Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality assurance framework”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

SU-F-T-156: Monte Carlo Simulation Using TOPAS for Synchrotron Based Proton Discrete Spot Scanning System

Purpose: This study provides an overview of the design and commissioning of the Monte Carlo (MC) model of the spot-scanning proton therapy nozzle and its implementation for the patient plan simulation. Methods: The Hitachi PROBEAT V scanning nozzle was simulated based on vendor specifications using the TOPAS extension of Geant4 code. FLUKA MC simulation was also utilized to provide supporting data for the main simulation. Validation of the MC model was performed using vendor provided data and measurements collected during acceptance/commissioning of the proton therapy machine. Actual patient plans using CT based treatment geometry were simulated and compared to the dose distributions produced by the treatment planning system (Varian Eclipse 13.6), and patient quality assurance measurements. In-house MATLAB scripts are used for converting DICOM data into TOPAS input files. Results: Comparison analysis of integrated depth doses (IDDs), therapeutic ranges (R90), and spot shape/sizes at different distances from the isocenter, indicate good agreement between MC and measurements. R90 agreement is within 0.15 mm across all energy tunes. IDDs and spot shapes/sizes differences are within statistical error of simulation (less than 1.5%). The MC simulated data, validated with physical measurements, were used for the commissioning of the treatment planning system. Patient geometry simulations were conducted based on the Eclipse produced DICOM plans. Conclusion: The treatment nozzle and standard option beam model were implemented in the TOPAS framework to simulate a highly conformal discrete spot-scanning proton beam system.

60 APPLIED LIFE SCIENCES↗

Developing Multiphysics, Integrated, High-Fidelity, Massively Parallel Computational Capabilities for Fusion Applications Using MOOSE

As the need for fusion as a clean, sustainable, and abundant energy source grows internationally, so does the need for multiphysics, computational tools to model, study, and predict the complex interactions between plasma, materials, and engineering processes. These tools have a crucial role to play in solving scientific and engineering challenges and accelerating fusion energy deployment. To address these needs, modeling capabilities should enable massively parallel, multiphysics, fully integrated high-fidelity simulations of fusion systems. Additional attributes, such as being open source and modular while maintaining high software quality assurance standards will maximize impact by ensuring accessibility for all and wide acceptance, rapid expansion and development, as well as reliability, efficiency, and robustness. In this paper, we describe how the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, which has a track record of success in the fission space thanks to the attributes listed above, can be leveraged in the fusion energy field. We highlight key successes of the MOOSE application in the fission space and describe how MOOSE has been and is being applied to fusion applications in the United States---e.g., Tritium Migration Analysis Program, version 8 (TMAP8), MOOSE Fusion Module, Fusion ENergy Integrated multiphys-X (FENIX)---and the United Kingdom---e.g., AURORA, Achlys, Apollo. These efforts aim to establish a suite of tools that can be further extended to accelerate fusion energy deployment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Griffin: A Moose-based Reactor Multiphysics Application For Radiation Transport And Depletion Simulations

Griffin is a MOOSE-based reactor multiphysics application that streamlines the analysis of a variety of nuclear multiphysics applications, including steady-state and transient radiation transport, core performance, fuel depletion, criticality and decay heat calculations, reprocessing and post-irradiation examination. This streamlining is accomplished via enhanced flexibility of the tools, uniform syntax in the MOOSE framework, dynamic linking of all relevant physics and a single point of execution. The design for flexible multi-physics, multi-radiation, multi-scheme tasks demands and ultimately makes Griffin a highly extendable code system. A software quality assurance (SQA) procedure is enforced during Griffin development.

DeHart, MarkD.↗

NRAP-Open-IAM Multisegmented Wellbore Reduced-Order Model

Geologic carbon storage is one of the promising strategies to mitigate climate change by reducing the emission of carbon dioxide to the atmosphere. As part of the National Risk Assessment Partnership (NRAP), a systems-level stochastic analysis tool called the open source integrated assessment model, NRAP-Open-IAM, has been developed to estimate and manage the risk of containment loss at a geological carbon sequestration site. NRAP-Open-IAM contains several wellbore leakage model components that estimate the fluid leak rate that may occur through compromised legacy wells due to the increase in pressure resulting from CO 2 injection activities. Coupled to a reservoir component model, these components estimate the leakage of CO 2 and/or brine from a storage reservoir to overlying aquifer layers and the atmosphere through legacy wells. This report presents the theoretical framework and quality testing of the multisegmented wellbore reduced-order model. The model allows for segmenting of the legacy wells passing through the overlying stratigraphy into several intervals to simulate a site’s specific stratigraphic and hydrogeologic properties. For quality assurance, the analytical model is validated against numerical reservoir flow simulations for single and multiple aquifer(s) models. The results indicate that the model accurately predicts the transport of two-phase fluids (brine and injected CO 2 ) through the well over time. A detailed description of the model helps users to understand the model and provides a basis for future improvements.

58 GEOSCIENCES↗

The Gene Ontology Resource: 20 years and still GOing strong

The Gene Ontology resource (GO; http://geneontology.org) provides structured, computable knowledge regarding the functions of genes and gene products. Founded in 1998, GO has become widely adopted in the life sciences, and its contents are under continual improvement, both in quantity and in quality. Here, we report the major developments of the GO resource during the past two years. Each monthly release of the GO resource is now packaged and given a unique identifier (DOI), enabling GO-based analyses on a specific release to be reproduced in the future. The molecular function ontology has been refactored to better represent the overall activities of gene products, with a focus on transcription regulator activities. Quality assurance efforts have been ramped up to address potentially out-of-date or inaccurate annotations. New evidence codes for high-throughput experiments now enable users to filter out annotations obtained from these sources. GO-CAM, a new framework for representing gene function that is more expressive than standard GO annotations, has been released, and users can now explore the growing repository of these models. We also provide the 'GO ribbon' widget for visualizing GO annotations to a gene; the widget can be easily embedded in any web page.

59 BASIC BIOLOGICAL SCIENCES↗

Griffin-m

Griffin-m is a MOOSE-based reactor multiphysics application that streamlines the analysis of a variety of nuclear multiphysics simulations, including steady-state and transient radiation transport, core performance, fuel depletion, criticality and decay heat calculations, reprocessing and post-irradiation examination. This streamlining is accomplished via enhanced flexibility of the tools, uniform syntax in the MOOSE framework, dynamic linking of all relevant physics and a single point of execution. The design for flexible multi-physics, multi-radiation, multi-scheme tasks demands and ultimately makes Griffin-m a highly extendable code system. A software quality assurance (SQA) procedure is enforced during Griffin-m development. The Griffin-m version will be the main production version and it includes the MCC3 code, which was originally developed at Argonne National Laboratory to prepare cross sections for fast reactors.

Ortensi, Javier [Idaho National Laboratory (INL), ↗

Minimizing treatment planning errors in proton therapy using failure mode and effects analysis

Purpose: Failure mode and effects analysis (FMEA) is a widely used tool to evaluate safety or reliability in conventional photon radiation therapy. However, reports about FMEA application in proton therapy are scarce. The purpose of this study is to apply FMEA in safety improvement of proton treatment planning at their center. Methods: The authors performed an FMEA analysis of their proton therapy treatment planning process using uniform scanning proton beams. The authors identified possible failure modes in various planning processes, including image fusion, contouring, beam arrangement, dose calculation, plan export, documents, billing, and so on. For each error, the authors estimated the frequency of occurrence, the likelihood of being undetected, and the severity of the error if it went undetected and calculated the risk priority number (RPN). The FMEA results were used to design their quality management program. In addition, the authors created a database to track the identified dosimetric errors. Periodically, the authors reevaluated the risk of errors by reviewing the internal error database and improved their quality assurance program as needed. Results: In total, the authors identified over 36 possible treatment planning related failure modes and estimated the associated occurrence, detectability, and severity to calculate the overall risk priority number. Based on the FMEA, the authors implemented various safety improvement procedures into their practice, such as education, peer review, and automatic check tools. The ongoing error tracking database provided realistic data on the frequency of occurrence with which to reevaluate the RPNs for various failure modes. Conclusions: The FMEA technique provides a systematic method for identifying and evaluating potential errors in proton treatment planning before they result in an error in patient dose delivery. The application of FMEA framework and the implementation of an ongoing error tracking system at their clinic have proven to be useful in error reduction in proton treatment planning, thus improving the effectiveness and safety of proton therapy.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 02: Recent work on TQC Suite and Data from a National survey on Community Uptake

The Canadian Partnership for Quality Radiotherapy (CPQR) and the Canadian Organization of Medical Physicist’s (COMP) Quality Assurance and Radiation Safety Advisory Committee (QARSAC) have worked together in the development of a suite of Technical Quality Control (TQC) Guidelines for radiation treatment equipment and technologies, that outline specific performance objectives and criteria that equipment should meet in order to assure an acceptable level of radiation treatment quality. Early community engagement and uptake survey data showed 70% of Canadian centers are part of this process and that the data in the guideline documents reflect, and are influencing the way Canadian radiation treatment centres run their technical quality control programs. As the TQC development framework matured as a cross-country initiative, guidance documents have been developed in many clinical technologies. Recently, there have been new TQC documents initiated for Gamma Knife and Cyberknife technologies where the entire communities within Canada are involved in the review process. At the same time, QARSAC reviewed the suite as a whole for the first time and it was found that some tests and tolerances overlapped across multiple documents as single tests could pertain to multiple quality control areas. The work to streamline the entire suite has allowed for improved usability of the suite while keeping the integrity of single quality control areas. The suite will be published by the JACMP, in the coming year.

60 APPLIED LIFE SCIENCES↗

Best practice reporting guideline for building stock energy models

Buildings are responsible for 38% of global greenhouse gas (GHG) emissions and, therefore, pathways to reduce their impact are crucial to achieve climate targets. Building stock energy models (BSEMs) have long been used as a tool to assess the current and future energy demand and environmental impact of building stocks. BSEMs have become more and more complex and are often tailored to case-specific datasets, which results in a high degree of heterogeneity among models. This heterogeneity, together with a lack of consistency in the reporting hinders the understanding of these models and, thereby, an accurate interpretation and comparison of results. In this paper we present a reporting guideline in order to improve reporting practices of BSEMs. The guideline was developed by experts as part of the IEA's Annex 70 and builds upon reporting guidelines from other fields. It consists of five topics (Overview, Model Components, Input and Output, Quality Assurance and Additional Information), which are further subdivided into subtopics. We explain which model aspects should be described in each subtopic, and provide illustrative examples on how to apply the guideline. In closing, the reporting guideline is consistent with the model classification framework and online model registry also developed in the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Optimization-Based Framework to Define the Probabilistic Design Space of Pharmaceutical Processes with Model Uncertainty

To increase manufacturing flexibility and system understanding in pharmaceutical development, the FDA launched the quality by design (QbD) initiative. Within QbD, the design space is the multidimensional region (of the input variables and process parameters) where product quality is assured. Given the high cost of extensive experimentation, there is a need for computational methods to estimate the probabilistic design space that considers interactions between critical process parameters and critical quality attributes, as well as model uncertainty. In this paper we propose two algorithms that extend the flexibility test and flexibility index formulations to replace simulation-based analysis and identify the probabilistic design space more efficiently. The effectiveness and computational efficiency of these approaches is shown on a small example and an industrial case study.

60 APPLIED LIFE SCIENCES↗

Groundwater Monitoring Report, U.S. Department of Energy Y-12 National Security Complex, Oak Ridge, Tennessee

This report contains the groundwater and surface water monitoring data obtained during calendar year (CY) 2019 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) on the DOE Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee. The monitoring data were obtained from wells, springs, and surface water sampling locations in three hydrogeologic regimes at Y-12. The Bear Creek Hydrogeologic Regime (Bear Creek Regime) encompasses a section of Bear Creek Valley (BCV) between the west end of Y-12 and the west end of the Bear Creek Watershed (directions are in reference to the Y-12 grid system, shown as Plant North. The Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime) encompasses the Y-12 industrial facilities and support structures in BCV. The Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime) encompasses a section of Chestnut Ridge directly south of Y-12. Background information in Section 2 of this report outlines the hydrogeologic framework for groundwater and surface water quality monitoring at Y-12 and includes an overview of the groundwater contamination in each hydrogeologic regime. Section 3 provides details regarding the groundwater and surface water sampling and analysis activities implemented under the Y-12 GWPP, including sampling locations and frequency, sample collection and handling, field measurements and laboratory analytes, quality assurance (QA)/quality control (QC) sampling, data management, and data quality assessment (DQA). However, the equivalent QA/QC or DQA information for the groundwater and surface water data associated with the monitoring programs implemented by UCOR are not included in this report and instead are deferred to referenced programmatic plans and reports issued by OREM and UCOR. Section 4 of this report presents a summary evaluation of the CY 2019 monitoring data with regard to the respective objectives of surveillance monitoring and exit pathway/perimeter monitoring. The evaluation is based primarily on the analytical results for the following principal groundwater contaminants at Y-12: nitrate, uranium, gross alpha activity, gross beta activity, and volatile organic compounds (VOCs). Section 5 summarizes the most significant findings with respect to the principal contaminants along with recommendations for any proposed changes to the ongoing groundwater and surface water quality monitoring performed under the Y-12 GWPP. Technical reports and plans cited in the narrative sections of the report are listed in Section 6. Narrative sections of this report reference several appendices. Figures (maps and diagrams) and data tables (excluding data summary tables incorporated in the narrative sections) are in Appendix A and Appendix B, respectively. Appendix C contains construction details for each well sampled during CY 2019 by either the Y-12 GWPP or UCOR, along with schematic diagrams for wells equipped with Westbay™ multiport sampling equipment or Barcad® pump systems. Appendix D supports the background summary discussion in Section 2 and provides more detailed information about the hydrogeologic framework for groundwater and surface water monitoring at Y-12, including the primary sources of groundwater contamination in each hydrogeologic regime. Results for all field measurements and laboratory analyses obtained by the Y-12 GWPP and UCOR are presented in Appendix E, which also includes the sample numbers for the QA/QC samples associated with groundwater and surface water monitoring performed by the Y-12 GWPP.

54 ENVIRONMENTAL SCIENCES↗

NASA software documentation standard software engineering program

The NASA Software Documentation Standard (hereinafter referred to as Standard) can be applied to the documentation of all NASA software. This Standard is limited to documentation format and content requirements. It does not mandate specific management, engineering, or assurance standards or techniques. This Standard defines the format and content of documentation for software acquisition, development, and sustaining engineering. Format requirements address where information shall be recorded and content requirements address what information shall be recorded. This Standard provides a framework to allow consistency of documentation across NASA and visibility into the completeness of project documentation. This basic framework consists of four major sections (or volumes). The Management Plan contains all planning and business aspects of a software project, including engineering and assurance planning. The Product Specification contains all technical engineering information, including software requirements and design. The Assurance and Test Procedures contains all technical assurance information, including Test, Quality Assurance (QA), and Verification and Validation (V&V). The Management, Engineering, and Assurance Reports is the library and/or listing of all project reports.

Source record↗

NASA Software Documentation Standard

The NASA Software Documentation Standard (hereinafter referred to as "Standard") is designed to support the documentation of all software developed for NASA; its goal is to provide a framework and model for recording the essential information needed throughout the development life cycle and maintenance of a software system. The NASA Software Documentation Standard can be applied to the documentation of all NASA software. The Standard is limited to documentation format and content requirements. It does not mandate specific management, engineering, or assurance standards or techniques. This Standard defines the format and content of documentation for software acquisition, development, and sustaining engineering. Format requirements address where information shall be recorded and content requirements address what information shall be recorded. This Standard provides a framework to allow consistency of documentation across NASA and visibility into the completeness of project documentation. The basic framework consists of four major sections (or volumes). The Management Plan contains all planning and business aspects of a software project, including engineering and assurance planning. The Product Specification contains all technical engineering information, including software requirements and design. The Assurance and Test Procedures contains all technical assurance information, including Test, Quality Assurance (QA), and Verification and Validation (V&V). The Management, Engineering, and Assurance Reports is the library and/or listing of all project reports.

Source record↗

A Dynamic Waste Isolation Pilot Plant Performance Assessment Tool - 12490

The Waste Isolation Pilot Plant (WIPP) Performance Assessment (PA) methodology comprises a toolbox used to demonstrate regulatory compliance of the repository after facility closure. The PA framework rests upon an extensive suite of computational codes. In some cases, significant alteration of code inputs is a tedious and difficult task. Due to the nature of the application for which they are used, PA codes used in support of WIPP regulatory compliance demonstration must satisfy stringent quality assurance requirements. Consequently, many of the coding practices used during original code development are still implemented today. A more efficient workflow configuration has the potential to alleviate difficulties associated with extensive code input modifications. Here, this potential is assessed via an implementation of a more flexible scientific workflow system for a subset of the codes used in WIPP PA. The scientific workflow approach taken here for a dynamic PA system enables users from disparate backgrounds to dramatically shorten the time between hypothesis and analysis by decreasing the amount of a priori knowledge, from a range of disciplines, needed to execute the code. Having smaller iteration times allows for more ideas to be tested and explored, which leads to safer and more optimized systems. Note that these high-level, dynamic tools are intended only for initial scoping studies on the personal computer of a researcher. Full, regulatory compliance calculations may occur only within a qualified computing environment. However, the WIPP PA tools here may guide future research and indicate regions of the analysis space that are worth further study. This next generation of PA software provides the ability to perform scoping investigations of repository performance quickly and easily, and has an accessible and useful interface to a variety of users, such as fuel cycle systems designers, domain experts such as repository modelers, and policy makers. The purview of this project allows for many opportunities for future work. Foremost among these is the desire to implement the full BRAGFLO suite within the workflow. This will entail porting or wrapping Genmesh, Matset, LHS, and ICSet within Python. Moreover, unifying the two GUIs into a single driver application would be a natural next step. Once the BRAGFLO suite is completed, other portions of WIPP PA could be implemented with corresponding and inter-operable work-flows. Likely first candidates for this are those codes that are similarly computationally intensive, such as the one used to generate complementary cumulative distribution functions used to demonstrate regulatory compliance (code CCDFGF). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methodology Guidelines on Life Cycle Assessment of Photovoltaic 2020, 4th Edition

Life Cycle Assessment (LCA) is a structured, comprehensive method of quantifying material- and energy-flows and their associated emissions caused in the life cycle 1 of goods and services. The ISO 14040 and 14044 standards provide the framework for LCA. However, this framework leaves the individual practitioner with a range of choices that can affect the results and thus the conclusions of an LCA study. The present version of the IEA LCA guidelines is the result of the third update. They were developed and are updated to provide guidance on assuring consistency, balance, and quality to enhance the credibility and reliability of the results from LCAs on photovoltaic (PV) electricity generation systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WE-D-16A-01: ACR Radiology Leadership Institute

The Radiology Leadership Institute (RLI) was established in 2011 by the American College of Radiology with a mission to prepare leaders who will shape the future of radiology to ensure quality, elevate service and deliver extraordinary patient care. Leadership skills are critical to medical physicists in order for them to assure that imaging and therapy are safe and of the highest quality possible. This session will provide an introduction to the RLI and its programs with an emphasis on how medical physicists can get involved and what they might expect to gain through their engagement with the RLI. The session will also provide a framework for leadership in healthcare with an emphasis on roles and opportunities for medical physicists to enhance their effectiveness as members of the healthcare, medical education, and research communities.

60 APPLIED LIFE SCIENCES↗

SU-E-T-163: Characterization of a Novel High Resolution 1D Silicon Monolithic Array for Small Field Commissioning and Quality Assurance

Purpose: To study the suitability of a novel 1D silicon monolithic array for dosimetry of small radiation fields and for QA of high dose gradient treatment modalities (IMRT and SBRT). Methods: A 1D array composed of 4 monolithic silicon modules of 64 mm length and 1 mm pixel pitch was developed by IBA Dosimetry. Measurements were carried out for 6MV and 15MV photons on two commercial different linacs (TrueBeam and Clinac iX, Varian Medical Systems, Palo Alto, CA) and for a CyberKnife G4 (Accuray Inc., Sunnyvale, CA). The 1D array was used to measure output factors (OF), profiles and off axis correction factors (OACF) for the Iris CyberKnife variable collimator (5–60 mm). In addition, dose profiles (at the isocenter plane) were measured for multiple IMRT and SBRT treatment plans and compared with those obtained using EDR2radiographic film (Carestream Health, Rochester NY), a commercial 2D diode array and with the dose distribution calculated using a commercial TPS (Eclipse, Varian Medical Systems, Palo Alto, CA). Results: Due to the small pixel pitch of the detector, IMRT and SBRT plan profiles deviate from film measurements by less than 2%. Similarly, the 1D array exhibits better performance than the 2D diode array due to the larger (7 mm) pitch of that device. Iris collimator OFs measured using the 1D silicon array are in good agreement with the commissioning values obtained using a commercial stereotactic diode as well as with published data. Maximum deviations are < 3% for the smallest field (5 and 7.5mm) and below 1% for all other dimensions. Conclusion: We have demonstrated good performances of the array for commissioning of small photon fields and in patient QA, compared with diodes and film typically used in these clinical applications. The technology compares favorably with existing commercial solutions The presenting author is founded by a Marie Curie Early Initial Training Network Fellowship of the European Communitys Seventh Framework Programme under contract number (PITN-GA-2011-289198-ARDENT). The research activity is hosted by IBA Dosimetry, Gmbh.

60 APPLIED LIFE SCIENCES↗

Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗