Search NASA⌕ Search

SEARCH · Search NASA

Results for “pyrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Correction-free radiometry on specular spheres for containerless processing in microgravity

An analysis is presented that establishes how correction-free radiance measurements or pyrometry can be performed on targets in furnaces where there may be significant additional radiance from heated furnace walls or from reflecting surfaces close to the target. These configurations are common in microgravity and containerless processing applications where a specular target is radiantly heated in a hot-wall furnace, or inductively heated from the fields arising from nearby closely spaced electromagnetic coils. Proper design requires that the pyrometer does not view any images of the background features in the specular target so that stray radiation will not be reflected into the viewing optics of the pyrometer. To analyze the problem, conventional paraxial optics analysis is shown to be significantly in error. Instead a method of nonparaxial ray tracing, based on the derivatives of the ray paths, shows how the images must be located. This leads to analytical results that can be used to design such systems. The findings are applied to the furnace geometries that are presently being considered for flight in LEO.

Thomas, A. S. W.↗

Pyrometric Gas and Surface Temperature Measurements

A multiwavelength pyrometer possessing advantages over the one- and two-wavelength designs is described. Results of its application to surface temperature measurements of ceramics is presented. Also described is a probe suitable for gas temperature measurements to temperatures > 2600 K. The design of the probe includes a multiwavelength pyrometer with fiber optic input.

Fralick, Gustave↗

Broadband IR Measurements for Modis Validation

The primary objective of this research was the development and deployment of autonomous shipboard systems for infrared measurement of ocean surface skin temperature (SST). The focus was on demonstrating long-term, all-weather capability and supplying calibrated skin SST to the MODIS Ocean Science Team (MOCEAN). A secondary objective was to investigate and account for environmental factors that affect in situ measurements of SST for validation of satellite products. We developed and extensively deployed the Calibrated, InfraRed, In situ Measurement System, or CIRIMS, for at-sea validation of satellite-derived SST. The design goals included autonomous operation at sea for up to 6 months and an accuracy of +/- 0.1 C. We used commercially available infrared pyrometers and a precision blackbody housed in a temperature-controlled enclosure. The sensors are calibrated at regular interval using a cylindro-cone target immersed in a temperature-controlled water bath, which allows the calibration points to follow the ocean surface temperature. An upward-looking pyrometer measures sky radiance in order to correct for the non-unity emissivity of water, which can introduce an error of up to 0.5 C. One of the most challenging aspects of the design was protection against the marine environment. A wide range of design strategies to provide accurate, all-weather measurements were investigated. The CIRIMS uses an infrared transparent window to completely protect the sensor and calibration blackbody from the marine environment. In order to evaluate the performance of this approach, the design incorporates the ability to make measurements with and without the window in the optical path.

Jessup, Andrew T.↗

Thermal Conductivity Change Kinetics of Ceramic Thermal Barrier Coatings Determined by the Steady-State Laser Heat Flux Technique

A steady-state laser heat flux technique has been developed at the NASA Glenn Research Center at Lewis Field to obtain critical thermal conductivity data of ceramic thermal barrier coatings under the temperature and thermal gradients that are realistically expected to be encountered in advanced engine systems. In this study, thermal conductivity change kinetics of a plasma-sprayed, 254-mm-thick ZrO2-8 wt % Y2O3 ceramic coating were obtained at high temperatures. During the testing, the temperature gradients across the coating system were carefully measured by the surface and back pyrometers and an embedded miniature thermocouple in the substrate. The actual heat flux passing through the coating system was determined from the metal substrate temperature drop (measured by the embedded miniature thermocouple and the back pyrometer) combined with one-dimensional heat transfer models.

Zhu, Dongming↗

Thermal History Mapping Technology for Turbine Engine Diagnostics

The infusion of ceramic matrix composites (CMCs) in next generation gas turbines represents daunting challenges as the failure of protective coating, known as Environmental Barrier Coating (EBC), means little remnant life of CMC components. Consequently reliable lifing is critical to the success of CMC components. Accurate thermal mapping of EBC in rig and engine test is of paramount importance because temperature is the most critical variable for EBC life. Current temperature measurement technologies include thermocouples, pyrometers, IR cameras, and thermal paints. Thermocouples require a passage to access the components and pyrometers and IR cameras require line-of-sight. Thermal paints are based on color-sensitive pigments that visually indicate the temperature that a component experienced. Thermal paints do not require line-of-sight, however, they have a low resolution and a limited temperature capability (~1400°C). Thermal history coating is based on oxide ceramic which luminesces when excited with a light source. The luminescence changes when the material's structure changes triggered by heat impact. The maximum temperature to which the material was exposed can be determined from the luminescence change. This paper describes the principles of this new technique and demonstrates its capabilities for EBCs exposed to excess of 1500°C.

Lee, Kang N.↗

Shock Temperatures in Calcite at 115 to 185 GPa

We present optical pyrometer measurements of shock temperatures in crystalline calcite (CaC03) which constrain its behavior in shock waves with amplitudes of 115 to 185 GPa.

shock temperatures optical pyrometer crystalline c↗

Temperature Distributions in Hollow Cathode Emitters

Life-limiting processes in hollow cathodes are determined largely by the temperature of the emitter. To support development of cathode life models we have developed a noncontact temperature measurement technique which employs a stepper motor-driven fiber optic probe. The probe is driven inside the hollow cathode and collects light radiated by the hot interior surface of the emitter. Ratio pyrometry is used determine the axial temperature profile. Thermocouples on the orifice plate provide measurements ofthe external temperature during cathode operation and are used to calibrate the pyrometer system in situ with a small oven enclosing the externally heated cathode. Initial measurements of the temperature distribution in a hollow cathode with the same geometry as a cathode that failed after operating at 12 A emission current for 27800 hours are discussed.

ratio pyrometer system↗

HOT SPIN-AND-BURST TEST METHODS FOR AIRCRAFT TURBINE WHEELS

Methods are described for suspension-system vibration damping, automatically controlled induction heating through radiation pyrometers, rotating-disk temperature measurement, and unattended operation with a safety-interlock system.

BURST↗

STUDY OF PURIFICATION OF WATER FROM BIOLOGICAL WASTE.

All the recent data accumulated for the recovery of potable water from metabolic waste have been obtained from the accordian pleated self-heating catalyst. Potable water was obtained in the preliminary runs. Optical pyrometer readings of the furnace temperature were obtained through the side wall of the quartz reactor tube. No further conclusions have been made regarding the correlations between the low pH and high flow rate of the original unit.

PURIFICATION↗