Search NASASearch

SEARCH · Search NASA

Results for “regolith simulant testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,198 records · Page 5

Characterization of the Mechanical Trash Compactor Bag Removal Force

Managing trash accumulation is a critical challenge in human space explorations since the trash volume and mass can significantly influence launch cost and operational efficiency. This study aids the development of a Mechanical Trash Compactor (Mpactor) by testing the removal force required to remove a “trash bag” from the Mpactor. To do this, a Pneumatic Pressure Mandrel System was designed to simulate the normal force trash would exerts on the trash bag and subsequently the sidewalls of the Mpactor. For various levels of sidewall normal force, the removal force required to remove the simulated trash bag from the Mpactor compaction chamber was measured. This testing is used to identify optimal bag materials. Additionally, testing was done on both the native stainless steel walls of the compaction chamber as well as the walls after being Teflon lined. Split-plot ANOVA, simple main effects analysis, Holm’s post hoc comparisons for interaction, and sensitivity analyses were conducted to assess the influence of trash bag and sidewall materials on the required removal force. It was found that Teflon reduced the force required to remove the trash bag as well as reduced material-dependent variation in removal force. Testing showed that Teflon reduced the required removal force with a Polyvinylidene Fluoride , an unidentified Ethylene acrylate - Low Density Polyethylene copolymer, and a Polyvinyl Chloride all requiring significantly less removal force than the other materials tested.

pressure mandrel

Hubble Space Telescope nickel-hydrogen battery testing: An update

The Marshall Space Flight Center (MSFC) began testing the HST Ni-H2 Six Battery Test and the 'Flight Spare Battery' Tests approximately one year before the launch of the HST. These tests are operated and reported on by the MSFC, but are managed and funded by Goddard Space Flight Center in direct support of the HST program. The HST Ni-H2 batteries are built from Eagle Picher RNH-90-3 cells. The HST EPS (electrical power system) is a direct energy transfer power system. The HST Ni-H2 Six Battery Test is a breadboard of the HST EPS. The batteries in the test are composed of test module cells and packaged into three battery modules identical to the flight modules. This test is the HST EPS testbed. The 'Flight Spare Battery' Test is a simulation of one of the six battery channels on the HST. The cells in the test are from the flight spare lot of cells, which are the same lot of cells that three of the six HST flight batteries are made from. This test is the battery life test for the HST program.

Whitt, Thomas H.

The 60-MW Shuttle Interaction Heating Facility

An arc-heated wind-tunnel system described in the present paper will simulate aerodynamic heating in large-scale tests of the thermal protection system of the Shuttle Orbiter Vehicle during entry. The system provides for large-scale subsystem tests in high-enthalpy streams with boundary layer flows at high Reynolds numbers and for large test-body sizes in stagnation flows. The discussion covers the design concept of the arc-jet systems, the extensive hardware developments of the arc heater to provide reliable operation, and verification and performance measurements of the system's operating envelopes.

W Winovich

Nickel cadmium battery performance modelling

The development of a model to predict cell/battery behavior given databases of temperature is described. The model accommodates batteries of various structural as well as thermal designs. Cell internal design modifications can be accommodated as long as the databases reflect the cell's performance characteristics. Operational parameters can be varied to simulate any number of charge or discharge methods under any orbital regime. The flexibility of the model stems from the broad scope of input variables and allows the prediction of battery performance under simulated mission or test conditions.

Clark, K.

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

Michael Lewandowski

SERFE Ground Unit EVA Series After Three Year Spacesuit Stowage Period

NASA’s spacesuit government reference design for returning to the Moon is called the Exploration Extravehicular Mobility Unit (xEMU). The xEMU subassembly that provides life support, such as oxygen and thermal control, is the Portable Life Support System (PLSS). Inside the PLSS is a new technology that NASA wanted to test to provide cooling to the crew during EVAs (ExtraVehicular Activity). This technology is called the Spacesuit Water Membrane Evaporator (SWME). In order to test SWME in an improved thermal control loop (TCL) both on Earth and in Space, the Spacesuit Evaporation Rejection Flight Experiment (SERFE) was created. The Ground unit, or testbed at Johnson Space Center (JSC), tested the cooling technology in Earth’s gravity, while the Flight unit, or payload on the International Space Station (ISS), tested the cooling technology in micro-gravity. Since fluids flow differently in micro-gravity, testing in both environments would provide important data for improving cooling performance during EVAs. Both units completed 25 simulated EVAs with the same settings so SWME performance on the ground could be compared to the ISS. The Flight unit was completed first and performed EVAs on the ISS between 2020 and 2022. The Ground unit performed EVAs between 2021 and 2022. When the Flight unit came back from the ISS, it was taken apart for analysis. This analysis looked at how well SWME was able to maintain its heat rejection capability after various dwell times, such as a 90 day Airlock Coolant Loop Recovery (ALCLR) cycle, when the Extravehicular Mobility Unit (EMU) currently on the ISS would normally need maintenance. After a three year simulated spacesuit dwell, the Ground unit performed another EVA series in 2025 to test SWME’s shelf life. The results from this test series will inform mission planning as NASA plans to go back to the Moon and beyond.

SWME

Ice in Convective Storm Environments: Assessing Impacts of Microphysics on Simulated Reflectivities

Satellite radar retrievals of clouds and precipitation rely on assumptions about the microphysical properties of hydrometeors such as particle size distributions (PSDs) and massdimensional relationships, which have been shown to vary in distinct environments. A deeper understanding of linkages between mass-dimensional relationships, ice crystal shape, and radar reflectivities across cloud and precipitation regimes is necessary for developing new retrievals for upcoming satellite radar missions, including the INvestigation of Convective UpdraftS (INCUS), as well as future missions that will feature space-borne radars observing clouds, convection, and precipitation. This study investigates ice microphysical characteristics through aircraft in-situ and remote sensing observations from two convective events during the Mid-latitude Continental Convective Clouds Experiment (MC3E) in the Southern Great Plains, and tests implications for ice particle habit in forward modeled radar observations. During MC3E, the Ka/Ku- band High Altitude Imaging Wind and Rain Airborne Profiler (HIWRAP) was onboard the NASA ER-2 aircraft, while in-situ measurements were taken onboard the University of North Dakota Citation. In-situ PSDs and particle shape information from optical array probe data are used to forward model radar reflectivities from particle scattering databases and are compared against HIWRAP reflectivities. Various particle combinations can be used to find agreement with HIWRAP observations, and the forward modeled reflectivities were sensitive to particle type. Varying the riming on the aggregate and graupel particles resulted in larger than 10 dB differences in reflectivities. The in-situ and radar observations imply the occurrence of aggregation, size sorting and lofting particles.

Julia A. Shates

Assembly and Integration Status of a High Fidelity Ground Test Bed for the Water Processor Assembly

The Water Recovery System (WRS) is a critical component of life support aboard the International Space Station (ISS) and will play an essential role in future missions beyond Low Earth Orbit (LEO). Its primary functional units – the Urine Processor Assembly (UPA), Brine Processor Assembly (BPA), and Water Processor Assembly (WPA) – must be evaluated for extended operation, dormancy resilience, material obsolescence, and reliability under exploration-driven constraints. Ground testing is vital for developing these technologies and generating statistically relevant reliability assessments, which requires extended runtime under integrated, Flight-like conditions. Currently, no high-fidelity, fully integrated WPA ground test bed exists to support these objectives. To address this gap, NASA is developing a WPA test bed at Marshall Space Flight Center (MSFC) that combines downgraded ISS flight hardware with functionally flight-like components in a cost-effective configuration while maintaining priority hardware investigations. This paper describes the current status of hardware assembly and integration, outlines key challenges such as simulating microgravity effects and mitigating obsolescence, and presents future test objectives including software development, reliability assessments, dormancy studies, and exploration-oriented upgrades.

Water Processor Assembly

Exploration Extravehicular Mobility Unit 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert Marsch

Assembly and Integration Status of a High Fidelity Ground Test Bed for the Water Processor Assembly

The Water Recovery System (WRS) is a critical component of life support aboard the International Space Station (ISS) and will play an essential role in future missions beyond Low Earth Orbit (LEO). Its primary functional units – the Urine Processor Assembly (UPA), Brine Processor Assembly (BPA), and Water Processor Assembly (WPA) – must be evaluated for extended operation, dormancy resilience, material obsolescence, and reliability under exploration-driven constraints. Ground testing is vital for developing these technologies and generating statistically relevant reliability assessments, which requires extended runtime under integrated, Flight-like conditions. Currently, no high-fidelity, fully integrated WPA ground test bed exists to support these objectives. To address this gap, NASA is developing a WPA test bed at Marshall Space Flight Center (MSFC) that combines downgraded ISS flight hardware with functionally flight-like components in a cost-effective configuration while maintaining priority hardware investigations. This paper describes the current status of hardware assembly and integration, outlines key challenges such as simulating microgravity effects and mitigating obsolescence, and presents future test objectives including software development, reliability assessments, dormancy studies, and exploration-oriented upgrades.

Mary-Elizabeth Davis

Spacecraft Fire Safety Predictions using Verified Saffire Model

A model developed using Fire Dynamics Simulator (FDS) that aimed to determine the effect of a fire in a spacecraft was validated by data collected during the Saffire campaign. The model used inlet and outlet temperatures and CO 2 concentrations of the Saffire payload where fire spread was taking place to determine the amount of heat and combustion products that made it into Northrop Grumman’s Cygnus vehicle. The model was then validated using six remote sensors in various places in the vehicle, as well as a far field device (FFD) in the open zenith section that was representative of average vehicle values. The current work focuses on using the model to predict fire safety scenarios. One simulation aimed to determine the fate of HCl, which sticks to surfaces. The model prediction showed that the HCl was removed from the atmosphere rapidly. This compared well against the FFD data in the Saffire VI campaign event where a bottle of 5% HCl was released into the vehicle. An additional simulation where the Environmental Control and Life Support System (ECLSS) was shut off once the FFD reached 5 ppm of HCl showed that HCl stayed in the atmosphere considerably longer. Continuing the simulation with the ECLSS activated and after temperatures returned to their initial conditions, resulted in a rapid removal of HCL similar to that observed in the original HCl release scenario model. Finally, a simulation that used the heat release rate from a lithium-ion battery test to determine the effect it would have on a spacecraft was performed. This simulation used a heat addition rate that is considerably higher than what was determined from the burning of solid fuels in the Saffire campaign and hence produced a non-trivial temperature increase in more locations within the vehicle.

Fire Safety

Exploration Extravehicular Mobility Unit (xEMU) 11 Foot Vacuum Chamber Upgrades Test Results

The Exploration Extravehicular Mobility Unit (xEMU) uncrewed 11 foot vacuum chamber testing evaluated the capabilities of the 11 foot vacuum chamber facility to support advanced spacesuit testing. The government reference design xEMU spacesuit provided a high-fidelity test article to demonstrate 11 foot vacuum chamber capabilities which included: gas loading of the chamber at varying simulated metabolic rates and open loop suit abort operations, Intravehicular Activity (IVA) vacuum access, consumables recharge, IVA vehicle-provided thermal loop cooling, and IVA vehicle-provided power. To demonstrate the xEMU airlock operations transitioning from IVA to EVA conditions without a test subject in the suit, test support equipment was developed to remotely actuate both the Exploration, Servicing, and Cooling Umbilical (ESCU) and the vacuum access umbilical. This test also evaluated the performance of the Exploration Portable Life Support System (xPLSS) at vacuum conditions. Data was collected and analyzed for carbon dioxide (CO2) scrubbing performance of the Rapid Cycle Amine (RCA) swingbed, for thermal regulation performance of the Suit Water Membrane Evaporator (SWME), and for sensor performance across the xPLSS. This paper will detail the findings of the testing performed with these upgrades which discussed previously laid out in ICES-2025-342.

Robert F Marsch

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This paper describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

electrified aircraft propulsion

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This presentation describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

electrified aircraft propulsion

Preliminary Dynamic Modeling of the Quarter-Scale Distributed Electric Propulsion Aircraft

This paper describes the early-stage modeling of a quarter-scale distributed electric propulsion aircraft, based on the SUbsonic Single Aft eNgine (SUSAN) Electrofan, a transformative concept aircraft for which a model exists. The full-scale 180 passenger SUSAN concept has a single turbofan engine in the tail that both produces thrust and provides electrical power to 16 electric fans distributed across the wings utilizing a series/parallel hybrid architecture. The quarter-scale version would have an internal combustion piston engine to provide power to 17 electric fans–16 on the wings, one in the tail–in a series hybrid configuration, and no vertical or horizontal stabilizers. It would also have a reduced flight envelope in terms of both altitude and speed. The initial modeling approach is to scale down the original airframe model to capture the dynamic behavior of a much smaller aircraft, albeit with an empennage. The original powertrain model is then replaced with one representing the physical components of that of the quarter-scale vehicle. This powertrain model is suitable for control design and analysis, and the fully integrated, although preliminary, aircraft model allows flight simulator testing and evaluation. Results from simulations are presented.

Electrified powertrain

Nickel-hydrogen battery state of charge during low rate trickle charging

Battery temperature increase, due to low rate trickle charging, has been determined experimentally, using a six cell battery module in a test setup simulating the anticipated AXAF-1 prelaunch environment. Test results indicate trickle charge rates less than or equal to the self discharge rate do not increase dissipation beyond that due to the self discharge. Significant trickle charge rates (approximately C/500) result in battery temperatures only a few degrees (F) higher than those observed during periods of open circuit stand.

Lurie, C.

MEAD In-situ Sampling and Testing at Haughton Crater

The Mars Exploration through Analog-site Drilling (MEAD) project is designed to demonstrate the feasibility and scientific value of robotic drilling missions to Mars in the search for evidence of past or extant life. MEAD conducts high-fidelity field simulations integrating drilling, autonomous operations, and in-situ life-detection and mineralogical instruments. The project tests the Signs of Life Detector (SOLID), proposed for the 2019 Discovery Mars Icebreaker mission, and ARIA (Astronaut Raman Instrument for ISRU and Astrobiology), which provides mineral identification and detects trace organics and volatiles, including indicators of organic thermal maturity. Because current and planned Mars drilling missions operate largely “blind,” MEAD also evaluates the use of drill-induced vibrations recorded by deployed geophones to enable local subsurface mapping for improved targeting of drilling and sampling. In August 2025, MEAD completed its first-year field deployment to Haughton Crater in the Canadian High Arctic, an established Mars impact-crater terrestrial analog site, bringing a Honeybee Robotics TRIDENT drill with applied automation, alongside ARIA, SOLID, and FleetSpace geophones.

Haughton Crater