Search NASA⌕ Search

SEARCH · Search NASA

Results for “pumping test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Flow Sensor Test Article (F-STAr) - Status Report for FY2021

This report will review updates on the status of F-STAr. First, the report will describe a general overview of the test article and how each component interacts. Then, each main component will be discussed in a deep dive section which will review the design and other relevant details. F-STAr components which are discussed in more detail include the 120 GPM-pump, the support structure and test sections, 5 kW-heater, the 2 kW-cooler and cooling system, and the submersible flowmeter. Finally, this report will conclude with a brief recap and a bulleted outline of the path moving forward.

42 ENGINEERING↗

Model-based predictive control of multi-stage air-source heat pumps integrated with phase change material-embedded ceilings

This paper presents a model-based predictive control strategy to optimize the operations of phase change material (PCM) ceiling panels coupled with a multi-stage air-source heat pump. A three-stage prototype heat pump unit has been built and tested in the laboratory, with the low and medium stages designed for space heating/cooling and the high compression stage dedicated to charging of the PCM energy storage. To facilitate optimal control of the integrated heat pump system, a mixed-integer linear programming formulation is derived through linearization of the heat pump model and a mixed-integer reformulation of the PCM dynamic governing equations. A predictive control strategy is synthesized based on the resultant control formulation and implemented in a receding horizon scheme that optimizes the PCM charging and the zone temperature schedules simultaneously to leverage both the passive (associated with building construction materials) and active (PCM) storage capacities of a building. The control strategy has been tested along with three benchmarking control scenarios using a co-simulation platform for a prototypical detached house in Atlanta, GA. In this study, test results showed that application of the proposed control strategy to the PCM-integrated heat pump could provide 27.1% electricity cost savings while a fine tuned rule-based control strategy could achieve cost savings of 20.4%, compared to a baseline case without PCM storage, under a time-of-use rate tariff.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a High-Pressure Fuel Injection System for Use with Propane-DME

Paper details the design approach and performance of a high-pressure common rail fuel injection system used with Propane-DME mixtures targeting high injection pressures on a light duty 2.2L inline-4 compression ignition engine. The study estimates the bulk modulus of elasticity based on the hardware geometry and operating pressures to assess the compressibility of Propane and DME across a range of pressures typical of the LD engine application. The compressibility factor ranges from 500 to 3000 bar, significantly lower than the theoretical values for the conditions tested. The high-pressure pump performance is optimized via the implementation of an inlet metering valve operated on a crank-angle open/close sequence to control pressure at the common rail. The application of a model-based controller and the use of high-speed sampling of rail pressure indicate that pressure at the rail can be attained with the pump metering valve, and without use of the pressure relieve valve present in the rail. Results show a significant reduction on pumping work parasitics and of fuel heating, on the order of 40°C, at typical working conditions with the proposed approach. Injector rates of injection with Propane-DME are very similar to those of Diesel. Paper compares bench data of rates of injection versus simulation predictions across operating pressures of 200 to 1000bar and from injection commands spanning 0.20 to 2.0ms. Furthermore, the accuracy of the model predictions are attributed in part by to the updated fuel compressibility modulus descriptions attained during the testing.

42 ENGINEERING↗

ComStock Measure Scenario Documentation: Laboratory-Informed Modeling of Standard Performance Heat Pump Rooftop Units

This measure scenario replaces gas and electric resistance RTUs in the U.S. commercial building stock with standard efficiency commercial off the shelf heat pump rooftop units. This study uses performance data informed by NREL laboratory testing of a standard efficiency 7.5-ton heat pump RTU. This is the key distinction between this measure scenario and a similar ComStock measure scenario - Standard Performance Heat Pump Rooftop Units - that uses published manufacturer data tables to inform performance. These two scenarios are compared in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of spatial dynamics and point kinetics approaches in multiphysics modeling of the molten salt reactor experiment

In this work, we present validation test results of fully coupled neutronics and thermal-hydraulics models of the Molten Salt Reactor Experiment (MSRE) against experimental data of the zero power pump transients and the natural circulation tests at low power. To capture the strong coupling between neutronics and thermal-hydraulics due to fuel circulation, and to account for the delayed neutron precursor (DNP) distribution, the porous media thermal-hydraulics solver Pronghorn was fully coupled to the spatial neutron dynamics code Griffin, which solves the neutron diffusion equation, and to the 0-D point kinetics solver Squirrel, using a 2-D homogenized representation of the MSRE. The validation test results show very good agreement with experimental data for both point kinetics and spatial dynamics simulations, capturing the strong feedback effect and DNP losses in the MSRE. The 0-D code Squirrel accurately predicted the time-dependent behavior in the MSRE given the steady-state spatial dynamics solution of Griffin.

42 - ENGINEERING↗

Origin of metal-insulator transitions in the parent compounds of ruthenium-pnictide superconductors

Here we study the interplay of the structural phase transition, flat electronic band dispersion, and metal-to-insulator transition (MIT) in the parent compounds of the Ru-pnictide superconductors by using first-principles calculations. Our electron and phonon calculations reveal that Ru(P,As) undergo MIT accompanied by orthorhombic to monoclinic distortion at low temperature, but RuSb stays orthorhombic and metallic in agreement with the experimental findings. It is demonstrated that electronic correlation, as treated in DFT + U, DFT + Gutzwiller, and dynamical mean-field theory (DMFT), cannot induce MIT in the undistorted crystal structure. We find that, although small monoclinic distortion can remove the van Hove singularity at the Fermi level, it does not immediately gap out the Fermi surface and a large value of monoclinic distortion is necessary for a clear MIT, suggesting the possibility of an intermediate pseudogapped monoclinic metallic phase. Furthermore, we predict a light-induced two-step insulator-to-metal and structural transitions in the monoclinic phases of RuP and RuAs, which can be tested in future ultrafast pump-probe experiments as an alternative ideal playground to VO 2 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Enabling Entrained-Flow Gasification of Blends of Coal, Biomass and Plastics (Final Report)

This project demonstrated the technical feasibility of gasifying blends of coal, biomass and mixed waste plastics in a high pressure entrained-flow gasifier for production of hydrogen. This was achieved by creating slurries of coal, biomass pyrolysis liquids and liquefied plastic oil. Specific objectives of the project included (1) determining compositions of coal-biomass-plastic mixtures that produce a stable slurry suitable for pumping to high pressure, (2) designing and testing a novel burner to effectively atomize the mixed feedstock slurry in a pressurized gasifier, and (3) acquiring first-of-a-kind performance data for pressurized, oxygen-blown entrained-flow gasification of slurried blends of coal, biomass and plastic. A key focus of the project was preparation of mixtures of coal, biomass and plastic. To facilitate easy pumping to high pressure, slurries were created using (i) bioliquid resulting from a well-established rapid thermal treatment pyrolysis process, (ii) oil produced from waste plastic via an available thermal conversion process, and (iii) ground coal. Lab-scale tests were conducted to evaluate viscosity and stability/propensity for the mixtures to separate over time. Larger batches of the most promising slurry compositions were prepared and subjected to pumping studies. It was found that mixtures containing less than about 40% coal and less than about 30% plastic oil were stable and of low enough viscosity to facilitate pumping to high pressure. A high-performance hot oxygen burner (HOB) was designed and fabricated for use in an existing 1 ton/day pressurized entrained-flow gasifier. Ex-situ testing demonstrated that the HOB provides excellent atomization of the slurries and creates a very uniform and robust flame. Performance of the HOB in the gasifier was exceptional and resulted in better conversion to syngas than any previous generation of burner. Fabricating the HOB for this project was challenging due to the relatively small scale of the gasifier. Performance in larger-scale systems is expected to be even better. Gasification of mixtures of coal, bioliquid and plastic oil proved to be relatively easy. The gasifier was able to be started up, pressurized and transitioned to the blended slurry feedstock with no technical difficulty. Syngas rich in CO and H 2 , with relatively low concentrations of CO 2 , was produced. During startup and at low gasification temperatures, soot formation was observed, as is typical for gasification of petroleum-based feedstocks. No slag buildup was observed under the conditions tested. The project was successful in demonstrating the technical feasibility of the concept. Future development should broaden the range of feedstocks under consideration, more deeply explore performance of the gasifier, and evaluate scale-up and implementation strategies.

08 HYDROGEN↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The molten salt tritium transport experiment: A pumped fluoride salt loop for hydrogen isotope experimentation

Molten salt reactors (MSRs) and fusion reactors propose to use molten salts as coolants and breeder blanket materials, respectively. Tritium, however, poses safety concerns in both reactor types due to its ability to permeate through reactor materials and potential for environmental release. This manuscript addresses the tritium transport phenomena in molten salts and presents the design and analysis of the Molten Salt Tritium Transport Experiment (MSTTE). MSTTE is a forced-convection fluoride salt loop intended to measure hydrogen isotope permeation through structural materials in a flowing salt system. In the first phase, MSTTE will use FLiNaK salt and deuterium as surrogates for FLiBe and tritium, with future plans to utilize tritium and FLiBe. MSTTE couples a Copenhagen Atomics pumped salt loop with an external test section that introduces hydrogen isotopes into the loop and measures transport phenomena. The Hydrogen Injection System (HIS) controls hydrogen isotope introduction into the molten salt loop. Here, the permeation test section measures the permeation rate through stainless steel tubing in contact with flowing salt. Computational fluid dynamics (CFD) analysis ensures fully developed salt flow in the permeation test section. MSTTE is modeled with MELCOR-TMAP to predict the permeation rate as a function of experimental variables such as source term, salt flow rate, and salt temperature. Results indicate that the source term is the only parameter with a significant effect on the permeation rate. Pressure drop analysis suggests that the loop should operate below 200 LPM to maintain a pressure drop below 200 kPa. Additionally, finite-element analysis assesses thermal stress during loop operation to ensure the experiment's safe design. MSTTE will provide semi-integral data on tritium transport phenomena in molten salts and serve as a testbed for advancing molten salt technology.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Off-harmonic optical probing of high intensity laser plasma expansion dynamics in solid density hydrogen jets

Due to the non-linear nature of relativistic laser induced plasma processes, the development of laser-plasma accelerators requires precise numerical modeling. Especially high intensity laser-solid interactions are sensitive to the temporal laser rising edge and the predictive capability of simulations suffers from incomplete information on the plasma state at the onset of the relativistic interaction. Experimental diagnostics utilizing ultra-fast optical backlighters can help to ease this challenge by providing temporally resolved inside into the plasma density evolution. We present the successful implementation of an off-harmonic optical probe laser setup to investigate the interaction of a high-intensity laser at 5.4 x 10 21 W/cm 2 peak intensity with a solid-density cylindrical cryogenic hydrogen jet target of 5μm diameter as a target test bed. The temporal synchronization of pump and probe laser, spectral filtering and spectrally resolved data of the parasitic plasma self-emission are discussed. The probing technique mitigates detector saturation by self-emission and allowed to record a temporal scan of shadowgraphy data revealing details of the target ionization and expansion dynamics that were so far not accessible for the given laser intensity. Plasma expansion speeds of up to (2.3 ± 0.4)x 10 7 m/s followed by full target transparency at 1.4ps after the high intensity laser peak are observed. A three dimensional particle-in-cell simulation initiated with the diagnosed target pre-expansion at -0.2ps and post processed by ray tracing simulations supports the experimental observations and demonstrates the capability of time resolved optical diagnostics to provide quantitative input and feedback to the numerical treatment within the time frame of the relativistic laser-plasma interaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of the edge stochastic layer in density pump-out by resonant magnetic perturbations

The role of the edge stochastic layer on particle transport is addressed in DIII-D plasmas with applied resonant magnetic perturbations (RMPs) causing density pump-out (a term used to denote the density reduction at the top of the pedestal due to the applied RMPs). Using an analytical model that adds the stochastic parallel transport of electrons (Harvey et al 1981 Phys. Rev. Lett. 47 102) to the fluid equations, the ambipolar radial electric field and particle flux are calculated simultaneously. In this model the nonambipolar electron particle flux, driven by the stochastic magnetic field, is predominantly balanced by the nonambipolar perpendicular ion flux, driven by toroidal viscosity, across a narrow stochastic layer of order two percent of the plasma radius (0.98 < ψn < 1). The model reproduces the level of density pump-out and its dependence on RMP amplitude near the separatrix for three plasma discharges for which the pedestal foot is at medium to high collisionality $(2\leqslant {\nu }_{\text{sep}}^{\ast }\leqslant 30)$. In this work, the experimentally observed and numerically tested inverse density dependence of density pump-out (Hu et al 2020 Nucl. Fusion 60 076001) is accurately captured by the model: an increase in collisionality with density in the pedestal foot results in a decrease in stochastic diffusivity, and hence a decrease in the level of pump-out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SAM Code Enhancements for Modeling of Liquid Metal-Cooled Fast Reactor Concepts

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. This report summarizes two major efforts in addressing the modeling gaps in SAM for liquid-metal-cooled fast reactor (LMFR) applications, i.e. thermal mixing and stratification phenomena in large pools and corrosion-oxidation of components in flowing lead. A new one-dimensional model for thermal mixing and stratification effects in large pools and enclosures is developed and implemented. Thermal mixing and stratification occur when fluid enters a pool at a temperature different than the bulk fluid itself, a scenario often encountered during transients in pool-type systems. These phenomena are critical for the safety of reactors, impacting phenomena like natural circulation, which is essential for passive cooling. The improved model in SAM addresses limitations of state-of-the-art approaches by combining one-dimensional (1D) channels, representing the coolant jet flow, with lumped-parameter zero-dimensional (0D) pools, representing the rest of coolant in the tank. Energy exchange between the 1D jet and the 0D pools is based on heat transfer correlations calibrated against 3D simulations. It is verified that this model can handle various flow configurations, including hot jets in colder pools, cold jets in hotter pools, and the presence of features like ceilings, free surfaces, and obstacles. Additionally, validation against experimental data demonstrates the ability of the model to capture mixing and stratification effects in a wide range of conditions. The flexibility and improved accuracy of the new model make it a valuable tool for reactor safety analysis, allowing for the simulation of different geometries encountered in advanced reactors. A system-level corrosion modeling capability is developed and implemented in SAM to support Lead Fast Reactor (LFR) development. Although the initial focus of this capability will be on LFR application, this can later be expanded to include other liquid metals such as Lead-Bismuth Eutectic (LBE) and PbLi. This report summarizes the common corrosion mitigation strategies and outlines the progress on implementing and validating a corrosion-oxidation model in SAM. Verification and validation of the corrosion-oxidation portion of the model was performed using analytical solution and measured data from samples tested in the non-isothermal pumped lead loop at IPPE Obninsk. The iron transport and corrosion/precipitation portion of the model was assessed using an analytical model and measured corrosion depths from a natural convection lead loop experiment performed at CEA. It is demonstrated that the model implemented in SAM performed well in these assessments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗