Search NASA⌕ Search

SEARCH · Search NASA

Results for “refrigerants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Hydride absorption refrigerator system for ten Kelvin and below

A very long-life, lightweight and efficient hydride absorption refrigerator system was built to operate at ten Kelvin and below. The system consists of four basic stages of refrigeration. The first stage is accomplished by an active refrigeration system. The second stage is operated by a hydride absorption system, wherein a heated hydride powder drives off high pressure hydrogen through a Joule-Thomson/heat exchanger expansion loop such that the hydrogen is partially liquefied. In the third stage, the vapor pressure over the collected liquid hydrogen is lowered by absorbing the hydrogen vapor onto a different low pressure, worn hydride. With a 1.7 torr partial pressure of hydrogen gas in the hydride, liquid hydrogen is solidified and sublimes at 10 K. Long-life adiabatic demagnetization refrigerators, helium desorption, or helium diaphragm compressors are used to cool to 4 K or below. It is shown that the hydride concepts provide an extremely efficient means of refrigeration to 10 K, and that an entire sorption refrigeration process can be accomplished solely by using low grade heat energy at about 150 C.

Jones, J. A.↗

Thermoacoustic refrigeration

A new refrigerator which uses resonant high amplitude sound in inert gases to pump heat is described and demonstrated. The phasing of the thermoacoustic cycle is provided by thermal conduction. This 'natural' phasing allows the entire refrigerator to operate with only one moving part (the loudspeaker diaphragm). The thermoacoustic refrigerator has no sliding seals, requires no lubrication, uses only low-tolerance machine parts, and contains no expensive components. Because the compressor moving mass is typically small and the oscillation frequency is high, the small amount of vibration is very easily isolated. This low vibration and lack of sliding seals makes thermoacoustic refrigeration an excellent candidate for food refrigeration and commercial/residential air conditioning applications. The design, fabrication, and performance of the first practical, autonomous thermoacoustic refrigerator, which will be flown on the Space Shuttle (STS-42), are described, and designs for terrestrial applications are presented.

Garrett, Steven L.↗

Conceptual design of a 0.1 W magnetic refrigerator for operation between 10 K and 2 K

The design of a magnetic refrigerator for space applications is discussed. The refrigerator is to operate in the temperature range of 10 K-2 K, at a 2 K cooling power of 0.10 W. As in other magnetic refrigerators operating in this temperature range GGG has been selected as the refrigerant. Crucial to the design of the magnetic refrigerator are the heat switches at both the hot and cold ends of the GGG pill. The 2 K heat switch utilizes a narrow He II filled gap. The 10 K heat switch is based on a narrow helium gas gap. For each switch, the helium in the gap is cycled by means of activated carbon pumps. The design concentrates on reducing the switching times of the pumps and the switches as a whole. A single stage system (one magnet; one refrigerant pill) is being developed. Continuous cooling requires the fully stationary system to have at least two stages running parallel/out of phase with each other. In order to conserve energy, it is intended to recycle the magnetic energy between the magnets. To this purpose, converter networks designed for superconducting magnetic energy storage are being studied.

Helvensteijn, Ben P. M.↗

High-Performance, Low Environmental Impact Refrigerants

Refrigerants used in process and facilities systems in the US include R-12, R-22, R-123, R-134a, R-404A, R-410A, R-500, and R-502. All but R-134a, R-404A, and R-410A contain ozone-depleting substances that will be phased out under the Montreal Protocol. Some of the substitutes do not perform as well as the refrigerants they are replacing, require new equipment, and have relatively high global warming potentials (GWPs). New refrigerants are needed that addresses environmental, safety, and performance issues simultaneously. In efforts sponsored by Ikon Corporation, NASA Kennedy Space Center (KSC), and the US Environmental Protection Agency (EPA), ETEC has developed and tested a new class of refrigerants, the Ikon (registered) refrigerants, based on iodofluorocarbons (IFCs). These refrigerants are nonflammable, have essentially zero ozone-depletion potential (ODP), low GWP, high performance (energy efficiency and capacity), and can be dropped into much existing equipment.

McCullough, E. T.↗

Floating Pressure Conversion and Equipment Upgrades of Two 3.5kw, 20k, Helium Refrigerators

Two helium refrigerators, each rated for 3.5KW at 20K, are used at NASA s Johnson Space Center (JSC) in Building No. 32 to provide cryo-pumping within two large thermal-vacuum chambers. These refrigerators were originally commissioned in 1996. Equipment refurbishment and upgrades to the controls of these refrigerators were recently completed. This paper describes some of the mechanical and control issues that necessitated the equipment refurbishment and controls change-over. It will describe the modifications and the new process control which allows the refrigerators to take advantage of the Ganni Cycle "floating pressure" control technology. The upgrades -- the controls philosophy change-over to the floating pressure control technology and the newly refurbished equipment -- have greatly improved the performance, stability, and efficiency of these two refrigerators. The upgrades have also given the operators more information and details about the operational status of the main components (compressors, expanders etc.) of the refrigerators at all operating conditions (i.e.: at various loads in the vacuum chambers). Capabilities, configuration, and performance data pre, and post, upgrading will be presented.

Homan, Jonathan↗

Development of a Battery-Free Solar Refrigerator

Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

Ewert, Michael K.↗

Improving Control in a Joule-Thomson Refrigerator

A report discusses a modified design of a Joule-Thomson (JT) refrigerator under development to be incorporated into scientific instrumentation aboard a spacecraft. In most other JT refrigerators (including common household refrigerators), the temperature of the evaporator (the cold stage) is kept within a desired narrow range by turning a compressor on and off as needed. This mode of control is inadequate for the present refrigerator because a JT-refrigerator compressor performs poorly when the flow from its evaporator varies substantially, and this refrigerator is required to maintain adequate cooling power. The proposed design modifications include changes in the arrangement of heat exchangers, addition of a clamp that would afford a controlled heat leak from a warmer to a cooler stage to smooth out temperature fluctuations in the cooler stage, and incorporation of a proportional + integral + derivative (PID) control system that would regulate the heat leak to maintain the temperature of the evaporator within a desired narrow range while keeping the amount of liquid in the evaporator within a very narrow range in order to optimize the performance of the compressor. Novelty lies in combining the temperature- and cooling-power-regulating controls into a single control system.

Borders, James↗

Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗

Surface acoustic wave sensor for refrigerant leakage detection

A SAW sensor is optimized for detection of refrigerant leakage in a refrigerant system or other gases, vapors, explosives or chemicals of interest. The SAW sensor includes a piezoelectric substrate; an interdigitated transducer deposited on the piezoelectric substrate, the interdigitated transducer having an input portion that receives input surface acoustic waves and an output portion that emits output surface acoustic waves; and a refrigerant sensor film located between the input portion and the output portion of the interdigitated transducer, the refrigerant sensor film including a sorbent material that is selected for preferential adsorption of a target refrigerant over atmospheric gases. Adsorption of the target refrigerant by the sorbent material results in a frequency shift of a frequency of the output surface acoustic waves relative to a frequency of the input surface acoustic waves. The sorbent material may be a metal organic framework (MOF) material, a covalent organic framework (COF) material, a porous organic cage or organic macrocyles such as calix [n] arene and its related derivatives.

Kunapuli, Raghuit Prasad↗

Multi-stage heat pump with two-phase injection for cold climate applications implementing natural refrigerants

Heat pump adoption in cold climates is limited by various technical challenges, including heat capacity degradation, compressor deterioration, and frost accumulation on the outdoor heat exchanger. Furthermore, wide-spread adoption of heat pumps with high global warming potential presents a possible environmental concern. Thus, we present a heat pump concept termed the “saturation cycle,” which uses numerous compression stages to improve energy efficiency and injects two-phase refrigerant between compression stages to dramatically reduce compressor discharge temperatures. Given the growing interest in heat pumps, there is a need for a straightforward framework for parametric evaluation of natural refrigerants in high-efficiency heat pump cycle architectures, like the saturation cycle, in adverse climates. This work develops a thermodynamic modeling framework and focuses on the application of natural refrigerants to explore the performance trends at extremely cold climates down to −25 °C. This study shows that a two-stage saturation cycle and four-stage saturation cycle can reduce the compressor discharge superheating by up to 51–57 % or 73–80 %, respectively, depending on the refrigerant. Furthermore, at −25 °C, a two-stage R-290 saturation cycle heat pump theoretically can use 25 % less power than a single-stage heat pump or can provide up to 59 % more heating capacity when using the same compressor power as the baseline single-stage heat pump. The exergetic parametric analyses show that two-phase refrigerant injection fundamentally improves the thermodynamic performance of the heat pump, reducing overall exergy destruction by 10 % compared to a vapor-injection heat pump, compared at −25 °C. Thus, the saturation cycle is a promising heat pump cycle architecture for cold climate applications due to its superior energy savings (or capacity improvement) and substantial de-superheating capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

In tube condensation of low global warming potential refrigerants in an axial micro-fin aluminum tube

Environmental regulations have driven the development of refrigerants with low global warming potential (GWP). To design heat exchangers using these new refrigerants, data are needed concerning the heat transfer coefficient and pressure drop in two-phase flow. Another change is the increasing use of aluminum tubes rather than copper tubes to reduce heat exchanger cost. Hence, this study presents an experimental investigation of flow condensation using an expanded axial micro-fin aluminum tube with a fin-tip diameter of 5.96 mm. Here, the experiments included single compounds R-32, R-1234yf, and R-1234ze(E), zeotropic mixtures with low glide (R-454B), and zeotropic mixtures with high-glide (R-454C and R-455A). Experiments were conducted at condensation temperatures ranging from 40 °C to 50 °C, reduced pressures ranging from 0.21 to 0.55, and mass fluxes ranging from 150 to 350 kg/(m 2 s). Data obtained for these refrigerants constitute one of the first reports for high-glide refrigerants using axial micro-fin aluminum tubes. An evaluation of heat transfer degradation of zeotropic mixtures due to mass transfer resistance at the liquid/vapor interface is presented. This information can be used to design heat exchangers for next generation air conditioning and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings

The Guide for Creating a Building-Level Action Plan to Manage Refrigerants in Buildings has been developed in response to stakeholder feedback and interest received during the Better Buildings Managing Refrigerants Working Group. This guide includes best practices and a step-by-step guide to create a plan to manage their organization's refrigerants. Stakeholders were interested in guidance for refrigerant management to help reduce costs and protect efficiency of equipment, to mitigate risk related to increased maintenance and operational budgets, and to manage costs of using legacy refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Sensing Technologies for New, Low Global Warming Potential (GWP), Flammable Refrigerants

Commercial refrigeration systems currently utilize refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The advent of low GWP alternatives (GWP <150) is expected to significantly curtail direct emissions from this segment and greatly influence the ongoing electrification and decarbonization efforts. Most of the low GWP alternatives exhibit flammability risk and hence require robust sensing solutions for a reliable and safe operation of the equipment. This review article aims to provide an overview of different sensing mechanisms suitable for potential applications in systems employing flammable refrigerants, particularly those designated as A2L class. A summary of different A2L refrigerants and their properties is provided followed by a broad review of different classes of sensors, their working principle, transduction method, features, advantages, and limitations. Additionally, key performance characteristics of accuracy, selectivity, sensitivity, dynamic characteristic, and durability among other properties are discussed. Finally, areas of improvement and corresponding approaches are suggested for potential sensors in the successful adoption of A2L class refrigerants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of Thermal Energy Storage Integration Strategy on System Performance and Refrigerant Charge for Small-Scale R290 Heat Pumps

As small-scale (2.5 – 5 kW) heat pumps across the US increase straining the grid during peak hours, integrated heat pump thermal energy storage (HP-TES) systems can assist by load shifting. However, challenges arise when assembling these systems, as direct refrigerant-phase change material (PCM) heat exchangers (HXs) increase refrigerant charge, and indirect secondary loops degrade HP-TES performance. In this work, direct and indirect HP-TES configurations were sized using commercially available HXs to compare the available load shift time and performance at similar refrigerant charges. For the same indirect 5 kW HP-TES refrigerant charge, directly HP-TES can operate up to 72 and 145 minutes in cooling and heating modes, respectively, using small diameter tubes. Using Modelica, COP increases for direct and indirect HP-TES were 22% and 9%, respectively, given the parasitic losses in the indirect HP-TES. Overall, small-scale direct HP-TES can have comparable refrigerant charges with indirect HP-TES maximizing COP improvements.

25 ENERGY STORAGE↗

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗