Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiation source detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Algorithm Implementation for a Prototype Time-Encoded Signature Detector

The authors constructed a prototype Time-Encoded Signature (TES) system, complete with automated detection algorithms, useful for the detection of point-like, gamma-ray sources in search applications where detectors observe large variability in background count rates beyond statistical (Poisson) noise. The person-carried TES instrument consists of two Cesium Iodide scintillators placed on opposite sides of a Tungsten shield. This geometry mitigates systematic background variation, and induces a unique signature upon encountering point-like sources. This manuscript focuses on the development of detection algorithms that both identify point-source signatures and are computationally simple. The latter constraint derives from the instrument’s mobile (and thus low power) operation. The authors evaluated algorithms on both simulated and field data. The results of this analysis demonstrate the ability to detect sources at a wide range of source-detector distances using computationally simple algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms for the determination of the time delays of the signal when using unequal detectors

In treating the recorded results from detectors at different locations in space, the analysis of the time delays of signals is crucial to locating the sources of detected radiation. Because the correlation method requires the manipulation of awkward matrices to evaluate its accuracy, a solution is outlined based on minimizing the sum of the squares of signal deviations, and the algorithms for evaluating the resulting error are presented.

Novak, B. L.↗

Efficiency Calibration of 4{pi} NaI(Tl) Gamma-ray Detectors for Plane Sources - Paper 130

4{pi} NaI(Tl) detectors are useful for low level gamma activity measurements due to the near 4{pi} solid angle that can be obtained with them. An analytical theoretical approach is presented here to calculate the absolute efficiencies for this type of detectors. The approach depends on the accurate calculation of two important factors; the path length, d, the photon traverses within the active volume of a gamma detector, and the geometrical solid angle,{Omega}, subtended by the source to the detector at the point of entrance. These two factors are theoretically derived through a straightforward analytical approach. In this work, this model is extended to an isotropic radiating point source, and a thin circular disk source. The results of the present absolute efficiency values were compared with the experimental and M.C. method works reported in the literature. The present theoretical and the experimental efficiency values are in good agreement. The present approach offers a good method to calibrate 4{pi} NaI(Tl) detectors over a large energy range without the need for standard sources, as is the case for experimental methods, nor optimization of detector parameters as for Monte Carlo simulations. Discrepancies with experimental results are reduced to lower than 4%. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FERMI LARGE AREA TELESCOPE GAMMA-RAY DETECTION OF THE RADIO GALAXY M87

We report the Fermi Large Area Telescope (LAT) discovery of high-energy (MeV/GeV) gamma-ray emission positionally consistent with the center of the radio galaxy M87, at a source significance of over 10sigma in 10 months of all-sky survey data. Following the detections of Cen A and Per A, this makes M87 the third radio galaxy seen with the LAT. The faint point-like gamma-ray source has a >100 MeV flux of 2.45 (+-0.63) x 10{sup -8} photons cm{sup -2} s{sup -1} (photon index = 2.26 +- 0.13) with no significant variability detected within the LAT observation. This flux is comparable with the previous EGRET upper limit (<2.18 x 10{sup -8} photons cm{sup -2} s{sup -1}, 2sigma), thus there is no evidence for a significant MeV/GeV flare on decade timescales. Contemporaneous Chandra and Very Long Baseline Array data indicate low activity in the unresolved X-ray and radio core relative to previous observations, suggesting M87 is in a quiescent overall level over the first year of Fermi-LAT observations. The LAT gamma-ray spectrum is modeled as synchrotron self-Compton (SSC) emission from the electron population producing the radio-to-X-ray emission in the core. The resultant SSC spectrum extrapolates smoothly from the LAT band to the historical-minimum TeV emission. Alternative models for the core and possible contributions from the kiloparsec-scale jet in M87 are considered, and cannot be excluded.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Selection of Training Sets for 235U Source Detection Classifiers Using Gamma Signatures

The machine learning methods for classifiers to detect low level radiation sources are of interest when suitable training data sets are available. Their application and performance assessment, however, involves the aspects of over-fitting and training data selection that are somewhat uncommon in other existing methods for this task.We study U-235 gamma signatures using data sets collected by 21 NaI detectors under controlled conditions. The gamma spectra are collected by the detectors located at different distances from the source, and we study their choice as training sets for classifiers to detect a source. The detectors form the near, middle and outer groups based on the distance to source. The classifiers based on the outer group are susceptible to over-fitting, that is, they achieve low training error but incur much higher testing error in independent tests. The other two groups achieve lower training error and comparable testing error, and the near group achieves the overall lowest error. In detecting a source at an unknown distance, the farther detectors in the middle group achieve the overall lowest testing error with limited over-fitting, thereby indicating the complex dependencies between the training and classifier performance.

Rao, Nageswara↗

Modeling the Effect of High Background Mitigation Techniques on Radiation Portal Monitors

The Oak Ridge National Laboratory (ORNL) has been tasked by the United States National Nuclear Security Administration’s Second Line of Defense (SLD) program with determining a viable method for mitigating high background radiation levels in radiation portal monitors (RPM). High background radiation levels adversely affect the ability of RPMs to detect small sources of radiation. For this reason, it is desirable to install RPMs in low background environments where a low false alarm rate can be achieved and small deviations in detector signals are able to trigger alarms. To investigate the mitigation of high background levels, a test bed was established at ORNL capable of reproducing many factors that contribute to radiation background levels. The controlled environment of the test bed allows the isolation of a variety of factors that influence background and are difficult to accurately characterize in the field. In this work, the test bed is used to characterize numerous RPM configurations encountered in the field and provide a benchmark for modeling RPM background levels. Accurately modeling the background measured by a RPM allows future background remediation techniques to first be modeled to test their validity before being installed in the field. The utilization of these tools can yield a cost savings to the program by minimizing costly field installations and understanding the outcome of remediation techniques prior to widespread implementation.

Guzzardo, Tyler↗

Improvements in the Method of Radiation Anomaly Detection by Spectral Comparison Ratios

Algorithms for detecting illicit gamma radiation sources must respond to a wide variety of threat signatures and ignore a wider variety of clutter. Previously, we described the Nuisance-rejection Spectral Comparison Ratio Anomaly Detection (N-SCRAD) method for indicating the presence of threat sources during mobile search operations. Our method relies on the formulation of radiation alarm test statistics applied to detector counts in numerous spectral regions of interest and our test statistics are standardized by local estimates of background variability. In this work we present a new automated procedure for selecting test statistics and specifying the regions of interest based on minimizing detectable count rates of prototype threat spectra at a specified false positive rate using simulated annealing. The new procedure can be applied to configuring the detection algorithm when the prototype threats are many and diverse without significantly compromising the detection sensitivity to any one of them. N-SCRAD makes use of estimates of background variability obtained during a search from prior measurements of background. In applications such estimates made purely from past measurements sometimes do not extrapolate well to current conditions. In this work we present a new method for correcting those estimates to current conditions of the total count rate. We demonstrate that the correction lowers detection thresholds for a specified false positive rate, enabling greater sensitivity to targets. The two proposed improvements to N-SCRAD maximize detection power for the expected variety of possible threats while reducing or maintaining the false positive rate.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗

Radiograph and passive data analysis using mixed variable optimization

Disclosed herein are representative embodiments of methods, apparatus, and systems for performing radiography analysis. For example, certain embodiments perform radiographic analysis using mixed variable computation techniques. One exemplary system comprises a radiation source, a two-dimensional detector for detecting radiation transmitted through a object between the radiation source and detector, and a computer. In this embodiment, the computer is configured to input the radiographic image data from the two-dimensional detector and to determine one or more materials that form the object by using an iterative analysis technique that selects the one or more materials from hierarchically arranged solution spaces of discrete material possibilities and selects the layer interfaces from the optimization of the continuous interface data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Comparison of the Lightning Imaging Sensor (LIS) with Lightning Detection and Ranging (LDAR)

The mapping of the lightning optical pulses detected by the Lightning Imaging Sensor (LIS) is compared with the radiation sources by Lightning Detection and Ranging (LDAR) and the National Lightning Detection Network (NLDN) for three thunderstorms observed during and overpasses on 15 August 1998. The comparison involves 122 flashes including 42 ground and 80 cloud flashes. For ground flash, the LIS recorded the subsequent strokes and changes inside the cloud. For cloud flashes, LIS recorded those with higher sources in altitude and larger number of sources. The discrepancies between the LIS and LDAR flash locations are about 4.3 km for cloud flashes and 12.2 km for ground flashes. The reason for these differences remain a mystery.

Ushio, Tomoo↗

A Sight on the Variation of Spectral Parameters in GRBs

Gamma ray bursts (GRBs) are high energy photons detected during a short interval of time. They are signs of the most energetic events in the universe. Photons detected show a non thermal spectrum, very well described by the peak energy and two smoothly connected power laws with different slopes or indices. This spectrum is named Band spectrum and serves actually as the most important source of information on their physical origin. It characterizes not only the overall emission, but also the instantaneous one, found in small successive intervals of time during the event. The time-resolved spectra show an obvious evolution in energy, which is generally accepted and supported by several arguments. There is also some evidence in measuring a kind of evolution in slope parameters, which would be considered as a serious source of information for the physical mechanism. In this work we try to examine the limit in observation bands, which we suspect as a reason for the apparent variation in time of spectral indices. Our work is based on a numeric and certified code. We simulate GRBs assuming synchrotron emission in the internal shocks model. For each time-resolved spectrum we find spectral parameters based on the Band function.

79 ASTRONOMY AND ASTROPHYSICS↗

The Fermi Large Area Telescope: Highlights from the first year on orbit

Since its launch from Cape Canaveral on June 11, 2008, the Large Area Telescope (LAT) onboard the Fermi Gamma-ray Space Telescope has been performing a survey of the high-energy astrophysical phenomena, including pulsars, black holes and active galactic nuclei; gamma-ray bursts; the origin of cosmic rays and supernova remnants and searches for new phenomena such as supersymmetric dark-matter annihilation. In this contribution I report on the performance of the LAT and on the highlight results achieved in its first year of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TeV radiation from galactic sources

The detection of the Crab Nebula as a steady source of TeV gamma rays puts the field of Very High Energy Gamma-Ray Astronomy on a firm observational basis and permits a critical reassessment of the claims for the detection of a multitude of episodic binary sources. A new generation of detectors in the TeV and PeV energy regions is coming on-line; together with the telescopes of the Gamma-Ray Observatory, these instruments will present a new perspective on one of the last frontiers of astronomy.

Weekes, Trevor C.↗

New Advanced Source Identification Algorithm (ASIA-NEW) for radiation monitors with plastic detectors

Radiation Portal Monitors (RPM) with plastic detectors represent the main instruments used for primary border (customs) radiation control. RPM are widely used because they are simple, reliable, relatively inexpensive and have a high sensitivity. However, experience using the RPM in various countries has revealed the systems have some grave shortcomings. There is a dramatic decrease of the probability of detection of radioactive sources under high suppression of the natural gamma background (radiation control of heavy cargoes, containers and, especially, trains). NORM (Naturally Occurring Radioactive Material) existing in objects under control trigger the so-called 'nuisance alarms', requiring a secondary inspection for source verification. At a number of sites, the rate of such alarms is so high it significantly complicates the work of customs and border officers. This paper presents a brief description of new variant of algorithm ASIA-New (New Advanced Source Identification Algorithm), which was developed by the authors and based on some experimental test results. It also demonstrates results of different tests and the capability of a new system to overcome the shortcomings stated above. New electronics and ASIA-New enables RPM to detect radioactive sources under a high background suppression (tested at 15-30%) and to verify the detected NORM (KCl) and the artificial isotopes (Co-57, Ba-133 and other). New variant of ASIA is based on physical principles and does not require a lot of special tests to attain statistical data for its parameters. That is why this system can be easily installed into any RPM with plastic detectors. This algorithm was tested for 1,395 passages of different transports (cars, trucks and trailers) without radioactive sources. It also was tested for 4,015 passages of these transports with radioactive sources of different activity (Co-57, Ba-133, Cs-137, Co-60, Ra-226, Th-232) and these sources masked by NORM (K-40) as well. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Radiation Source Localization

Locating illicit radiological sources using gamma ray or neutron detection is a key challenge for both homeland security and nuclear nonproliferation. Localization methods using an array of detectors or a sequence of observations in time and space must provide rapid results while accounting for a dynamic attenuating environment. In the presence of significant attenuation and scatter, more extensive numerical transport calculations in place of the standard analytical approximations may be required to achieve accurate results. Numerical adjoints based on deterministic transport codes provide relatively efficient detector response calculations needed to determine the most likely location of a true source. Probabilistic representations account for uncertainty in the source location resulting from uncertainties in detector responses, the approximations that are used, and the potential for nonunique solutions. A Bayesian approach improves on previous likelihood methods for source localization by allowing the incorporation of all available information to help constrain solutions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Status of RENO Experiment

The RENO (Reactor Experiment for Neutrino Oscillation) experiment is under construction to measure the smallest neutrino mixing angle {theta}{sub 13} using anti-neutrinos emitted from the Yonggwang nuclear power plant in Korea. The experiment is planning to start data-taking in early 2011 with two identical 16-ton Gadolinium loaded liquid scintillator detectors located near and far from the center of the reactor array. The estimated systematic uncertainty associated with the measurement is less than 0.6%. Based on three years of data, the expected statistical error is about 0.3% and it would be sensitive to measure the neutrino mixing angle in the range, sin{sup 2}(2{theta}{sub 13})> 0.02. In this talk, the overview and status of RENO experiment are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTION, LOCALIZATION, AND CHARACTERIZATION OF GRAVITATIONAL WAVE BURSTS IN A PULSAR TIMING ARRAY

Efforts to detect gravitational waves by timing an array of pulsars have traditionally focused on stationary gravitational waves, e.g., stochastic or periodic signals. Gravitational wave bursts-signals whose duration is much shorter than the observation period-will also arise in the pulsar timing array waveband. Sources that give rise to detectable bursts include the formation or coalescence of supermassive black holes (SMBHs), the periapsis passage of compact objects in highly elliptic or unbound orbits about an SMBH, or cusps on cosmic strings. Here, we describe how pulsar timing array data may be analyzed to detect and characterize these bursts. Our analysis addresses, in a mutually consistent manner, a hierarchy of three questions. (1) What are the odds that a data set includes the signal from a gravitational wave burst? (2) Assuming the presence of a burst, what is the direction to its source? (3) Assuming the burst propagation direction, what is the burst waveform's time dependence in each of its polarization states? Applying our analysis to synthetic data sets, we find that we can detect gravitational waves even when the radiation is too weak to either localize the source or infer the waveform, and detect and localize sources even when the radiation amplitude is too weak to permit the waveform to be determined. While the context of our discussion is gravitational wave detection via pulsar timing arrays, the analysis itself is directly applicable to gravitational wave detection using either ground- or space-based detector data.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiant Temperature Nulling Radiometer

A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

Robert Ryan↗