introduced to the already prepared Ce-BTC (Pd/Ce-BTC, BTC = 1, 3, 5 benzenetricarboxylate), in this work, we present a novel one-pot solvothermal method for synthesizing the Pd material supported by Ce-BTC (Pd@Ce-BTC). After pyrolysis in N 2 flow or air flow, Pd-CeO 2 catalysts derived from Pd@Ce-BTC exhibited much higher CO oxidation activity than those from Pd/Ce-BTC. Moreover, Pd/Ce-BTC and Pd@Ce-BTC pyrolyzed in N 2 flow (Pd/Ce-BTC-N and Pd@Ce-BTC-N) could better catalyze the oxidation of CO than Pd/Ce-BTC and Pd@Ce-BTC pyrolyzed in air flow (Pd/Ce-BTC-A and Pd@Ce-BTC-A). Further characterizations revealed that the abundant surface Ce 3+ species, rich surface adsorbed oxygen species and superior redox properties were the main reasons for the superior CO oxidation activity of Pd@Ce-BTC-N.

36 MATERIALS SCIENCE↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

UO 2 target preparation with spin coating assisted solution combustion synthesis

A simple and efficient target preparation method is developed combining spin coating and solution combustion synthesis. Multiple smooth and uniform UO 2 targets have been prepared using this method on a variety of backings (aluminium, carbon, silicon) used in nuclear physics experiments. The thicknesses of the targets can be precisely tuned by changing the number of coatings within the range of ~50-1000 µm/cm 2 . These targets are highly uniform (<5% deviation), robust, and remain strongly adherent to their backings even after being irradiated by high doses (10 17 ions/ cm 2 ) of 1.7 MeV Ar 2+ ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Surface Finishing and Coating Parameters Impact on Additively Manufactured Binder-Jetted Steel–Bronze Composites

In this paper, electroless nickel plating is explored for the protection of binder-jetting-based additively manufactured (AM) composite materials. Electroless nickel plating was attempted on binder-jetted composites composed of stainless steel and bronze, resulting in differences in the physicochemical properties. We investigated the impact of surface finishing, plating solution chemistry, and plating parameters to attain a wide range of surface morphologies and roughness levels. We employed the Keyence microscope to quantitatively evaluate dramatically different surface properties before and after the coating of AM composites. Scanning electron microscopy revealed a wide range of microstructural properties in relation to each combination of surface finishing and coating parameters. We studied chempolishing, plasma cleaning, and organic cleaning as the surface preparation methods prior to coating. We found that surface preparation dictated the surface roughness. Taguchi statistical analysis was performed to investigate the relative strength of experimental factors and interconnectedness among process parameters to attain optimum coating qualities. The quantitative impacts of phosphorous level, temperature, surface preparation, and time factor on the roughness of the nickel-plated surface were 17.95%, 8.2%, 50.02%, and 13.21%, respectively. On the other hand, the quantitative impacts of phosphorous level, temperature, surface preparation, and time factor on the thickness of nickel plating were 35.12%, 41.40%, 3.87%, and 18.24%, respectively. The optimum combination of the factors’ level projected the lowest roughness of Ra at 7.76 µm. The optimum combination of the factors’ level projected the maximum achievable thickness of ~149 µm. This paper provides insights into coating process for overcoming the sensitivity of AM composites in hazardous application spaces via robust coating.

36 MATERIALS SCIENCE↗

Robust surfactant-assisted one-pot sample preparation for label-free single-cell and nanoscale proteomics

With advanced mass spectrometry (MS)-based proteomics, genome-scale proteome coverage can be achieved from bulk cells. However, such bulk measurement obscures cell to cell heterogeneity, precluding proteome profiling of single cells and small numbers of cells of interest. To address this issue, in recent 5 years there are a surge of small sample preparation methods developed for robust effective collection and processing of single cells and small numbers of cells for in-depth MS-based proteome profiling. Based on their broad accessibility, they can be categorized into two types: specific device- and standard PCR tube- or multi-well plate-based methods. Herein we describe the detailed protocol of our recently developed, easily adoptable, Surfactant-assisted One-Pot (SOP) sample preparation coupled with MS method termed SOP-MS for label-free single-cell and nanoscale proteomics. SOP-MS capitalizes on the combination of a MS-compatible surfactant, DDM (n-Dodecyl-ß-D-maltoside), and standard low-bind PCR tube or multi-well plate for ‘all-in-one’ one-pot sample preparation without sample transfer. With its robust and convenient features, SOP-MS can be readily implemented in any MS laboratory for single-cell and nanoscale proteomics. With further improvements in MS detection sensitivity and sample throughput, we believe that SOP-MS could open an avenue for single-cell proteomics with broad applicability in the biological and biomedical research.

Single-cell proteomics, nanoscale proteomics, SOP-↗

Application of a headspace GC–MS method to evaluate the product quality of alcohol‐based hand wipe sanitizers

Abstract The investigation of marketed hand wipe sanitizers presented an analytical challenge owing to the need for extraction from the solid matrix of the products. The present work describes the development of a new sample preparation method for the extraction of analytes from the hand wipe sanitizer matrix into dimethyl sulfoxide for analysis using headspace GCMS. Alcohol‐based hand sanitizer (ABHS) wipe products labeled to contain ethanol or isopropanol as active ingredients were tested, varying in the size and weight of the wipes. The spike recovery assay was confirmed using spiking solutions containing impurities at concentrations equivalent to 50, 100 and 200% of the interim concentration limits. All of the tested analytes showed recovery within the allowable limits (80–120%). Six marketed ABHS wipe products were tested and no impurities above the FDA interim limits were observed. One product contained ethanol below the 60% v/v limit and another product was mislabeled for isopropanol and was found to contain ethanol instead. Four of the six ABHS products did not meet the label claim, which may affect the product quality. The analytical method and sample preparation procedures will provide the FDA and ABHS manufacturers with the capability to conduct quality assurance testing of hand wipe sanitizers for active ingredient content and impurities.

Biochemistry & Molecular Biology↗

A Tip-based Workflow for Sensitive IMAC-based Low Nanogram Level Phosphoproteomics

Analyzing the phosphoproteome at nanoscale poses a significant challenge, mainly due to the substantial sample loss from non-specific surface adsorption during the enrichment of low stoichiometric phosphopeptides. Here, we describe a tandem tip-based phosphoproteomics sample preparation method capable of sequential sample cleanup and enrichment without the need for additional sample transfer, thereby minimizing sample loss. Integration of this method to our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches creates a streamlined workflow, enabling sensitive, high-throughput nanoscale phosphoproteomics measurements.

Phosphoproteome, Immobilized metal ion affinity ch↗

X-ray fluorescence microscopy methods for biological tissues

Abstract Synchrotron-based X-ray fluorescence microscopy is a flexible tool for identifying the distribution of trace elements in biological specimens across a broad range of sample sizes. The technique is not particularly limited by sample type and can be performed on ancient fossils, fixed or fresh tissue specimens, and in some cases even live tissue and live cells can be studied. The technique can also be expanded to provide chemical specificity to elemental maps, either at individual points of interest in a map or across a large field of view. While virtually any sample type can be characterized with X-ray fluorescence microscopy, common biological sample preparation methods (often borrowed from other fields, such as histology) can lead to unforeseen pitfalls, resulting in altered element distributions and concentrations. A general overview of sample preparation and data-acquisition methods for X-ray fluorescence microscopy is presented, along with outlining the general approach for applying this technique to a new field of investigation for prospective new users. Considerations for improving data acquisition and quality are reviewed as well as the effects of sample preparation, with a particular focus on soft tissues. The effects of common sample pretreatment steps as well as the underlying factors that govern which, and to what extent, specific elements are likely to be altered are reviewed along with common artifacts observed in X-ray fluorescence microscopy data.

Pushie, M. Jake (ORCID:0000000174945427)↗

Mass Spectral Imaging to Map Plant–Microbe Interactions

Plant–microbe interactions are of rising interest in plant sustainability, biomass production, plant biology, and systems biology. These interactions have been a challenge to detect until recent advancements in mass spectrometry imaging. Plants and microbes interact in four main regions within the plant, the rhizosphere, endosphere, phyllosphere, and spermosphere. This mini review covers the challenges within investigations of plant and microbe interactions. We highlight the importance of sample preparation and comparisons among time-of-flight secondary ion mass spectroscopy (ToF-SIMS), matrix-assisted laser desorption/ionization (MALDI), laser desorption ionization (LDI/LDPI), and desorption electrospray ionization (DESI) techniques used for the analysis of these interactions. Using mass spectral imaging (MSI) to study plants and microbes offers advantages in understanding microbe and host interactions at the molecular level with single-cell and community communication information. More research utilizing MSI has emerged in the past several years. We first introduce the principles of major MSI techniques that have been employed in the research of microorganisms. An overview of proper sample preparation methods is offered as a prerequisite for successful MSI analysis. Traditionally, dried or cryogenically prepared, frozen samples have been used; however, they do not provide a true representation of the bacterial biofilms compared to living cell analysis and chemical imaging. New developments such as microfluidic devices that can be used under a vacuum are highly desirable for the application of MSI techniques, such as ToF-SIMS, because they have a subcellular spatial resolution to map and image plant and microbe interactions, including the potential to elucidate metabolic pathways and cell-to-cell interactions. Promising results due to recent MSI advancements in the past five years are selected and highlighted. The latest developments utilizing machine learning are captured as an important outlook for maximal output using MSI to study microorganisms.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Microbial Community Characterization of 16S rRNA via Metagenome Hybridization Capture Enrichment

Environmental microbial diversity is often investigated from a molecular perspective using 16S ribosomal RNA (rRNA) gene amplicons and shotgun metagenomics. While amplicon methods are fast, low-cost, and have curated reference databases, they can suffer from amplification bias and are limited in genomic scope. In contrast, shotgun metagenomic methods sample more genomic regions with fewer sequence acquisition biases, but are much more expensive (even with moderate sequencing depth) and computationally challenging. Here, we develop a set of 16S rRNA sequence capture baits that offer a potential middle ground with the advantages from both approaches for investigating microbial communities. These baits cover the diversity of all 16S rRNA sequences available in the Greengenes (v. 13.5) database, with no sequence having <78% sequence identity to at least one bait for all segments of 16S. The use of our baits provide comparable results to 16S amplicon libraries and shotgun metagenomic libraries when assigning taxonomic units from 16S sequences within the metagenomic reads. We demonstrate that 16S rRNA capture baits can be used on a range of microbial samples (i.e., mock communities and rodent fecal samples) to increase the proportion of 16S rRNA sequences (average > 400-fold) and decrease analysis time to obtain consistent community assessments. Furthermore, our study reveals that bioinformatic methods used to analyze sequencing data may have a greater influence on estimates of community composition than library preparation method used, likely due in part to the extent and curation of the reference databases considered. Thus, enriching existing aliquots of shotgun metagenomic libraries and obtaining modest numbers of reads from them offers an efficient orthogonal method for assessment of bacterial community composition.

59 BASIC BIOLOGICAL SCIENCES↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A streamlined tandem tip-based workflow for sensitive nanoscale phosphoproteomics

Effective phosphoproteome of nanoscale sample analysis remains a daunting task, primarily due to significant sample loss associated with non-specific surface adsorption during enrichment of low stoichiometric phosphopeptide. We develop a tandem tip phosphoproteomics sample preparation method that is capable of sample cleanup and enrichment without additional sample transfer, and its integration with our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches provides a streamlined workflow enabling sensitive, high-throughput nanoscale phosphoproteome measurements. This approach significantly reduces both sample loss and processing time, allowing the identification of >3000 (>9500) phosphopeptides from 1 (10) µg of cell lysate using the label-free method without a spectral library. It also enables precise quantification of ~600 phosphopeptides from 100 sorted cells (single-cell level input for the enriched phosphopeptides) and ~700 phosphopeptides from human spleen tissue voxels with a spatial resolution of 200 µm (equivalent to ~100 cells) in a high-throughput manner. The new workflow opens avenues for phosphoproteome profiling of mass-limited samples at the low nanogram level.

59 BASIC BIOLOGICAL SCIENCES↗

An organogel library for solution NMR analysis of nanoparticle suspensions in non-aqueous samples

Surface contrast solution NMR methods (scNMR) are emerging as powerful tools to investigate the adsorption of small molecule ligands to the surface of nanoparticles (NP), returning fundamental insight into the kinetics and thermodynamics of sorption, as well as structural information on the adsorbed species. A prerequisite for the acquisition of high quality solution NMR data is the preparation of homogeneous and stable samples that return consistent NMR spectra and allow extensive signal averaging. Unfortunately, this condition does not apply to NMR samples containing NPs that often show a tendency to sediment and accumulate at the bottom of the NMR tube over the course of the experiment. We have recently shown that preparing NMR samples in an agarose gel matrix inhibits sedimentation and allows the characterization of small molecule-NP interactions by scNMR. Unfortunately, as the agarose gel only forms in aqueous solution, this sample preparation method cannot be used to stabilize NP suspensions in a non-aqueous environment. In this work, we introduce a library of 48 organogels, based on low molecular-mass organic gelators (LMOGs), to prepare NMR samples of small molecule/NP systems in a wide range of organic solvents. In addition, we present a simple method that takes advantage of 1H transverse relaxation (1H-R2) measurements to screen the library and identify the best gelator to characterize the small molecule-NP interaction of interest in the solvent of choice. We expect the results of this study will enable the preparation of homogeneous and stable samples of NPs in non-aqueous environments, therefore dramatically increasing the applicability of scNMR to the characterization of heterogeneous interactions and to the investigation of the role played by solvent molecules in regulating the kinetics and thermodynamics of sorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Classical and quantum computing of shear viscosity for ( 2 + 1 ) D SU(2) gauge theory

We perform a nonperturbative calculation of the shear viscosity for ( 2 + 1 )-dimensional SU(2) gauge theory by using the lattice Hamiltonian formulation. The retarded Green’s function of the stress-energy tensor is calculated from real time evolution via exact diagonalization of the lattice Hamiltonian with a local Hilbert space truncation, and the shear viscosity is obtained via the Kubo formula. When taking the continuum limit, we account for the renormalization group flow of the coupling but no additional operator renormalization. We find the ratio of the shear viscosity and the entropy density η s is consistent with a well-known holographic result 1 4 π at several temperatures on a 4 × 4 honeycomb lattice with the local electric representation truncated at j max = 1 2 . We also find the ratio of the spectral function and frequency ρ x y ( ω ) ω exhibits a peak structure when the frequency is small. Both the exact diagonalization method and simple matrix product state classical simulation method beyond j max = 1 2 on bigger lattices require exponentially growing resources. So we develop a quantum computing method to calculate the retarded Green’s function and analyze various systematics of the calculation including j max truncation and finite size effects, Trotter errors and the thermal state preparation efficiency. Our thermal state preparation method still requires resources that grow exponentially with the lattice size, but with a very small prefactor at high temperature. We test our quantum circuit on both the Quantinuum emulator and the IBM simulator for a small lattice and obtain results consistent with the classical computing ones. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microstructural investigation of PBX 9501: Comparing wet slurry and resonant acoustic mixing techniques

The microstructure of a high explosive (HE) material directly influences the reactive behavior under a variety of insults. Furthermore, the preparation method of polymer-bonded explosives (PBX), as well as the constituent material particle size distribution and consolidation parameters, will dominate the microstructural features that are observed. Here, we compare batches of PBX 9501 prepared by the typical wet slurry process and those prepared by resonant acoustic mixing. The “prills” produced by the wet slurry process leads to an inherently different microstructure than the coated powder produced by resonant acoustic mixing. Additionally, we observed that the conditions required to consolidate (press) the material to the nominal PBX 9501 density varied depending on the preparation technique, which also dictates the observed binder distribution. Furthermore, X-ray microcomputed tomography and ultra-small-angle X-ray scattering analyses revealed distinct differences in the void structure and distribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modular automated bottom-up proteomic sample preparation for high-throughput applications

Manual proteomic sample preparation methods limit sample throughput and often lead to poor data quality when thousands of samples must be analyzed. Automated liquid handler systems are increasingly used to overcome these issues for many of the sample preparation steps. Here, we detail a step-by-step protocol to prepare samples for bottom-up proteomic analysis for Gram-negative bacterial and fungal cells. The full modular protocol consists of three optimized protocols to: (A) lyse Gram-negative bacteria and fungal cells; (B) quantify the amount of protein extracted; and (C) normalize the amount of protein and set up tryptic digestion. These protocols have been developed to facilitate rapid, low variance sample preparation of hundreds of samples, be easily implemented on widely-available Beckman-Coulter Biomek automated liquid handlers, and allow flexibility for future protocol development. By using this workflow 50 micrograms of protein from 96 samples can be prepared for tryptic digestion in under an hour. We validate these protocols by analyzing 47 Pseudomonas putida and Rhodosporidium toruloides samples and show that this modular workflow provides robust, reproducible proteomic samples for high-throughput applications. The expected results from these protocols are 94 peptide samples from Gram-negative bacterial and fungal cells prepared for bottom-up quantitative proteomic analysis without the need for desalting column cleanup and with protein relative quantity variance (CV%) below 15%.

59 BASIC BIOLOGICAL SCIENCES↗

Performing In Situ Closed-Cell Gas Reactions in the Transmission Electron Microscope

Gas reactions studied by in situ electron microscopy can be used to capture the real-time morphological and microchemical transformations of materials at length scales down to the atomic level. In situ closed-cell gas reaction (CCGR) studies performed using (scanning) transmission electron microscopy (STEM) can separate and identify localized dynamic reactions, which are extremely challenging to capture using other characterization techniques. For these experiments, we used a CCGR holder that utilizes microelectromechanical systems (MEMS)-based heating microchips (hereafter referred to as "E-chips"). The experimental protocol described here details the method for performing in situ gas reactions in dry and wet gases in an aberration-corrected STEM. This method finds relevance in many different materials systems, such as catalysis and high-temperature oxidation of structural materials at atmospheric pressure and in the presence of various gases with or without water vapor. Here, several sample preparation methods are described for various material form factors. During the reaction, mass spectra obtained with a residual gas analyzer (RGA) system with and without water vapor further validates gas exposure conditions during reactions. Integrating an RGA with an in situ CCGR-STEM system can, therefore, provide critical insight to correlate gas composition with the dynamic surface evolution of materials during reactions. In situ/operando studies using this approach allow for detailed investigation of the fundamental reaction mechanisms and kinetics that occur at specific environmental conditions (time, temperature, gas, pressure), in real-time, and at high spatial resolution.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗