Search NASA⌕ Search

SEARCH · Search NASA

Results for “pressure calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Use of the Ames Check Standard Model for the Validation of Wall Interference Corrections

The new check standard model of the NASA Ames 11-ft Transonic Wind Tunnel was chosen for a future validation of the facility's wall interference correction system. The chosen validation approach takes advantage of the fact that test conditions experienced by a large model in the slotted part of the tunnel's test section will change significantly if a subset of the slots is temporarily sealed. Therefore, the model's aerodynamic coefficients have to be recorded, corrected, and compared for two different test section configurations in order to perform the validation. Test section configurations with highly accurate Mach number and dynamic pressure calibrations were selected for the validation. First, the model is tested with all test section slots in open configuration while keeping the model's center of rotation on the tunnel centerline. In the next step, slots on the test section floor are sealed and the model is moved to a new center of rotation that is 33 inches below the tunnel centerline. Then, the original angle of attack sweeps are repeated. Afterwards, wall interference corrections are applied to both test data sets and response surface models of the resulting aerodynamic coefficients in interference-free flow are generated. Finally, the response surface models are used to predict the aerodynamic coefficients for a family of angles of attack while keeping dynamic pressure, Mach number, and Reynolds number constant. The validation is considered successful if the corrected aerodynamic coefficients obtained from the related response surface model pair show good agreement. Residual differences between the corrected coefficient sets will be analyzed as well because they are an indicator of the overall accuracy of the facility's wall interference correction process.

wind tunnel wall interferenc↗

Pressure Transducer Remote Calibration/Health Check

This presentation reports on efforts to develop an in-situ pressure transducer calibration system for extension of calibration lifecycle and transducer health determination. This system aims to: (1) provide a long term solution to determining the calibration of pressure transducers for gas applications, (2) provide a method of isolating problems in remote measurements, and (3) reduce costs and resources by extending the length of time a transducer may be left in a system without a repeat laboratory calibration. Topic covers include: design requirements, design assumptions and design approach.

Deyoe, Richard↗

Dissociation energies of some high temperature molecules containing aluminum

The Knudsen cell mass spectrometric method has been used to investigate the gaseous molecules Al2, AlSi,AlSiO, AlC2, Al2C2, and AlAuC2. Special attention was given to the experimental considerations and techniques needed to identify and to measure ion intensities for very low abundance molecular species. Second- and third-law procedures were used to obtain reaction enthalpies for pressure calibration independent and isomolecular exchange reactions. Dissociation energies for the molecules were derived from the measured ion intensities, free-energy functions obtained from estimated molecular constants, and auxiliary thermodynamic data. The bonding and stability of these aluminum containing molecules are compared with other similar species.

Stearns, C. A.↗

Performance tests on the Kohmyr ECC ozone sonde

The reliability and accuracy of the Kohmyr ECC ozone sonde are determined. Emphasis is placed on establishing and testing for leak-free connections and stable pump flow rates as well as properly adjusting the pumping pressure. Calibration of the Kohmyr ECC ozone sondes and Dasibi monitors is described. Raw ordinate data and ozone connection data are presented in tabular form. The results of a linear regression treatment of the sonde-indicated ozone concentration vs. Dasibi readings for each switch position are included along with averages of the regression parameters over the six sequencing switch positions. It is suggested that sondes and Dasibi monitors be individually calibrated before flight.

Bandy, A. R.↗

Wind tunnel and ground static tests of a .094 scale powered model of a modified T-39 lift/cruise fan V/STOL research airplane

Ground static and wind tunnel test of a scale model modified T-39 airplane are reported. The configuration in the nose and replacement of the existing nacelles with tilting lift/cruise fans. The model was powered with three 14 cm diameter tip driven turbopowered simulators. Forces and moments were measured by an internal strain guage balance. Engine simulator thrust and mass flow were measured by calibrated pressure and temperature instrumentation mounted downstream of the fans. The low speed handling qualities and general aerodynamic characteristics of the modified T-39 were defined. Test variables include thrust level and thrust balance, forward speed, model pitch and sideslip angle at forward speeds, model pitch, roll, and ground height during static tests, lift/cruise fan tilt angle, flap and aileron deflection angle, and horizonal stabilizer angle. The effects of removing the landing gear, the lift/cruise fans, and the tail surfaces were also investigated.

Hunt, D.↗

Pressure measurement system for the National Transonic Facility

The electronically scanned pressure (ESP) measurement system concept was selected for application at the Langley Research Center's National Transonic Facility. This pressure measurement application required a complex system design to meet the pressure resolution, range, and accuracy requirements over this facility's wide operating pressure and temperature range of 1.38 x 10 to the 5th to 9.3 x 10 to the 5th N/sq m and 80 to 340 K, respectively. The design uses five ESP systems to measure the nearly 1000 channels of pressure located throughout the facility circuit. Pressure modules mounted inside the facility were housed in specially designed thermal enclosures, while the modules mounted outside the tunnel were mounted in pressure vessels. The unique features of this pressure measurement system design including a special ESP module pressure calibration unit are presented.

Mitchell, M.↗

X-ray investigations related to the shock history of the Shergotty achondrite

The shock stress suffered by naturally shocked materials from the Shergotty achondrite was studied using X-ray diffraction techniques and experimentally shocked augite and enstatite as standards. The Shergotty pyroxenes revealed the formation of continuous diffraction rings, line broadening, preferred orientation of small scale diffraction domains, and other evidence of substantial lattice disorders. As disclosed by the application of Debye-Scherrer techniques, they are hybrids between single crystals and fine-grained random powders. The pyroxene lattice is very resistant to shock damage on smaller scales. While measurable lattice disaggregation and progressive fragmentation occur below 25 GPa, little additional damage is suffered from application of pressures between 30 to 60 GPa, making pressure calibration of naturally shocked pyroxenes via X-ray methods difficult. Powder diffractometer scans on pure maskelynite fractions of Shergotty revealed small amounts of still coherently diffracting plagioclase, which may contribute to the high refractive indices of the diaplectic feldspar glasses of Shergotty.

Horz, F.↗

SUMS experiment flight results on STS-35

Calibrated pressure measurements for species with mass to charge ratios up to 50 amu/e(-) were obtained from the Shuttle Upper Atmosphere Mass Spectrometer (SUMS) experiment during reentry on the STS-35 mission. Data were collected from 180 km, when the signal rose above the background, to about 87 km, when the SUMS system automatically closed the gas inlet value. However, data above 115 km was contaminated from a source of gas emanating from pressure transducers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data is compared with the mass spectrometer total pressure with excellent agreement. The free-stream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. standard atmosphere model, exhibits the wave-like nature seen on previous flights using accelerometry. In addition, selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump. An analysis of the spectra data from this event is presented to show that no significant permanent changes occurred which affected the data interpretation at lower altitudes. Further, the localized chemistry from the individual species during the onset of aerodynamic heating is examined to the extent possible for a closed source system, such as SUMS. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions with the carbon panels of the Orbiter and absorbed oxygen on the system tubing.

Blanchard, Robert C.↗

The discrepancy between stratospheric ozone profiles from balloon soundings and from other techniques: A possible explanation

Regular balloon ozone soundings with electrochemical sondes have been performed at Uccle since 1969. More than 450 ozone soundings between 1985 and 1989 were used to calculate the altitudes Zs from the VIZ radiosonde data and the altitudes Zr deduced from the tracking of the balloon train with a primary wind-finding radar. The values of Zs at fixed times appeared to be systematically too low as compared to Zr. The differences Zr-Zs increase with altitude; at 30 km the annual mean values of Zr-Zs (plus or minus standard deviation) vary between 590 plus or minus 910 m and 1410 plus or minus 1160 m, according to the pressure calibration of different manufacturing series of radiosondes. From these results it is found that around the 30 km level the ozone concentrations calculated from soundings with VIZ sondes are too low by 7.5 to 14 percent, depending upon the manufacturing series of radiosondes. At least part of the discrepancy which has often been found between ozone profiles from balloon soundings and from other techniques such as rocket observations or Umkehr measurements may be explained by this effect. An altitude correction would have important consequences as to the climatology of ozone in the middle stratosphere as adopted at the moment. About half of the day-to-day variability of ozone observed from soundings with VIZ radiosondes above the 30 km level, is induced by the variability of Zr-Zs. The agreement between altitudes calculated from radar data and Vaisala radiosondes is much better; from 34 comparative soundings a mean difference (plus or minus standard deviation) of about -300 plus/minus 180 m was found at 30 km.

Demuer, Dirk↗

Simultaneous Luminescence Pressure and Temperature Mapping System

A simultaneous luminescence pressure and temperature mapping system is developed including improved dye application techniques for surface temperature and pressure measurements from 5 torr to 1000 torr with possible upgrade to from 0.5 torr to several atmospheres with improved camera resolution. Adsorbed perylene dye on slip-cast silica is pressure (oxygen) sensitive and reusable to relatively high temperatures (approximately 150 C). Adsorbed luminescence has an approximately linear color shift with temperature, which can be used for independent temperature mapping and brightness pressure calibration with temperature.

Buck, Gregory M.↗

Shuttle Upper Atmosphere Mass Spectrometer Experimental Flight Results

Calibrated pressure measurements for species with mass-to-charge ratios up to 50 amu/e(-) were obtained trom the shuttle upper atmosphere mass spectrometer experiment during re-entry on the STS-35 mission. The principal experimental objective is to obtain measurements of freestream density in the hypersonic rarefied flow flight regime. Data were collected from 180 to about 87 km. However, data above 115 km were contaminated from a source of gas emanating from pressure transdueers connected in parallel to the mass spectrometer. At lower altitudes, the pressure transducer data are compared to the mass spectrometer total pressure with excellent agreement. Near the orifice entrance, a significant amount of CO2 was generated from chemical reactions. The freestream density in the rarefied flow flight regime is calculated using an orifice pressure coefficient model based upon direct simulation Monte Carlo results. This density, when compared with the 1976 U.S. Standard Atmosphere model, exhibits the wavelike nature seen on previous flights using accelerometry. Selected spectra are presented at higher altitudes (320 km) showing the effects of the ingestion of gases from a forward fuselage fuel dump.

Blanchard, R. C.↗

Simultaneous Luminescence Pressure and Temperature Mapping

A simultaneous luminescence pressure and temperature mapping system is developed including improved dye application techniques for surface temperature and pressure measurements from 5 torr to 1000 torr with possible upgrade to from 0.5 torr to several atmospheres with improved camera resolution. Adsorbed perylene dye on slip-cast silica is pressure (oxygen) sensitive and reusable to relatively high temperatures (-150 C). Adsorbed luminescence has an approximately linear color shift with temperature, which can be used for independent temperature mapping and brightness pressure calibration with temperature.

Buck, Gregory M.↗

Detection Angle Calibration of Pressure-Sensitive Paints

Uses of the pressure-sensitive paint (PSP) techniques in areas other than external aerodynamics continue to expand. The NASA Glenn Research Center has become a leader in the application of the global technique to non-conventional aeropropulsion applications including turbomachinery testing. The use of the global PSP technique in turbomachinery applications often requires detection of the luminescent paint in confined areas. With the limited viewing usually available, highly oblique illumination and detection angles are common in the confined areas in these applications. This paper will describe the results of pressure, viewing and excitation angle dependence calibrations using three popular PSP formulations to get a better understanding of the errors associated with these non-traditional views.

Bencic, Timothy J.↗

Thermodynamic Activity Measurements with Knudsen Cell Mass Spectrometry

Coupling the Knudsen effusion method with mass spectrometry has proven to be one of the most useful experimental techniques for studying the equilibrium between condensed phases and complex vapors. The Knudsen effusion method involves placing a condensed sample in a Knudsen cell, a small "enclosure", that is uniformly heated and held until equilibrium is attained between the condensed and vapor phases. The vapor is continuously sampled by effusion through a small orifice in the cell. A molecular beam is formed from the effusing vapor and directed into a mass spectrometer for identification and pressure measurement of the species in the vapor phase. Knudsen cell mass spectrometry (KCMS) has been used for nearly fifty years now and continues to be a leading technique for obtaining thermodynamic data. Indeed, much of the well-established vapor specie data in the JANAF tables has been obtained from this technique. This is due to the extreme versatility of the technique. All classes of materials can be studied and all constituents of the vapor phase can be measured over a wide range of pressures (approximately 10(exp -4) to 10(exp -11) bar) and temperatures (500-2800 K). The ability to selectively measure different vapor species makes KCMS a very powerful tool for the measurement of component activities in metallic and ceramic solutions. Today several groups are applying KCMS to measure thermodynamic functions in multicomponent metallic and ceramic systems. Thermodynamic functions, especially component activities, are extremely important in the development of CALPHAD (Calculation of Phase Diagrams) type thermodynamic descriptions. These descriptions, in turn, are useful for modeling materials processing and predicting reactions such as oxide formation and fiber/matrix interactions. The leading experimental methods for measuring activities are the Galvanic cell or electro-motive force (EMF) technique and the KCMS technique. Each has specific advantages, depending on material and conditions. The EMF technique is suitable for lower temperature measurements, provided a suitable cell can be constructed. KCMS is useful for higher temperature measurements in a system with volatile components. In this paper, we briefly review the KCMS technique and identify the major experimental issues that must be addressed for precise measurements. These issues include temperature measurements, cell material and cell design and absolute pressure calibration. The resolution of these issues are discussed together with some recent examples of measured thermodynamic data.

Copland, Evan H.↗

Development of dynamic calibration methods for POGO pressure transducers

Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.

Hilten, J. S.↗