Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

US-DOE and Republic of South Africa Uranium Benchmarking: Results From Los Alamos National Laboratory (Study Report)

This report details work performed at Los Alamos National Laboratory (LANL) in support of an interlaboratory uranium (U) benchmarking collaboration between LANL, Lawrence Livermore National Laboratory (LLNL), and South African Nuclear Energy Corporation (Necsa). The goal of this interlaboratory benchmarking exercise is to compare analytical methods and data obtained on uranium reference materials CUP-2 and New Brunswick Laboratory (NBL) certified reference material (CRM) 124-2. The LANL commitments for this project include performing microwave digestion of fresh CUP-2 and CRM 124-2 powders, measuring the U isotope composition of CUP-2 and CRM 124-2 by both single-collector and multi-collector inductively coupled plasma mass spectrometry (SC-ICP-MS and MC-ICP-MS, respectively), and determining trace-element abundances in CUP-2 and CRM 124-2 by inductively coupled plasma mass spectrometry (ICP-MS). This report details the methods employed by LANL in support of these objectives and presents the data obtained during this collaborative exercise.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Developmental status of thermionic materials.

Description of the reference materials selected for the major components of the unit cell of a thermionic pile element (TFE), the out-of-pile and in-pile test results, and current efforts for improving the life and performance of thermionic fuel elements. The component materials are required to withstand the fuel burnup and fast neutron fluence dictated by the thermionic reactor system. Tungsten was selected as the cladding material because of its compatibility with both the carbide and the oxide fuel materials. Niobium was selected as the collector material because its thermal expansion coefficient matches closely with that of the thin aluminum oxide layer used to electrically insulate the collector from the TFE sheath. An unfueled converter has performed stably over 41,000 hr. Accelerated irradiation tests have attained burnups equivalent to that for 40,000 hr of the thermionic reactor under consideration.

Yang, L.↗

Toward an international practical pressure scale: A proposal for an IPPS ruby gauge (IPPS-Ruby2020)

At the 26 th AIRAPT conference in 2017, a task group was formed to work on an International Practical Pressure Scale (IPPS). This report summarizes the activities of the task group toward an IPPS ruby gauge. We have selected three different approaches to establishing the relation between pressure ( P ) and ruby R1-line shift ( Δλ ) with three groups of optimal reference materials for applying these approaches. Using a polynomial form of the second order, the recommended ruby gauge (referred as Ruby2020) is expressed by: P [ G P a ] = 1.87 ( ± 0.01 ) × 10 3 Δ λ λ 0 1 + 5.63 ( ± 0.03 ) Δ λ λ 0 , where λ 0 is the wavelength of the R1-line near 694.25 nm at ambient condition. In June of 2020, the Executive Committee of AIRAPT endorsed the proposed Ruby2020. Finally, we encourage high-pressure practitioners to utilize Ruby2020 within its applicable pressure range (up to 150 GPa), so that pressure data can be directly compared across laboratories and amended consistently as better scales emerge in the future.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tetrafluoroboric Acid Digestion for Accurate Determination of Rare Earth Elements in Coal and Fly Ash by ICP-MS Analysis

Coal and coal-related fly ash often contain rare earth elements (REEs) that have the potential to be utilized as valuable mineral resources. Accurately determining the REE content in coal and fly ash is crucial for resource evaluation. The conventional approach involves using hydrofluoric acid (HF) to dissolve silicates and release REEs, which, however, prolongs the digestion process due to the additional step of complexing fluoride ions (F−) with boric acid (H3BO3). Determining the correct amount of H3BO3 for neutralization can be challenging, and in some instances, the binding of fluoride ions with certain lanthanides (Lns) hampers the accurate determination of all 14 naturally occurring rare earth elements in a single digestion batch by inductively coupled plasma mass spectrometry (ICP-MS). In this study, we present an alternative method that achieves the accurate determination of all 14 naturally occurring REEs using tetrafluoroboric acid (HBF4) followed by ICP-MS analysis. This approach eliminates the need for an F− complexing step. We tested this method on certified REE reference materials, including NIST 1632e (coal) and NIST 1633c (fly ash), as well as the REE geological reference material USGS AGV-1 (andesite). Our results demonstrated excellent recovery rates (relative standard deviation, RSD < ±10%), with a correlation coefficient (r2) exceeding 0.99. Using this method, we investigated the concentrations of all 14 REEs in coal and fly ash samples collected from various locations in the southwestern USA. This improved digestion technique streamlines the analysis process and enhances the accuracy of REE determination, facilitating a more comprehensive evaluation of REE-rich coal and fly ash deposits for resource exploration.

58 GEOSCIENCES↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

Product Consistency Test Results for the LAW Phase 5 Glasses

This report provides the results of the Vapor Hydration Test solutions and the Product Consistency Test leachates from the Low-Activity Waste Phase 5 glasses, a series of simulated nuclear waste glasses fabricated at the Pacific Northwest National Laboratory. The series included quenched and canister-centerline cooled versions of the glasses. These data will be used in the development of enhanced property/composition models for waste glass vitrification at Hanford. Several of the blanks had detectable amounts of sodium and/or silicon. The measured concentrations (mg/L) of boron, sodium, and silicon for the low-activity test reference material glass included with the Product Consistency Tests were much lower than the expected low-activity test reference material test results. A review of the Product Consistency Test data indicated that there was generally little difference between the normalized values based on targeted or measured glass composition. Heat treatment had various impacts on the normalized concentration values. Most of the glasses had NC B , NC Na , and NC Si values that were greater than the Hanford Tank Waste Treatment and Immobilization Plant low-activity waste constraint of 4 g/L. The release rates for boron, sodium, and silicon were highly correlated for the study glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative Technique for Comparing Simulant Materials through Figures of Merit

The 1989 workshop report entitled Workshop on Production and Uses of Simulated Lunar Materials and the Lunar Regolith Simulant Materials: Recommendations for Standardization, Production, and Usage, NASA Technical Publication both identified and reinforced a need for a set of standards and requirements for the production and usage of the Lunar simulant materials. As NASA prepares to return to the Moon, and set out to Mars, a set of early requirements have been developed for simulant materials and the initial methods to produce and measure those simulants have been defined. Addressed in the requirements document are: 1) a method for evaluating the quality of any simulant of a regolith, 2) the minimum characteristics for simulants of Lunar regolith, and 3) a method to produce simulants needed for NASA's Exploration mission. As an extension of the requirements document a method to evaluate new and current simulants has been rigorously defined through the mathematics of Figures of Merit (FoM). Requirements and techniques have been developed that allow the simulant provider to compare their product to a standard reference material through Figures of Merit. Standard reference material may be physical material such as the Apollo core samples or material properties predicted for any landing site. The simulant provider is not restricted to providing a single "high fidelity" simulant, which may be costly to produce. The provider can now develop "lower fidelity" simulants for engineering applications such as drilling and mobility applications.

Rickman, Doug↗

Design and Materials of Reference Electrodes for Radioactive Waste Tank Service – A Literature Review

The Hanford site stores approximately 55 million gallons of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground, carbon steel storage tanks, 149 of these are single shell tanks (SSTs) and 28 of these are double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The DSTs have been in service for 38 to 56 years and current plans indicate that WTP operations will be completed in 2075. Thus, the tanks will need to remain in service far beyond the initial 40-year life expectancy. For life extension of the tanks, effective corrosion control practices must remain in force. This effort includes direct measurements of the extent of corrosion (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

A reference high-pressure CH4 adsorption isotherm for zeolite Y: results of an interlaboratory study

Abstract This paper reports the results of an international interlaboratory study led by the National Institute of Standards and Technology (NIST) on the measurement of high-pressure surface excess methane adsorption isotherms on NIST Reference Material RM 8850 (Zeolite Y), at 25 °C up to 7.5 MPa. Twenty laboratories participated in the study and contributed over one-hundred adsorption isotherms of methane on Zeolite Y. From these data, an empirical reference equation was determined, along with a 95% uncertainty interval ( U k =2 ). By requiring participants to replicate a high-pressure reference isotherm for carbon dioxide adsorption on NIST Reference Material RM 8852 (ZSM-5), this interlaboratory study also demonstrated the usefulness of reference isotherms in evaluating the performance of high-pressure adsorption experiments.

Nguyen, H. G. T. (ORCID:0000000210527565)↗

Radiochronometric analysis of an historic Cs-137 activity standard

In this work, a 137 Cs activity standard discovered during routine inventory was analyzed to determine its model age using radiochronometry. The aqueous activity standard was separated using an established separation method that employs commercially available Sr resin. The method was also tested against a nuclear forensics reference material developed specifically for benchmarking 137 Cs radiochronometry methods. Results of the analyses showed good agreement between the results and the certified values of the reference material. Analysis of the discovered activity standard were also in good agreement with the activity certification date, though uncertainty was higher due to natural Ba contaminating the sample and the stable 133 Cs used as a carrier during the standard’s production.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. International Electrotechnical Commission (IEC) test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 degrees C, 65 degrees C, 75 degrees C, or 85 degrees C), respectively. Characterizations were made using a UV-visible-near-infrared (UV-VIS-NIR) spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15-80 kJ mol-1, with an average of 48 kJ mol-1, similar to the average of 45 kJ mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

Clean Assembly of Genesis Collector Canister for Flight: Lessons for Planetary Sample Return

Measurement of solar composition in the Genesis collectors requires not only high sensitivity but very low blanks; thus, very strict collector contamination minimization was required beginning with mission planning and continuing through hardware design, fabrication, assembly and testing. Genesis started with clean collectors and kept them clean inside of a canister. The mounting hardware and container for the clean collectors were designed to be cleanable, with access to all surfaces for cleaning. Major structural components were made of aluminum and cleaned with megasonically energized ultrapure water (UPW). The UPW purity was >18 M resistivity. Although aluminum is relatively difficult to clean, the Genesis protocol achieved level 25 and level 50 cleanliness on large structural parts; however, the experience suggests that surface treatments may be helpful on future missions. All cleaning was performed in an ISO Class 4 (Class 10) cleanroom immediately adjacent to an ISO Class 4 assembly room; thus, no plastic packaging was required for transport. Persons assembling the canister were totally enclosed in cleanroom suits with face shield and HEPA filter exhaust from suit. Interior canister materials, including fasteners, were installed, untouched by gloves, using tweezers and other stainless steel tools. Sealants/lubricants were not exposed inside the canister, but vented to the exterior and applied in extremely small amounts using special tools. The canister was closed in ISO Class 4, not to be opened until on station at Earth-Sun L1. Throughout the cleaning and assembly, coupons of reference materials that were cleaned at the same time as the flight hardware were archived for future reference and blanks. Likewise reference collectors were archived. Post-mission analysis of collectors has made use of these archived reference materials.

Allton, J. H.↗

Modeling and Simulation Verification, Validation and Accreditation (VV&A): A New Undertaking for the Exploration Systems Mission Directorate

and Accreditation (VV&A) session audience, a snapshot review of the Exploration Space Mission Directorate s (ESMD) investigation into implementation of a modeling and simulation (M&S) VV&A program. The presentation provides some legacy ESMD reference material, including information on the then-current organizational structure, and M&S (Simulation Based Acquisition (SBA)) focus contained therein, to provide a context for the proposed M&S VV&A approach. This reference material briefly highlights the SBA goals and objectives, and outlines FY05 M&S development and implementation consistent with the Subjective Assessment, Constructive Assessment, Operator-in-the-Loop Assessment, Hardware-in-the-Loop Assessment, and In Service Operations Assessment M&S construct, the NASA Exploration Information Ontology Model (NExIOM) data model, and integration with the Windchill-based Integrated Collaborative Environment (ICE). The presentation then addresses the ESMD team s initial conclusions regarding an M&S VV&A program, summarizes the general VV&A implementation approach anticipated, and outlines some of the recognized VV&A program challenges, all within a broader context of the overarching Integrated Modeling and Simulation (IM&S) environment at both the ESMD and Agency (NASA) levels. The presentation concludes with a status on the current M&S organization s progress to date relative to the recommended IM&S implementation activity. The overall presentation was focused to provide, for the Verification, Validation,

Prill, Mark E.↗

Crystalline versus Glassy Nature of Iron Phosphate Waste Forms Subjected to Different Slow Cooling Curves

This report provides experimental details and associated results on the elemental distributions (compositions), crystalline/amorphous phase distributions, and microstructures for iron phosphate reference materials (DPF5-336) made with different cooling curves and starting from different temperatures (i.e., 1050°C and 1200°C). The primary goal of this work was to evaluate the properties of the DPF5- 336 reference material after it was melted and cooled at different rates to simulate the cooling profile of different types of canisters. Crystal fractions across the SCC#2, SCC#3, and SCC#5 samples were all similar ranging in crystal content of 35.66–41.14 mass% with amorphous fractions being the balance (64.34–58.86 mass%, respectively). This shows that the heat treatment profile did not seems to greatly affect either the total crystal content or the phase distributions. The quenched sample was almost completely amorphous (99.55 mass%) with very small peaks identified as Li 3 Fe 2 (PO 4 ) 3 whereas the SCC-treated materials showed peaks for what appear to be ten separate phases present in various concentrations. Another goal of these experiments was to see how the phase distribution affected chemical durability of these waste forms, but that information is being collected at Argonne National Laboratory and will be published in a separate report

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NIST Efforts to Quality-Assure Gunpowder Measurements

In the past few years, the National Institute for Standards and Technology (NIST) has been promoting the idea of quantitatively determining the additives in smokeless gunpowder using micellar capillary electrophoresis as a means of investigating the criminal use of hand guns and pipe bombs. As a part of this effort, we have evaluated both supercritical fluid and ultrasonic solvent extractions for the quantitative recovery of nitroglycerin (NG), diphenylamine (DPA), N-nitrosodiphenylamine (NnDPA), and ethyl centralite (EC) from gunpowder. Recoveries were evaluated by repeat extraction and matrix spiking experiments. The final extraction protocol provides greater than 95 percent recoveries. To help other researches validate their own analytical method for additive determinations, NIST is exploring the development of a standard reference material, Additives in Smokeless Gunpowder. The evaluated method is being applied to two double-base (NG-containing) powders, one stabilized with diphenylamine and the other with ethyl centralite. As part of this reference material development effort, we are conducting an interlaboratory comparison exercise among the forensic and military gunpowder measurement community.

MacCrehan, William A.↗