Search NASA⌕ Search

SEARCH · Search NASA

Results for “random sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Twitter Stream Archiver

The Twitter Archiver system allows a user to enter their Twitter developer account credentials (obtained separately from the Twitter developer website) and read from the freely available Twitter sample stream. The Twitter sample stream provides a random sample of the overall volume of tweets that are contributed by users to the system. The Twitter Archiver system consumes the stream and serializes the information to text files at some predefined interval. A separate utility reads the text files and creates a searchable index using the open source Apache Lucene text indexing system.

Steed, Chad Allen↗

Determinants of debit cards acceptance: An empirical investigation

These days, most of the Malaysians realize that the consumption of debit card will help them to reduce the household debt. Thus, it is important to analyse the acceptance of debit cards for further enhancement and expanding its market share in Malaysia. In addition, there is lacked of research being conducted on the determinants affecting the acceptance of debit cards among Malaysians. Thus, the study aimed to investigate the factors affecting the acceptance of debit cards. This study focuses on payment methods, consumer attitude, and safety of debit card in acceptance of debit cards. Questionnaires were distributed to the 300 respondents. The sampling procedure adopted was stratified random sampling. The data obtained were analysed using SPSS 20.0 which involves scale reliability, descriptive and regression analysis. The result indicates that payment methods, consumer attitude and safety are the determinants of debit cards acceptance. Safety is the best predictor as most of the customers are confidents to use debit cards because of the security being developed around these debit card transactions. The analyses presented in this study can be used by policymakers and managers as a guide to promote banking products and services. The findings achieved in this study will be of interest for practitioners and academics concerned with developments of the Malaysian banking industry.

99 GENERAL AND MISCELLANEOUS↗

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accumulation of Pb and Cu heavy metals in sea water, sediment, and leaf and root tissue of Enhalus sp. in the seagrass bed of Banten Bay

Banten Bay in Indonesia is a coastal area which has been highly affected by human activity. Previous studies have reported the presence of lead (Pb) and copper (Cu) heavy metals in the seawater of this area. This study was conducted to measure the accumulation of Pb and Cu in seawater, sediment, leaf tissue, and root tissue of the seagrass species Enhalus sp. Sampling was conducted at two observation stations in Banten Bay: Station 1 (St.1) was located closer to the coastline and to industrial plants as source of pollution, while Station 2 (St.2) was located farther away offshore. At each station, three sampling points were established by random sampling. Field sampling was conducted at two different dates, i.e., on 29 May 2012 and 30 June 2012. Samples were processed by wet ashing using concentrated HNO{sub 3} acid and measured using Atomic Absorption Spectrometry (AAS). Accumulation of Pb was only detected in sediment samples in St.1, while Cu was detected in all samples. Average concentrations of Cu in May were as follows: sediment St.1 = 0.731 ppm, sediment St.2 = 0.383 ppm, seawater St.1 = 0.163 ppm, seawater St.2 = 0.174 ppm, leaf St.1 = 0.102 ppm, leaf St.2 = 0.132 ppm, root St.1= 0.139 ppm, and root St.2 = 0.075 ppm. Average measurements of Cu in June were: sediment St.1 = 0.260 ppm, leaf St.1 = 0.335 ppm, leaf St.2 = 0.301 ppm, root St.1= 0.047 ppm, and root St.2 = 0.060 ppm. In June, Cu was undetected in St.2 sediment and seawater at both stations. In May, Cu concentration in seawater exceeded the maximum allowable threshold for water as determined by the Ministry of the Environment. Spatial and temporal variation in Pb and Cu accumulation were most probably affected by distance from source and physical conditions of the environment (e.g., water current and mixing)

54 ENVIRONMENTAL SCIENCES↗

The Radiation Unit is Difficult for the General Public to Understand - An Easier Alternative Unit is Required - 17223

One of the difficult things to explain about nuclear power and/or radiation to the public is the 'radiation unit'. Especially after the Fukushima accident, many people are concerned about radiation, but over 70% of public who responded to the survey do not understand what the Bq (Becquerel) refers to. Changing the SI unit (International System of Units) is not easy, and instead, auxiliary units can be used. We considered several auxiliary units: one using an index number (like that for earthquakes), one that makes a comparison to general drug risk, one that makes a comparison to an amount of foodstuff (like BED), an introducing index comparing annual dose limit, using number compared to the background, and colorizing (i.e, red, green, blue). KHNP-CRI surveyed the public about radiation and radiation unit indexes to determine which was easiest to understand. For the question 'Do you know what the radiation unit Becquerel (Bq) is?', over 70% answered 'No'. When asked,'Do you think radioactivity is contagious and can be transmitted through a person's respiratory system or via skin contact?', over 47% answered 'It is definitely or possibly contagious'. When asked, 'Which would you prefer as an easier to understand radiation auxiliary unit, if it were to be changed?', over 70% preferred 'colorizing or figure'. It is interesting that men prefer figures whereas women prefer colorizing. The sample population of the survey was 500 adult men and women in Korea. The sampling error was based on random sampling, a confidence interval of 95%, and a standard maximum allowable sampling error of ± 4.4% point. The survey method was 'Computer Aided Telephone Interview' (CATI). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computing the partition function, ensemble averages, and density of states for lattice spin systems by sampling the mean

An algorithm to approximately calculate the partition function (and subsequently ensemble averages) and density of states of lattice spin systems through non-Monte-Carlo random sampling is developed. This algorithm (called the sampling-the-mean algorithm) can be applied to models where the up or down spins at lattice nodes interact to change the spin states of other lattice nodes, especially non-Ising-like models with long-range interactions such as the biological model considered here. Because it is based on the Central Limit Theorem of probability, the sampling-the-mean algorithm also gives estimates of the error in the partition function, ensemble averages, and density of states. Easily implemented parallelization strategies and error minimizing sampling strategies are discussed. The sampling-the-mean method works especially well for relatively small systems, systems with a density of energy states that contains sharp spikes or oscillations, or systems with little a priori knowledge of the density of states.

97 MATHEMATICS AND COMPUTING↗

How to estimate soil organic carbon stocks of agricultural fields? perspectives using ex-ante evaluation

Estimating soil organic carbon (SOC) stocks of agricultural fields has a range of important applications from development of sustainable management practices to monitoring carbon stocks. There are many estimation strategies with the potential for more reliable estimates of SOC stock and more efficient use of soil sampling and analysis resources, especially by leveraging readily available auxiliary information such as remote sensing. However, concrete guidance for strategy selection is lacking. This study narrows this gap with a comparison of strategies for estimating deep SOC stock (0–60 cm) in a prototypical field. Using high density SOC stock measurements and simulation, we built on past studies by 1) ex-ante evaluating a large number of strategy options, 2) using a Bayesian approach to quantify the uncertainty of the comparison, and 3) considering multiple Bayesian models to assess sensitivity to this modeling choice. We found that, using readily available auxiliary information, both balanced and stratified sampling offer substantial improvements over simple random sampling. The auxiliary information most important for this improvement is a Sentinel-2 SOC index = blue / (green × red), followed by the topographic wetness index. We found that these results are robust to the choice of mapping method, but that there is uncertainty in the magnitude of improvement. Here, we recommend future studies implement this Bayesian approach for simulated ex-ante evaluation of SOC stock estimation strategies across more fields to investigate the generalizability of these findings.

54 ENVIRONMENTAL SCIENCES↗

Effects of sample design and landscape features on a measure of environmental heterogeneity

Environmental heterogeneity, an important influence on organisms and ecological processes, can be quantified by the variance of an environmental characteristic over all locations within a study extent. However on landscapes with autocorrelation and gradient patterns, estimating this variance from a sample of locations may lead to errors that cannot be corrected with statistical techniques. We analytically derived the relative expected sampling error of sample designs on landscapes with particular gradient pattern and autocorrelation features. We applied this closed-form approach to temperature observations from an existing study. The expected heterogeneity differed, both in magnitude and direction, amongst sample designs over the study site's likely range of autocorrelation and gradient features. We conducted a simulation study to understand the effects of (i) landscape variability and (ii) design variability on an average sampling error. On 10 000 simulated landscapes with varying gradient and autocorrelation features, we compared estimates of variance from a variety of structured and random sample designs. While gradient patterns and autocorrelation cause large errors for some designs, others yield near-zero average sampling error. Sample location spacing is a key factor in sample design performance. Random designs have larger range of possible sampling errors than structured designs due to the potential for sample arrangements that over- and under-sample certain areas of the landscape. Furthermore, when implementing a new sample design to quantify environmental heterogeneity via variance, we recommend using a simple structured design with appropriate sample spacing. For existing designs, we recommend calculating the relative expected sampling error via our analytical derivation.

54 ENVIRONMENTAL SCIENCES↗

In-service Inspection of Radioactive Waste Tanks at the Savannah River Site – 15410

Liquid radioactive wastes from the Savannah River Site (SRS) separation process are stored in large underground carbon steel tanks. The high level wastes are processed in several of the tanks and then transferred by piping to other site facilities for further processing before they are stabilized in a vitrified or grout waste form. Based on waste removal and processing schedules, many of the tanks will be required to be in service for times exceeding the initial intended life. Until the waste is removed from storage, transferred, and processed, the materials and structures of the tanks must maintain a confinement function by providing a barrier to the environment and by maintaining acceptable structural stability during design basis events, which include loadings from both normal service and abnormal (e.g., earthquake) conditions. A structural integrity program is in place to maintain the structural and leak integrity functions of these waste tanks throughout their intended service life. In-service inspection (ISI) is an essential element of a comprehensive structural integrity program for the waste tanks at the Savannah River Site (SRS). The ISI program was developed to determine the degree of degradation the waste tanks have experienced due to service conditions. As a result of the inspections, an assessment can be made of the effectiveness of corrosion controls for the waste chemistry, which precludes accelerated localized and general corrosion of the waste tanks. Ultrasonic inspections (UT) are performed to detect and quantify the degree of general wall thinning, pitting and cracking as a measure of tank degradation. The results from these inspections through 2013, for the 27 Type III/IIIA tanks, indicate no reportable in-service corrosion degradation in the primary tank (i.e., general, pitting, or cracking). The average wall thickness for all tanks remains above the manufactured nominal thickness minus 0.25 millimeter and the largest pit identified is approximately 1.70 millimeter deep (i.e., less than 10% through-wall). Improvements to the inspection program were recently instituted to provide additional confidence in the degradation rates. Thickness measurements from a single vertical strip along the accessible height of the primary tank have been used as a baseline to compare historical measurements. Changes in wall thickness and pit depths along this vertical strip are utilized to estimate the rate of corrosion degradation. An independent review of the ISI program methodology, results, and path forward was held in August 2009. The review recommended statistical sampling of the tanks to improve the confidence of the single strip inspection program. The statistical sampling plan required that SRS increase the amount of area scanned per tank. Therefore, in addition to the baseline vertical strip that is obtained for historical comparisons, four additional randomly selected vertical strips are inspected. To date, a total of 104 independent vertical strips along the height of the primary tank have been completed. A statistical analysis of the data indicates that at this coverage level there is a 99.5% confidence level that one of the worst 5% of all the vertical strips was inspected. That is, there is a relatively high likelihood that the SRS inspection program has covered one of the most corroded areas of any of the Type III/IIIA waste tanks. These data further support the conclusion that there are no significant indications of wall thinning or pitting. Random sampling will continue to increase the confidence that one of the worst 5% has been inspected. In order to obtain the additional vertical strips, and minimize budget and schedule impacts, data collection speed for the UT system was optimized. Prior to 2009, the system collected data at a rate of 32 square centimeters per minute. The scan rate was increased to 129 - 160 square centimeters per minute by increasing the scanner step and pixel sizes in the data acquisition set-up. Laboratory testing was utilized to optimize the scan index/pixel size such that the requirements for wall thinning and pit detection were still maintained. SRS continues to evaluate improvements to ultrasonic equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reweighted ℓ{sub 1} minimization method for stochastic elliptic differential equations

We consider elliptic stochastic partial differential equations (SPDEs) with random coefficients and solve them by expanding the solution using generalized polynomial chaos (gPC). Under some mild conditions on the coefficients, the solution is “sparse” in the random space, i.e., only a small number of gPC basis makes considerable contribution to the solution. To exploit this sparsity, we employ reweighted l{sub 1} minimization to recover the coefficients of the gPC expansion. We also combine this method with random sampling points based on the Chebyshev probability measure to further increase the accuracy of the recovery of the gPC coefficients. We first present a one-dimensional test to demonstrate the main idea, and then we consider 14 and 40 dimensional elliptic SPDEs to demonstrate the significant improvement of this method over the standard l{sub 1} minimization method. For moderately high dimensional (∼10) problems, the combination of Chebyshev measure with reweighted l{sub 1} minimization performs well while for higher dimensional problems, reweighted l{sub 1} only is sufficient. The proposed approach is especially suitable for problems for which the deterministic solver is very expensive since it reuses the sampling results and exploits all the information available from limited sources.

97 MATHEMATICS AND COMPUTING↗

Research Technology Laboratory (RTL) Disposition Program Final Status Survey Report

As part of the Battelle Facility Restoration Program (Smoter and Biebesheimer 2017), the Research Technology Laboratory (RTL) Complex was remediated through demolition and surveyed to show it meets the radiological release criteria for unrestricted use under the clearance process (DOE 2011). The restoration program has directed the implementation of the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) methodology (NRC 2011) to verify the suitability of the site to be released for unrestricted use under the clearance process in U.S. Department of Energy (DOE) Order 458.1 (Biebesheimer 2018a; DOE 2011). The use of MARSSIM is accepted by federal and state agencies, including DOE. This report documents how the MARSSIM process was used to assure any residual radioactivity is within acceptable levels and as low as reasonably achievable. Past land use for the RTL Complex property included agricultural, residential, and industrial activity. The historical site assessment (HSA) (Lindenmeier et al. 2015; Biebesheimer 2018b) identified use of radionuclides in past RTL Complex research and development activities from commissioning in 1966 until it was vacated in 2017. Based on the information provided in the HSA, the RTL Complex was delineated into six survey units. The 520 building footprint, tank vault and 530 building footprint, other building footprints, and pipeline survey units included excavated areas. The paved areas and open areas survey units were unexcavated areas. Survey units were all determined to be Class 3, with low probability of containing residual radioactivity, after demolition of the structures within the RTL Complex. The Research Technology Laboratory (RTL) Disposition Program: Final Status Survey Plan (Bunn et al. 2018) was designed and conducted to provide quantitative data regarding the residual radioactivity present in each survey unit. Authorized radiological release limits were developed and approved by the DOE Office of Science in December 2016 (DOE 2017). Fourteen random sample locations were identified within each survey unit. Forty-four specific judgmental sample locations were selected across the site based on information in the HSA. The number of sample locations within a survey unit ranged from 15 to 28, for a total of 127 random and judgmental sample locations identified across the RTL Complex. Sampling for the final status survey occurred over 12 days between November 11 and December 7, 2018. Laboratory results were independently validated by Analytical Quality Associates prior to evaluation. All of the over 880 residual radioactivity measurements were less than the release limits and action levels established through the RTL Disposition Program. A sum of fractions calculation for each survey unit resulted in values that were less than unity. Based on the results presented in this report, the restoration program recommends that the RTL Complex be released for unrestricted use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deterministic Linear Time for Maximal Poisson‐Disk Sampling using Chocks without Rejection or Approximation

Abstract We show how to sample uniformly within the three‐sided region bounded by a circle, a radial ray, and a tangent, called a “chock.” By dividing a 2D planar rectangle into a background grid, and subtracting Poisson disks from grid squares, we are able to represent the available region for samples exactly using triangles and chocks. Uniform random samples are generated from chock areas precisely without rejection sampling. This provides the first implemented algorithm for precise maximal Poisson‐disk sampling in deterministic linear time. We prove O(n · M(b) log b), where n is the number of samples, b is the bits of numerical precision and M is the cost of multiplication. Prior methods have higher time complexity, take expected time, are non‐maximal, and/or are not Poisson‐disk distributions in the most precise mathematical sense. We fill this theoretical lacuna.

Mitchell, Scott A.↗

Hyporheic, Floodplain, and Surface Water (on Floodplain and River) Geochemical Datasets, and Shapefiles on Meander C at the East River, Colorado

The purpose of this dataset was to sample surface water and groundwater geochemistry at random locations in the East River, Colorado to provide a broad spatial dataset of geochemistry. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. We conducted this random sampling at multiple time points including during the snowmelt flooding stage, during peak flood, during the falling limb of flood, and during baseflow. This datasets contain many datafiles. We include flat text files of surface water geochemistry including surface water on the floodplain and surface water in the river, geochemistry of floodplain pore-water samples, and geochemistry of hyporheic pore-water samples. All datasets are also included as shapefiles so location geochemistry is co-located with sampling locations and sampling depths. This datasets also has the locations of small channels, and hollows that are on top of floodplain Meander C. These small channels funnel surface water from the hillslope through the floodplain and out to the river. All text datasets can be analyzed with software such as Excel or R. All shapefiles can be viewed with freely available R packages such as Leaflet.

54 ENVIRONMENTAL SCIENCES↗

Sampling Plan for Measuring Dark Current in Model 8825 Whole Body Dosimeters Used at Sandia National Laboratories

Dark current is the measured response of dosimeters when they have been exposed to no radiation. A sampling plan was developed for measuring the average dark current associated with processing the Thermo Model 8825 whole body dosimeters currently used at Sandia National Laboratories. The dosimeters each consist of an array of 4 thermoluminescent dosimeter (TLD) chips. The population of dosimeters was found to consist of 2 strata: older and newer dosimeters. Results from some recently processed dosimeters were used to estimate the variability in response of the TLD chips of the newer and older dosimeters in the active population. The older dosimeters have more variability than the newer dosimeters across all the 4 TLD chips. TLD chip 3, which measures shallow dose, has the most variability of all the TLD chips. The sampling plan developed is based on stratified random sampling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Convergence Study in Global Sensitivity Analysis

Monte Carlo (MC) sampling is a common method used to randomly sample a range of scenarios. The associated error follows a predictable rate of convergence of $1/\sqrt{N}$, such that quadrupling the sample size halves the error. This method is often employed in performing global sensitivity analysis which computes sensitivity indices, measuring fractional contributions of uncertain model inputs to the total output variance. In this study, several models are used to observe the rate of decay in the MC error in the estimation of the conditional variance, the total variance in the output, and the global sensitivity indices. The purpose is to examine the rate of convergence of the error in existing specialized, albeit MC-based, sampling methods for estimation of the sensitivity indices. It was found that the conditional variances and sensitivity indices all follow the $1/\sqrt{N}$ convergence rate. Future work will test the convergence of observables from more complex models such as ignition time in combustion.

97 MATHEMATICS AND COMPUTING↗

Application of GRS method to evaluation of uncertainties of calculation parameters of perspective sodium-cooled fast reactor

A number of recent studies have been devoted to the estimation of errors of reactor calculation parameters by the GRS (Generation Random Sampled) method. This method is based on direct sampling input data resulting in formation of random sets of input parameters which are used for multiple calculations. Once these calculations are performed, statistical processing of the calculation results is carried out to determine the mean value and the variance of each calculation parameter of interest. In our study this method is used for estimation of errors of calculation parameters (K{sub eff}, power density, dose rate) of a perspective sodium-cooled fast reactor. Neutron transport calculations were performed by the nodal diffusion code TRIGEX and Monte Carlo code MMK. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗