Search NASA⌕ Search

SEARCH · Search NASA

Results for “ray path geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

2D kinetic-ion simulations of inverted corona fusion targets

Laser-driven “inverted corona” fusion targets have attracted interest as a low-convergence neutron source and platform for studying kinetic physics. The scheme consists of a hollow or gas-filled spherical shell made of deuterated plastic. The shell has one or more laser entrance holes (LEH), resembling a spherical hohlraum. The laser passes through the LEH’s and illuminates the interior surface of the shell, ablating a plasma that travels inward towards the target center. Long ion mean free paths in the converging plasma can lead to significant interpenetration, atomic mix, and other kinetic effects. Here, in this work we report on numerical simulations of inverted corona targets using the kinetic-ion, fluid–electron hybrid particle-in-cell (PIC) approach in 2D RZ geometry. 2D simulations suggest that shape effects do not have a significant impact on plasma evolution and observed yield trends are primarily the result of 1D kinetic mix mechanisms. Simulations are also compared against available experimental data recorded at the OMEGA laser facility. In particular, synthetic x-ray emission images show good qualitative agreement with experimental results, albeit with an apparent timing discrepancy for the two-sided vacuum target. More generally, we demonstrate the potential of hybrid-PIC simulations for full-system modeling and experimental design, including collisional absorption of laser energy, plasma evolution, mix, and fusion burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Modeling of a Dual-Stage Sodium Thermal-Electrochemical Converter (Na-TEC)

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity through the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (550 K – 950 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management through a reduction of parasitic losses. These losses are comprised of (i) the heat input that does not participate in power production but simply bypasses the thermo-electrochemical process and is transferred to the condenser, and (ii) heat that is lost from the device directly to the surroundings due to poor insulation. Heat loss to the surroundings occurs from a lower average hot-side temperature given that a fraction of the power conversion occurs at an intermediate stage. Also, the condenser now directly interacts with the lower temperature of the intermediate stage, thereby reducing radiation loss. A simplified geometry is developed for this device to help guide its design from a heat transfer perspective. All thermal contact and boundary conditions are discussed, including the evaporation and condensation of sodium vapor, thermal leakage through the housing, and the thermal contact between the beta”-alumina and the housing. A ray tracing method assuming gray, diffuse surfaces is used to account for the internal radiation heat transfer within the device. Liquid sodium flows in a capillary wick between the condenser and the evaporator with Pe << 1, so only conduction heat transfer is considered within this liquid return path. For simplicity, natural convection between the sodium vapor and the device housing is neglected. A numerical linear resistance model (<5% error when compared to a finite element model) is used to determine the expected conversion temperatures of each stage for a range of candidate materials. Furthermore, a numerical model (<2% error) is developed to find the factor of increase in the thermal resistance for several designs of corrugated features for the device housing. By using an iterative scheme, efficiency vs. power curves are created for a number of material and size combinations. Finally, the fundamental tradeoff between the power and efficiency is explored in conjunction with the total system size.

14 SOLAR ENERGY↗

Cyclotron Resonant Scattering Feature Simulations II. Description of the CRSF Simulation Process

Context. Cyclotron resonant scattering features (CRSFs) are formed by scattering of X-ray photons o_ quantized plasma electrons in the strong magnetic field (of the order 1012 G) close to the surface of an accreting X-ray pulsar. Due to the complex scattering cross-sections, the line profiles of CRSFs cannot be described by an analytic expression. Numerical methods, such as Monte Carlo (MC) simulations of the scattering processes, are required in order to predict precise line shapes for a given physical setup, which can be compared to observations to gain information about the underlying physics in these systems.Aims. A versatile simulation code is needed for the generation of synthetic cyclotron lines. Sophisticated geometries should be investigatable by making their simulation possible for the first time.Methods. The simulation utilizes the mean free path tables described in the first paper of this series for the fast interpolation of propagation lengths. The code is parallelized to make the very time-consuming simulations possible on convenient time scales. Furthermore, it can generate responses to monoenergetic photon injections, producing Green's functions, which can be used later to generate spectra for arbitrary continua.Results. We develop a new simulation code to generate synthetic cyclotron lines for complex scenarios, allowing for unprecedented physical interpretation of the observed data. An associated XSPEC model implementation is used to fit synthetic line profiles to NuSTAR data of Cep X-4. The code has been developed with the main goal of overcoming previous geometrical constraints in MC simulations of CRSFs. By applying this code also to more simple, classic geometries used in previous works, we furthermore address issues of code verification and cross-comparison of various models. The XSPEC model and the Green's function tables are available online (see link in footnote, page 1).

Schwarm, F.-W.↗

A Measurement of the Energy Spectra of Cosmic Rays from 20 to 1000 GeV Per Amu

The design features and operational performance from the test flight of the fourth generation of spherical geometry cosmic ray detectors developed at Bristol University (Bristol University Gas Scintillator 4 - BUGS-4) are presented. The flight from Ft. Sumner (NM) in Sept. 1993 was the premier flight of a large (1m radius) spherical drift chamber which also gave gas scintillation and Cerenkov signals. The combinations of this chamber with one gas and two solid Cerenkov radiators lead to a large aperture factor (4.5 m2sr), but low (approximately 3.5 g/sq cm) instrument mass over the energy sensitive range 1 to several hundred GeV/a. Moreover, one simple timing measurement determined the impact parameter which provided a trajectory (path length) correction for all detector elements. This innovative and efficient design will be of interest to experimental groups engaged in studies of energetic charged particles. Although there were technical problems on the flight, which were compounded by the total destruction of BUGS-4 by fire while landing in Oklahoma, there was a period of stable operation during which the instrument was exposed at float altitude (approximately 125,000 ft.) to high energy cosmic rays. We present the performance of the instrument as determined from the analysis of these data and an appraisal of its novel design features. Suggestions for design improvements in a future instrument are made.

Gregory, J. C.↗

Crosswell Seismic Amplitude-Versus-Offset for Detailed Imaging of Facies and Fluid Distribution within Carbonate Oil Reservoirs

Crosswell seismic surveys were conducted at two fields in northern Michigan. One of these, Springdale, included two monitor wells that are located external to the reef, and the other, Coldspring, employed two production wells within the reef. The Springdale wells extended to much greater depths than the reef, and imaging was conducted from above and from beneath the reef. The resulting seismic images provide the best views of pinnacle Niagaran reefs obtained to date. The tops of the reservoirs can be clearly distinguished, and their lateral extent or dipping edges can be observed along the profile. Reflecting events internal to the reef are evident; some of them are fairly continuous across the reef and others are discontinuous. Inversion of the seismic data indicates which events represent zones of higher porosity and which are lower porosity or even anhydrite plugged. The full stacked image includes angles that are beyond critical for many of the interfaces, and some reflections are visible only for a small range of angles, presumably near their critical angle. Stacking these angles in provides an opportunity for these events to be seen on the stacked image, where otherwise they would have been unrecognized. For inversion, however, the complexity associated with phase changes beyond critical can lead to poor results, and elastic inversion of partial angle stacks may be best conducted with restrictions to angles less than critical. Strong apparent attenuation of signals occurs when seismic ray paths pass through the upper part of the Springdale reservoir; this may be due to intrinsic attenuation and/or scattering of events due to the locally strongly varying gas saturation and extremely low fluid pressures. Signal-to-noise limitations become evident far from the source well in the Coldspring study, probably because the raw data were strongly affected by tube-wave noise generated by flow through the perforation of the receiver well. The seismic images obtained, and interpretations of them, as assisted by Amplitude-versus-Angle studies and accompanying inversion, provide additional insight into the internal geometry of these two reefs and provide data that should be useful for reservoir management.

02 PETROLEUM↗

Mechanisms of nickel sorption by a bacteriogenic birnessite

A synergistic experimental-computational approach was used to study the molecular-scale mechanisms of Ni sorption at varying loadings and at pH 6-8 on the biogenic hexagonal birnessite produced by Pseudomonas putida GB-1. We found that Ni is scavenged effectively by bacterial biomass-birnessite assemblages. At surface excess values below 0.18 mol Ni kg{sup -1} sorbent (0.13 mol Ni mol{sup -1} Mn), the biomass component of the sorbent did not interfere with Ni sorption on mineral sites. Extended X-ray absorption fine structure (EXAFS) spectra showed two dominant coordination environments: Ni bound as a triple-corner-sharing (Ni-TCS) complex at vacancy sites and Ni incorporated (Ni-inc) into the MnO{sub 2} sheet, with the latter form of Ni favored at high sorptive concentrations and decreased proton activity. In parallel to our spectral analysis, first-principles geometry optimizations based on density functional theory (DFT) were performed to investigate the structure of Ni surface complexes at vacancy sites. Excellent agreement was achieved between EXAFS- and DFT-derived structural parameters for Ni-TCS and Ni-inc. Reaction-path calculations revealed a pH-dependent energy barrier associated with the transition from Ni-TCS to Ni-inc. Our results are consistent with the rate-limited incorporation of Ni at vacancy sites in our sorption samples, but near-equilibrium state of Ni in birnessite phases found in nodule samples. This study thus provides direct and quantitative evidence of the factors governing the occurrence of Ni adsorption versus Ni incorporation in biogenic hexagonal birnessite, a key mineral in the terrestrial manganese cycle.

54 ENVIRONMENTAL SCIENCES↗

Wedge-and-strip anodes for centroid-finding position-sensitive photon and particle detectors

The paper examines geometries employing position-dependent charge partitioning to obtain a two-dimensional position signal from each detected photon or particle. Requiring three or four anode electrodes and signal paths, images have little distortion and resolution is not limited by thermal noise. An analysis of the geometrical image nonlinearity between event centroid location and the charge partition ratios is presented. In addition, fabrication and testing of two wedge-and-strip anode systems are discussed. Images obtained with EUV radiation and microchannel plates verify the predicted performance, with further resolution improvements achieved by adopting low noise signal circuitry. Also discussed are the designs of practical X-ray, EUV, and charged particle image systems.

Martin, C.↗

A Unified Model of Cosmic-Ray Propagation and Radio Extreme Scattering Events from Intermittent Interstellar Structures

Intermittent magnetic structures are a plausible candidate for explaining cosmic-ray (CR) diffusion rates derived from observed CR energy spectra. Independently, studies of extreme scattering events (ESEs) of radio quasars and pulsar scintillation have hinted that very straight, large aspect ratio magnetic current sheets may be responsible for the localized large scattering of radio waves. The required shortest axis of the typical structures producing ESEs is of the same scale (∼au) as the gyroradii of ∼GeV CRs. In this Letter, we propose that the same magnetic/density sheets can produce large scattering of both CRs and radio waves. We demonstrate that the geometry and volume-filling factor of the sheets derived from quasar ESEs can explain the observed mean free path of GeV CRs without introducing free parameters. The model places constraints on the sheet geometry, such as straightness and large aspect ratio, and assumes that the statistics of the sheets are similar throughout the Galactic volume. We therefore discuss observational tests of the sheet model, which includes observations of echoes in pulsars and fast radio bursts, gravitationally lensed quasars, the distribution of ESE durations, and spatial correlations between ESE events and rotation measure fluctuations. Such tests will be enabled by upcoming wide-field radio instruments, including the Canadian Hydrogen Observatory and Radio-transient Detector and Deep Synoptic Array 2000 Antennas.

Kempski, Philipp [Princeton Univ., NJ (United Stat↗

Experimental evaluations of the accuracy of 3D and 4D planning in robotic tracking stereotactic body radiotherapy for lung cancers

Purpose: Due to the complexity of 4D target tracking radiotherapy, the accuracy of this treatment strategy should be experimentally validated against established standard 3D technique. This work compared the accuracy of 3D and 4D dose calculations in respiration tracking stereotactic body radiotherapy (SBRT). Methods: Using the 4D planning module of the CyberKnife treatment planning system, treatment plans for a moving target and a static off-target cord structure were created on different four-dimensional computed tomography (4D-CT) datasets of a thorax phantom moving in different ranges. The 4D planning system used B-splines deformable image registrations (DIR) to accumulate dose distributions calculated on different breathing geometries, each corresponding to a static 3D-CT image of the 4D-CT dataset, onto a reference image to compose a 4D dose distribution. For each motion, 4D optimization was performed to generate a 4D treatment plan of the moving target. For comparison with standard 3D planning, each 4D plan was copied to the reference end-exhale images and a standard 3D dose calculation was followed. Treatment plans of the off-target structure were first obtained by standard 3D optimization on the end-exhale images. Subsequently, they were applied to recalculate the 4D dose distributions using DIRs. All dose distributions that were initially obtained using the ray-tracing algorithm with equivalent path-length heterogeneity correction (3D{sub EPL} and 4D{sub EPL}) were recalculated by a Monte Carlo algorithm (3D{sub MC} and 4D{sub MC}) to further investigate the effects of dose calculation algorithms. The calculated 3D{sub EPL}, 3D{sub MC}, 4D{sub EPL}, and 4D{sub MC} dose distributions were compared to measurements by Gafchromic EBT2 films in the axial and coronal planes of the moving target object, and the coronal plane for the static off-target object based on the {gamma} metric at 5%/3mm criteria ({gamma}{sub 5%/3mm}). Treatment plans were considered acceptable if the percentage of pixels passing {gamma}{sub 5%/3mm} (P{sub {gamma}<1}) {>=} 90%. Results: The averaged P{sub {gamma}<1} values of the 3D{sub EPL}, 3D{sub MC}, 4D{sub EPL}, and 4D{sub MC} dose calculation methods for the moving target plans are 95%, 95%, 94%, and 95% for reproducible motion, and 95%, 96%, 94%, and 93% for nonreproducible motion during actual treatment delivery. The overall measured target dose distributions are in better agreement with the 3D{sub MC} dose distributions than the 4D{sub MC} dose distributions. Conversely, measured dose distributions agree much better with the 4D{sub EPL/MC} than the 3D{sub EPL/MC} dose distributions in the static off-target structure, resulting in higher P{sub {gamma}<1} values with 4D{sub EPL/MC} (91%) vs 3D{sub EPL} (24%) and 3D{sub MC} (25%). Systematic changes of target motion reduced the averaged P{sub {gamma}<1} to 47% and 53% for 4D{sub EPL} and 4D{sub MC} dose calculations, and 22% for 3D{sub EPL/MC} dose calculations in the off-target films. Conclusions: In robotic tracking SBRT, 4D treatment planning was found to yield better prediction of the dose distributions in the off-target structure, but not necessarily in the moving target, compared to standard 3D treatment planning, for reproducible and nonreproducible target motion. It is important to ensure on a patient-by-patient basis that the cumulative uncertainty associated with the 4D-CT artifacts, deformable image registration, and motion variability is significantly smaller than the cumulative uncertainty occurred in standard 3D planning in order to make 4D planning a justified option.

60 APPLIED LIFE SCIENCES↗

Toroidal plasma enhanced CVD of diamond films

An inductively coupled toroidal plasma source is used as an alternative to microwave plasmas for chemical vapor deposition of diamond films. The source, operating at a frequency of 400 kHz, synthesizes diamond films from a mixture of argon, methane, and hydrogen. The toroidal design has been adapted to create a highly efficient environment for diamond film deposition: high gas temperature and a short distance from the sample to the plasma core. Using a toroidal plasma geometry operating in the medium frequency band allows for efficient (≈90%) coupling of AC line power to the plasma and a scalable path to high-power and large-area operation. In test runs, the source generates a high flux of atomic hydrogen over a large area, which is favorable for diamond film growth. Using a deposition temperature of 900–1050 °C and a source to sample distance of 0.1–2.0 cm, diamond films are deposited onto silicon substrates. The results showed that the deposition rate of the diamond films could be controlled using the sample temperature and source to sample spacing. The results also show the films exhibit good-quality polycrystalline diamond as verified by Raman spectroscopy, x-ray diffraction, and scanning electron microscopy. The scanning electron microscopy and x-ray diffraction results show that the samples exhibit diamond (111) and diamond (022) crystallites. The Raman results show that the sp{sup 3} peak has a narrow spectral width (FWHM 12 ± 0.5 cm{sup −1}) and that negligible amounts of the sp{sup 2} band are present, indicating good-quality diamond films.

36 MATERIALS SCIENCE↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Enrichment Determination of Uranium in Shielded Configurations

The determination of the enrichment of uranium is required in many safeguards and security applications. Typical methods of determining the enrichment rely on detecting the 186 keV gamma ray emitted by 235 U. In some applications, the uranium is surrounded by external shields, and removal of the shields is undesirable. In these situations, methods relying on the detection of the 186 keV gamma fail because the gamma ray is shielded easily. Oak Ridge National Laboratory (ORNL) has previously measured the enrichment of shielded uranium metal using active neutron interrogation. The method consists of measuring the time distribution of fast neutrons from induced fissions with large plastic scintillator detectors. To determine the enrichment, the measurements are compared to a calibration surface that is created from Monte Carlo simulations where the enrichment in the models is varied. In previous measurements, the geometry was always known. ORNL is extending this method to situations where the geometry and materials present are not known in advance. In the new method, the interrogating neutrons are both time and directionally tagged, and an array of small plastic scintillators measures the uncollided interrogating neutrons. Therefore, the attenuation through the item along many different paths is known. By applying image reconstruction techniques, an image of the item is created which shows the position-dependent attenuation. The image permits estimating the geometry and materials present, and these estimates are used as input for the Monte Carlo simulations. As before, simulations predict the time distribution of induced fission neutrons for different enrichments. Matching the measured time distribution to the closest prediction from the simulations provides an estimate of the enrichment. This presentation discusses the method and provides results from recent simulations that show the importance of knowing the geometry and materials from the imaging system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark stars: Implications and constraints from cosmic reionization and extragalactic background radiation

Dark stars powered by dark matter annihilation have been proposed as the first luminous sources in the Universe. These stars are believed to form in the central dark matter cusp of low-mass minihalos. Recent calculations indicate stellar masses up to {approx}1000M{sub {center_dot}} and/or have very long lifetimes. The UV photons from these objects could therefore contribute significantly to cosmic reionization. Here we show that such dark star models would require a somewhat artificial reionization history, based on a double-reionization phase and a late star burst near redshift z{approx}6, in order to fulfill the WMAP (Wilkinson Microwave Anisotropy Probe) constraint on the optical depth as well as the Gunn-Peterson constraint at z{approx}6. This suggests that, if dark stars were common in the early universe, then models are preferred which predict a number of UV photons similar to conventional Pop. III stars. This excludes 800M{sub {center_dot}} dark stars that enter a main-sequence phase and other models that lead to a strong increase in the number of UV photons. We also derive constraints for massive as well as light dark matter candidates from the observed x-ray, gamma-ray, and neutrino background, considering dark matter profiles which have been steepened during the formation of dark stars. This increases the clumping factor at high redshift and gives rise to a higher dark matter annihilation rate in the early universe. We furthermore estimate the potential contribution from the annihilation products in the remnants of dark stars, which may provide a promising path to constrain such models further, but which is currently still uncertain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time and space resolved measurement of the electron temperature, mass density and ionization state in the ablation plasma between two exploding Al wires

We have determined the properties of plasma around and between two exploding wires using high-resolution x-ray absorption spectroscopy. Plasma densities and temperatures ranging from Greater-Than-Or-Equivalent-To 0.1g/cm{sup 3} and a few eV to less than 0.01 g/cm{sup 3} and 30 eV have been measured in experiments at Cornell University with two 40 {mu}m aluminum (Al) wires spaced 1 mm apart driven by {approx}150 kA peak current pulses with 100 ns rise time. The wire plasma was backlit by the 1.4-1.6 keV continuum radiation produced by a Mo wire X-pinch. The spectrometer employed two spherically bent quartz crystals to record the absorption and backlighter spectra simultaneously. The transition between the dense Al wire core and the coronal plasma is seen as a transition from cold K-edge absorption to Mg-, Na-, and finally Ne-like absorption at the boundary. In the plasma that accumulates between the wires, ionization states up to C-Like Al are observed. The spectrometer geometry and {approx}2{mu}m X-pinch source size provide 0.3 eV spectral resolution and 20 {mu}m spatial resolution enabling us to see 1s{yields} 2p satellite transitions as separate lines as well as O-, F-, and Ne-like 1s{yields} 3p transitions that have not been seen before. A step wedge was used to calibrate the transmission, enabling density to be measured within a factor of two and temperature to be measured within {+-}25%. A genetic algorithm was developed to fit synthetic spectra calculated using the collisional-radiative code SCRAM to the experimental spectra. In order to obtain agreement it was necessary to assume multiple plasma regions with variable thicknesses, thereby allowing the inferred plasma conditions to vary along the absorption path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-543: Measurement of Neutron Activation From Different High Energy Varian Linear Accelerators

Purpose: Linear accelerators producing photons above 10 MeV may induce photonuclear reactions in high Z components of the accelerator. These liberated neutrons can then activate the structural components of the accelerator and other materials in the beam path through neutron capture reactions. The induced activity within the accelerator may contribute to additional dose to both patients and personnel. This project seeks to determine the total activity and activity per activated isotope following irradiation in different Varian accelerators at energies above 10 MeV. Methods: A Varian 21IX accelerator was used to irradiate a 30 cm × 30 cm × 20 cm solid water phantom with 15 MV x-rays. The phantom was placed at an SSD of 100 cm and at the center of a 20 cm × 20 cm field. Activation induced gamma spectra were acquired over a 5 minute interval after 1 and 15 minutes from completion of the irradiation. All measurements were made using a CANBERRA Falcon 5000 Portable HPGe detector. The majority of measurements were made in scattering geometry with the detector situated at 90° to the incident beam, 30 cm from the side of the phantom and approximately 10 cm from the top. A 5 minute background count was acquired and automatically subtracted from all subsequent measurements. Photon spectra were acquired for both open and MLC fields. Results: Based on spectral signatures, nuclides have been identified and their activities calculated for both open and MLC fields. Preliminary analyses suggest that activities from the activation products in the microcurie range. Conclusion: Activation isotopes have been identified and their relative activities determined. These activities are only gross estimates since efficiencies have not been determined for this source-detector geometry. Current efforts are focused on accurate determination of detector efficiencies using Monte Carlo calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Update on DOE Advanced IGCC/H2 Gas Turbine

Cooling Flow Reduction: a) Focus on improving turbine hot gas path part cooling efficiency. b) Applicable to current metallic turbine components and synergistic with advanced materials. c) Address challenges of IGCC/hydrogen fuel environment (for example, possible cooling hole plugging). Leakage Flow Reduction: a) Focus on decreasing turbine parasitic leakages, i.e. between static-to-static, static-to-rotating turbine parts. b) Develop improved seal designs in a variety of important areas. Purge Flow Reduction: a) Focus on decreasing required flows to keep rotor disk cavities within temperature limits. b) Develop improved sealing at the cavity rims and modified flow geometries to minimize hot gas ingestion and aerodynamic impact.

Chupp, Ray↗

Wave-Particle Properties and Pair Formation of the Photon

Models of an individual photon having joint wave-particle properties, needle-like geometry, and spin cannot be based on conventional theory, but be deduced in terms of a revised quantum electrodynamic approach. In this paper the latter is applied to two-slit configurations and electron-positron pair formation: (a) Two-slit experiments performed earlier by Tsuchiya et al. and recently by Afshar et al. demonstrate the joint wave-particle properties of the individual photon, and agree with Einstein's argument against Complementarity. The present theory is consistent with these results, (b) The elementary electron-positron pair formation process is considered, with special attention to the involved orbits, conservation of energy, spin, and electric charge. The obtained model appears to be consistent with the process in which the created electron and positron move along two rays and have original directions along the path of the incoming photon. The nonzero electric field divergence of the theory is associated with an intrinsic local electric charge density. This may explain that the photon can decay on account of the impact from an external electric field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-J-201: Validation Study of Proton Radiography Against CT Data for Quantitative Imaging of Anatomical Changes in Head and Neck Patients

Purpose: In clinical pencil-beam-scanned (PBS) proton therapy, the advantage of the characteristic sharp dose fall-off after the Bragg Peak (BP) becomes a disadvantage if the BP positions of a plan’s constituent pencil beams are shifted, eg.due to anatomical changes. Thus, for fractionated PBS proton therapy, accurate knowledge of the water equivalent path length (WEPL) of the traversed anatomy is critical. In this work we investigate the feasibility of using 2D proton range maps (proton radiography, PR) with the active-scanning gantry at PSI. Methods: We simulated our approach using Monte Carlo methods (MC) to simulate proton beam interactions in patients using clinical imaging data. We selected six head and neck cases having significant anatomical changes detected in per-treatment CTs.PRs (two at 0°/90°) were generated from MC simulations of low-dose pencil beams at 230MeV. Each beam’s residual depth-dose was propagated through the patient geometry (from CT) and detected on exiting the patient anatomy in an ideal depth-resolved detector (eg. range telescope). Firstly, to validate the technique, proton radiographs were compared to the ground truth, which was the WEPL from ray-tracing in the patient CT at the pencil beam location. Secondly, WEPL difference maps (per-treatment – planning imaging timepoints) were then generated to locate the anatomical changes, both in the CT (ground truth) and in the PRs. Binomial classification was performed to evaluate the efficacy of the technique relative to CT. Results: Over the projections simulated over all six patients, 70%, 79% and 95% of the grid points agreed with the ground truth proton range to within ±0.5%, ±1%, and ±3% respectively. The sensitivity, specificity, precision and accuracy were high (mean±1σ, 83±8%, 87±13%, 95±10%, 83±7% respectively). Conclusion: We show that proton-based radiographic images can accurately monitor patient positioning and in vivo range verification, while providing equivalent WEPL information to a CT scan, with the advantage of a much lower imaging dose.

60 APPLIED LIFE SCIENCES↗