Multi-stacked InAs/GaAs quantum dots grown with different growth modes for quantum dot solar cells
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The incorporation of plasmonic nanostructures in the thin-film solar cells (TFSCs) is a promising route to harvest light into the nanoscale active layer. However, the light trapping scheme based on the plasmonic effects intrinsically presents narrow-band resonant enhancement of light absorption. Here we demonstrate that by cascading metal nanogratings with different sizes atop the TFSCs, broadband absorption enhancement can be realized by simultaneously exciting multiple localized surface plasmon resonances and inducing strong coupling between the plasmonic modes and photonic modes. As a proof of concept, we demonstrate of 66.5% in the photocurrent in an ultrathin amorphous silicon TFSC with two-dimensional cascaded gratings over the reference cell without gratings.
Determining the power conversion efficiency of photovoltaic solar cells, especially those from new, emerging areas of technology, is important if advances in performance are to be made. However, although precise measurements are important, it is the accuracy of these types of measurements that can cause issues. Accurate measurements not only promote the development of new technology platforms, but they also enable comparisons with established technologies and allow assessments of advancements within the same field. This chapter provides insights into how measurements can be made with reasonable accuracy using both the components of the measuring system and a good protocol to acquire good data. The chapter discusses how to measure a calibrated lamp spectrum, determine a spectral mismatch factor, identify the correct reference cell and filter, define the illuminated active area, measure J-V curves to avoid any hysteresis effects, take note of sample degradation issues and avoid the temptation to artificially enhance efficiency data.
A simple hydrogen adsorption measurement system utilizing the volumetric differential pressure technique has been designed, fabricated and calibrated. Hydrogen adsorption measurements have been carried out at temperatures 298 K and 77 K on activate carbon and carbon nanotubes with different surface areas. The adsorption data obtained will be helpful in understanding the adsorption property of the studied carbon materials using the fundamentals of adsorption theory. The principle of the system follows the Sievert-type method. The system measures a change in pressure between the reference cell, R1 and the sample cell S1, S2, S3 over a certain temperature range, R1, S1, S2, and S3 having known fixed volume. The sample temperatures will be monitored by thermocouple TC while the pressures in R1 an S1, S2, S3 will be measured using a digital pressure transducer. The maximum operating pressure of the pressure transducer is 20 bar and calibrated with an accuracy of +-0.01 bar. High purity hydrogen is being used in the system and the amount of samples for the study is between 1.0-2.0 grams. The system was calibrated using helium gas without any samples in S1, S2 an S3. This will provide a correction factor during the adsorption process providing an adsorption free reference point when using hydrogen gas resulting in a more accurate reading of the adsorption process by eliminating the errors caused by temperature expansion effects and other non-adsorption related phenomena. The ideal gas equation of state is applied to calculate the hydrogen adsorption capacity based on the differential pressure measurements. Activated carbon with a surface area of 644.87 m{sup 2}/g showed a larger amount of adsorption as compared to multiwalled nanotubes (commercial) with a surface area of 119.68 m{sup 2}/g. This study als indicated that there is a direct correlation between the amounts of hydrogen adsorbed an surface area of the carbon materials under the conditions studied and that the adsorption significant at 77 K.
Quantum dot solar cells (QDSCs) comprised of 10 stacked pairs of strain-compensated InGaAs/GaNAs QD structure have been fabricated by atomic hydrogen-assisted molecular beam epitaxy. A homogeneous and high-density QD array structure with improved in-plane ordering and total density of {approx}10{sup 12} cm{sup -2} has been achieved on GaAs (311)B grown at 460 Degree-Sign C after stacking. The external quantum efficiency (EQE) of InGaAs/GaNAs QDSC increases in the longer wavelength range due to additive contribution from QD layers inserted in the intrinsic region. The short-circuit current density measured for QDSC is 17.2 mA/cm{sup 2} compared to 14.8 mA/cm{sup 2} of GaAs reference cell. Further, an increase in EQE due to photocurrent production by 2-step photon absorption has been observed at room temperature though it is still small at around 0.1%.
Accurate performance calibration of multijunction (MJ) solar cells is critical for advancing this technology toward large-scale terrestrial application, yet existing testing methods developed by photovoltaics calibration laboratories remain prohibitively complex and resource intensive for most research laboratories. Current approaches rely on expensive multisource simulators and/or intricate spectral tuning algorithms, limiting accessibility and hindering standardized comparisons of emerging MJ technologies such as perovskite-based tandems. This paper introduces a streamlined spectral irradiance adjustment method for light-emitting diode (LED)-based solar simulators, which are increasingly adopted in the photovoltaics community due to their versatility and cost-effectiveness. The method we present bins LED channels into groups based on the number of junctions of the MJ photovoltaic device under test (DUT) and their corresponding band gaps and incorporates an automated tuning algorithm that eliminates the need to adjust each channel’s irradiance individually. This tuning algorithm requires the relative spectral responsivities of both the DUT and a broadband reference cell, as well as a calibrated spectroradiometer. Measurement validation across various MJ devices, including III-V and perovskite/silicon tandems, demonstrates excellent agreement within 1% with well-established xenon-tungsten multisource simulators and associated tuning algorithms. By enabling precise spectral tuning with readily available equipment and a simple tuning algorithm, our approach bridges the measurement accuracy gap between research laboratories and accredited testing facilities, fostering more reliable device comparisons and accelerating the translation of MJ technologies into real-world energy systems.
This study presents indoor and field validation results for two versions of the “DUSST” optical soiling sensor, intended to be a low-cost and low-maintenance device for measuring photovoltaic soiling losses. Indoor testing covers irradiance calibration and temperature dependencies, which are necessary to achieve high accuracy, low uncertainty field measurements. Field testing includes an array of different environments including Saudi Arabia, California, Utah, and Colorado. DUSST versions include a configuration with a 530-nm light emitting diode (LED) (discussed in previous work) and a unit with seven white LEDs and a polycarbonate collimating optic. The new design increases light intensity fivefold and demonstrates a single linear calibration coefficient is effective to measure soiling losses as high as 75%. Field data from Utah and California demonstrate that daily soiling loss measurements and soiling rate calculations closely match both reference cell and full-size module measurements of soiling losses and soiling rates. Corrective methods employed on the Utah DUSST sensor suggest that it is possible to achieve measurement errors as low as ±0.1% at two standard deviations. Field data from both Colorado and Saudi Arabia demonstrate that LED lens soiling can occur and that further design optimizations are needed. The lesson learned from all the field deployment locations suggests directions for future design improvements.
Here, we report the development of SOMAFOAM, a finite volume framework for performing continuum simulations of low-temperature plasmas. The primary goal of this work is to discuss the features of SOMAFOAM along with representative results provided as examples for a range of operating conditions and geometries. This includes plasma and plasma–dielectric systems operating in direct current, radio frequency, and microwave regimes from pressures as low as 100 mTorr to atmospheric pressure. The code has several useful features including the ability to run massively parallel simulations using arbitrary geometries, structured/unstructured meshes, choice of models such as drift–diffusion/full-momentum at runtime, and species-dependent timesteps to name a few. The verification/validation studies presented include comparison with previously published continuum simulations (low-pressure direct current and radio frequency plasma), with experiments (Gaseous Electronics Conference Reference Cell and microwave microplasma ignited in a split ring resonator), and previously published kinetic simulations (low-pressure radio frequency plasma). Other examples provided include a direct current atmospheric pressure microplasma bounded by dielectric sidewalls and a helium–nitrogen plasma ignited using a needle electrode facing a dielectric. The performance of the code is also discussed with serial and distributed memory parallel runs demonstrated up to 512 cores. The design and implementation of the code in a modular object-oriented framework allows for easy extension and seamless coupling with other codes and can be expected to play an important role in both academia and industry.
Here, the authors regret they have discovered errors in Eq. (3) and in a spreadsheet used to calculate cosmogenic exposure ages shown in Table 1. Eq. (3) is missing a term. The spreadsheet errors concerned an incorrect cell reference and application of Eq. (3). Correction of these errors results in ~15–20% changes to the exposure ages of all samples, minor (generally <0.2%) changes to the radioisotopic ages of some samples (those that entailed a correction for chlorine-derived 38Ar calculated based on the exposure age; see Section 3.3), and statistically insignificant changes to the inferred trapped components identified through isochron analyses. These modifications have no impact on the modeling, discussions, or conclusions in the paper, nor do the changes to radioisotopic ages exceed the 1 sigma uncertainties.
Here the well-known Fresnel equations solve for the reflection and transmission of light for precise incident angles. The transmission of diffuse radiation incident on a planar or domed surface is often needed for real-world applications. Due to the complexity of the Fresnel equations, the analytical solution of the integration has hitherto been unobtainable over the last centuries. Therefore, this problem was numerically solved by integrating the angular transmittances in space often leading to substantial computing burden and bias in the results. To efficiently estimate the solar energy resource for a glass-covered photovoltaic (PV) module, we derive an analytical solution of diffuse transmission based on the rigorous integration of an alternate form of the Fresnel equations. The approach leads to a simple yet accurate relative transmittance model that reconciles the solar energy sensed by pyranometers and PV panels. With limited and clearly stated approximations, the complex mathematical derivation resulted in an elegant solution. An experiment using 1-year of data at the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) shows that the new model dramatically decreases the disparity between the solar radiation measurements by a Kipp and Zonen CM Pyranometer 22 (CMP22) and an IMT reference cell on a 1-axis tracking system. The solution in this paper can be widely used in scientific and engineering research, development, and applications wherever the Fresnel equations are used.
Thin film based differential scanning calorimeter (DSC) was developed and utilized for the study of phase-transition kinetics in protein samples. In this paper, we proposed a MEMS based DSC model. The distance between the sample and reference cell was optimized based on the thermal analysis result. The influence of the response time to the shape of the DSC thermograms and the transition temperature was also studied systematically. Meanwhile, Lumry-Eyring model was used to investigate the relationship between the scanning rate and the transition temperature. The modeling result was verified by the lysozyme denaturation tests. This study provided a pathway for the optimization of MEMS based DSC array and the correction of the DSC thermograms.
This paper reports the modelling of CCP-RF discharges (13.56 MHz) in pure nitrogen, produced within a cylindrical parallel-plate reactor, similar to a GEC reference cell surrounded by a lateral grounded grid, at 0.1-2 mbar pressures and 10-50 W coupled powers. This study is a first step in simulating Titan's chemistry at laboratory scale, using the PAMPRE experiment. Modelling results are compared with experimental measurements of the average electron density, and the self-bias potential at the polarized electrode.
The oscillation spectrum of a one-dimensional vertical dust string formed inside a glass box on top of the lower electrode in a gaseous electronics conference (GEC) reference cell was studied. A mechanism for creating a single vertical dust string is described. It is shown that the oscillation amplitudes, resonance frequencies, damping coefficients, and oscillation phases of the dust particles separate into two distinct groups. One group exhibits low damping coefficients, increasing amplitudes, and decreasing resonance frequencies for dust particles closer to the lower electrode. The other group shows high damping coefficients but anomalous resonance frequencies and amplitudes. At low oscillation frequencies, the two groups are also separated by a {pi} phase difference. One possible cause for the difference in behavior between the two groups is discussed.
The texture or patterning of soil on PV surfaces may influence light capture at various angles of incidence (AOI). Accumulated soil can be considered a microshading element, which changes with respect to AOI. Laboratory deposition of simulated soil was used to prepare test coupons for simultaneous AOI and soiling loss experiments. A mixed solvent deposition technique was used to consistently deposit patterned test soils onto glass slides. Transmission decreased as soil loading and AOI increased. Dense aggregates significantly decreased transmission. But, highly dispersed particles are less prone to secondary scattering, improving overall light collection. In order to test AOI losses on relevant systems, uniform simulated soil coatings were applied to split reference cells to further examine this effect. Finally, the measured optical transmission and area coverage correlated closely to the observed $I_{{rm SC}}$. Angular losses were significant at angles as low as 25°.
Historically, the tools used at NREL to compensate for the difference between a reference spectrum and a simulator spectrum have been well-matched reference cells and the application of a calculated spectral mismatch correction factor, M. This paper describes the algorithm for adjusting the spectrum of a 9-channel fiber-optic-based solar simulator with a uniform beam size of 9 cm square at 1-sun.The combination of this algorithm and the One-Sun Multi-Source Simulator (OSMSS) hardware reduces NREL's current vs. voltage measurement time for a typical three-junction device from man-days to man-minutes. These time savings may be significantly greater for devices with more junctions.
Natural soiling, or the deposition of ambient particulate matter (PM) onto the surface of solar glass, causes losses in PV production around the world. Much work in the PV community has focused on soiling in dusty desert environments. However, PV systems in urban environments are exposed to different contaminants and thus soil differently. We present an analysis of PV soiling in such an urban environment considering the impacts of meteorological parameters. We present 1 year of results from a soiling station in an urban location in Colorado. Bare glass samples were exposed outdoors for 11 days alongside the station; results from microscopy and light transmittance measurements show how moisture and dew affect the morphology and optics of contamination on glass. The coupon results suggest that natural (rain) cleanings may not be sufficient to clean solar panels in urban environments. Ion chromatography of soiling on the reference cell surfaces suggest that dry brush cleanings may not sufficiently clean chemicals deposited on solar panel surfaces in urban environments.
Accurately determining PV module performance in the field requires measurement of solar irradiance reaching the PV panel at a high level of accuracy and known uncertainty. Silicon detectors used in various solar energy measuring instruments including reference cells are potentially an attractive choice for multiple reasons that include faster responsivity than thermopile detectors, cheaper cost and lower maintenance. The main drawback though is the fact that the silicon detectors are only spectrally responsive in a narrow part of the solar spectrum. Therefore, to determine broadband solar irradiance a calibration factor that converts the narrowband response to broadband is required. Normally this calibration factor is a single number determined under standard conditions but then used for various scenarios including varying air-mass, panel orientation and atmospheric conditions. This would not have been an issue if all wavelengths that form the broadband spectrum responded uniformly to atmospheric constituents. Unfortunately the scattering and absorption signature varies widely across wavelengths and the calibration factor computed under certain test conditions is not appropriate for other conditions. This paper lays out the issues that will arise from the use of silicon detectors for PV performance measurement in the field. We also present a comparison of simultaneous spectral and broadband measurements from silicon and thermopile detectors and estimated measurement errors when using silicon devices for both array performance and resource assessment.
Methods and systems for detecting a gas or liquid in an environment include measuring a reference signal at each of a set of wavelengths by passing a signal at each wavelength through a reference cell having a gas or liquid to be detected. A sensing signal is measured at each of the plurality of wavelengths by coupling each wavelength to a ring resonator in the environment. A set of wavelengths that correspond to an absorption curve of the gas or liquid to be detected is determined. A concentration of the gas or liquid to be detected in the environment is determined based on amplitudes of the sensing signal at each of the set of wavelengths.