Search NASA⌕ Search

SEARCH · Search NASA

Results for “reasoning fabric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

HFIR Steady State Heat Transfer Code (HSSHTC) Statistical Uncertainty Analysis

HSSHTC, the safety basis steady state TH code for HFIR, uses a highly conservative approach in which all input and calculation uncertainties are resolved simultaneously at their most limiting setting. This results in excessive conservatism which does not account for the high unlikelihood of such simultaneous worst-case conditions. The present study explores an alternative approach, BEPU, in which reasonable working assumptions for the probability distribution of each input uncertainty are used to determine a relationship between burnout power margin and core fuel failure probability. This was performed under a philosophy of perturbing uncertainty parameters already defined within the HSSHTC methodology while preserving the HSSHTC calculation approach and solution methodology itself. Based on the assumptions employed in this study, the BEPU approach resulted in a 0.29 increase in burnout power ratio (25 MW increase in burnout power) compared to the latest HSSHTC calculations of C-HFIR-2026-004. The study can be refined in the future by employing fuel fabrication data to provide more realistic input distributions. Future changes to the HSSHTC methodology would potentially allow a more comprehensive treatment of uncertainties which may further increase the burnout power ratio.

Wysocki, Aaron [ORNL] (ORCID:0000000222043779)↗

The impact of temperature, chlorides and sulfate-reducing bacteria on the corrosion of steel in soil

Here, this investigation aimed to study the corrosion performance of low-carbon steel in a soil environment at different temperatures. The steel specimens in the soil were treated at three temperatures: 5, 25 and 60°C. The specimens were embedded in chloride-free soil for 21 days, and then 3.5% (by weight) sodium chloride (NaCl) was added to the soil. The specimens were then kept in the chloride-contaminated soil for 54 days. The results of electrochemical experiments showed superior corrosion performance of the specimens at 60°C, which had the lowest corrosion activity, followed by the specimens at 5 and 25°C. The slow nature of the kinetics of the corrosion reactions at 5°C compared with that at ambient temperature was the reason for this improvement at 5°C. The lower number of microorganisms, including sulfate-reducing bacteria, in the soil at 60°C compared with that at the other temperatures was attributed to the lower corrosion activity of steel in the soil at 60°C compared with the corrosion activity of steel in the soil at other temperatures.

99 - GENERAL AND MISCELLANEOUS↗

Gunn threshold voltage characterization in GaAs devices with wedge-shaped tapering

Here, we fabricate gallium arsenide-based devices with a wedge-shaped tapering region connected to a rectangular-shaped region and measure the threshold voltage required to trigger the Gunn effect. The threshold voltage reduction is attributed to the focusing of the electric field toward the narrower end of the device and is effective when the device has a steep enough tapering. We also model the electric field profile for the tapered devices using an intuitive graphical approach and the finite element method and provide estimates for the threshold voltages of tapered devices. Finally, we compare the estimates to the measured values and provide possible reasons for the discrepancies. We believe the capability of threshold voltage reduction with the wedge-shaped tapering design could be useful in device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser Powder Bed Fusion Manufactured Alloys 625 and 282 and Properties Relevant to Advanced Nuclear Components

Under the Advanced Materials and Manufacturing Technologies program, two Ni-based alloys fabricated by laser powder bed fusion (LPBF) have been evaluated: γ′-strengthened Haynes 282 and solution-strengthened Inconel 625. Large printing defects were observed in the LPBF 282 alloy fabricated using a Renishaw AM250 machine, likely due to particle spattering during printing. Annealing at 1,180°C for 1 h followed by 4 h at 800°C in a high density of 50 nm γ′-strengthening precipitates as well as partial recrystallization resulted in a bimodal grain distribution. Creep testing performed at 750°C revealed lower creep life and ductility for the LPBF 282 compared with wrought 282. X-ray computed tomography combined with optical and scanning electron microscopy microstructural characterization revealed crack formation during creep testing, initiated either from printing defects or from creep cavitation at grain boundaries. Printing defects were the likely reason for the lower creep performance of LPBF 282 and could be suppressed by optimizing the build configuration. Printing 625 on an EOS M290 machine using the recommended EOS parameters resulted in a very low defect density. Superior creep strength at 725°C was observed for the as-printed LPBF 625 along the build direction when compared with wrought 625. No defect larger than ~50 µm could be detected by X-ray computed tomography in the as-printed conditions and after creep testing for 1,000 h at 725°C and 150 MPa. Small, needle-like δ-phase precipitates were observed after creep testing for 100 h at 725°C and 200 MPa. The rapid formation of the γ phase is directly related to the initial Nb and Mo segregation in the LPBF 625 cell walls, and its effect on the alloy’s high-temperature performance will be evaluated. Solution annealing was carried out at 1,150°C for 1 h and led to full recrystallization of the alloy. A decrease in strength and increase in ductility were observed after solution annealing, and the alloy recrystallization resulted in isotropic tensile properties at room temperature, contrary to what was observed for the as-printed LPBF 625.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser-Induced Enhancement of Acoustic Mode Quality Factor Revealed by Correlated Single-Particle Optical and Electron Microscopy

Acoustic modes in plasmonic nanostructures provide fundamental insights into their optomechanical behavior at the nanoscale, enabling emerging applications in plasmon-enhanced optomechanics, ultrasensitive sensing, and nanoscale energy transduction. Here we explore the modulation of acoustic phonon dynamics in lithographically fabricated gold nanodisks via laser-induced photothermal annealing. Using a correlated approach that utilizes both single-particle transient extinction spectroscopy and advanced electron microscopy, we directly link nanoscale structural transformations to changes in mechanical properties as probed through the coherence of the excited acoustic modes. Specifically, ultrafast pump–probe microscopy reveals an enhancement in the acoustic mode quality factor of annealed gold nanodisks, indicative of reduced damping and improved vibrational coherence. Structural characterization via scanning electron microscopy and electron backscatter diffraction confirms that photoinduced annealing results in smoother surface morphology and overall enhanced crystallinity. The improved crystalline order reduces defect and crystal boundary scattering, which we suggest as the reason underlying the lower quality factor before annealing. Furthermore, these findings demonstrate that targeted structural engineering at the nanoscale offers a powerful strategy for optimizing the optomechanical performance of plasmonic nanostructures, with broad implications for the design of next-generation nanophotonic and optomechanical systems.

Annealing (metallurgy)↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

Engineering Thermally Resilient and Kinetically Active Reversible Protonic Ceramic Cells via Interfacial Design

Achieving concurrent fast electrode kinetics and long-term thermo-mechanical durability remains a critical challenge for reversible protonic ceramic electrochemical cells (R-PCECs). Herein, we report an interfacial engineering strategy that integrates a perovs.kite-type PrBaRu0.1Co1.9O5+δ (PBRC) nanoparticle layer onto a PrBa0.5Sr0.5Co1.5Fe0.5O5+δ (PBSCF) substrate (PBRC-PBSCF), together with a modified pellet-assisted sintering approach to fabricate dense BaZr0.4Ce0.4Y0.1Yb0.1O3-δ (BZCYYb4411) electrolytes. The in situ reconstructed heterointerface enhances oxygen reduction/evolution reaction (ORR/OER) kinetics, promotes H2O adsorption/dissociation, and improves steam tolerance, as verified by electrochemical measurements and interfacial microstructural analyses. Density functional theory reveals that Ru-induced electronic modulation at the PBRC-PBSCF interface lowers the energy of oxygen vacancy formation and optimizes the position of the O 2p band center, thereby accelerating oxygen redox kinetics and stabilizing the interface. The resulting R-PCECs deliver an excellent peak power density of 1.112 W cm−2 and an electrolysis current density of −1.257 A cm−2 at 1.3 V in 3% H2O wet air at 600°C, with a reasonable faradaic efficiency. Furthermore, the cells demonstrate excellent stability, sustaining 100 h of thermal cycling (400–600°C, 200°C h−1) in both fuel cell and electrolysis modes, with 600 h of stability in electrolysis mode (600°C, −0.5 to −2 A cm−2).

30 DIRECT ENERGY CONVERSION↗

Universal dwell time optimization for deterministic optics fabrication

Computer-Controlled Optical Surfacing (CCOS) has been greatly developed and widely used for precision optical fabrication in the past three decades. It relies on robust dwell time solutions to determine how long the polishing tools must dwell at certain points over the surfaces to achieve the expected forms. However, as dwell time calculations are modeled as ill-posed deconvolution, it is always non-trivial to reach a reliable solution that 1) is non-negative, since CCOS systems are not capable of adding materials, 2) minimizes the residual in the clear aperture 3) minimizes the total dwell time to guarantee the stability and efficiency of CCOS processes, 4) can be flexibly adapted to different tool paths, 5) the parameter tuning of the algorithm is simple, and 6) the computational cost is reasonable. In this study, we propose a novel Universal Dwell time Optimization (UDO) model that universally satisfies these criteria. First, the matrix-based discretization of the convolutional polishing model is employed so that dwell time can be flexibly calculated for arbitrary dwell points. Second, UDO simplifies the inverse deconvolution as a forward scalar optimization for the first time, which drastically increases the solution stability and the computational efficiency. Finally, the dwell time solution is improved by a robust iterative refinement and a total dwell time reduction scheme. The superiority and general applicability of the proposed algorithm are verified on the simulations of different CCOS processes. A real application of UDO in improving a synchrotron X-ray mirror using Ion Beam Figuring (IBF) is then demonstrated. The simulation indicates that the estimated residual in the 92.3 mm × 15.7 mm CA can be reduced from 6.32 nm Root Mean Square (RMS) to 0.20 nm RMS in 3.37 min. After one IBF process, the measured residual in the CA converges to 0.19 nm RMS, which coincides with the simulation.

36 MATERIALS SCIENCE↗

Manipulation of Hole Spin Transport in Germanium

Downscaling of the silicon metal-oxide-semiconductor field-effect transistor technology is expected to reach a fundamental limit soon. A paradigm shift in computing is occurring. Spin field-effect transistors are considered a candidate architecture for next-generation microelectronics. Being able to leverage the existing infrastructure for silicon, a spin field-effect transistor technology based on group IV heterostructures will have unparalleled technical and economical advantages. For the same material platform reason, germanium hole quantum dots are also considered a competitive architecture for semiconductor-based quantum technology. In this project, we investigated several approaches to creating hole devices in germanium-based materials as well as injecting hole spins in such structures. We also explored the roles of hole injection in wet chemical etching of germanium. Our main results include the demonstration of germanium metal-oxide-semiconductor field-effect transistors operated at cryogenic temperatures, ohmic current-voltage characteristics in germanium/silicon-germanium heterostructures with ferromagnetic contacts at deep cryogenic temperatures and high magnetic fields, evaluation of the effects of surface preparation on carrier mobility in germanium/silicon- germanium heterostructures, and hole spin polarization through integrated permanent magnets. These results serve as essential components for fabricating next-generation germanium-based devices for microelectronics and quantum systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Natural attenuation of uranium in a fluvial Wetland: Importance of hydrology and speciation

A nuclear fuel fabrication facility released 43,500 kg of uranium into a riparian wetland located on the Savannah River Site between 1955 and 1988. Studies were undertaken to evaluate hydrological and geochemical processes influencing uranium accumulation in the wetland. Gamma-radiation-mapping surveys were conducted by systematically walking over the contaminated wetland with backpacks equipped with global positioning systems and NaI gamma detectors. Based on maps compiled from >700,000 gamma spectra and eight sediment uranium depth profiles, it was determined that 94% of the released uranium remained in the wetland. The uranium in the wetland is concentrated in five multi-hectare areas along the stream, accounting for ~11% of the land area adjacent to the stream. While land type (upland or wetland) and topography provided a reasonable first approximation of where much of the uranium was deposited, hydrological watershed modeling revealed that the stream velocity was especially slow through many of the hot spots. Here, using autoradiography combined with SEM/EDX measurements of contaminated sediments, surprisingly few hot particles were detected. Instead, uranium was evenly distributed throughout the sampled sediment, suggesting that dissolved uranium had bound to sediment particles that became suspended and later deposited in low energy (low flow velocity) portions of the stream. EXAFS suggested that U atoms were present as individual ions in disordered complexes within the sediment. Furthermore, linear combination analyses suggested that the predominant component of the U(VI) was adsorbed to sediment minerals (~70%) and a minor component (~30%) was associated with organic matter phases. Furthermore, these studies show that wetlands can be extraordinarily effective at binding and retaining uranium, thereby providing a natural barrier to the transport of uranium out of a watershed. However, significant anthropogenic or climatic changes to wetlands, such as those associated with flooding, forest fires, or land use, may disrupt the complex hydrological and biogeochemical balance necessary to maintain long-term immobilization of uranium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Cost Preform and Molding Processes

The entry cost for prototyping a composite component for manufacture using automated, high rate processes is prohibitively expensive in many cases, especially for small business, where tooling costs may be several $100k. Discussions with industry also indicate that many small companies, tier 1 and 2 suppliers, have an interest to mold composite parts but do not want to deal with the capital cost, material handling issues, and labor associated with dry fiber preforming operations. While the molders may locate near the end user for logistics reasons, it may be more cost effective for the performer to remain regional and invest in capital equipment to support preform automation, thus keeping costs to a minimum. This project was designed to explore and demonstrate several options to meet these industry needs. Dry fiber preforming approaches were evaluated which allow for low pressure resin infusion, single sided tooling options such a vacuum assisted resin transfer molding (VARTM) or low pressure resin transfer molding (RTM-light). Unlike sheet molding compound, SMC compression molding where typical molding pressures of 1000 psi are required to push material into the desired location; positioning of a dry fiber preform into the desired location on the tool allows for low molding pressures of 10-50 psi. Lower molding pressures allow for use of low cost, additive fabrication of polymeric tooling. Polymeric tooling is suitable for rapid part prototyping and limited production. Dry fiber preforming approaches evaluated included use of commercial chopped strand mat, robotic chopper gun deposition, and continuous fiber preform augmentation using tailored fiber placement (TFP). Use of chopped strand mat does not require a robotic deposition method, however a cutting table is generally required and there is typically 20-30% scrap generation. While various fiber areal weights are available, the preform is not readily optimized for minimal fiber use or weight savings. In contrast, a robotic chopper gun approach allows for localized deposition where fiber is required to meet structural requirements. The robotic method is highly automated and minimizes fiber scrap, however the capital cost of the equipment and engineering labor for programming can result in higher preform cost compared to chopped strand mat in certain cases depending on preform complexity. Dry fiber preforming using the robotic chopper gun method allows for creation of three dimensional forms. This approach may be ideal for molding in-house, or if the preforms stack together densely to allow for efficient shipping. Applications evaluated for this program considered trade-off between fabrication of a fully 3D preform versus production of a flat preform which is designed to readily drape into the final desired shape. Such a preform design greatly simplifies robotic programming and requires no specialized tooling. The flat preforms are easily stacked and shipped to the final molding location. Flat preforms are much easier to augment with TFP continuous fiber to provide local reinforcement. The demonstration and evaluation of these preforming and tooling methods were completed on three component applications. The first application was a battery box cover for an electric vehicle which was highly three dimensional. The second demonstrator article was comprised of complex contours and was used to demonstrate the use of TFP and RTM-light molding process. The third demonstration article was the roof of an operator’s cab for large construction equipment. The roof is relatively flat however it is comprised of complex changes in thickness which clearly demonstrate the advantage of robotic chopper gun approach as compared to using numerous preform layers of chopped strand mat. The cost trades for the various preforming methods are summarized to help guide the reader as to preforming method considerations. Finally, these demonstrations all used glass fiber roving. A fourth, exploratory task was added to evaluate the ability to make preforms using Zoltek’s carbon fiber split tow roving. We were able to adapt the chopper gun to make flat preforms for laminate testing, but further development effort would be required to make suitable preforms.

36 MATERIALS SCIENCE↗

Development of coated heat flux gauges for fast responding measurements

Thermal systems often exhibit transient behaviors that have important implications for the operation of the system and can be difficult to predict. For these reasons, experimental testing is often required to ensure system durability requirements are achieved. One important parameter governing the survivability of components in hot, high-stress environments is the heat flux into the part that dictates the temperature distribution for the component. However, sensors required to experimentally characterize heat fluxes in extreme environments must also be resilient. Here, this study presents the development of coated heat transfer gauges capable of robust, high-frequency measurements in turbine research facilities. The addition of a protective coating increases the durability of the gauge, but inherent of that coating is the attenuation of high-frequency temperature penetrations. As a result, this study first outlines the use of analytical solutions to define a gauge design for a specific frequency range and heat transfer, ensuring that subsurface signals can be rectified to surface conditions through inverse methods. Then, the fabrication of polyimide substrate sensors with a parylene-F coating is described. Micro surface heaters added to the custom sensors were used to determine important geometric and thermal properties necessary to calculate accurate surface heat flux. Ultimately, this work shows increased sensor robustness in a turbine test bed and experimentally validates that the frequency response of the fabricated sensors meet the design intent.

47 OTHER INSTRUMENTATION↗

Hanford Immobilized Low-Activity Waste Transportation System Testing Results - 20043

The immobilized low-activity waste (ILAW) transportation system is a first-of-a-kind system that is being designed and tested to transport ILAW glass-filled containers from Hanford's Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility to the Integrated Disposal Facility (IDF) burial trench for permanent disposal. A prototype design and fabrication of one transport trailer and four engineered ILAW pallets was completed in mid-2018. Prototype qualification testing to verify adequacy of the design was completed in 2019 by Washington River Protection Solutions (WRPS) and affiliate ATKINS SNC-Lavalin Group. Prototype testing was completed to advance design maturation across all operational and facility interfaces, and under adverse environmental and operating conditions, including thermal assessment of the system at peak projected temperatures. Test design, observation, and feedback was well represented and supported by all ILAW Transportation System interfacing organizations: WTP constructor Bechtel National, Inc.; IDF operator CH2M (CHPRC); transportation contractor Mission Support Alliance (MSA); the U. S. Department of Energy Richland Operations Office (DOE/RL) and Office of River Protection (DOE/ORP); and Washington State Department of Ecology. This paper presents the results of prototype qualification testing and opportunities for design improvements based on testing. Changes to the final design as a result of prototype testing include improvements in safety, ergonomics, operational flexibility, and As-Low-As-Reasonably-Achievable (ALARA) applications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent-Mediated Synthesis of Amorphous Li 3 PS 4 /Polyethylene Oxide Composite Solid Electrolytes with High Li + Conductivity

Solvent-mediated routes have emerged as an effective, scalable, and low-temperature method to fabricate sulfide-based solid-state electrolytes. However, tuning the synthesis conditions to optimize the electrolyte’s morphology, structure, and electrochemical properties is still underexplored. Here, we report a new class of composite solid electrolytes (SEs) containing amorphous Li 3 PS 4 synthesized in situ with a poly(ethylene oxide) (PEO) binder using a one-pot, solvent-mediated route. The solvent and thermal processing conditions have a dramatic impact on the Li 3 PS 4 structure. Conducting the synthesis in tetrahydrofuran resulted in crystalline β-Li 3 PS 4 whereas acetonitrile led to amorphous Li 3 PS 4 . Annealing at 140 °C increased the Li + conductivity of an amorphous composite (Li 3 PS 4 + 1 wt % PEO) by 3 orders of magnitude (e.g., from 4.5 × 10 –9 to 8.4 × 10 –6 S/cm at room temperature) because of: (i) removal of coordinated solvent and (ii) rearrangement of the polyanionic network to form P 2 S 7 4– and PS 4 3– moieties. The PEO content in these composites should be limited to 1–5 wt % to ensure reasonable Li+ conductivity (e.g., up to 1.1 × 10 –4 S/cm at 80 °C) while providing enough binder to facilitate scalable processing. Here, the results of this study highlight a new strategy to suppress crystallization in sulfide-based SEs, which has important implications for solid-state batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AGR-5/6/7 Thermal Model with Non-uniform Gas Gaps

Fuel compact temperatures are a crucial factor in assessing irradiation performance of the Tristructural isotropic fuel particles. In the absence of direct measurement, fuel compact temperatures were calculated using a three-dimensional finite element thermal model, which is subject to simulation uncertainty. The most dominant factor in uncertainty of calculated fuel temperature is the gas gap uncertainty due to the nub-to-shell clearance because of fabrication error. A revision to the thermal model was made to examine the most probable offset position for four different dates of interest. The offset position options varied in magnitude and azimuthal direction of offset of the holder top and bottom position. The best-fit offset of the holder is estimated based on the minimum root mean square error of residuals for all operational thermocouples (TCs). From these results, the following conclusions were made: 1) During earlier cycles (162A – 164A) when numerous TCs were still operational, the best-fit offset distance varied in range [0.002 – 0.0035 in.] for both the top and bottom holder while offset azimuthal direction varied widely, especially for the holder bottom. 2) Holder offset led to slightly lower Capsule 1 average temperature, but wider temperature variation (lower minimum and higher peak fuel temperatures). 3) The maximum offset of 0.006 in. to the northwest direction for both the top and bottom holder yielded a much higher temperature than the original peak fuel temperature, which increased from 1422 to 1557 ? (or 135 ? increase). This could be one of the reasons for massive particle failure near the end of Cycle 165A. 4) Even though, the highest temperature at the TC-1-7 tip reached slightly higher than 1000?, the temperature along the TC wire reached as high as 1335? assuming a holder offset of 0.006 in. to the northwest. Consequently, at this temperature nickel from this TC wire could cause particle failures in Capsule 1.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wide bandgap photoconductor (SiC:V)-based optically addressed light valve for high fluence operation

Optically addressable light valves based on wide bandgap 4H- and 6H-SiC as photoconductors were designed to withstand higher operational laser fluences than the state of-the-art bismuth silicon oxide (BSO; Bi 12 SiO 20 ) based devices. Vanadium-doped SiC was selected as the photoconductors due to their reasonable photoresponsivity while many fold improvement in laser induced damage threshold as compared to BSO. The laser induced damage threshold values of the materials were measured after exposing ~ 200 sites on the samples to increasing levels of fluence of a gaussian pulsed Nd: YAG laser system (1064 nm) with a 5 Hz repetition rate. The measured damage threshold values for BSO, 4H- and 6H-SiC were 0.4 J/cm 2 , 1.75 J/cm 2 and 1.8 J/cm 2 , respectively. Photoconductive switches based on 4H and 6H-SiC samples were characterized at wavelengths of 380 nm, 405 nm, and 447 nm. The peak photoresponsivity values of the 4H- and 6H-SiC materials were measured to be under 380 nm and 405 nm, respectively. The photoconductor was bonded to a BK7 optical window with 5 μm diameter microspheres as spacers. A twisted nematic type E7 liquid crystal (LC) was filled in the 5 μm gap in a vacuum chamber. The desired alignment of the liquid crystal was achieved by mutually orthogonal orientation of LC alignment layers on the two mating faces (SiC and BK7). The fabricated devices were modulated using address beams of wavelengths 380 nm, 405 nm, and 447 nm. In conclusion, required transmission levels of > 90% was achieved for the fabricated OALVs for a sinusoidal voltage waveform that meets the lifetime requirement of the device.

36 MATERIALS SCIENCE↗

Initial Efforts Organizing WPNCS SG-8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks

The Working Party on Nuclear Criticality Safety (WPNCS) under the guidance of the Organization for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) has over 20 years of experience addressing concerns related to static and transient configurations encountered within the nuclear fuel cycle: fuel fabrication, transportation, reprocessing, storage, and geological disposal. One of the cornerstone activities of the WPNCS is the International Criticality Safety Benchmark Evaluation Project (ICSBEP), which was established to identify a comprehensive set of criticality benchmark data, evaluate the data, including quantification of overall uncertainties; compile the data into a standardized format, perform sample calculations utilizing modern nuclear data sets and codes utilized in nuclear criticality safety, and formally document the work into a single source of verified benchmark data. Annually, members of the ICSBEP Technical Review Group (TRG) contribute evaluated benchmark data that undergoes comprehensive technical review prior to publication in the ICSBEP Handbook. In the years since the ICSBEP was established, there has been much work to prepare benchmark data to support validation activities in nuclear criticality safety. The 2020 edition of the ICSBEP Handbook contains acceptable benchmark specifications for 5,053 critical, subcritical, or near-critical configurations in 582 benchmark evaluations. Modern benchmark development benefits from decades of experienced international participants, a well-established handbook format, supplementary guides to deal with uncertainty quantification, and a comprehensive review process based upon independent reviews from international experts. The ICSBEP Handbook also contains 838 configurations deemed unacceptable to support criticality safety efforts. They are recorded, with the reasoning for their rejection, to preserve the experimental data, prevent reevaluation of data that are incomplete or contain known errors, and/or to potentially allow future reevaluation of the experiment pending the identification of sufficient data to resolve identified inconsistencies and errors. Users of the ICSBEP Handbook today might notice that the rigor and quality of modern criticality safety benchmarks is much greater than those prepared within the initial decade of the project. Benchmarks with 1s uncertainties in k eff greater than 1% were traditionally rejected unless they were identified as unique experiment types that encompassed materials, fuels, or designs not available from other benchmark experiments. However, benchmarks developed using modern experimental techniques and practices typically have uncertainties on the order of a few tenths of a percent. There have been ongoing efforts to improve the overall quality of previously published benchmark evaluations. Seventy-eight evaluations, containing approximately 600 configurations, have been revised just within the past decade. An additional eleven benchmarks are under revision for updated release in the 2020 edition of the ICSBEP Handbook. If some of the historic benchmarks were resubmitted in their current form to the TRG today, they would be rejected due to lack of data, missing components in the uncertainty analysis, or incomplete benchmark model development. The use of historic criticality safety benchmarks that underestimate the total uncertainty, lack properly quantified biases, or provide inadequate benchmark specifications do not sufficiently support modern criticality safety and nuclear data efforts. Although the ICSBEP Handbook is recognized by regulating bodies to support criticality safety, users are required to justify their reasons to ignore historic benchmark data and include additional safety margins within their designs. Discussions were held at the WPNCS 23rd Annual Meeting in September 2019 regarding the aforementioned issues. The resultant decision was to establish Subgroup 8 (SG-8): Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks. The current activities of SG-8 are discussed herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated Heat Exchanger-Phase Change Material Thermal Energy Storage System

The purpose of this study is to experimentally investigate the thermal performance of an innovative thermal energy storage (TES) system that combines the advantages of the phase-change material (PCM)/graphite foam latent heat TES medium developed at Argonne National Laboratory (Argonne) and the internally supported plate-fin (ISPE) cell architecture heat transfer fluid (HTF) flow channels developed at Brayton Energy (Brayton). Several essential tasks were accomplished: (1) Thermal property characterization. Thermal properties of the graphite foam were characterized, providing necessary data for experimental result analysis and numerical simulation. (2) Design and optimization of lab-scale test module. Based on Brayton’s full-scale heat exchanger (HX)-TES system, the experimental test module was designed, optimized, and fabricated. (3) Thermal performance testing and data analysis. Five cycle tests were successfully conducted—including one with approximately 3.5 psig of pressure applied to the diaphragms—to investigate the thermal performance of the experimental test module for charging and discharging. Temperature profiles were generated for each charging test and discharging test as a function of time. The temperature profiles clearly show three TES stages: sensible heat (temperature increase), latent heat (melting), and sensible heat (temperature increase) for the charging process. Similarly, the temperature profiles clearly show three thermal energy release stages: sensible heat (temperature decrease), latent heat (solidification), and sensible heat (temperature decrease). Melting and solidification of the PCM generally occurred in relatively narrow temperature ranges, indicated by the flattened temperature regions in the temperature profiles. These phase changes ranged approximately 3°C for melting and 3.5°C for solidification. The charging and discharging temperature profiles were similar for similar experimental parameter tests whether or not pressure was applied to the diaphragm to eliminate the gap between the HX surface and the TES subsystem. This indicates that the effect of a small gap between the HX surface and the TES subsystem is insignificant for charging and discharging. (4) Comparison of experimental data and simulation results. We compared the experimental data to the numerical simulation results. Numerical simulations were conducted by using the ANSYS FLUENT 2019 R3 commercial computational fluid dynamics software. The predicted phase-change times agreed reasonably well with those from the experimental data. In most cases, the estimated time differences between the relative phase changes were within 16%. The predicted start and end times for the charging process agreed well with those from the experimental data. However, the simulation results showed earlier start and end times than the experimental data for the discharging process. Overall, the experimental data and its comparison with the simulation predictions verified the technical viability of the integrated ISPF HX-PCM/graphite foam latent-heat TES system.

25 ENERGY STORAGE↗