Search NASA⌕ Search

SEARCH · Search NASA

Results for “quench detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Stereoscopic detection of hot spots in superfluid 4 He (He II) for accelerator-cavity diagnosis

Superconducting radio-frequency (SRF) cavities cooled by superfluid 4He (He II) are building blocks of many modern particle accelerators due to their high quality factor. However, Joule heating from sub-millimeter surface defects on cavities can lead to cavity quenching, which limits the maximum acceleration gradient of the accelerators. Developing a non-contacting detection technology to accurately locate these surface hot spots is the key to improve the performance of SRF cavities and hence the accelerators. In a recent proof-of-concept experiment, we demonstrated that a molecular tagging velocimetry (MTV) technique based on the tracking of a He molecular tracer line created nearby a surface hot spot in He II can be utilized to locate the hot spot. In order to make this technique practically useful, here we describe our further development of a stereoscopic MTV setup for tracking the tracer line’s motion in three-dimensional (3D) space. We simulate a quench spot by applying a transient voltage pulse to a small heater mounted on a substrate plate. Images of the drifted tracer line, taken with two cameras from orthogonal directions, are used to reconstruct the line profile in 3D space. Here, a new algorithm for analyzing the 3D line profile is developed, which incorporates the finite size effect of the heater. We show that the center location of the heater can be reproduced on the substrate surface with an uncertainty of only a few hundred microns, thereby proving the practicability of this method.

43 PARTICLE ACCELERATORS↗

Luminescent Metal–Organic Framework for the Selective Detection of Aldehydes

The detection of toxic, hazardous chemical species is an important task because they pose serious risks to either the environment or human health. Luminescent metal–organic frameworks (LMOFs) as alternative sensors offer rapid and sensitive detection of chemical species. Interactions between chemical species and LMOFs result in changes in the photoluminescence (PL) profile of the LMOFs which can be readily detected using a simple fluorometer. Herein, we report the use of a robust, Zn-based LMOF, [Zn 5 (μ 3 -OH) 2 (adtb) 2 (H 2 O) 5 ·5 DMA] (Zn-adtb, LMOF-341), for the selective detection of benzaldehyde. Upon exposure to benzaldehyde, Zn-adtb experiences significant luminescent quenching, as characterized through PL experiments. Photoluminescent titration experiments reveal that LMOF-341 has a detection limit of 64 ppm and a Ksv value of 179 M –1 for benzaldehyde. Furthermore, we study the guest–host interactions that occur between LMOF-341 and benzaldehyde through in situ Fourier transform infrared and computational modeling employing density functional theory. The results show that benzaldehyde interacts more strongly with LMOF-341 compared to formaldehyde and propionaldehyde. Furthermore, our combined studies also reveal that the mechanism of luminescence quenching originates from an electron-transfer process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ageing and quenching through the Ageing Diagram – II. Physical characterization of galaxies

The connection between quenching mechanisms, which rapidly turn star-forming systems into quiescent, and the properties of the galaxy population remains difficult to discern. In this work we investigate the physical properties of MaNGA and SAMI galaxies at different stages of their star formation history. Specifically, we compare galaxies with signatures of recent quenching (Quenched) – Hα in absorption and low D n (4000) – with the rest of the low star-forming and active population (Retired and Ageing, respectively). The analysis is performed in terms of characteristics such as the total stellar mass, half-light radius, velocity-to-dispersion ratio, metallicity, and environment. We find that the Ageing population comprises a heterogeneous mixture of galaxies, preferentially late-type systems, with diverse physical properties. Retired galaxies, formerly Ageing or Quenched systems, are dominated by early-type high-mass galaxies found both at low and dense environments. Most importantly, we find that recently quenched galaxies are consistent with a population of compact low-mass satellite systems, with higher metallicities than their Ageing analogues. We argue that this is compatible with being quenched after undergoing a star-burst phase induced by environmental processes (e.g. ram pressure). However, we also detect a non-negligible fraction of field central galaxies likely quenched by internal processes. This study highlights that, in order to constrain the mechanisms driving galaxy evolution, it is crucial to distinguish between old (Retired) and recently quenched galaxies, thus requiring at least two estimates of the specific star formation rate over different time-scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Applications of Temperature and Pressure Sensitive Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of a luminescent paint is described followed by applications in low speed, transonic, supersonic and cryogenic wind tunnels and in rotating machinery.

Liu, Tian-Shu↗

Pressure and Temperature Sensitive Paint Measurements on Rotors

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence, which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. The basic photophysics, calibration, accuracy and time response of luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John↗

Surface Measurement Techniques Temperature and Pressure Sensitive Paints

Luminescent molecular probes imbedded in a polymer binder form a temperature or pressure paint. On excitation by light of the proper wavelength, the luminescence,which is quenched either thermally or by oxygen, is detected by a camera or photodetector. From the detected luminescent intensity, temperature and pressure can be determined. Tl e basic photophysics, calibration, accuracy and the response of a luminescent paints is described followed by applications in wind tunnels and in rotating machinery.

Sullivan, John P.↗

Photochemistry of bromoacetylene - Formation of HBr and quenching of excited Br/4 2P 0 1/2/

The photolysis of bromacetylene is examined by means of vacuum ultraviolet flash photolysis-kinetic spectroscopy, with attention given to the production of Br atoms in the 2P 0 3/2 and 2P 0 1/2 states, the production of HBr, and UV absorption attributable to the ethynyl radical. Although Br(2P 0 1/2) and Br(2P 0 3/2) were both directly observed at the shortest delay time after the flash, strongly indicating the presence of the ethynyl radical, transient absorption by C2H was not detected in the range 125 to 180 nm. Quenching rate constants for the decay of the 2P 0 1/2 state of Br, which is observed to form concurrently with the ground state, are derived for quenching by He, CH2Br, CF4, and D2 from the pseudo-first-order decay rates. HBr was observed as a secondary photolysis product, and a model of its formation by the exothermic reaction of ground-state atoms with C2HBR, coupled with the secondary production of Br atoms, is found to agree well with the experiment.

Laufer, A. H.↗

Quantum-enhanced detection of viral cDNA via luminescence resonance energy transfer using upconversion and gold nanoparticles

Abstract The COVID-19 pandemic has profoundly impacted global economies and healthcare systems, revealing critical vulnerabilities in both. In response, our study introduces a sensitive and highly specific detection method for cDNA, leveraging Luminescence Resonance Energy Transfer (LRET) between upconversion nanoparticles (UCNPs) and gold nanoparticles (AuNPs), and achieves a detection limit of 242 fM for SARS-CoV-2 cDNA. This innovative sensing platform utilizes UCNPs conjugated with one primer and AuNPs with another, targeting the 5′ and 3′ ends of the SARS-CoV-2 cDNA, respectively, enabling precise differentiation of mismatched cDNA sequences and significantly improving detection specificity. Through rigorous experimental analysis, we established a quenching efficiency range from 10.4 % to 73.6 %, with an optimal midpoint of 42 %, thereby demonstrating the superior sensitivity of our method. Our work uses SARS-CoV-2 cDNA as a model system to demonstrate the potential of our LRET-based detection method. This proof-of-concept study highlights the adaptability of our platform for future diagnostic applications. Instrumental validation confirms the synthesis and formation of AuNPs, addressing the need for experimental verification of the preparation of nanomaterial. Our comparative analysis with existing SARS-CoV-2 detection methods revealed that our approach provides a low detection limit and high specificity for target cDNA sequences, underscoring its potential for targeted COVID-19 diagnostics. This study demonstrates the superior sensitivity and adaptability of using UCNPs and AuNPs for cDNA detection, offering significant advances in rapid, accessible diagnostic technologies. Our method, characterized by its low detection limit and high precision, represents a critical step forward in developing next-generation biosensors for managing current and future viral outbreaks. By adjusting primer sequences, this platform can be tailored to detect other pathogens, contributing to the enhancement of global healthcare responsiveness and infectious disease control.

Esmaeili, Shahriar [Institute for Quantum Science ↗

Seasonal/Diurnal Mapping of Ozone and Water in the Martian Atmosphere

Ozone and water are key species for understanding the stability and evolution of Mars atmosphere; they are closely linked (along with CO, H, OH, and O) through photochemistry. Photolysis of water produces the OH radical (thought to catalyze reformation of CO2 from CO and O2) and atomic hydrogen (which reacts with O3 forming OH and O2). Atomic hydrogen also reacts with O2 (forming HO2), thereby reducing the amount of O2 available to reform O3 from collisions between O and O2. Hence ozone and water should be anti-correlated on Mars. Photolysis of O3 produces O2(a(sup 1) delta g) with 90% efficiency, and the resulting emission band system near 1.27 mm traces the presence and abundance of ozone. This approach was initially used to study ozone on Earth and then applied to Mars. In 1997, we measured several lines of the O2(a(sup 1) delta g) emission using CSHELL at the NASA IRTF; the O2(a(sup 1) delta g) state is also quenched by collisions with CO2. This quenching dominates at lower altitudes so that the detected emissions are used to detect ozone column densities above ~20 km. The slit was positioned N-S along Mars' central meridian resulting in a one-dimensional map of ozone. Nearly simultaneous maps may be made of water using CSHELL by detecting the v1 fundamental band of HDO near 3.67 microns and using the D/H ratio for Mars. This technique was used by DiSanti and Mumma. With CSHELL, measurements for both O2(a(sup 1) delta g) emissions and HDO absorptions can be made during the day or night. Since January, 1997, we have repeated these measurements at different times during the Martian year. For all of these dates, we have positioned the slit N-S along the central meridian; for some of these dates, we have also stepped the slit across the planet at 1 arc-sec intervals generating a 2-dimensional map. We have also positioned the slit E-W on Mars thus providing diurnal variations of ozone and water along the slit.

Novak, R. E.↗

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature dependent electronic quenching of OH(A 2 Sigma +, v-prime = 0) between 230 and 310 K

The present study is concerned with the electronic quenching of OH(A 2 Sigma +, v-prime = 0) at and below room temperature, taking into account the use of laser-induced fluorescence (LIF) in a low pressure flow cell for H2, CO2, O2, and N2 colliders. The reasons for the selection of the temperature range and the collision partners are related to the quantitative calibration of OH detection techniques in the troposphere, and to considerations of electronic quenching dynamics. Attention is given to production and rotational distribution, temperature measurements, and temperature dependent quenching rate constants.

Copeland, R. A.↗

Identification of the Ga interstitial in Al(x)Ga(1-x)As by optically detected magnetic resonance

A new optically detected magnetic resonance spectrum in Al(x)Ga(1-x)As is reported and assigned to native Ga interstitials. Luminescence-quenching signals were observed over the energy region from 0.75 to 1.1 eV. The optically detected magnetic resonance is nearly isotropic, with spin-Hamiltonian parameters g = 2.025 + or - 0.006, central hyperfine splitting A(Ga-69) = 0.050 + or - 0.001/cm, and A(Ga-71) = 0.064 + or - 0.001/cm for H near the 001 line. The strong hyperfine coupling denotes an electronic state of A1 symmetry, which current theories predict for the Ga interstitial but not the Ga antisite. The slight anisotropy probably indicates that the Ga(i) is paired with a second, unknown defect.

Kennedy, T. A.↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics

The amount of light produced by nuclear recoils in scintillating targets is strongly quenched compared to that produced by electrons. A precise understanding of the quenching factor is particularly interesting for weakly interacting massive particles (WIMP) searches and coherent elastic neutrino-nucleus scattering ( CE ν NS ) measurements since both rely on nuclear recoils, whereas energy calibrations are more readily accessible from electron recoils. There is a wide variation among the current measurements of the quenching factor in sodium iodide (NaI) crystals, especially below 10 keV, the energy region of interest for dark matter and CE ν NS studies. A better understanding of the quenching factor in NaI(Tl) is of particular interest for resolving the decades-old puzzle in the field of dark matter between the null results of most WIMP searches and the claim for dark matter detection by the DAMA/LIBRA collaboration. In this work, we measured sodium and iodine quenching factors for five small NaI(Tl) crystals grown with similar thallium concentrations and growth procedures. Unlike previous experiments, multiple crystals were tested, with measurements made in the same experimental setup to control systematic effects. The quenching factors agree in all crystals we investigated, and both sodium and iodine quenching factors are smaller than those reported by DAMA/LIBRA. The dominant systematic effect was due to the electron equivalent energy calibration originating from the nonproportional behavior of the NaI(Tl) light yield at lower energies, potentially the cause for the discrepancies among the previous measurements. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aqueous phosphate detection using Eu(acac) 3

Currently, the majority of phosphate-sensitive phosphors reported in literature are metal-based complexes that require complicated and expensive synthesis to prepare. Here, in this study, we investigate the phosphate detecting capabilities of an inexpensive off-the-shelf phosphor: Eu(acac) 3 . We characterize its phosphate sensitivity as a function of sensor concentration and find that the quenching coefficient is inversely proportional to sensor concentration. This results in the limit-of-detection scaling linearly with sensor concentration. We determine its concentration-independent sensitivity to be 1.558 ± 0.012, which results in our lowest sensor concentration (44 μM) having a limit-of-detection of 3.39 ± 0.68 μM. We also find that for phosphate concentrations less than the sensor concentration, the fluorescence intensity ratio behaves linearly, but transitions to a non-linear functionality as the phosphate concentration exceeds the sensor concentration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Orbital-Selective Instabilities and Spin Fluctuations at the Verge of Superconductivity in Interlayer-Expanded Iron Selenide

Understanding electron correlation-driven instabilities and their coupling to structural phases is essential for deciphering multiorbital pairing in unconventional superconductors. We investigate Li x (C 5 H 5 N) y Fe 2 Se 2 (x ∼ 0.6; y ∼ 0.7−0.9), a tetragonal β-FeSe intercalate with a superconducting transition temperature (T c = 39 K) closely tied to an expanded Fe-layer spacing (∼11.4 Å). High-resolution synchrotron Xray diffraction and core-level absorption spectroscopy reveal subtle lattice distortions on cooling without a symmetry-breaking transition. Instead, the material exhibits negative thermal expansion (NTE) in the two-dimensional Fe network below T S ∼ 70 K, and stiffening of local Se−Fe−Se bond dynamics near T c . The spatially incoherent rearrangement of FeSe 4 tetrahedra and the site-local fluctuations, signal reduced electron correlations compared to those of parent β-FeSe (T c = 8 K). Complementary X-ray emission spectroscopy, a fast local probe of Fe 3d valence states, detects persistent local Fe spin moments below T S , unlike quenching in related systems. These findings indicate that decoupling of Fe planes leads to an electronically driven lattice instability. The latter emerges as NTE induced from weak, orbital-selective localization of in-plane Fe 3d states rather than conventional transverse vibrations. Governed by Hund’s coupling, this selectivity permits coexistence of local spin fluctuations with itinerant d-electrons critical for enhancing T c . These results suggest that intercalation-driven d-orbital differentiation moderates electron correlations, providing a pathway to optimize the superconductivity in low-dimensional quantum materials.

36 MATERIALS SCIENCE↗

Undercooling and solidification behavior in the InSb-Sb system

Use of the droplet emulsion technique has been successful in studying the undercooling and crystallization behavior of Sb, InSb, and an InSb-Sb eutectic alloy. Both droplet size and imposed cooling rate were influential in controlling the extent of liquid undercooling. The droplet surface coating was of significant importance in determining the resultant solidification product structure through its effect on nucleation kinetics. The maximum undercooling for pure Sb was extended from 0.08 to 0.23 T sub m. While simple crushing techniques provided a dramatic increase in droplet undercooling over the bulk material, emulsification treatments both enhanced this undercooling and allowed successful formation of a metastable simple cubic Sb phase. This phase was stable to temperatures approaching the melting point. The simple cubic phase was detected in droplet samples processed using DTA, air and water quenching, and drop tube processing under a helium gas atmosphere. A deviation in the InSb parent ingot composition limited interpretation of the line compound results, however, emulsification techniques extended the undercooling of this material to 0.17 T sub L and provided a stable, protective surface coating for the droplets. Emulsification of the eutectic alloy was effective at producing various levels of undercooling from 0.1 to 0.2 T sub E. Microstructural examination revealed a normal-type eutectic structure in the undercooled droplets indicating that solidification occurred within the coupled zone and that this zone is somewhat symmetric about the eutectic composition.

Graves, J. A.↗