Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantitative imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Phase I Final Technical Report: High-Resolution Gamma-ray Imaging and Spectroscopy for Special Nuclear Material Assay (GeGI-DNN)

The Phase I program focused on the development, implementation, and evaluation of spectral and spatial algorithms to improve the intrinsic image quality and efficiency of GeGI-DNN for count-starved (low activity) measurement scenarios. As a direct result of the Phase-I achievements, Pinhole imaging efficiency was dramatically improved, Compton imaging performance was improved by incorporating a statistical treatment of the Compton image, and quantitative image analysis routines were developed and implemented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fusing Quantitative-Phase Imaging with Airy Light- Sheet Microscopy

We report the integration of quantitative-phase imaging (QPI) with light-sheet (LS) fluorescent microscopy on to a standard inverted microscope that retains compatibility with microfluidics. QPI enables label-free imaging and number-density quantification of single cells and their organelles. Conversely, LS yields considerable speed and phototoxicity gains in quantifying the 4D dynamics of gene-encoded fluorescent biomarkers. We will detail the system design that relied on spatial light interferometry for QPI and an accelerating Airy- beam light-sheet for fluorescence, its performance, as well as results of a representative multivariate imaging analysis of single-cell metabolism.

imaging, lattice light sheet, Yarrowia lipolytica,↗

Electroluminescence Imaging: A Quantitative Characterization Technique to Measure Dust Occlusion of Solar Cells

Electroluminescence (EL) imaging is a qualitative characterization technique that is typically used to identify cracks, corrosion, and other defects in solar cells. It consists of imaging a cell under forward bias, where the solar cell emits photons due to radiative electron-hole pair recombination. Over the past few years, our team has expanded this into a quantitative technique with the help of image processing. We have primarily used this method to investigate lunar dust occlusion of solar cells and arrays. Lunar dust accumulation on solar cells is a major concern because it directly limits light accessible to the cell, decreasing power output. Many teams are working to develop dust mitigation technology to protect these arrays on the surface of the Moon, but thoroughly characterizing their efficacy is important to ensure their success prior to launch. Here, we present EL as a quantitative characterization technique to observe dust coverage on solar cells that, when coupled with IV performance measurements, can offer unique insights into how dust coverage impacts power output. Quantitative electroluminescence imaging works by running EL images through an image processing script that first grayscales the image then plots a histogram of the brightness of each pixel. On its own, it does not offer much insight into a solar cell’s performance. However, when comparing images to a baseline pristine, undamaged, or uncoated solar cell, it can quickly provide information about the impacts of surface contaminants or damage to the cell. Here, we present a case study where quantitative EL is used to measure the efficacy of dust mitigation technology for flexible solar arrays and discuss the lessons learned about dust mitigation, testing with lunar simulant, and this characterization technique.

photovoltaics↗

Surrogate Distributed Radiological Sources—Part III: Quantitative Distributed Source Reconstructions

In this third part of a multi-paper series, we present quantitative image reconstruction results from aerial measurements of eight different surrogate distributed gamma-ray sources on flat terrain. Here, we show that our quantitative imaging methods can accurately reconstruct the expected shapes, and, after appropriate calibration, the absolute activity of the distributed sources. We conduct several studies of imaging performance versus various measurement and reconstruction parameters, including detector altitude and raster pass spacing, data and modeling fidelity, and regularization type and strength. The imaging quality performance is quantified using various quantitative image quality metrics. Our results confirm the utility of point source arrays as surrogates for truly distributed radiological sources, and advance the quantitative capabilities of Scene Data Fusion gamma-ray imaging methods.

Airborne survey↗

Global Auroral Energy Deposition Derived from Polar UVI Images

Quantitative measurement of the transfer of energy and momentum to the ionosphere from the solar wind is one of the main objectives of the ISTP program. Global measurement of auroral energy deposition derived from observations of the longer wavelength LBH band emissions made by the Ultraviolet Imager on the Polar spacecraft is one of the key elements in this satellite and ground-based instrument campaign. These "measurements" are inferred by combining information from consecutive images using different filters and have a time resolution on the average of three minutes and are made continuously over a 5 to 8 hour period during each 18 hour orbit of the Polar spacecraft. The energy deposition in the ionosphere from auroral electron precipitation augments are due to Joule heating associated with field aligned currents. Assuming conjugacy of energy deposition between the two hemispheres the total energy input to the ionosphere through electron precipitation can be determined at high time resolution. Previously, precipitating particle measurements along the tracks of low altitude satellites provided only local measurements and the global energy precipitation could be inferred through models but not directly measured. We use the UVI images for the entire month of January 1997 to estimate the global energy deposition at high time resolution. We also sort the energy deposition into sectors to find possible trends, for example, on the dayside and nightside, or the dawn and dusk sides.

Fillingim, M. O.↗

Reconstruction and analysis of exploding wire particle trajectories via automatic calibration of stereo images

Quantitative understanding of the physics of dust or granular matter transport significantly impacts several aspects of burning plasma science and technology. Here, this work takes machine vision techniques popular in robotics and self-driving cars and applies them to identification and analysis of microparticles generated from exploding wires. Using only the image frames and knowledge of the intrinsic properties of the cameras, a Python code was written to identify the particles, automatically calibrate the relative image positions, and extract trajectory data. After identifying approximately 50 particles based on the timing of secondary particle explosions, the eight point and random sample consensus algorithms were used to determine the geometric correlation between the cameras. Over 100 particle matches were found between the two camera views. These correlated trajectories were used in subsequent 3D track reconstruction and analysis of the physics behind the particle motion. The 3D reconstruction resulted in accurate positioning of the particles with respect to the experimental setup. The particle motion was consistent with the effects of a 1 g gravitational field modified by drag forces. Lastly, the methods and analyses presented here can be used in many facets of high temperature plasma diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of Black Body Grids by Thick Film Printing for Quantitative Neutron Imaging

Neutron imaging offers deep penetration through many high-Z materials while also having high sensitivity to certain low-Z isotopes such as 1H, 6Li, and 10B. This unique combination of properties has made neutron imaging an attractive tool for a wide range of material science and engineering applications. However, measurements made by neutron imaging or tomography are generally qualitative in nature due to the inability of detectors to discriminate between neutrons which have been transmitted through the sample and neutrons which are scattered by the sample or within the detector. Recent works have demonstrated that deploying a grid of small black bodies (BBs) in front of the sample can allow for the scattered neutrons to be measured at the BB locations and subsequently subtracted from the total measured intensity to yield a quantitative transmission measurement. While this method can be very effective, factors such as the scale and composition of the sample, the beam divergence, and the resolution and construction of the detector may require optimization of the grid design to remove all measurement biases within a given experimental setup. Therefore, it is desirable to have a method by which BB grids may be rapidly and inexpensively produced such that they can easily be tailored to specific applications. In this work, we present a method for fabricating BB patterns by thick film printing of Gd2O3 and evaluate the performance with variation in feature size and number of print layers with cold and thermal neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffraction enhance x-ray imaging for quantitative phase contrast studies

Conventional X-ray imaging based on absorption contrast permits limited visibility of feature having small density and thickness variations. For imaging of weakly absorbing material or materials possessing similar densities, a novel phase contrast imaging techniques called diffraction enhanced imaging has been designed and developed at imaging beamline Indus-2 RRCAT Indore. The technique provides improved visibility of the interfaces and show high contrast in the image forsmall density or thickness gradients in the bulk. This paper presents basic principle, instrumentation and analysis methods for this technique. Initial results of quantitative phase retrieval carried out on various samples have also been presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrative Quantitative-Phase and Airy Light-Sheet Imaging

Light-sheet microscopy enables considerable speed and phototoxicity gains, while quantitative-phase imaging confers label-free organelle recognition and metabolic information that are inaccessible by conventional methods. We report the fusion of these two modalities onto a standard inverted microscope that retains compatibility with microfluidics. We describe the utilization of an accelerating Airy-beam light-sheet yielding identical imaging areas with interferometry, and an application in unmasking the effects of cellular noise on metabolic compartmentalization.

Biological sciences, Biological techniques, Micros↗

Comprehensive single-shot biophysical cytometry using simultaneous quantitative phase imaging and Brillouin spectroscopy

Abstract Single-cell analysis, or cytometry, is a ubiquitous tool in the biomedical sciences. Whereas most cytometers use fluorescent probes to ascertain the presence or absence of targeted molecules, biophysical parameters such as the cell density, refractive index, and viscosity are difficult to obtain. In this work, we combine two complementary techniques—quantitative phase imaging and Brillouin spectroscopy—into a label-free image cytometry platform capable of measuring more than a dozen biophysical properties of individual cells simultaneously. Using a geometric simplification linked to freshly plated cells, we can acquire the cellular diameter, volume, refractive index, mass density, non-aqueous mass, fluid volume, dry volume, the fractional water content of cells, both by mass and by volume, the Brillouin shift, Brillouin linewidth, longitudinal modulus, longitudinal viscosity, the loss modulus, and the loss tangent, all from a single acquisition, and with no assumptions of underlying parameters. Our methods are validated across three cell populations, including a control population of CHO-K1 cells, cells exposed to tubulin-disrupting nocodazole, and cells under hypoosmotic shock. Our system will unlock new avenues of research in biophysics, cell biology, and medicine.

Steelman, Zachary A.↗

Quantitative Ultrasonic Nakagami Imaging of Neck Fibrosis After Head and Neck Radiation Therapy

Purpose: To investigate the feasibility of ultrasound Nakagami imaging to quantitatively assess radiation-induced neck fibrosis, a common sequela of radiation therapy (RT) to the head and neck. Methods and Materials: In a pilot study, 40 study participants were enrolled and classified into 3 subgroups: (1) a control group of 12 healthy volunteers; (2) an asymptomatic group of 11 patients who had received intensity modulated RT for head and neck cancer and had experienced no neck fibrosis; and (3) a symptomatic group of 17 post-RT patients with neck fibrosis. Each study participant underwent 1 ultrasound study in which scans were performed in the longitudinal orientation of the bilateral neck. Three Nakagami parameters were calculated to quantify radiation-induced tissue injury: Nakagami probability distribution function, shape, and scaling parameters. Physician-based assessments of the neck fibrosis were performed according to the Radiation Therapy Oncology Group late morbidity scoring scheme, and patient-based fibrosis assessments were rated based on symptoms such as pain and stiffness. Results: Major discrepancies existed between physician-based and patient-based assessments of radiation-induced fibrosis. Significant differences in all Nakagami parameters were observed between the control group and 2 post-RT groups. Moreover, significant differences in Nakagami shape and scaling parameters were observed among asymptomatic and symptomatic groups. Compared with the control group, the average Nakagami shape parameter value increased by 32.1% (P<.001), and the average Nakagami scaling parameter increased by 55.7% (P<.001) for the asymptomatic group, whereas the Nakagami shape parameter increased by 74.1% (P<.001) and the Nakagami scaling parameter increased by 83.5% (P<.001) for the symptomatic group. Conclusions: Ultrasonic Nakagami imaging is a potential quantitative tool to characterize radiation-induced asymptomatic and symptomatic neck fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Infrared Image Analysis Of Simultaneous Upstream and Downstream Microgravity Flame Spread over Thermally-Thin Cellulose in Low Speed Forced Flow

The effect of low velocity forced flow on microgravity flame spread is examined using quantitative analysis of infrared video imaging. The objective of the quantitative analysis is to provide insight into the mechanisms of flame spread in microgravity where the flame is able to spread from a central location on the fuel surface, rather than from an edge. Surface view calibrated infrared images of ignition and flame spread over a thin cellulose fuel were obtained along with a color video of the surface view and color images of the edge view using 35 mm color film at 2 Hz. The cellulose fuel samples were mounted in the center of a 12 cm wide by 16 cm tall flow duct and were ignited in microgravity using a straight hot wire across the center of the 7.5 cm wide by 14 cm long samples. Four cases, at 1 atm. 35%O2 in N2, at forced flows from 2 cm/s to 20 cm/s are presented here. This flow range captures flame spread from strictly upstream spread at low flows, to predominantly downstream spread at high flow. Surface temperature profiles are evaluated as a function of time, and temperature gradients for upstream and downstream flame spread are measured. Flame spread rates from IR image data are compared to visible image spread rate data. IR blackbody temperatures are compared to surface thermocouple readings to evaluate the effective emissivity of the pyrolyzing surface. Preheat lengths and pyrolysis lengths are evaluated both upstream and downstream of the central ignition point. A surface energy balance estimates the net heat flux from the flame to the fuel surface along the length of the fuel. Surface radiative loss and gas-phase radiation from soot are measured relative to the net heat feedback from the flame. At high surface heat loss relative to heat feedback, the downstream flame spread does not occur.

Olson, S. L.↗

Eliciting the impacts of cellular noise on metabolic trade-offs by quantitative mass imaging

Metabolic trade-offs between growth and productivity are key constraints in metabolic engineering and adaptive evolution; however, how cellular noise impacts these trade offs and drives the emergence of subpopulations with distinct resource allocation strategies, remains largely unknown. Here, we introduce a single-cell strategy for quantifying the trade-offs between triacylglycerol production and growth in the oleaginous microorganism Yarrowia lipolytica. The strategy relies on high-throughput quantitative-phase imaging and, enabled by nanoscale secondary ion mass spectrometry analyses and dedicated image processing, allows us to image how resources are partitioned between growth and productivity. Enhanced precision over population-averaging biotechnologies and conventional microscopy demonstrates how cellular noise impacts growth and productivity differently. As such, subpopulations with distinct metabolic trade-offs emerge, with notable impacts on strain performance and robustness. By quantifying autophagic catabolic fluxes under nutrient-limiting conditions, we discover an underlying cell-to-cell heterogeneity in protein and fatty-acid recycling, unmasking a potential bet-hedging survival strategy under starvation.

59 BASIC BIOLOGICAL SCIENCES↗

Quantitative PLIF Imaging in High-Pressure Combustion

This is the final report for a research project aimed at developing planar laser-induced fluorescence (PLIF) techniques for quantitative 2-D species imaging in fuel-lean, high-pressure combustion gases, relevant to modem aircraft gas turbine combustors. The program involved both theory and experiment. The theoretical activity led to spectroscopic models that allow calculation of the laser-induced fluorescence produced in OH, NO and 02 for arbitrary excitation wavelength, pressure, temperature, gas mixture and laser linewidth. These spectroscopic models incorporate new information on line- broadening, energy transfer and electronic quench rates. Extensive calculations have been made with these models in order to identify optimum excitation strategies, particularly for detecting low levels (ppm) of NO in the presence of large 02 mole fractions (10% is typical for the fuel-lean combustion of interest). A promising new measurement concept has emerged from these calculations, namely that excitation at specific wavelengths, together with detection of fluorescence in multiple spectral bands, promises to enable simultaneous detection of both NO (at ppm levels) and 02 or possibly NO, 02 and temperature. Calculations have been made to evaluate the expected performance of such a diagnostic for a variety of conditions and choices of excitation and detection wavelengths. The experimental effort began with assembly of a new high-pressure combustor to provide controlled high-temperature and high-pressure combustion products. The non-premixed burner enables access to postflame gases at high temperatures (to 2000 K) and high pressures (to 13 atm), and a range of fuel-air equivalence ratios. The chamber also allowed use of a sampling probe, for chemiluminescent detection of NO/NO2, and thermocouples for measurement of gas temperature. Experiments were conducted to confirm the spectroscopic models for OH, NO and 02.

Hanson, R. K.↗

SU-F-J-08: Quantitative SPECT Imaging of Ra-223 in a Phantom

Purpose: Ra-223 therapy of prostate cancer bone metastases is being used to treat patients routinely. However, the absorbed dose distribution at the macroscopic and microscopic scales remains elusive, due to the inability to image the small activities injected. Accurate activity quantification through imaging is essential to calculate the absorbed dose in organs and sub-units in radiopharmaceutical therapy, enabling personalized absorbed dose-based treatment planning methodologies and more effective and optimal treatments. Methods: A 22 cm diameter by 20 cm long cylindrical phantom, containing a 3.52 cm diameter sphere, was used. A total of 2.01 MBq of Ra-223 was placed in the phantom with 177.6 kBq in the sphere. Images were acquired on a dual-head Siemens Symbia T16 gamma camera using three 20% full-width energy windows and centered at 84, 154, and 269 keV (120 projections, 360° rotation, 45 s per view). We have implemented reconstruction of Ra-223 SPECT projections using OS-EM (up to 20 iterations of 10 subsets) with compensation for attenuation using CT-based attenuation maps, collimator-detector response (CDR) (including septal penetration, scatter and Pb x-ray modeling), and scatter in the patient using the effective source scatter estimation (ESSE) method. The CDR functions and scatter kernels required for ESSE were computed using the SIMIND MC simulation code. All Ra-223 photon emissions as well as gamma rays from the daughters Rn-219 and Bi-211 were modeled. Results: The sensitivity of the camera in the three combined windows was 107.3 cps/MBq. The visual quality of the SPECT images was reasonably good and the activity in the sphere was 27% smaller than the true activity. This underestimation is likely due to partial volume effect. Conclusion: Absolute quantitative Ra-223 SPECT imaging is achievable with careful attention to compensate for image degrading factors and system calibration.

60 APPLIED LIFE SCIENCES↗

Photogrammetry Applied to Wind Tunnel Testing

In image-based measurements, quantitative image data must be mapped to three-dimensional object space. Analytical photogrammetric methods, which may be used to accomplish this task, are discussed from the viewpoint of experimental fluid dynamicists. The Direct Linear Transformation (DLT) for camera calibration, used in pressure sensitive paint, is summarized. An optimization method for camera calibration is developed that can be used to determine the camera calibration parameters, including those describing lens distortion, from a single image. Combined with the DLT method, this method allows a rapid and comprehensive in-situ camera calibration and therefore is particularly useful for quantitative flow visualization and other measurements such as model attitude and deformation in production wind tunnels. The paper also includes a brief description of typical photogrammetric applications to temperature- and pressure-sensitive paint measurements and model deformation measurements in wind tunnels.

Liu, Tian-Shu↗

Improving lung cancer prognosis assessment by incorporating synthetic minority oversampling technique and score fusion method

Purpose: This study aims to investigate the potential to improve lung cancer recurrence risk prediction performance for stage I NSCLS patients by integrating oversampling, feature selection, and score fusion techniques and develop an optimal prediction model. Methods: A dataset involving 94 early stage lung cancer patients was retrospectively assembled, which includes CT images, nine clinical and biological (CB) markers, and outcome of 3-yr disease-free survival (DFS) after surgery. Among the 94 patients, 74 remained DFS and 20 had cancer recurrence. Applying a computer-aided detection scheme, tumors were segmented from the CT images and 35 quantitative image (QI) features were initially computed. Two normalized Gaussian radial basis function network (RBFN) based classifiers were built based on QI features and CB markers separately. To improve prediction performance, the authors applied a synthetic minority oversampling technique (SMOTE) and a BestFirst based feature selection method to optimize the classifiers and also tested fusion methods to combine QI and CB based prediction results. Results: Using a leave-one-case-out cross-validation (K-fold cross-validation) method, the computed areas under a receiver operating characteristic curve (AUCs) were 0.716 ± 0.071 and 0.642 ± 0.061, when using the QI and CB based classifiers, respectively. By fusion of the scores generated by the two classifiers, AUC significantly increased to 0.859 ± 0.052 (p < 0.05) with an overall prediction accuracy of 89.4%. Conclusions: This study demonstrated the feasibility of improving prediction performance by integrating SMOTE, feature selection, and score fusion techniques. Combining QI features and CB markers and performing SMOTE prior to feature selection in classifier training enabled RBFN based classifier to yield improved prediction accuracy.

60 APPLIED LIFE SCIENCES↗