Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

Review of Technical Photovoltaic Key Performance Indicators and the Importance of Data Quality Routines

Technical key performance indicators (KPIs) are important metrics used to assess and quantitatively summarize various aspects of photovoltaic (PV) systems, including long-term performance, economic viability, and carbon footprint. Herein, a group of experts of the International Energy Agency's Photovoltaic Power Systems Programme Task 13 collect and describ the most important technical KPIs used in the industry. Thereby, a set of best practices for reliably handling PV system data is presented and the impact of data quality and climatic variability on KPI calculation is investigated. Further, the effective use of technical KPIs allows triggering data-driven and informed decisions to optimize PV systems and providing a comprehensive overview of how PV systems operate across different conditions and climates. With the worldwide growth of the PV industry, more companies operate/own PV systems in different regions, where the climatic and seasonal profiles differ. This requires context-aware evaluation of KPIs, or the judicious application of multiple KPIs, to ensure that each asset is evaluated correctly. Beyond that, there is untapped potential in the utilization of KPIs through geospatial mapping and extrapolation of fleet KPIs. This study demonstrates that the uncertainty in KPI estimation is not well understood and depends on data quality, climatic variability, and system configuration.

14 SOLAR ENERGY↗

Quantitative Comparisons of Image Quality for Flash X-Ray Detectors

Due to X-rays’ ability to penetrate materials, flash X-ray radiography can be used for high-speed measurements where direct optical access is not possible. Choice of detector has a pronounced impact on resulting image quality. Four different detector systems were evaluated with a 450kVp flash source to quantitatively compare image quality metrics. The scintillating digital detector had less image noise than the three different storage phosphor computed radiography detectors across all transmission levels, but lacked the spatial resolution of the computed radiography detectors. For the screens tested here, the HPX-DR digital system had the highest signal to noise ratio of 68.24 and contrast to noise ratio of 35.53, but had the lowest spatial resolution, resolving 2.5 line pairs per millimeter at 1.78% contrast. At a value of 37.59, the Flex GP imaging plate had a signal to noise value above its storage phosphor counterparts under a 450kVp flash source. For radiographic setups typically used for dynamic experiments, the Flex XL Blue and Flex HR detectors had signal to noise ratios of 18.44 and 26.56 respectively. The highest resolved spatial frequencies of the Flex GP, Flex XL Blue, and Flex HR with the flash source are 3.85, 5.00, and 3.85 line pairs per millimeter, respectively. In conclusion, the Flex GP detector had the best combination of signal to noise ratio, contrast to noise ratio, and spatial resolution under a flash source.

computed radiography↗

Bayesian modeling of traffic-related air pollutants: A case study of urban transportation and air quality dynamics in Columbia, South Carolina

Traffic emissions significantly impact near-road air quality and public health. This research applies a Bayesian modeling framework to investigate these impacts using high-resolution traffic and air pollutant data from an urban corridor in Columbia, South Carolina. Despite a data collection period truncated by the COVID-19 lockdown, the Bayesian approach successfully identified significant predictors and quantified model uncertainty. Employing Bayesian Model Selection and Averaging enhanced prediction accuracy and evaluated model uncertainty. Findings indicate that higher temperatures and increased moisture levels elevate particulate matter (PM 1.0 , PM 2.5 , PM 10 ) concentrations, while traffic speed significantly affects nitrogen dioxide (NO 2 ) levels. Specifically, higher average traffic speeds (indicative of smoother flow) correspond to lower NO 2 concentrations, suggesting that less congested conditions reduce NO 2 emissions. This study highlights the robustness of Bayesian methods for generating reliable air quality insights even under data-constrained conditions. The findings underscore the importance of traffic flow management (e.g., reducing congestion) for mitigating near-road NO 2 exposure and provide a basis for developing targeted public health strategies.

54 ENVIRONMENTAL SCIENCES↗

UR 2 : Ultra-rapid reactivity test for real-time, low-cost quality control of calcined clays

To reduce cement's carbon footprint, there is growing interest in commercial adoption of sustainable SCMs such as calcined clays. However, the existing ASTM standard (R 3 test, C1897) to test the reactivity of such clays takes up to 7 days and cannot be used for real-time quality control in an industrial setting. We address this issue by introducing a 5-min Ultra-Rapid Reactivity (UR 2 ) test. By dissolving 47 clay specimens in 4 M NaOH solutions at 90°C, we report that a dissolution index of 1.54Al + Si correlates strongly to the 7-day R 3 heat (R 2 = 0.92, RMSE = 94.1 J/g). This dissolution index also correlates to the 28-day compressive strength for 14 clay mixtures (R 2 = 0.94, RMSE = 1.7 MPa). This UR 2 test relies on colorimetry and can be conducted via off-the-shelf, low-cost cameras. Overall, our new UR 2 test opens a pathway for real-time, low-cost quality control of calcined clays.

36 MATERIALS SCIENCE↗

Sensitivity of Regional WRF‐Chem Air Quality and Weather Simulations to Biomass‐Burning Emission Data Sets: A Case Study of the Impact of Canadian Wildfire on the US°

This study focuses on the period from June 26 to 29, 2023, when record‐breaking Canadian wildfires severely impacted air quality in the Midwest United States. Using the Weather Research and Forecasting Model with Chemistry (WRF‐Chem) and four biomass‐burning data sets (Fire Inventory from NCAR version 1, Fire Inventory from NCAR version 2.5, Quick Fire Emissions Data set [QFED], and Regional ABI‐VIIRS Emission), we analyzed aerosol transport from Canada to the US and assessed the model's accuracy in predicting PM 2.5 , O 3 , CO and aerosol weather feedback. Model simulations were compared with ground‐based and remote sensing observations as well as field measurements from the Community Research on Climate and Urban Science (CROCUS) project. Our findings show that the movement of a low‐pressure system from the Great Lakes to the Atlantic, combined with the high‐pressure system over the Atlantic, caused the transport of aerosols from Canadian wildfires to the US. Results show WRF‐Chem significantly underestimated key atmospheric components: aerosol optical depth (AOD) by over 50%, PM 2.5 by 65%–90% and peak O 3 concentrations by 50%–55% across four biomass burning data sets. Additionally, CO and NO 2 concentrations were underpredicted. The substantial underestimation of PM 2.5 led to an overestimation of temperature by up to 3.6 °C primarily due to excessive downward shortwave radiation, which resulted from the underestimation of direct aerosol effects and an increase in sensible heat flux. Among the biomass‐burning data sets, QFED produced the most accurate AOD and PM 2.5 predictions due to improved wildfire emission estimates, leading to a 1.0 to 1.5 °C reduction in temperature overestimation during the daytime. These findings underscore the need for improving wildfire emission estimates for trace gases and aerosols to enhance air quality and weather feedback predictions.

WRF-chem model↗

Thermal and photoinduced chemistry of the aromatic Criegee intermediate, benzaldehyde oxide: Implications for indoor air quality

Essential oils contain a complex mixture of volatile organic compounds, ranging from terpenes to aromatics. When released into the indoor air environment or into the atmosphere, they may undergo oxidation to generate complex reactive intermediates that affect indoor air quality. Cinnamaldehyde is one such aromatic molecule that is abundant in essential oils. When released into the indoor air environment, it may undergo oxidation to form a carbonyl oxide (Criegee intermediate) with an aromatic substituent: benzaldehyde oxide. In this manuscript, we present a high-level quantum chemical study that shows that, unlike smaller atmospherically relevant Criegee intermediates, benzaldehyde oxide is expected to undergo solar photolysis on timescales that are competitive with its ground state unimolecular and bimolecular chemistry. We show that aromatic substitution leads to a drastic bathochromic shift in the spectroscopically relevant excited states, revealing that photolysis in the indoor or outdoor environment should not be neglected when modeling the climate and air quality implications of Criegee intermediates with extended conjugation. Here, we predict a range of products that may be important for forming lower volatility compounds via tropospherically relevant photochemistry. To motivate future experimental validation of our results, we propose a viable synthetic procedure of the relevant precursor for generating and stabilizing benzaldehyde oxide.

atmospheric photochemistry↗

Studying Aerosol, Clouds, and Air Quality in the Coastal Urban Environment of Southeastern Texas

A multi-agency succession of field campaigns was conducted in southeastern Texas during July 2021 through October 2022 to study the complex interactions of aerosols, clouds and air pollution in the coastal urban environment. As part of the Tracking Aerosol Convection interactions Experiment (TRACER), the TRACER- Air Quality (TAQ) campaign the Experiment of Sea Breeze Convection, Aerosols, Precipitation and Environment (ESCAPE) and the Convective Cloud Urban Boundary Layer Experiment (CUBE), a combination of ground-based supersites and mobile laboratories, shipborne measurements and aircraft-based instrumentation were deployed. These diverse platforms collected high-resolution data to characterize the aerosol microphysics and chemistry, cloud and precipitation micro- and macro-physical properties, environmental thermodynamics and air quality-relevant constituents that are being used in follow-on analysis and modeling activities. We present the overall deployment setups, a summary of the campaign conditions and a sampling of early research results related to: (a) aerosol precursors in the urban environment, (b) influences of local meteorology on air pollution, (c) detailed observations of the sea breeze circulation, (d) retrieved supersaturation in convective updrafts, (e) characterizing the convective updraft lifecycle, (f) variability in lightning characteristics of convective storms and (g) urban influences on surface energy fluxes. The work concludes with discussion of future research activities highlighted by the TRACER model-intercomparison project to explore the representation of aerosol-convective interactions in high-resolution simulations.

54 ENVIRONMENTAL SCIENCES↗

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES↗

Defining Golden Batches in Biomanufacturing Processes From Internal Metabolic Activity to Detect Process Changes That May Affect Product Quality

ABSTRACT Cellular metabolism plays a role in the observed variability of a drug substance's Critical Quality Attributes (CQAs) made by biomanufacturing processes. Therefore, here we describe a new approach for monitoring biomanufacturing processes that measures a set of metabolic reaction rates (named Critical Metabolic Parameters (CMP) in addition to the macroscopic process conditions currently being used as Critical Process Parameters (CPP) for biomanufacturing. Constraint‐based systems biology models like Flux Balance Analysis (FBA) are used to estimate metabolic reaction rates, and metabolic rates are used as inputs for multivariate Batch Evolution Models (BEM). Metabolic activity was reproducible among batches and could be monitored to detect a deliberately induced macroscopic process shift (i.e., temperature change). The CMP approach has the potential to enable “golden batches” in biomanufacturing processes to be defined from the internal metabolic activity and to aid in detecting process changes that may impact the quality of the product. Overall, the data suggested that monitoring of metabolic activity has promise for biomanufacturing process control.

Biotechnology & Applied Microbiology↗

The effect of filament peaking on electron beam weld quality

Electron beam welding uses high intensity beams that are generated by an electron emitting cathode under high vacuum conditions. The cathode, typically a ribbon or wire filament of refractory metal, must be heated to sufficiently high temperatures for electron emission to occur and must be carefully controlled to produce the desired beam current while at the same time optimizing filament lifetime. Traditional methods for doing this in commonly used triode gun assemblies consist of first finding the filament knee point in the filament current versus beam current relationship that produces the desired beam current for a given beam voltage. The filament current is then increased by some amount, typically 5–10%, per conventional wisdom to produce a peaked beam. This investigation studies and quantifies the beam and weld quality produced by underkneed and overpeaked filaments using electron beam diagnostics to measure the power density distribution of these beams. Underkneed filaments are shown to have power densities that drop off very quickly below the traditional knee, resulting in poor weld penetration. Kneed filaments do not reach the full beam intensity and also produce shallow welds. Increasing the filament current 10% above the traditional knee was shown to produce a circular Gaussian-like beam with peaked intensity optimized for welding and for filament lifetime. Further increases in the filament current that produce overpeaked beams do not significantly change the beam or weld quality and would only contribute to a reduced filament lifetime.

Electron Beam Welding↗

Deep reinforcement learning control for co-optimizing energy consumption, thermal comfort, and indoor air quality in an office building

With the recent demand for decarbonization and energy efficiency, advanced HVAC control using Deep Reinforcement Learning (DRL) becomes a promising solution. Due to its flexible structures, DRL has been successful in energy reduction for many HVAC systems. However, only a few researches applied DRL agents to manage the entire central HVAC system and control multiple components in both the water loop and the air loop, owing to its complex system structures. Moreover, those researches have not extended their applications by incorporating the indoor air quality, especially both CO2 and PM2.5concentrations, on top of energy saving and thermal comfort, as achieving those objectives simultaneously can cause multiple control conflicts. What's more, DRL agents are usually trained on the simulation environment before deployment, so another challenge is to develop an accurate but relatively simple simulator. Therefore, we propose a DRL algorithm for a central HVAC system to co-optimize energy consumption, thermal comfort, indoor CO2 level, and indoor PM2.5 level in an office building. To train the controller, we also developed a hybrid simulator that decoupled the complex system into multiple simulation models, which are calibrated separately using laboratory test data. The hybrid simulator combined the dynamics of the HVAC system, the building envelope, as well as moisture, CO2, and particulate matter transfer. Three control algorithms (rule-based, MPC, and DRL) are developed, and their performances are evaluated on the hybrid simulator environment with a realistic scenario (i.e., with stochastic noises). The test results showed that, the DRL controller can save 21.4 % of energy compared to a rule-based controller, and has improved thermal comfort, reduced indoor CO2 concentration. The MPC controller showed an 18.6 % energy saving compared to the DRL controller, mainly due to savings from comfort and indoor air quality boundary violations caused by unmeasured disturbances, and it also highlights computational challenges in real-time control due to non-linear optimization. Finally, we provide the practical considerations for designing and implementing the DRL and MPC controllers based on their respective pros and cons.

Guo, Fangzhou↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

Methods development towards automated, physics-informed, quantitative quality control of TRISO-SiC

Tristructural-isotropic (TRISO) fuel particles have been developed as a high-performance fuel for use in high-temperature gas-cooled reactor (HTGR) systems due to their high efficiency and stability under both normal and off-normal conditions. Broader deployment of this technology in advanced nuclear applications may benefit from quantitative quality assurance and quality control (QA/QC) methods that directly link TRISO properties to downstream performance. A key TRISO property is the SiC layer microstructure, which influences fission product retention during irradiation. However, existing QA/QC for the TRISO-SiC microstructure comprises only a qualitative visual inspection; therefore, there is a clear opportunity for the development of quantitative methods for TRISO QA/QC. Here, to this end, previous work has demonstrated an image processing approach to grain boundary (GB) identification and subsequent extraction of microstructural metrics; however, extensive twinning within the SiC layer complicates such analyses because twin GBs significantly influence microstructural metrics but are not expected to contribute to fission product transport. This study presents the initial development, training, and testing of an ML-based image segmentation algorithm designed to identify and remove twin GBs from standard backscattered electron micrographs, providing an industrially applicable, quantitative, and physically meaningful QA/QC approach for the TRISO-SiC microstructure. Although pixel-wise performance metrics for the twin predictions are low, the change in grain area and the number of GB pixels after twin removal predicted by the ML workflow are within 1% of the true values calculated using crystallographic data. This suggests that the model is well capable of predicting overall twin boundary structures and grain morphology, and continued advancement of this approach could enable automated, scalable, and physics-informed QA/QC for TRISO-SiC microstructures, supporting the reliable qualification of coated particle fuels for next-generation reactor systems.

Computer vision↗

Techno-economic and life-cycle analysis of strategies for improving operability and biomass quality in catalytic fast pyrolysis of forest residues

Many of the challenges faced by the first commercial biorefineries were associated with feedstock handling, quality, and cost. Strategies are needed to enable further expansion of biorefineries and meet the growing demand for bio-based fuels and products. Here, we examine 2 key feedstock challenges and mitigation strategies in the context of a catalytic fast pyrolysis (CFP) biorefinery: (1) the operability of the feed system, which may be improved by modifying the minimum particle size fed to the reactor, and (2) the quality of the biomass, which may be improved by employing air classification to remove undesirable material and increase fuel yields. We conduct techno-economic analysis (TEA) and life-cycle analysis for these strategies, employing a discrete event simulation model for biomass preprocessing combined with a series of correlations developed from literature data and a rigorous CFP conversion model. Our results highlight the importance of balancing increased cost and material losses from preprocessing against improved operability and fuel yields. Economics and sustainability were optimized when operating at the lowest minimum particle size, emphasizing the importance of minimizing material losses while maintaining the operability of the process. Economically, additional costs and material losses from air classification could be acceptable due to improved biomass conversion, and an optimum air classification speed was identified; however, the fuel GHG emissions were minimized when air classification was not used. Valorizing material removed during preprocessing as a coproduct could improve economics and sustainability, decreasing the burden of material losses.

09 - BIOMASS FUELS↗

Integrating Contaminant Source Indicators, Water Quality Measures, and Ecotoxicity to Characterize Contaminant Mixtures and Per- and Polyfluoroalkyl Substance (PFAS) Variability in an Urban Watershed

Thousands of chemical contaminants threaten watersheds but are time and cost prohibitive to monitor. Identifying their sources, transport, and ecological risk is limited in heterogeneous urban watersheds. We present an integrative watershed approach using source-specific indicator compounds, common water quality measures, and ecotoxicity assays to examine the distribution of contaminant mixtures in an urbanized watershed. Indicator compound concentrations were temporally and spatially distributed for treated/untreated sewage (sucralose, artificial sweetener), road runoff (diphenyl-guanidine [DPG] and 6PPD-quinone [6PPD-Q], automobile tire additives), and lawncare runoff (aminomethanephosphonic acid (AMPA), major degradant of the herbicide glyphosate). Sucralose was predominately sourced from treated wastewater; measurable concentrations in tributaries indicated raw sewage inputs. DPG and 6PPD-Q concentrations correlated to road density during base flow and were elevated during stormflow. AMPA was measurable spring through fall, especially where lawns were dense. When specific sources dominated flow, water quality measures correlated with wastewater (sulfate, potassium, chloride, and sodium) and road runoff (chromium and lead) indicators. The limited behavioral toxicity observed in exposed zebrafish (Danio rerio) (18%) was not well explained by source-indicators. PFAS concentrations were highly variable spatially but not well explained by our source-specific indicator compounds. Here, more costly compound-specific monitoring may be necessary when multiple sources exist or when unexpected toxicity trends occur.

computer simulations↗