Search NASA⌕ Search

SEARCH · Search NASA

Results for “pulse analysis measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Miniature High-Let Radiation Spectrometer for Space and Avionics Applications

This paper reports on the design and characterization of a small, low power, and low weight instrument, a High-LET Radiation Spectrometer (HiLRS), that measures energy deposited by heavy ions in microelectronic devices. The HILRS operates on pulse-height analysis principles and is designed for space and avionics applications. The detector component in the instrument is based on large scale arrays of p-n junctions. In this system, the pulse amplitude from a particle hit is directly proportional to the particle LET. A prototype flight unit has been fabricated and calibrated using several heavy ions with varying LETs and protons with several energies. The unit has been delivered to the Ballistic Missile Defense Organization (BMDO) c/o the Air Force Research Laboratory in Albuquerque, NM, for integration into the military Space Technology Research Vehicle (STRV), a US-UK cooperative mission. Another version of HILRS is being prepared for delivery in April to the Hubble Space Telescope (HST) project, to fly on the HST Orbital Systems Test (HOST) Platform on a shuttle mission.

Stassinopoulos, E. G.↗

Laser space rendezvous and docking system study continuation

Investigations were made of a configuration for a spaceborne laser radar (ladar) to meet the requirements for rendezvous and docking with a cooperative object in synchronous orbit. An analysis was completed of laser phase locking techniques, while experimental verification was made of pulse repetition frequency and resonant scanning control loops. Data measurements on a satellite mock-up were also made. The investigation supports the original contention that a rendezvous and docking ladar can be configured to offer a cost effective and reliable solution to envisioned space missions.

Adelman, S.↗

On the 2018 Outburst of the Accreting Millisecond X-Ray Pulsar Swift J1756.9-2508 As Seen with NICER

We report on the coherent timing analysis of the 182 Hz accreting millisecond X-ray pulsar SwiftJ1756.92508during its 2018 outburst as observed with the Neutron Star Interior Composition Explorer (NICER). Combiningour NICER observations with Rossi X-ray Timing Explorer observations of the 2007 and 2009 outbursts, we alsostudied the long-term spin and orbital evolution of this source. We find that the binary system is well describedby a constant orbital period model, with an upper limit on the orbital period derivative of Pb < 7.4 ´ 10-13 ss1.Additionally, we improve upon the source coordinates through astrometric analysis of the pulse arrival times,finding R.A.=17h56m57 18±0 08 and decl.=25°0627 8±3 5, while simultaneously measuring thelong-term spin frequency derivative as n = -7.3 ´ 10-16 Hzs1. We briefly discuss the implications of thesemeasurements in the context of the wider population of accreting millisecond pulsars. We reported on the coherent timing analysis of the 2018 outburst of Swift J1756 as observed with NICER. Consistent with analyses of the previous outbursts (Krimm et al. 2007b; Patruno et al. 2010), we find that the X-ray pulsations have energy dependent amplitudes; the fractional amplitude of the fundamental increases with energy, whereas the fractional amplitude of the harmonic shows a slight decline with energy. This energy dependent behavior is not unusual in AMXPs (Patruno & Watts 2012) and can be interpreted in terms of the thermal emission from the stellar hotspot and reprocessing in the accretion column (e.g., Gierliński et al. 2002; Ibragimov & Poutanen 2009). The pulse arrival times of the 2018 outburst are well described by a timing model consisting of a circular orbit with a constant spin frequency. The pulse phases with respect to this model do not show spurious residuals with time or orbital phase, and no evidence is found that the pulse arrival times exhibit an additional delay associated with passing through the gravitational well of the companion star (Shapiro delay). We note, however, that the expected Shapiro delay is given as (Shapiro et al. 1971) Equation (5) where Φ is the orbital phase, G is the gravitational constant, c is the speed of light, and i is the inclination. Even for the maximum allowed companion mass, ${M}_{C}=0.030\,{M}_{\odot }$ (Krimm et al. 2007b, but see Section 4.2 for more details) and an inclination of 90°, the largest delay we can expect is only 4 μs. As this time-delay is smaller than the uncertainty on our phase residuals by nearly two orders of magnitude (see Figure 1), we are not sensitive to Shapiro delays in Swift J1756. Comparing our measurements for the 2018 outburst with those of the 2007 and 2009 outbursts as observed with RXTE, we analyzed the long-term evolution of this source. We found that the binary system is consistent with having a constant orbital period and that the pulsar shows a spin frequency derivative of $\dot{\nu }=-7.3\times {10}^{-16}\,\mathrm{Hz}\,{{\rm{s}}}^{-1}$. 4.1. Spin-down Evolution The long-term spin frequency derivative measured in Swift J1756 is of the same order as the spin frequency derivatives measured in other AMXPs (Hartman et al. 2008; Patruno 2010; Riggio et al. 2011). This frequency change is most likely driven by the neutron star's loss of rotational energy. If so, then the spin-down luminosity is given as Equation (6) where I represents the neutron star moment of inertia. The long-term spin-down of a neutron star is usually assumed to be dominated by the braking torque associated with a spinning magnetic field. Assuming this mechanism is responsible for the observed spin-down in Swift J1756, we can compute the magnetic dipole moment as (Spitkovsky 2006) Equation (7) where α is the misalignment angle between the rotational and magnetic poles. Considering α = 0°–90°, we then find a magnetic field strength of $B\simeq (4\mbox{--}6)\times {10}^{8}$ G at the stellar magnetic poles. This magnetic field strength estimate is in line with those obtained for other accreting millisecond pulsars (see Mukherjee et al. 2015 and references therein). 4.2. Orbit Evolution The observed long-term binary evolution of Swift J1756 is consistent with this source having a constant orbital period and a lower limit on the evolutionary timescale of Equation (8) Binary evolution theory predicts that systems of this type evolve due to angular momentum loss through gravitational radiation (Kraft et al. 1962; Rappaport et al. 1982; Verbunt 1993). For conservative mass transfer, the binary period derivative is given by di Salvo et al. (2008), Equation (9) where MNS is the neutron star mass, $q={M}_{C}/{M}_{\mathrm{NS}}$ is the binary mass ratio, and −1/3 < n < 1 is the mass–radius index of the companion star. Depending on the source inclination, Krimm et al. (2007b) derived a companion mass of ${M}_{C}\,=0.007\mbox{--}0.022\,{M}_{\odot }$ for a neutron star mass of 1.4 ${M}_{\odot }$. For a neutron star mass of 2.2 ${M}_{\odot }$, the allowed range increased to ${M}_{C}=0.009\mbox{--}0.030\,{M}_{\odot }$. In both cases, they assumed an upper limit on the inclination of i < 85°, motivated by the fact that Swift J1756 does not show eclipses in its light curve. Accounting for the extreme cases of stellar masses and n, the binary may either be contracting or expanding. In either case, however, the rate of change is limited to $| {\dot{P}}_{b}| \lesssim 7\times {10}^{-14}$ s s−1, which is well below the upper limit obtained in this work. Although the binary evolution timescale we obtain for Swift J1756 is consistent with theory, it is worth noting that this is not generally true for low-mass X-ray binaries (see Patruno et al. 2017, for a comprehensive discussion). The AMXP SAX J1808.4–3658, in particular, has been found to evolve on a much shorter timescale, with a first derivative on the orbital period of $3.5\times {10}^{-12}$ s s−1 (Hartman et al. 2008; Patruno et al. 2012; Sanna et al. 2017a). Two models have been proposed to explain this discrepancy: highly nonconservative mass transfer due to irradiation of the companion star by the pulsar (di Salvo et al. 2008; Burderi et al. 2009), and spin–orbit coupling in the companion star (Hartman et al. 2008, 2009). While the latter depends on the companion star, and may vary from source to source, the former should operate in all AMXPs (see also Patruno 2017; Sanna et al. 2017c), including Swift J1756. The spin-down luminosity impinging on the companion star can be estimated as Equation (10) where ${\dot{E}}_{\mathrm{abl}}$ is the ablation luminosity, RL2 is the Roche lobe radius of the companion (Eggleton 1983), and a the binary separation. The irradiation fraction is $f={\dot{E}}_{\mathrm{abl}}/{\dot{E}}_{\mathrm{sd}}$, which, accounting for the range of allowed neutron star and companion masses, evaluates to f = 0.15%–0.35%. The associated mass loss for the companion is given by Equation (11) such that, assuming an efficiency of η = 100%, ${\dot{M}}_{C}\,\sim -3\times {10}^{-10}\,{M}_{\odot }$ yr−1. The effect of this mass loss on the orbital period follows through the relation (Frank et al. 2002) Equation (12) giving a period derivative due to mass loss of ${\dot{P}}_{b,\mathrm{ML}}\,=5\times {10}^{-12}$ s s−1. This value is well above our limit on the period derivative. Hence, in order for this mechanism to be consistent with our observations of Swift J1756, the efficiency at which the companion star converts the incident luminosity into mass loss must be η < 15%. This value is very different from the 40% required in SAX J1808.4–3658 (Patruno et al. 2016) and is instead in line with the <5% efficiency determined for IGR J00291+5934 (Patruno 2017). This work was supported by NASA through the NICER mission and the Astrophysics Explorers Program, and made use of data and software provided by the High Energy Astrophysics Science Archive Research Center (HEASARC). P.B. was supported by an NPP fellowship at NASA Goddard Space Flight Center. D.A. acknowledges support from the Royal Society.

Bult, Peter↗

The Voyager Cosmic Ray Experiment

The Voyager Cosmic Ray Experiment includes seven dE/dx-E telescopes to measure the energy and charge of particles with atomic numbers from 1 to 26 in the energy range 1-500 MeV/nucleon and to measure electron energy in the range from 3 to 110 MeV. Isotopic composition of hydrogen through sulfur in the range up to 75 Mev/nucleon can also be resolved. The electronic systems include a dual-gain, charge sensitive preamplifier, 4096-channel pulse height analyzers for three parameter analysis of selected events, and an event type readout polling scheme to maximize the use of available telemetry space and to enhance the occurrence of rare events in the data. Details of the detector, electronic and mechanical design are presented.

Stilwell, D. E.↗

Liquid Bismuth Propellant Flow Sensor

Quantifying the propellant mass flow rate in liquid bismuth-fed electric propulsion systems has two challenging facets. First, the flow sensors must be capable of providing a resolvable measurement at propellant mass flow rates on the order of 10 mg/see with and uncertainty of less that 5%. The second challenge has to do with the fact that the materials from which the flow sensors are fabricated must be capable of resisting any of the corrosive effects associated with the high-temperature propellant. The measurement itself is necessary in order to properly assess the performance (thrust efficiency, Isp) of thruster systems in the laboratory environment. The hotspot sensor[I] has been designed to provide the bismuth propellant mass flow rate measurement. In the hotspot sensor, a pulse of thermal energy (derived from a current pulse and associated joule heating) is applied near the inlet of the sensor. The flow is "tagged" with a thermal feature that is convected downstream by the flowing liquid metal. Downstream, a temperature measurement is performed to detect a "ripple" in the local temperature associated with the passing "hotspot" in the propellant. By measuring the time between the upstream generation and downstream detection of the thermal feature, the flow speed can be calculated using a "time of flight" analysis. In addition, the system can be calibrated by measuring the accumulated mass exiting the system as a-function of time and correlating this with the time it takes the hotspot to convect through the sensor. The primary advantage of this technique is that it doesn't depend on an absolute measurement of temperature but, instead, relies on the observation of thermal features. This makes the technique insensitive to other externally generated thermal fluctuations. In this paper, we describe experiments performed using the hotspot flow sensor aimed at quantifying the resolution of the sensor technology. Propellant is expelled onto an electronic scale to provide an independent measure of the propellant mass flow rate as a function of time. In addition, two separate detection schemes are employed. The first uses a thermocouple to directly measure temperature in the fluid. The second involves the ,use of a fiber optic coupled to a photodiode allowing for detection of an increase in light emission from the fluid as the hotspot passes. the detection location.

Polzin, Kurt A.↗

A unique method to study acoustic transmission through ducts using signal synthesis and averaging of acoustic pulses

An acoustic impulse technique using a loudspeaker driver is developed to measure the acoustic properties of a duct/nozzle system. A signal synthesis method is used to generate a desired single pulse with a flat spectrum. The convolution of the desired signal and the inverse Fourier transform of the reciprocal of the driver's response are then fed to the driver. A signal averaging process eliminates the jet mixing noise from the mixture of jet noise and the internal noise, thereby allowing very low intensity signals to be measured accurately, even for high velocity jets. A theoretical analysis is carried out to predict the incident sound field; this is used to help determine the number and locations of the induct measurement points to account for the contributions due to higher order modes present in the incident tube method. The impulse technique is validated by comparing experimentally determined acoustic characteristics of a duct-nozzle system with similar results obtained by the impedance tube method. Absolute agreement in the comparisons was poor, but the overall shapes of the time histories and spectral distributions were much alike.

Salikuddin, M.↗

Single photon detection and timing in the Lunar Laser Ranging Experiment.

The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

Poultney, S. K.↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

Doppler lidar atmospheric wind sensors - A comparative performance evaluation for global measurement applications from earth orbit

A comparison is made of four prominent Doppler lidar systems, ranging in wavelength from the near UV to the middle IR, which are presently being studied for their potential in an earth-orbiting global tropospheric wind field measurement application. The comparison is restricted to relative photon efficiencies, i.e., the required number of transmitted photons per pulse is calculated for each system for midtropospheric velocity estimate uncertainties ranging from + or - 1 to + or - 4 m/s. The results are converted to laser transmitter pulse energy and power requirements. The analysis indicates that a coherent CO2 Doppler lidar operating at 9.11-micron wavelength is the most efficient.

Menzies, R. T.↗

Aerosol backscatter lidar calibration and data interpretation

A treatment of the various factors involved in lidar data acquisition and analysis is presented. This treatment highlights sources of fundamental, systematic, modeling, and calibration errors that may affect the accurate interpretation and calibration of lidar aerosol backscatter data. The discussion primarily pertains to ground based, pulsed CO2 lidars that probe the troposphere and are calibrated using large, hard calibration targets. However, a large part of the analysis is relevant to other types of lidar systems such as lidars operating at other wavelengths; continuous wave (CW) lidars; lidars operating in other regions of the atmosphere; lidars measuring nonaerosol elastic or inelastic backscatter; airborne or Earth-orbiting lidar platforms; and lidars employing combinations of the above characteristics.

Kavaya, M. J.↗

Wake vortex detection at Denver Stapleton Airport with a pulsed 2-micron coherent lidar

This report describes the effort undertaken to relate aircraft wake history to the local environment. This involved the monitoring of the embedded windfield, monitoring of local meteorological parameters, a high-resolution velocity field analysis in vertical scan planes and measurement of the axial velocity signature. A flashlight pumped 2.09 micron solid state coherent laser radar system was used to detect and track wake vortices. Strong wake vortex signatures were measured for moderate to large aircraft at Denver's Stapleton airport and a large vortex database was compiled.

Hannon, Stephen M.↗

Engineering studies related to geodetic and oceanographic remote sensing using short pulsed techniques

Theoretical basis is presented for a feasibility study of measuring global ocean surface current pattern from satellites and aircraft. The analysis is supported by some preliminary laboratory experiments. Since the ultimate goal is to establish an operational routine for monitoring the global current pattern, a nondisturbing remote sensing device using a laser probe was developed. Detailed construction of the measuring system and the results of some preliminary observations are also presented.

Source record↗

Iridium and tantalum foils for spaceflight neutron dosimetry.

Description of a two-foil system of iridium and tantalum which can measure thermal and intermediate energy neutrons at flux densities of 1 neutron/sq cm-sec over a ten-day lunar mission (1,000,000 neutrons/sq cm). The foils are chemically inert and nontoxic, weigh less than 1 g each, and require only routine gamma pulse height analysis for activation measurement. Detection of fluences below 1,000,000 neutrons/sq cm are achieved for counts of foil activity made as late as two months following neutron exposure. Tantalum foils flown in Apollo 11 indicated a mean dose equivalent to the astronauts of less than 16 mrem from thermal plus intermediate energy neutrons, while nuclear emulsion track analysis indicated approximately 17 mrem from neutrons of energy greater than 0.6 MeV. Iridium foils flown on Apollo 12 indicated dose equivalents of 1.8 to 2.8 mrem from thermal neutrons, excluding tissue thermalized SNAP-27 neutrons.

English, R. A.↗

Nonintrusive Flowmeter

The results of analytical and experimental work performed in the design, fabrication, and test of a prototype nonintrusive gaging system for use in monitoring the consumption of earth-storable fuels and oxidants in either a one-g or a zero-g environment are explained. The design specifications were those applicable to the reaction control system and to the orbital maneuvering system (OMS) fuel and oxidant on the space shuttle while in orbit. The major requirement was for the measurement of flow pulses with sufficient accuracy to provide a continuous knowledge of the fuel and oxidant remaining in the OMS system to within 1% or better. An ultrasonic frequency chirp technique was used having a high inherent rejection for signals traversing stray paths, and for random noise generated by the flowing liquid. A detailed analysis of the frequency chirp approach for two modes of operation (period and phase changes), including an error analysis are reported.

Greene, M. W.↗

TAL Performance and Mission Analysis in a CDL Capacitor Powered Direct-Drive Configuration

The goals of this research are (1) to prove the concept feasibility of a direct-drive electric propulsion system, and (2) to evaluate the performance and characteristics of a Russian TAL (Thruster with Anode Layer) operating in a long-pulse mode, powered by a capacitor-based power source developed at Space Power Institute. The TAL, designated D-55, is characterized by an external acceleration zone and is powered by a unique chemical double layer (CDL) capacitor bank with a capacitance of 4 F at a charge voltage of 400 V. Performance testing of this power supply on the TAL was conducted at NASA Lewis Research Center in Cleveland, OH. Direct thrust measurements of the TAL were obtained at CDL power levels ranging from 450 to 1750 W. The specific impulse encompassed a range from 1150 s to 2200 s, yielding thruster system efficiencies between 50 and 60%. Preliminary mission analysis of the CDL direct-drive concept and other electric propulsion options was performed for the ORACLE spacecraft in 6am/6pm and 12am/12pm, 300 km sun-synchronous orbits. The direct-drive option was competitive with the other systems by increasing available net mass between 5 and 42% and reducing two-year system wet mass between 18 and 63%. Overall, the electric propulsion power requirements for the satellite solar array were reduced between 57 and 91% depending oil the orbit evaluated The direct-drive, CDL capacitor-based concept in electric propulsion thus promises to be a highly-efficient, viable alternative for satellite operations in specific near-Earth missions.

Hrbud, Ivana↗

The Geoscience Laser Altimeter System (GLAS) for the ICESAT Mission

Accurate measurements of surface heights and atmospheric backscatter have been demonstrated with the SLA, MOLA and LITE space lidar. Recent MOLA measurements of the Mars surface have 40 cm resolution and have reduced the global uncertainty in Mars topography from a few km to approx. 10 m. GLAS is a next generation lidar being developed as part of NASA's Icesat Mission for Earth orbit . The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, determine the height profiles of the Earth's land topography, and profile the vertical backscatter of clouds and aerosols on a global scale. GLAS will fly on a small dedicated spacecraft in a polar orbit at 598 km altitude with an inclination of 94 degrees. GLAS is scheduled to launch in summer 2001 and to operate continuously for a minimum of 3 years with a goal of 5 years. The primary mission for GLAS is to measure the seasonal and annual changes in the heights of the Greenland and Antarctic ice sheets. GLAS will measure the vertical distance to the ice sheet from orbit with 1064 nm pulses from a Nd:Yag laser at 40 Hz. Each 5 nsec wide laser pulse is used for a single range measurement. When over land GLAS will profile the heights of the topography and vegetation. The GLAS receiver uses a I m diameter telescope and a Si APD detector. The detector signal is sampled by an all digital receiver which records each surface echo waveform with I nsec resolution and a stored echo record lengths of either 200, 400, or 600 samples. Analysis of the echo waveforms within the instrument permits discrimination between cloud and surface echoes. Ground based echo analysis permits precise ranging, determining the roughness or slopes of the surface as well as the vertical distributions of vegetation illuminated by the laser, Errors in knowledge of the laser beam pointing angle can bias height measurements of sloped surfaces. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam centroid to about 8 urad is required to achieve 10 cm height accuracy. GLAS uses a stellar reference system (SRS) to determine the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith whose measurements are combined with a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser pulse is measured with a laser reference system (LRS). Optically measuring each laser far field pattern relative to the star camera and gyroscope permits the angular offsets of each laser pulse to be determined. GLAS will also determine the vertical distributions of clouds and aerosols by measuring atmospheric backscatter profiles at both 1064 and 532 nm. The 1064 nm measurements use an analog detector and profile the height and vertical structure of thicker clouds. Measurements at 532 nm use new highly sensitive photon counting detectors, and measure the height distributions of very thin clouds and aerosol layers. With averaging these can be used to determine the height of the planetary boundary layer. The instrument design and expected performance will be discussed.

Abshire, James B.↗

Al-26 in Kenna and other ureilites

A description is presented of the results of a nondestructive analysis conducted with a 42-g slice of the Kenna ureilite. The sample was analyzed in a gamma-gamma coincidence counting system, using a dual-parameter, 4096-channel pulse height analyzer. Data concerning Al-26 and Ne-22/Ne-21 in ureilites and Chassigny are presented in a table. A graph shows the ratio of measured Al-26 activity to that calculated from elemental production rates vs spallation Ne-22/Ne-21 for ureilites and Chassigny. The significance of the data with respect to findings reported by Wilkening et al. (1973) is discussed.

Cressy, P. J.↗

Signal Quality Influence on Averaging Procedure for DIAL Pollution Monitoring

Presented here is an analysis of the relative effect of each stochastic phenomenon on the accuracy of LIDAR measurements. The preferred averaging procedure to be applied is noted. The analysis takes into account the temporal correlation of the transmitted power variations which are associated with laser modal noise, short term temporal correlation of atmospheric turbulence, and 'white' additive noise. A distinction is made between two types of systems, one that transmits a sequence of pulses tuned into two wavelengths, but with a relatively large time separation, and another that transmits pulses in two wavelengths almost coincidentally. This distinction is important because the effect of speckle noise can be minimized when the pulses at two wavelengths are sent within the correlation time of the atmospheric turbulence. The presented analysis compares the signal to noise ratio in the calculation of the ratio beta (sub 1)/beta (sub 2), as achieved by using two methods of calculations: first averaging the data related to each wavelength and then taking the ratio, and first taking the ratio and then averaging. For both methods, normalization with respect to the transmitted power is considered, either prior to or after the averaging of the signals in each wavelength.

Egert, S.↗