At least 91 records · Page 5

Mass Loading Characteristics of Crystal Clock Oscillators

The 10-MHz piezoelectric quartz-crystal microbalance (QCM) has been used extensively for stratospheric aerosol sampling. We have undertaken laboratory studies of the QCM response to mass loading by trace gases. However, this device requires dual oscillator circuitry and the mass sensitivity can often be affected by the electronics. The coatings on the quartz crystals are sometimes difficult to remove after they have reacted with a particular gas and a disposable crystal system would be desirable. The cost of the dual oscillator-based QCM makes this a prohibitive option. Since our goal is to develop a cost-effective microbalance system with stable electronics we have begun testing of crystal clock oscillators, which are assembled with their own circuitry. We have been using chemically specific coatings for ozone to determine if the sensitivity and mass-frequency ratios are comparable to that of the 10-MHz QCM.

Cobb, Janel↗

Analysis of Observed Contamination Through SAGE III's First Year on Orbit

SAGE III is a payload on the International Space Station that conducts measurements of ozone and other atmospheric constituents through the use of a moderate resolution spectrometer with an operating wavelength range of 290 nm to 1550 nm. Because of the optically sensitive nature of the payload, a suite of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) were included to monitor the operating environment. During the rst year of operation, the SAGE III TQCMs were instrumental in detecting several periods of higher contamination and localizing their sources. A clear window made from quartz crystal covers the instrument assembly's aperture. Under nominal operating conditions, this window is only open during science gathering activities. However, if the rates of contamination accumulation are detected to be above the background rate, the window will be kept closed during science gathering to protect the optically sensitive instrument mirror. An analysis of the signal transmissions through the window for the wavelengths of 290 nm to 1550 nm has been conducted to determine any possible degradation of the window and potential in uence on science data collected to date, and established a baseline for future analysis.

Thompson, Michael P.↗

Small Business Innovations (Mass Microbalance)

Femtometrics of Costa Mesa, CA, developed the Model 200-1 SAW Mass Microbalance under a NASA Small Business Innovation Research (SBIR) contract with Langley Research Center. The product is described as "the next generation of aerosol mass microbalance technology," because a new type of sensor, the Surface Acoustic Wave (SAW) piezoelectric crystal, offers mass resolution two orders of magnitude greater than the Quartz Crystal Microbalance cascade impactor (QCM) (used at Langley since 1979 for collection and measurement of aerosol particles in the upper atmosphere). The Model 200-1 SAW Mass Microbalance, which provides a 400-fold increase in mass sensitivity per unit area over the QCM, can be used for real-time particle monitoring in clean rooms, measuring chemical vapors in very low concentrations, measuring target chemicals in the stratosphere and in industry as a toxic vapor monitor.

Source record↗

Contaminant characterization of five satellite materials

An extensive laboratory test program was performed to characterize outgassing of five satellite materials. The materials were Chemglaze Z-306 over 9922 primer, M-773 adhesive, multilayer insulation, polyurethane foam, and silverized Teflon. The souces were prepared to the specifications of a typical satellite program. Dynamic thermogravimetric mass loss characteristics of these five materials were obtained in vacuum with a beam microbalance. The temperature of the material was linearly raised from 25 C to over 650 C while monitoring the mass loss, rate of mass loss, temperature, and the composition of the outgassed material by residual gas analysis. Isothermal source emission/capture coefficients/reemission parameters were obtained with an array of quartz crystal microbalances (QCM). A detailed test matrix in which the temperatures of the QCMs (-160 C, - 100 C, -40 C, and +10 C) and the source material (125 C, and 90 C, and 50 C) were varied was performed. The array of QCMs was also used to measure the spatial distribution of the source emission. The effects of vacuum ultraviolet radiation on the deposition and reemission parameters was determined.

Muscari, J. A.↗

Material Outgassing, Identification and Deposition, MOLIDEP System

The outgassing tests are performed employing a modified vacuum operated Cahn analytical microbalance, identified as the MOLIDEP system. The test measures under high vacuum, the time varying Molecular mass loss of a material sample held at a chosen temperature; it Identifies the outgassing molecular components using an inline SRS 300 amu Residual Gas Analyzer (RGA) and employs a temperature controlled 10 MHz Quartz Crystal Microbalance (QCM) to measure the condensable DEPosits. Both the QCM and the RGA intercept within the conductive passage the outgassing products being evacuated by a turbomolecular pump. The continuous measurements of the mass loss, the rate of loss, the sample temperature, the rate of temperature change, the QCM temperature and the QCM recorded condensable deposits or rate of deposits are saved to an Excel spreadsheet. A separate computer controls the RGA.

Scialdone, John J.↗

SAGE III ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2π steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the ight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

SAGE III/ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2pi steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the flight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

Machine Learning-Enabled Correlation and Modeling of Multimodal Response of Thin Film to Environment on Macro and Nanoscale Using “Lab-on-a-Crystal”

To close the feedback loop between artificial intellegence-controlled materials synthesis and characterization, material functionality must be rapidly tested. A platform for high-throughput multifunctional materials characterization is developed using a quartz crystal microbalance with auxiliary in-plane electrodes and a custom gas/vapor flow cell, enabling simultaneous scanning probe microscopy and electrical, optical, gravimetric, and viscoelastic characterization on the same film under controlled environment. The lab-on-a-crystal in situ multifunctional output allows direct correlations between the gravimetric/viscoelastic, electrical, and optical responses of polymer film in response to environment. Finally, when multiple film properties are used to augment the training set for machine learning regression, prediction of material response to the environment improves by a factor of 13 when <5% of the total dataset is used for model training.

36 MATERIALS SCIENCE↗

Anion Exchange Ionomers: Impact of Chemistry on Thin-Film Properties

Ionomer thin-films (i.e., 20–100 nm) on supports serve as model systems to understand ionomer-catalyst interfacial behavior as well as the confinement-driven deviation in properties from bulk membranes. While ionomer thin-films have been examined for proton exchange ionomers, the thin-film properties of anion exchange ionomers (AEIs) remain largely unexplored. More importantly, delineating the convoluted impact of chemistry and confinement on thin-film morphology and hydration is of interest to advancing the field on functional ionic interfaces. In this work, these aspects are studied by using AEIs of different backbones (perfluorinated, aliphatic, and aromatic) and side chains (various lengths, and single versus dual functional groups). Quartz-crystal microbalance and spectroscopic ellipsometry are used to analyze density and coupled with calculated free volume fraction of thin-films to provide insights on their gas transport properties. AEI side-chain's chemical character plays a key role in how confinement modulates hydration (in thin-film versus bulk). Overall, the results elucidate the effects of backbone, side-chain chemistry versus anion/cation type in the confinement-driven changes in thin-film morphology and swelling. This study also provides new insights for tuning AEI transport functionalities at interfaces via chemistry, which can benefit the design and development of electrode-ionomers for alkaline membrane-based energy systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Role of Side Chains and Hydration on Mixed Charge Transport in n ‐Type Polymer Films

Abstract Introducing ethylene glycol (EG) side chains to a conjugated polymer backbone is a well‐established synthetic strategy for designing organic mixed ion‐electron conductors (OMIECs). However, the impact that film swelling has on mixed conduction properties has yet to be scoped, particularly for electron‐transporting (n‐type) OMIECs. Here, the authors investigate the effect of the length of branched EG chains on mixed charge transport ofn‐type OMIECs based on a naphthalene‐1,4,5,8‐tetracarboxylic‐diimide‐bithiophene backbone. Atomic force microscopy (AFM), grazing‐incidence wide‐angle X‐ray scattering (GIWAXS), and scanning tunneling microscopy (STM) are used to establish the similarities between the common‐backbone films in dry conditions. Electrochemical quartz crystal microbalance with dissipation monitoring (EQCM‐D) and in situ GIWAXS measurements reveal stark changes in film swelling properties and microstructure during electrochemical doping, depending on the side chain length. It is found that even in the loss of the crystallite content upon contact with the aqueous electrolyte, the films can effectively transport charges and that it is rather the high water content that harms the electronic interconnectivity within the OMIEC films. These results highlight the importance of controlling water uptake in the films to impede charge transport inn‐type electrochemical devices.

Chemistry↗

Modeling of deposit formation in mesoporous substrates via atomic layer deposition: Insights from pore‐scale simulation

Atomic layer deposition (ALD) has been a promising technique in fabricating membranes and tuning their properties with a precision at the atomic level. Fabrication of zeolitic imidazolate framework (ZIF) membranes using the ligand-induced permselectivation (LIPS) method starts with the formation of an oxide in a mesoporous substrate by ALD and is followed by the transformation of this oxide to ZIF using imidazolate vapor treatment. The objective of the ALD step is to block the mesopores with a thin deposit, that is, one with small penetration depth and small thickness on the top surface of the substrate. Unlike typical ALD on nonporous substrates, where all available sites react per ALD cycle, thin deposit formation in a mesoporous substrate requires that only a small fraction of the available deposition sites (i.e., close to the substrate surface) is subjected to ALD. Consequently, reactant dosing and duration of pulses are important process variables which, together with diffusion and reaction kinetics determine the deposit structure. Quantitative understanding of the interplay of these variables and phenomena can enable the rational design of ALD within mesoporous substrates. Here, we extend our earlier modeling effort considering the coexistence of ALD both inside the pores and on the external surface of the substrate. Finite-volume based models were developed and validated to simulate the two distinct modes of deposition cycle by cycle. The total mass uptake of the substrate with ALD cycles can be predicted using the combined surface deposition and pore reaction–diffusion models as affirmed by in situ quartz crystal microbalance experimental data. The ALD reactor model combined with the deposition model can accurately capture the number of ALD cycles needed to block the pores of the substrate. Based on the model, we designed a modified ALD process and examined the performance of the corresponding LIPS membranes. Furthermore, the present modeling work provides a new understanding of the deposit formation via ALD within mesoporous substrates for a variety of membrane applications.

atomic layer deposition↗

Solution–Processable Thermally Crosslinked Organic Radical Polymer Battery Cathodes

Organic radical polymers are promising cathode materials for next-generation batteries because of their rapid charge transfer and high cycling stability. However, these organic polymer electrodes gradually dissolve in the electrolyte, resulting in capacity fade. Several crosslinking methods have been developed to improve the performance of these electrodes, but they are either not compatible with carbon additives or compromise the solution processability of the electrodes. A one-step post-synthetic, carbon-compatible crosslinking method was developed to effectively crosslink an organic polymer electrode and allow for easy solution processing. The highest electrode capacity of 104 mAh g –1 (vs. a theoretical capacity of 111 mAh g –1 ) is achieved by introducing 1 mol % of the crosslinker, whereas the highest capacity retention (99.6 %) is obtained with 3 mol % crosslinker. In addition, mass transfer was observed in situ by using electrochemical quartz crystal microbalance with dissipation monitoring. Furthermore, these results may guide future electrode design toward fast-charging and high-capacity organic electrodes.

25 ENERGY STORAGE↗

The Importance of Decarbonylation Mechanisms in the Atomic Layer Deposition of High-Quality Ru Films by Zero-Oxidation State Ru(DMBD)(CO) 3

Achieving facile nucleation of noble metal films through atomic layer deposition (ALD) is extremely challenging. To this end, η 4 -2,3-dimethylbutadiene ruthenium tricarbonyl (Ru(DMBD)(CO) 3 ), a zero-valent complex, has recently been reported to achieve good nucleation by ALD at relatively low temperatures and mild reaction conditions. Here, we study the growth mechanism of this precursor by in situ quartz-crystal microbalance and quadrupole mass spectrometry during Ru ALD, complemented by ex situ film characterization and kinetic modeling. These studies reveal that Ru(DMBD)(CO) 3 produces high-quality Ru films with excellent nucleation properties. This results in smooth, coalesced films even at low film thicknesses, all important traits for device applications. However, Ru deposition follows a kinetically limited decarbonylation reaction scheme, akin to typical CVD processes, with a strong dependence on both temperature and reaction timescale. The non-self-limiting nature of the kinetically driven mechanism presents both challenges for ALD implementation and opportunities for process tuning. By surveying reports of similar precursors, we suggest that the findings can be generalized to the broader class of zero-oxidation state carbonyl-based precursors used in thermal ALD, with insight into the design of effective saturation studies.

chemical vapor deposition↗

Vapor-phase grafting of a model aminosilane compound to Al 2 O 3 , ZnO, and TiO 2 surfaces prepared by atomic layer deposition

Atomic layer deposition (ALD) is a highly versatile surface functionalization technique that can conformally coat both planar and porous substrates. Here we use ALD metal oxide layers to establish a well-defined starting surface for vapor-phase surface organic modification. Vapor-phase (3-aminopropyl)triethoxysilane (APTES) surface silanization of ALD Al 2 O 3 , ZnO and TiO 2 surfaces were studied at 100 °C, 150 °C and 200 °C. In situ quartz crystal microbalance (QCM) and Fourier-transform infrared (FTIR) spectroscopy measurements, and ex situ atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) measurements showed uniform monolayer silane formation through self-limiting APTES reaction. We observed a higher surface density of grafted APTES species following silanization at 100 °C compared to 200 °C, and we attribute this to the temperature-dependent reactivity of the surface hydroxyls and changes in the mode of APTES reaction. The FTIR and XPS measurements revealed that APTES reacts with Al 2 O 3 and ZnO exclusively through metal siloxy bond formation. However, APTES reacts with TiO 2 through both siloxy bond formation and ammonium salt formation via the amine group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unlocking the secret of lignin-enzyme interactions: Recent advances in developing state-of-the-art analytical techniques

Bioconversion of renewable lignocellulosics to produce liquid fuels and chemicals is one of the most effective ways to solve the problem of fossil resource shortage, energy security, and environmental challenges. Among the many biorefinery pathways, hydrolysis of lignocellulosics to fermentable monosaccharides by cellulase is arguably the most critical step of lignocellulose bioconversion. In the process of enzymatic hydrolysis, the direct physical contact between enzymes and cellulose is an essential prerequisite for the hydrolysis to occur. However, lignin is considered one of the most recalcitrant factors hindering the accessibility of cellulose by binding to cellulase unproductively, which reduces the saccharification rate and yield of sugars. This results in high costs for the saccharification of carbohydrates. The various interactions between enzymes and lignin have been explored from different perspectives in literature, and a basic lignin inhibition mechanism has been proposed. However, the exact interaction between lignin and enzyme as well as the recently reported promotion of some types of lignin on enzymatic hydrolysis is still unclear at the molecular level. Multiple analytical techniques have been developed, and fully unlocking the secret of lignin-enzyme interactions would require a continuous improvement of the currently available analytical techniques. This review summarizes the current commonly used advanced research analytical techniques for investigating the interaction between lignin and enzyme, including quartz crystal microbalance with dissipation (QCM-D), surface plasmon resonance (SPR), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, atomic force microscopy (AFM), nuclear magnetic resonance (NMR) spectroscopy, fluorescence spectroscopy (FLS), and molecular dynamics (MD) simulations. Interdisciplinary integration of these analytical methods is pursued to provide new insight into the interactions between lignin and enzymes. Finally, this review will serve as a resource for future research seeking to develop new methodologies for a better understanding of the basic mechanism of lignin-enzyme binding during the critical hydrolysis process.

59 BASIC BIOLOGICAL SCIENCES↗

Graphene-polyelectrolyte multilayer membranes with tunable structure and internal charge

One great advantage of graphene-polyelectrolyte multilayer (GPM) membranes is their tunable structure and internal charge for improved separation performance. In this study, we synthesized GO-dominant GPM membrane with internal negatively-charged domains, polyethyleneimine (PEI)-dominant GPM membrane with internal positively-charged domains and charge-balanced dense/loose GPM membranes by simply adjusting the ionic strength and pH of the GO and PEI solutions used in layer-by-layer membrane synthesis. A combined system of quartz crystal microbalance with dissipation (QCM-D) and ellipsometry was used to analyze the mass deposition, film thickness, and layer density of the GPM membranes. The performance of the GPM membranes were compared in terms of both permeability and selectivity to determine the optimal membrane structure and synthesis strategy. One effective strategy to improve the GPM membrane permeability-selectivity tradeoff is to assemble charge-balanced dense membranes under weak electrostatic interactions. This balanced membrane exhibits the highest MgCl 2 selectivity (~86%). Another effective strategy for improved cation removal is to create PEI-dominant membranes that provide internal positively-charged barrier to enhance cation selectivity without sacrificing water permeability. Finally, these findings shine lights on the development of a systematic approach to push the boundary of permeability-selectivity tradeoff for GPM membranes.

42 ENGINEERING↗

Optimization of fluorescence and surface adsorption of citric acid/ethanolamine carbon nanoparticles for subsurface tracers

The tunable fluorescence and biocompatibility of fluorescent carbon nanoparticles (FCNs) makes them appealing tracers in geothermal, environmental, and clinical applications. Here, we address FCNs synthesized from reaction and pyrolysis of citric acid and ethanolamine. We examine the fluorescence and the adsorption of these FCNs as critical parameters that influence their use in applications. FCN fluorescence was observed to develop during pyrolysis and measured at pyrolysis temperatures ranging from 190 to 250 °C. Transmission electron microscopy shows that the FCN average diameter of approximately 13 nm is unaffected by pyrolysis temperature. However, pyrolysis temperature strongly affects fluorescence, which peaks at 210 °C. Here, the surface hydrophobicity of the FCNs increases with pyrolysis temperature as measured by retention on reverse phase chromatography. Together, these results suggest that particle surface functionalities provide both fluorescence and hydrophilicity, and that these surface functionalities are destroyed with excessive pyrolysis. To examine their surface adsorption, quartz crystal microbalance measurements demonstrate that pyrolysis temperature increases FCN adsorption on mineral surfaces. Surfaces with greater hydrophobicity show greater FCN adsorption. Adsorption is unaffected by the presence of mono- or divalent ions in solution. This suggests adsorption by hydrophobic interaction for the Fe 2 O 3 , SiO 2 , and AlSiO surfaces studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitatively controlled electrophoretic deposition of nanocrystal films from non-aqueous suspensions

This study presents a novel method to correlate the mass and charge transfer kinetics during the electrophoretic deposition of nanocrystal films by using a purpose-built double quartz crystal microbalance combined with simultaneous current-measurement. Our data support a multistep process for film formation: generation of charged nanocrystal flux, charge transfer at the electrode, and polarization of neutral nanocrystals near the electrode surface. The polarized particles are then subject to dielectrophoretic forces that reduce diffusion away from the interface, generating a sufficiently high neutral particle concentration at the interface to form a film. The correlation of mass and charge transfer enables quantification of the nanocrystal charge, the fraction of charged nanocrystals, and the initial sticking coefficient of the particles. These quantities permit calculation of the film thickness, providing a theoretical basis for using concentration and voltage as process parameters to grow films of targeted thicknesses.

77 NANOSCIENCE AND NANOTECHNOLOGY↗