At least 91 records · Page 5

High Pressure Gas Permeation and Liquid Diffusion Studies of Coflon and Tefzel Thermoplastics

The life of fluid-carrying flexible or umbilical pipes during service at elevated temperatures and pressures depends inter alia on their resistance to attack by the fluids present and the rate at which these fluids are absorbed by the pipe lining materials. The consequences of fluid ingress into the thermoplastic lining could mean a) a reduction in its mechanical strength, to increase chances of crack formation and growth and thus a loss of integrity, b) the occurrence of permeation right through the lining material, with pressure build- up in the outer pipe wall construction (of flexible pipes) or chemical attack (from a hostile permeant) on outer layers of reinforcements. Therefore it is important within this project to have relevant permeation data for Coflon and Tefzel thermoplastics: the former is plasticised, the latter is not. A previous report (CAPP/M.2) described experimental equipment and techniques used by MERL when measuring high pressure (up to 5000 psi) gas permeation and liquid diffusion through thermoplastic samples cut from extruded bar or pipe, and provided the basic theory involved. Norsk Hydro are also performing gas permeation tests on pipe sections, at up to 100 bars (1450 psi) pressure or so, and reporting separately. Some comparisons between data from Norsk Hydro and MERL have been made herein. The tests should be considered as complementary, as the Norsk Hydro test has the obvious benefit of using complete pipe sections, whilst MERL can test at much higher pressures, up to 1000 bar if necessary. The sophisticated analytical measuring equipment of Norsk Hydro can distinguish the individual components of mixed gases and hence the various permeation-linked coefficients whereas MERL, in using pressure increase at constant volume to determine permeation rate, is limited to obtaining single gas data, or apparent (or representative) coefficients for a mixed gas as a whole. Except for the initial fluid diffusion data for Tefzel described in CAPP/M.2, the present report covers all aspects of fluid permeation and diffusion for Coflon and Tefzel, including all the pen-neation data accumulated in the project to date. Test gases have mainly been methane (CH4) and carbon dioxide (CO2). More high pressure (HP) gas permeation tests have been performed since the last issue of this report, most being concerned with changes in permeation characteristics brought about by ageing in various relevant fluids. This revision supersedes previous issues.

Morgan, G. J.↗

Influence of the structure of inlet free-stream turbulence on diffuser performance

The pressure recovery coefficient of a two-dimensional diffuser (Cp) was found to be significantly affected by the intensity and structure of the inlet free-stream turbulence. Significantly larger values of Cp occurred for the case of highly anisotropic inlet free-stream turbulence with the plane of rotation of the eddies parallel to the free-stream flow and perpendicular to the diverging walls of the diffuser, as compared to the values of Cp for the case of grid-generated near-isotropic inlet conditions. The relatively high values of Cp for the case of the highly anisotropic inlet free-stream turbulence conditions can be attributed to highly effective mixing, where the plane of rotation of the eddies facilitates a direct transport of momentum from the free-stream to the boundary layers along the diverging walls of the diffuser, as compared to the mixing that occurs with grid-generated highly unorganized eddies.

Hoffmann, Jon A.↗

Active control of vaneless diffuser rotating stall

Experiments were carried out to study the feasibility of active stabilization of vaneless diffuser rotating stalls. Pressure fluctuation at the diffuser inlet was monitored and used to control the rotating stall. AC control flow, which is produced by a load speaker, was introduced into the diffuser at the inlet. It is shown that the rotating stall can be suppressed when the phase of the control flow has a certain relation with the phase of the rotating stall. By considering the energy flux due to the AC control flow, it is shown that the rotating stall is suppressed when the control flow has the phase such that the energy is subtracted out from the diffuser flow. Discussions are made on the relations between the energy flux and the amplitude of the pressure fluctuation due to the rotating stalls.

Yoshida, Yoshiki↗

Transport Phenomena of Off-Axis Sputtering Deposition

Various high quality epitaxial films, especially oxides, have been synthesized using off-axis sputtering deposition. In this presentation, we report the experiment results of ZnO films grown by the off-axis sputtering deposition. Films were synthesized in temperatures ranged from room temperature to 600 C, and pressures from 5 mTorr to 150 mTorr. Film growth rate was measured by surface profilometer, ellipsometer, and wavelength dispersive spectrometry. Due to the collisions between the sputtered species and the residue gases, the kinetic energy of species was reduced and the transport of depositing species changed from a ballistic movement for low pressure to a diffusive drift for high pressure in which the transport species were almost thermalized. The measurements show an increase of growth rates along the gravity vector when the Knudsen number of transport species is less than 0.05, which suggests that gravity affected the transport characterization in off-axis sputtering deposition. Because the product of pressure (p) and travel distance (d) of sputtered species, pd, exceeds several mTorr-cm during film deposition, the classical simulations for sputtering process in high vacuum system may not be applied. Based on these experimental measurements, a transport process of the off-axis sputtering deposition is proposed. Several models including the Monte Carlo method and gravity-driven flow dynamics simulation will be discussed.

Zhu, S.↗

Transport Phenomena of Off-Axis Sputtering Deposition

Various high quality epitaxial films, especially oxides, have been synthesized using off-axis sputtering deposition. In this presentation, we report the experiment results of ZnO films grown by the off-axis sputtering deposition. Films were synthesized in temperatures ranged from room temperature to 600 C, and pressures from 5 mTorr to 150 mTorr. Film growth rate was measured by surface profilometer, ellipsometer, and wavelength dispersive spectrometry. Due to the collisions between the sputtered species and the residue gases, the kinetic energy of species was reduced and the transport of depositing species changed from a ballistic movement for low pressure to a diffuse drift for high pressure in which the transport species were almost thermalized. The measurements show an increase of growth rates along the gravity vector when the Knodson (Knudsen??) number of transport species is less than 0.05, which suggests that gravity affected the transport characterization in off-axis sputtering deposition. Because the product of pressure (p) and travel distance (d) of sputtered species, p exceeds several mTorr-cm during film deposition, the classical simulations for sputtering process in high vacuum system may not be applied. Based on these experimental measurements, a transport process of the off-axis sputtering deposition is proposed. Several methods including the Monte Carlo method and gravity-driven flow dynamics simulation will be discussed.

Zhu, S.↗

Effect of Ram-jet Pressure Pulsations on Supersonic-diffuser Performance

Experimental study of effects of combustion roughness and controlled mechanical oscillations on diffuser operation was conducted on an 8-inch ram jet at Mach number 1.87. Within experimental accuracy, the optimum mean combustion-chamber static pressure occurred when the maximum instantaneous static pressure equalled the optimum steady-flow value and the corresponding decrement in optimum mean static pressure was equal to one-half the total amplitude of the pressure pulsations. A marked attenuation of amplitude of cold-buzz pressure fluctuations was effected over limited range of subcritical diffuser operation by means of properly tuned rotating disk located in combustion chamber.

Connors, James F↗

Characterization of the Reverberation Chamber at the NASA Langley Structural Acoustics Loads and Transmission (SALT) Facility

In 2011 the noise generating capabilities in the reverberation chamber of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center were enhanced with two fiberglass reinforced polyester resin exponential horns, each coupled to Wyle Acoustic Source WAS-3000 airstream modulators. This report describes the characterization of the reverberation chamber in terms of the background noise, diffusivity, sound pressure levels, the reverberation times and the related overall acoustic absorption in the empty chamber and with the acoustic horn(s) installed. The frequency range of interest includes the 80 Hz to 8000 Hz one-third octave bands. Reverberation time and sound pressure level measurements were conducted and standard deviations from the mean were computed. It was concluded that a diffuse field could be produced above the Schroeder frequency in the 400 Hz one-third octave band and higher for all applications. This frequency could be lowered by installing panel diffusers or moving vanes to improve the acoustic modal overlap in the chamber. In the 80 Hz to 400 Hz one-third octave bands a successful measurement will be dependent on the type of measurement, the test configuration, the source and microphone locations and the desired accuracy. It is recommended that qualification measurements endorsed in the International Standards be conducted for each particular application.

Grosveld, Ferdinand W.↗

Thermal property measurements on lunar material returned by Apollo 11 and 12 missions.

Measurement of thermal diffusivity on Apollo 11 type A and type C samples in the temperature range between 150 and 440 K under atmospheric pressure. Thermal diffusivity of type C material is lower and less temperature-dependent than type A material. Both types of samples exhibit lower thermal diffusivities than nonporous terrestrial basalt. The rate of heat generation of Apollo 11 and 12 samples was calculated from the concentrations of radioactive elements: potassium, thorium, and uranium. Apollo 11 crystalline rocks show an average rate of heat generation which is not significantly different from terrestrial basalt. The Th/U ratio does not differ greatly from chondritic and terrestrial averages.

Horai, K.-I.↗

Force and Pressure Recovery Characteristics at Supersonic Speeds of a Conical Spike Inlet with a Bypass Discharging from the Top or Bottom of the Diffuser in an Axial Direction

Force and pressure-recovery characteristics of a nacelle-type conical-spike inlet with a fixed-area bypass located in the top or bottom of the diffuser are presented for flight Mach numbers of 1.6, 1.8, and 2.0 for angles of attack from 0 degrees to 9 degrees. Top or bottom location of the bypass did not have significant effects on diffuser pressure-recovery, bypass mass-flow ratio, or drag coefficient over the range of angles of attack, flight Mach numbers, and stable engine mass-flow ratios investigated. A larger stable subcritical operating range was obtained with the bypass on the bottom at angles of attack from 3 degrees to 9 degrees at a flight Mach number of 2.0. At a flight Mach number of 2.0, the discharge of 14 percent of the critical mass flow of the inlet by means of a bypass increased the drag only one-fifth of the additive drag that would result for equivalent spillage behind an inlet normal shock without significant reductions in diffuser pressure recovery.

DIFFUSERS, SUBSONIC↗

Effect of Static Strains on Diffusion

A theory is developed that gives the diffusion coefficient in strained systems as an exponential function of the strain. This theory starts with the statistical theory of the atomic jump frequency as developed by Vineyard. The parameter determining the effect of strain on diffusion is related to the changes in the inter-atomic forces with strain. Comparison of the theory with published experimental results for the effect of pressure on diffusion shows that the experiments agree with the form of the theoretical equation in all cases within experimental error.

Girifalco, L. A.↗

Experimental performance of a 13.65-centimeter-tip-diameter tandem-bladed sweptback centrifugal compressor designed for a pressure ratio of 6

A 13.65 cm tip diameter backswept centrifugal impeller having a tandem inducer and a design mass flow rate of 0.907 kg/sec was experimentally investigated to establish stage and impeller characteristics. Tests were conducted with both a cascade diffuser and a vaneless diffuser. A pressure ratio of 5.9 was obtained near surge for the smallest clearance tested. Flow range at design speed was 6.3 percent for the smallest clearance test. Impeller exit to shroud axial clearance at design speed was varied to determine the effect on stage and impeller performance.

Klassen, H. A.↗

Analytical and experimental study of axisymmetric truncated plug nozzle flow fields

Experimental and analytical investigation of the flow field and base pressure of internal-external-expansion truncated plug nozzles are discussed. Experimental results for two axisymmetric, conical plug-cylindrical shroud, truncated plug nozzles are presented for both open and closed wake operations. These results include extensive optical and pressure data covering nozzle flow field and base pressure characteristics, diffuser effects, lip shock strength, Mach disc behaviour, and the recompression and reverse flow regions. Transonic experiments for a special planar transonic section are presented. An extension of the analytical method of Hall and Mueller to include the internal shock wave from the shroud exit is presented for closed wake operation. Results of this analysis include effects on the flow field and base pressure of ambient pressure ratio, nozzle geometry, and the ratio of specific heats. Static thrust is presented as a function of ambient pressure ratio and nozzle geometry. A new transonic solution method is also presented.

Muller, T. J.↗

Numerical Study of the Transient Vaporization of an Oxygen Droplet at Sub- and Super-Critical Conditions

Unsteady vaporization of a droplet in a high-pressure quiescent environment has been studied. With spherical symmetry and constant pressure, the process is diffusion controlled. At low pressures droplet heating is significant for most of the droplet lifetime, and an unsteady analysis of the gas phase is required. Then, the vaporization of a liquid oxygen droplet in gaseous hydrogen at moderate and high pressures is considered. At super-critical pressures, the surface temperature reaches the computed critical mixture value where a model for super-critical combustion is needed. The details of the diffusion layer of dissolved hydrogen do not significantly affect the results. Various methods are explored to compute the gas-phase density. Under the model's assumptions, homogeneous nucleation is not likely to occur.

Delplanque, J.-P.↗

Terminal-shock and restart control of a Mach 2.5, axisymmetric, mixed compression inlet with 40 percent internal contraction

Results of experimental tests conducted on a supersonic, mixed-compression, axisymmetric inlet are presented. The inlet is designed for operation at Mach 2.5 with a turbofan engine (TF-30). The inlet was coupled to either a choked orifice plate or a long duct which had a variable-area choked exit plug. Closed-loop frequency responses of selected diffuser static pressures used in the terminal-shock control system are presented. Results are shown for Mach 2.5 conditions with the inlet coupled to either the choked orifice plate or the long duct. Inlet unstart-restart traces are also presented. High-response inlet bypass doors were used to generate an internal disturbance and also to achieve terminal-shock control.

Baumbick, R. J.↗

Experimental investigation of wall shock cancellation and reduction of wall interference in transonic testing

A series of experiments were performed to evaluate the effectiveness of a three-dimensional land and groove wall geometry and a variable permeability distribution to reduce the interference produced by the porous walls of a supercritical transonic test section. The three-dimensional wall geometry was found to diffuse the pressure perturbations caused by small local mismatches in wall porosity permitting the use of a relatively coarse wall porosity control to reduce or eliminate wall interference effects. The wall porosity distribution required was found to be a sensitive function of Mach number requiring that the Mach number repeatability characteristics of the test apparatus be quite good. The effectiveness of a variable porosity wall is greatest in the upstream region of the test section where the pressure differences across the wall are largest. An effective variable porosity wall in the down stream region of the test section requires the use of a slightly convergent test section geometry.

Ferri, A.↗