Search NASA⌕ Search

SEARCH · Search NASA

Results for “reflectance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Robust error calibration for serial crystallography

Serial crystallography is an important technique with unique abilities to resolve enzymatic transition states, minimize radiation damage to sensitive metalloenzymes and perform de novo structure determination from micrometre-sized crystals. This technique requires the merging of data from thousands of crystals, making manual identification of errant crystals unfeasible. cctbx.xfel.merge uses filtering to remove problematic data. However, this process is imperfect, and data reduction must be robust to outliers. We add robustness to cctbx.xfel.merge at the step of uncertainty determination for reflection intensities. This step is a critical point for robustness because it is the first step where the data sets are considered as a whole, as opposed to individual lattices. Robustness is conferred by reformulating the error-calibration procedure to have fewer and less stringent statistical assumptions and incorporating the ability to down-weight low-quality lattices. We then apply this method to five macromolecular XFEL data sets and observe the improvements to each. The appropriateness of the intensity uncertainties is demonstrated through internal consistency. This is performed through theoretical CC 1/2 and I /σ relationships and by weighted second moments, which use Wilson's prior to connect intensity uncertainties with their expected distribution. This work presents new mathematical tools to analyze intensity statistics and demonstrates their effectiveness through the often underappreciated process of uncertainty analysis.

Mittan-Moreau, David W.↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Advancements in reflected target nonintrusive assessment (ReTNA) for large optical surface measurement

Reflected computer vision targets are a powerful tool for measurement of mirror surface shape, with several important advantages over traditional fringe deflectometry methods. This method was first presented in 2021 and has undergone significant improvement and demonstration since. We describe a new baseline system using reflected computer vision targets, and present results from a large-scale measurement campaign conducted on both commercial heliostats and test mirrors in the laboratory. Calibration of the measurement system with photogrammetry allows for accurate measurement without careful control of target shape or camera position. Overall, the results show that a baseline setup using this method achieves measurement uncertainties in the slope error root-mean-square less than ±0.11 milliradian due to a series of repeatability conditions, varying sample position, rotation, lighting, camera settings, and system rebuild and recalibration. We present a detailed description of the setup, the results generated by this measurement tool, repeated measurement results, and the strengths and limitations of this metrology system.

14 SOLAR ENERGY↗

Electromagnetic Tomography of Radial Flow in the Quark-Gluon Plasma

We present a novel multimessenger approach to extract the effective radial flow of the quark-gluon plasma (QGP) by jointly analyzing thermal photon and dilepton spectra in heavy-ion collisions. A key feature of this method is that it circumvents the need for a directly unmeasurable reference—the photon temperature in the absence of flow—by establishing, within a calibrated model framework, a stable, approximately linear correlation with the dilepton-inferred temperature. This construction defines an experimentally constructible quantity, 𝑣$^{eff}_{𝑟}$, which reflects early-time collectivity and exhibits a strong correlation with the spacetime-averaged radial velocity of the QGP. Together with previous results linking dilepton slopes to the initial QGP temperature, our work establishes a consistent framework for electromagnetic tomography of the QGP. Here, our framework quantifies the experimental precision target, thereby providing a concrete road map for future measurements at RHIC and the LHC and opening a new avenue to probe the early-time dynamics of hot QCD matter.

Collective flow↗

Implementing a Laser Stabilization System for Trapping Ca+ Ions: an Internship Reflection

At Lawrence Livermore National Laboratory, I contributed to a project developing 3D printed micro ion traps for quantum computing. I designed, implemented, and assessed a laser stabilization system that locked lasers to the frequencies required for calibrating our High Finesse WS8-10 wavelength meter and for laser cooling and trapping of Ca+ ions. I also programmed a Python interface for hardware communication, data collection, and statistical analysis. Additionally, I optimized and aligned laser beam paths, and I implemented a closed digital feedback loop using Proportional, Integral, and Derivative (PID) control parameters. I analyzed both the long-term and short-term behavior of our locked lasers and adjusted PID parameters to enhance performance. Furthermore, I used COMSOL to simulate the capacitance of a linear Paul trap design and predict our trap’s performance. The procedures I developed for the interface, analysis, and simulations will continue to support the ion trapping experiment after my appointment. I strengthened my skills in data analysis, Python coding, and optical alignment for laser systems. My confidence as a researcher grew, particularly in communicating my research. This experience taught me the importance of careful planning and consideration in research and solidified my desire to continue exploring novel quantum technology as an undergraduate

42 ENGINEERING↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

The role of shale gas in shaping the U.S. long-run CO 2 emissions

The shale gas boom in the U.S. has lowered the U.S. CO 2 emissions in recent years mainly through substitution of gas for coal in power generation. Will the shale gas boom reduce the emissions in the long-run as well? To study this, we consider a counterfactual without the shale gas boom based on a general equilibrium modeling for the 2011 U.S. economy. To enhance the power sector modeling, the supply responses of coal-fired and gas-fired generations are calibrated to existing research. We find that if gas prices remain at 2007 levels in 2011, only a model setting that allows very little reduction in electricity demand, reflecting a short-run demand response, generates an increase in economy-wide emissions. For all other cases, the higher gas price under the counterfactual will have a dampening effect on economic activities and consequently lowers economy-wide emissions, even though the power sector emissions may increase due to the gas-to-coal switch. In other words, without any policy intervention, although the shale gas boom could reduce emissions in the short run, it may lead to higher emissions in the long run if the low gas prices persist. Our finding suggests that extrapolating the current decline in emissions due to the shale gas boom to the distant future could be misleading. Instead, if curbing emissions is the goal, rather than depending upon the cheap gas, policies and measures for cutting emissions remain imperative.

Chen, Y. -H. Henry↗

Vadose and Saturated Zone Flow and Transport Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This model package report (MPR) documents the development of the integrated vadose and saturated zone flow and transport model developed for the performance assessment of Trenches 31 and 34 in the low-level burial grounds (LLBGs). This modeling capability is intended for use in addressing the analysis requirements outlined in DOE O 435.1, Chg 1, Radioactive Waste Management1. The overall objective of the modeling effort is to provide a basis for making informed disposal decisions pertinent to Trenches 31 and 34. The purpose of the MPR is to document the development of the three-dimensional numerical vadose zone and saturated flow and transport model test case and evaluate its adequacy to support the LLBG performance assessment. The purpose is not to present results for DOE 435.1 decision making. The use of the model to perform base case and sensitivity analysis for the LLBG performance assessment, including inputs and results, is documented separately in subsequent environmental calculation files. This report discusses the development and translation of the conceptual model for flow and contaminant transport into the LLBG performance assessment three-dimensional numerical flow and transport model evaluated using the Subsurface Transport Over Multiple Phases (STOMP©) simulator. The development of representative geologic framework is described along with the implementation of waste release models used to represent contaminant release from waste disposed in the trenches. The report also provides the technical basis for specific model parameters and boundary conditions, along with description of modeling assumptions. This MPR includes certain calculations that are necessary to demonstrate the soundness of the model. Results provided by the model include vadose zone and saturated zone flow fields, and estimates of the possible future concentration in groundwater of technetium-99 and iodine-129 as example test cases. As an evaluation of the test cases, the model estimates of current vadose conditions are compared to available and analogous field and laboratory data, and compared to the results from the original performance assessment model (WHC-EP-0645, Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds 2 ). The features, events, and processes applicable to vadose zone and saturated zone flow and transport model are identified, and representative initial estimates for various parameters are documented. Note that the parameter estimates presented in this MPR are for illustration purposes, and may or may not reflect values selected for eventual performance assessment. Several key topical discussions (i.e., basis for recharge estimates, basis for vadose zone modeling, basis for saturated zone model development, and calibration) are included, which serve as the groundwork for confidence building for the groundwater pathway modeling and results. Numerical simulation results based on an example test case are included to illustrate the use of the combined saturated-unsaturated model in performance assessment calculations. Sensitivity and uncertainty results are not included in this MPR. Those results will be included in future environmental calculation files. The inclusion of the trapezoidal trench geometry and construction details in the finite difference grid introduces some gross simplifications regarding the trench and liner systems. The model test case presented in this MPR includes the assumption that the trench liner system does not affect flow through or around the trenches after the liner system is assumed to fail. This MPR also includes results of other test cases that involve alternate assumptions about how to incorporate the hydraulic effects of the trenches into the vadose zone of the model. These alternate cases do not attempt to account for the presence of the liner system after its assumed failure either. None of these cases is considered to be the base case at this time. Analysis and alternate cases that attempt to account for the presence of the liner system in greater detail, and its effect on flow through and around it, are to be documented in subsequent environmental calculation files. Depending on the results of those analyses and alternate cases, the eventual base case may involve more detailed inclusion of the effects of the liner system hydraulics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Persistent global greening over the last four decades using novel long-term vegetation index data with enhanced temporal consistency

Advanced Very High-Resolution Radiometer (AVHRR) satellite observations have provided the longest global daily records from 1980s, but the remaining temporal inconsistency in vegetation index datasets has hindered reliable assessment of vegetation greenness trends. To tackle this, we generated novel global long-term Normalized Difference Vegetation Index (NDVI) and Near-Infrared Reflectance of vegetation (NIRv) datasets derived from AVHRR and Moderate Resolution Imaging Spectroradiometer (MODIS). We addressed residual temporal inconsistency through three-step post processing including cross-sensor calibration among AVHRR sensors, orbital drifting correction for AVHRR sensors, and machine learning-based harmonization between AVHRR and MODIS. After applying each processing step, we confirmed the enhanced temporal consistency in terms of detrended anomaly, trend and interannual variability of NDVI and NIRv at calibration sites. Our refined NDVI and NIRv datasets showed a persistent global greening trend over the last four decades (NDVI: 0.0008 yr -1 ; NIRv: 0.0003 yr -1 ), contrasting with those without the three processing steps that showed rapid greening trends before 2000 (NDVI: 0.0017 yr -1 ; NIRv: 0.0008 yr -1 ) and weakened greening trends after 2000 (NDVI: 0.0004 yr -1 ; NIRv: 0.0001 yr -1 ). These findings highlight the importance of minimizing temporal inconsistency in long-term vegetation index datasets, which can support more reliable trend analysis in global vegetation response to climate changes.

54 ENVIRONMENTAL SCIENCES↗

Experimental determination of axion signal power of dish antennas and dielectric haloscopes using the reciprocity approach

The reciprocity approach is a powerful method to determine the expected signal power of axion haloscopes in a model-independent way. Especially for open and broadband setups like the MADMAX dielectric haloscope the sensitivity to the axion field is difficult to calibrate since they do not allow discrete eigenmode analysis and are optically too large to fully simulate. The central idea of the reciprocity approach is to measure a reflection-induced test field in the setup instead of trying to simulate the axion-induced field. In this article, the reciprocity approach is used to determine the expected signal power of a dish antenna and a minimal dielectric haloscope directly from measurements. The results match expectations from simulation but also include important systematic effects that are too difficult to simulate. In particular, the effect of antenna standing waves and higher order mode perturbations can be quantified for the first time in a dielectric haloscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standoff Detection of Oil and Powder Mixtures at 12 Meters Using a Tunable Quantum Cascade Laser-Based System with a Close Focus Telescope and Uncooled Infrared Detector

We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 μm (~1182 to 1000 cm –1 ) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO 2 ) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. Furthermore, the mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A leaf-level spectral library to support high-throughput plant phenotyping: predictive accuracy and model transfer

Abstract Leaf-level hyperspectral reflectance has become an effective tool for high-throughput phenotyping of plant leaf traits due to its rapid, low-cost, multi-sensing, and non-destructive nature. However, collecting samples for model calibration can still be expensive, and models show poor transferability among different datasets. This study had three specific objectives: first, to assemble a large library of leaf hyperspectral data (n=2460) from maize and sorghum; second, to evaluate two machine-learning approaches to estimate nine leaf properties (chlorophyll, thickness, water content, nitrogen, phosphorus, potassium, calcium, magnesium, and sulfur); and third, to investigate the usefulness of this spectral library for predicting external datasets (n=445) including soybean and camelina using extra-weighted spiking. Internal cross-validation showed satisfactory performance of the spectral library to estimate all nine traits (mean R2=0.688), with partial least-squares regression outperforming deep neural network models. Models calibrated solely using the spectral library showed degraded performance on external datasets (mean R2=0.159 for camelina, 0.337 for soybean). Models improved significantly when a small portion of external samples (n=20) was added to the library via extra-weighted spiking (mean R2=0.574 for camelina, 0.536 for soybean). The leaf-level spectral library greatly benefits plant physiological and biochemical phenotyping, whilst extra-weight spiking improves model transferability and extends its utility.

59 BASIC BIOLOGICAL SCIENCES↗

Status Quo of Heliostat Field Deployment Processes

Deployment of the solar field of a concentrating solar power plant is one of many factors that are integral to the success of a project. Knowledge transfer from outside the industry is limited due to the unique nature of heliostats, which redirect sunlight to a receiver with high precision while maintaining a high level of reflectivity. Moreover, learning from project to project can be limited due to the site-specific nature of projects, as the market includes several developers, each with their own unique design. In this paper, we discuss the state of the art in heliostat field deployment. We cover all the key aspects of deployment from project assessment to a fully functioning system, which include site selection, layout development, supply chain, assembly, site preparation and construction, calibration, and operations and maintenance.

concentrating solar power↗

Radiometric Standards and Best Practices: Recent Progress

International standards and best practices for solar resource assessments provide assurance for traceable measurements associated with a low uncertainty. This benefits the solar energy industry by reducing the investment risks through heightened confidence in the solar resource information. NREL, in collaboration with international organizations, such as subcommittees G03 of ASTM (Radiometry) and TC180/SC1 of ISO (Climate measurement and data), recently revised some standards that are widely used by the solar industry. These include radiometric standards that assist in (i) maintaining calibration traceability; (ii) uncertainty analysis; (iii) measurement quality assurance, and (iv) establishing reference spectral irradiance distributions. The latter are widely used by the solar community to evaluate the actual absorptance, reflectance, and transmittance of solar energy materials, or the performance of solar energy devices and systems, relative to standard conditions. This paper provides a summary of the recent changes brought to these standards as a way to better support the solar energy industry.

industries↗

Development of a hardened THz energy meter for use on the kilojoule-scale, short-pulse OMEGA EP laser

A highly adaptable and robust terahertz (THz) energy meter is designed and implemented to detect energetic THz pulses from high-intensity (>10 18 W/cm 2 ) laser–plasma interactions on the OMEGA EP. THz radiation from the laser driven target is detected by a shielded pyrometer. A second identical pyrometer is used for background subtraction. The detector can be configured to detect THz pulses in the 1 mm to 30 μm (0.3- to 10-THz) range and pulse energies from joules to microjoules via changes in filtration, aperture size, and position. Additional polarization selective filtration can also be used to determine the THz pulse polarization. The design incorporates significant radiation and electromagnetic pulse shielding to survive and operate within the OMEGA EP radiation environment. We describe the design, operational principle, calibration, and testing of the THz energy meter. The pyrometers were calibrated using a benchtop laser and show linear sensitivity to up to 1000 nJ of absorbed energy. Furthermore, the initial results from four OMEGA EP THz experiments detected up to ~15 μJ at the detector, which can correspond to hundreds of mJ depending on THz emission and reflection models.

47 OTHER INSTRUMENTATION↗

Improved Spectral Classification of Local K/M Dwarfs in SDSS Surveys. I. Chemodynamic Validation and Metallicity Calibration

An examination of 109,276 spectra of low-mass stars in the Sloan Digital Sky Survey (SDSS) data archive, collected pre-2010, provides a broad collection of K/M (sub)dwarfs tracing the local (d ≲ 250 pc) population of the thin-disk, thick-disk, and halo, based on 3D kinematics. These populations have distinct metallicities and kinematics, which should be reflected in lower-mass members. One complication is measuring metallicities of M dwarfs from low-resolution spectroscopy or photometry alone remains a challenge, even with the availability of Gaia data. To better characterize physical parameters of low-mass stars observed by SDSS, we define a set of 536 improved, empirical K/M dwarf classification templates to more accurately determine spectral subtypes (K5.5–M8.5) and morphology classes (MCs) (0.5–12.5). We select the best-fit template to every archival SDSS spectrum in the range 5000–8000 Å based on minimum χ 2 value. We then use secondary metallicity estimators to calibrate the most likely [Fe/H] values corresponding to the assigned MC. We confirm that the most metal-rich K/M dwarfs have thin-disk kinematics, and we observe the known effect of Galactic radial metallicity migration, which we confirm is strongly imprinted in the chemodynamics of the local disk M dwarfs. Confirmation of these chemodynamic trends validates the precision of our improved templates for estimating [Fe/H] for M (sub)dwarfs, notably at the low-metallicity end (–3 < [Fe/H] < –1). Substructure in the chemodynamics of the most metal-poor K/M subdwarfs begins to distinguish between local Gaia-Enceladus and local in situ halo objects. This methodology opens the door to use the ubiquitous, local K/M (sub)dwarfs to trace local Galactic chemodynamics with the highest possible resolution.

79 ASTRONOMY AND ASTROPHYSICS↗