Search NASA⌕ Search

SEARCH · Search NASA

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Predicted third-order sweet spots for phi-junction Josephson parametric amplifiers

Hybrid superconductor-semiconductor nanowire Josephson junctions exhibit skewed and phi-shifted current phase relations when an in-plane magnetic field is applied along the weak link's spin-orbit effective field direction. These junctions can have an asymmetric Josephson potential with odd-order nonlinearities. A dominant third-order nonlinearity can be achieved by tuning the magnetic field to a sweet spot. Sweet spots persist when higher order Josephson harmonics are included. This makes it possible to have a single Josephson junction dipole element with three-wave mixing capability, which is favorable for pump-efficient amplification. Electrostatic gate tunability of the semiconductor weak link can make it operable within an extended range of working frequencies, and the inclusion of micromagnets can facilitate near-zero magnetic field operation.

Reza, Tasnum [Univ. of Pittsburgh, PA (United Stat↗

Grating enhanced solid-state laser amplifiers

A novel method and apparatus for suppressing ASE and parasitic oscillation modes in a high average power laser is introduced. Such an invention, as disclosed herein, uses diffraction gratings to increase gain, stored energy density, and pumping efficiency of solid-state laser gain media, such as, but not limited to rods, disks and slabs. By coupling predetermined gratings to solid-state gain media, such as crystal or ceramic laser gain media, ASE and parasitic oscillation modes can be effectively suppressed.

Erlandson, Alvin C↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carnot Analysis of Heat Pump Drying: Ideal Efficiency and Dry Time

Drying processes are important in appliances and in industry, and clothes drying accounts for approximately 3% of residential primary energy consumption in the US. Globally, heat pump tumble dryers (HPD) are increasing their market share against the ubiquitous electric resistance tumble dryer (ERD). In this work, efficiency and dry time limits are defined for ideal HPDs, for both closed air cycle (unvented) and open air cycle (vented). These limits are compared with the limits for ERD. The traditional Carnot efficiency limit for an ideal heat pump, operating between a hot and a cold thermal reservoir, does not apply directly to clothes dryers. One reason dryers require a novel analysis is the presence of additional degrees of freedom, since the hot and cold temperatures are floating, unfixed by ambient conditions. Furthermore, dryers can operate in a closed or open air cycle, and each requires a different analysis. In the closed (unvented) case, the hot and cold temperatures are coupled to each other; while in the open (vented) case, the hot and cold temperatures are both independent free variables. This paper provides an analysis of the fundamental efficiency limits of ERDs and HPDs, which can inform the design and performance limits of evaporative drying technology.

Gluesenkamp, Kyle↗

Simulation of a High Efficiency Multi-bed Adsorption Heat Pump

Attaining high energy efficiency with adsorption heat pumps is challenging due to thermodynamic losses that occur when the sorbent beds are thermally cycled without effective heat recuperation. The multi-bed concept described here effectively transfers heat from beds being cooled to beds being heated, which enables high efficiency in thermally driven heat pumps. A simplified lumped-parameter model and detailed finite element analysis are used to simulate the performance of an ammonia-carbon sorption compressor, which is used to project the overall heat pump coefficient of performance. The effects of bed geometry and number of beds on system performance are explored, and the majority of the performance benefit is obtained with four beds. Results indicate that a COP of 1.24 based on heat input is feasible at AHRI standard test conditions for residential HVAC equipment. When compared on a basis of primary energy input, performance equivalent to SEER 13 or 14 are theoretically attainable with this system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Modeling State Transition and Head-Dependent Efficiency Curve for Pumped Storage Hydro in Look-Ahead Dispatch

As one of the most widely installed utility-scale storage facilities, pumped storage hydro (PSH) plays an essential role in providing flexibility for power systems worldwide. Thus, to accurately quantify the flexibility of PSH units in operational optimization problems is important. The conventional PSH models in the literature rarely consider detailed state transitions due to their hourly-based settings. However, it becomes imperative for operational optimization on short-term intervals, especially with increasing shares of renewable energy in power systems. To this end, this paper presents a novel deterministic PSH model that considers the transition time and trajectory between three states of PSH units in look-ahead dispatch. Moreover, to better characterize the varying efficiency of PSH units with water head and flow rate, this paper proposes to model detailed headdependent efficiency curves (hereafter called input-output curves) in look-ahead dispatch, which encounters heavy computational burdens when short time intervals are applied. In this work, a zig-zag piece-wise linear approximation method is used for input-output curve modeling. This can enable an accurate quantification for variable efficiency and head dependence in a computationally effective manner. Here, numerical results are presented to show performances of the proposed PSH model in both flexibility quantification and computation time.

13 HYDRO ENERGY↗

Population kinetics of laser levels of neodymium ions in POCl{sub 3}-SnCl{sub 4}-{sup 235}UO{sub 2}{sup 2+}-Nd{sup 3+} excited by fission fragments

The population kinetics of laser levels of neodymium ions in the uranium-containing POCl{sub 3}-SnCl{sub 4}-{sup 235}UO{sub 2}{sup 2+}-Nd{sup 3+} laser liquid irradiated in a BARS-6 pulsed reactor is studied experimentally and theoretically. The relations between the populations of the upper and lower laser levels are studied at different time moments with respect to the pump pulse. An inverse population of laser levels is observed and found to be directly proportional to the pump power. The efficiency of pumping of the upper laser level of neodymium ions in the laser medium by uranium fission fragments is determined, and quantitative information is obtained on the inverse population, gain, and their dependences on the pump power. (active media)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Composite and shaped pulses for efficient and robust pumping of disconnected eigenstates in magnetic resonance

Hyperpolarization methods, which can enhance nuclear spin signals by orders of magnitude, open up important new opportunities in magnetic resonance. However, many of these applications are limited by spin lattice relaxation, which typically destroys the hyperpolarization in seconds. Significant lifetime enhancements have been found with “disconnected eigenstates” such as the singlet state between a pair of nearly equivalent spins, or the “singlet-singlet” state involving two pairs of chemically equivalent spins; the challenge is to populate these states (for example, from thermal equilibrium magnetization or hyperpolarization) and to later recall the population into observable signal. Existing methods for populating these states are limited by either excess energy dissipation or high sensitivity to inhomogeneities. Here we overcome the limitations by extending recent work using continuous-wave irradiation to include composite and adiabatic pulse excitations. Traditional composite and adiabatic pulses fail completely in this problem because the interactions driving the transitions are fundamentally different, but the new shapes we introduce can move population between accessible and disconnected eigenstates over a wide range of radio-frequency (RF) amplitudes and offsets while depositing insignificant amounts of power.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling a divertor with mid-leg pumping for high-power H-mode scenarios in DIII-D considering E x B drift flows

Edge-plasma simulations of a baffled, long-legged divertor in DIII-D, performed using the multi-fluid code UEDGE, indicate that the position of the detachment front is constrained to the location of the pump duct along the low-field side (LFS) baffle. Simulations including magnetic and E x B drifts were performed for 12.5 MW deuterium plasmas including intrinsic carbon and seeded neon to assess the optimal location of the LFS divertor pump to create a stable detachment front between the target and the X-point. The radiation front position in the simulations, taken to be indicative of the detachment front, can be controlled between the pump and X-point in the favorable magnetic field direction for H-mode access by moving the pump duct location upstream of the target along the LFS baffle. In the unfavorable magnetic field direction, the radial E θ x B drift flows are directed towards the pumping surface, efficiently removing the injected deuterium gas and limiting the sensitivity of the radiation front location to the gas injection rate. The role of pumping rate and drift direction on the pumping efficiency are also found to affect the divertor plasma conditions and detachment front location in UEDGE simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incentivizing Cold-Climate Efficiency in Juneau (Final Report)

This is the final technical report for the DOE EERE BTO project Incentivizing Cold-Climate Efficiency in Juneau. The project implemented a community energy campaign to deploy heat pumps and efficiency for residents of Juneau, in Southeast Alaska. The project helped Juneau make progress towards its renewable energy goal of reaching 80% renewable energy for space heating by 2045. The Incentivizing Cold-Climate Efficiency in Juneau (ICE-Juneau) project began in 2020 and concluded three years later in 2023. During that time, a group of implementation partners and a research advisory team instituted a beneficial electrification campaign to promote energy savings and carbon reduction in residences of Juneau, Alaska. The campaign, Thermalize Juneau, focused on the installation of single head ductless mini-split heat pumps along with other efficiency upgrades. Thermalize Juneau was the first campaign of its kind in Alaska. After several months of planning, registration opened to the public in early 2021, and over the course of six months 164 participants enrolled. Campaign staff provided education to homeowners on heat pumps and efficiency, and each participant received a one-on-one heat pump assessment using a custom Microsoft Excel-based calculator that estimated energy savings for their residence based on building characteristics and past utility bills. Participants could also obtain a free energy audit from one of the two local energy auditors to further inform their decision. A heat pump installer, electrician, and builder were selected via a competitive RFP process. Participants who felt ready to install a heat pump or other efficiency upgrades received a site visit and custom quote from each of these contractors free of charge, and if they still felt energy upgrades were right for them, could move forward with an individual contract. Participants received a $400 heat pump installation rebate, offered by the installer if 40 heat pump installations occurred through the campaign. Overall, the campaign facilitated 75 heat pump installations (including participants that went with another contractor or heat pump model) and 30 efficiency upgrades (including participants that went with another builder or did DIY upgrades). The campaign created 3 new jobs as the heat pump installer hired an administrative assistant and two apprentices over the course of the campaign. It also helped Juneau work toward achieving its renewable energy goal of 80% renewable energy for space heating by 2045 by upgrading houses from fuel oil to heat pumps powered by the hydropower electric grid. Researchers conducted four surveys to inform Thermalize Juneau and future energy campaigns. The first surveyed existing and prospective heat pump owners in Juneau to identify barriers the campaign could address and inform recruitment efforts. Entry and exit surveys provided information on participant demographics, goals, outcomes, and suggestions for improving future campaigns. And a final survey of community members who had not participated in Thermalize Juneau gave insight on ways future campaigns could include a greater diversity of participants so they could realize similar benefits. Researchers also used pre-campaign energy modeling to predict energy savings, which was then compared to the savings estimated through aggregation of heat pump assessments and energy audits, and later to actual energy savings of 10 participants who installed a heat pump and were able to provide complete energy use data sets. In addition to energy savings, and to assist the electric utility in future planning efforts, researchers analyzed the overall change in electric use across participants with energy data and heat pump installations. They also completed a life cycle cost analysis, showing positive net present values for those displacing a fuel oil appliance, and a more mixed case for those switching from electric baseboard. This project proved the feasibility of energy campaigns, with a goal of beneficial electrification, in cold, remote locations. The Thermalize Juneau team compiled a Guidebook to Thermalize Campaigns, available online. In addition to documenting what occurred in Alaska’s first thermalize campaign, it provides tips and resources for other communities wishing to implement a similar program.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of pump geometry on the generation efficiency of an alkali metal vapour laser

The influence of pump geometry on the generation efficiency of a transversely diode-pumped alkali metal vapour laser is studied theoretically. Analytical formulas describing the operation of a high-intensity laser with double-sided diode pumping in two orthogonal directions are obtained. It is shown that the generation efficiency of an alkali metal vapour laser can be increased by 8% – 18% when switching from single-sided to double-sided pumping. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recovery Act: Tennessee Energy Efficient Schools Initiative Ground Source Heat Pump Program

The Tennessee Energy Efficient Schools Initiative (EESI) Hybrid-Water Source Heat Pump (HY-GSHP) Program sought to provide installation costs and operation costs for different Hybrid water source heat pump systems’ configurations so that other State of Tennessee School Districts will have a resource for comparison purposes if considering a geothermal system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gratings for Increasing Solid-State Laser Gain and Efficiency

We introduce new concepts for increasing the efficiency of solid state lasers by using gratings deposited on laser slabs or disks. The gratings improve efficiency in two ways: (1) by coupling out of the slab deleterious amplified spontaneous emission (ASE) and (2) by increasing the absorption efficiency of pump light. The gratings also serve as antireflective coatings for the extracting laser beam. To evaluate the potential for such coatings to improve laser performance, we calculated optical properties of a 2500 groove/mm, tantala-silica grating on a 1cm x 4cm x 8cm titanium-doped sapphire slab and performed ray-trace calculations for ASE and pump light. Our calculations show substantial improvements in efficiency due to grating ASE-coupling properties. For example, the gratings reduce pump energy required to produce a 0.6/cm gain coefficient by 9%, 20% and 35% for pump pulse durations of 0.5 {micro}s, 1{micro}s and 3{micro}s, respectively. Gratings also increase 532-nm pump-light absorption efficiency, particularly when the product slab overall absorption is small. For example, when the single-pass absorption is 1 neper, absorption efficiency increases from 66%, without gratings, to 86%, when gratings are used.

42 ENGINEERING↗

Final amplifier of an ultra-intense all-OPCPA system with 13-J output signal energy and 41% pump-to-signal conversion efficiency

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 × 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. The seed beam (180-nm bandwidth, 110 mJ) was provided by the preceding OPCPA stages. A maximum pump-to-signal conversion efficiency of 41% and signal energy up to 13 J were achieved with a 52-mm-long DKDP crystal due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape.

47 OTHER INSTRUMENTATION↗