Search NASA⌕ Search

SEARCH · Search NASA

Results for “resolution test pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Verifying infectious disease scenario planning for geographically diverse populations

In the face of the COVID-19 pandemic, the literature saw a spike in publications for epidemic models, and a renewed interest in capturing contact networks and geographic movement of populations. There remains a general lack of consensus in the modeling community around best practices for spatiotemporal epi-modeling, specifically as it pertains to the infection rate formulation and the underlying contact or mixing model. We mathematically verify several common modeling assumptions in the literature, to prove when certain choices can provide consistent results across different geographic resolutions, population densities and patterns, and mixing assumptions. The most common infection rate formulation, a computationally low cost per capita infection rate assumption, fails the consistency tests for heterogeneous populations and gravity-weighting assumptions. Future modeling efforts in spatiotemporal disease modeling should be wary of this limitation, particularly when working with more heterogeneous or sparse populations. Our results provide guidance for testing that a model preserves desirable properties even when model inputs mask potential problems due to symmetry or homogeneity. We also provide a recipe for performing this type of verification, strengthening decision support tools.

59 BASIC BIOLOGICAL SCIENCES↗

Hartmann characterization of the PEEM-3 aberration-corrected X-ray photoemission electron microscope

Aberration correction by an electron mirror dramatically improves the spatial resolution and transmission of photoemission electron microscopes. We will review the performance of the recently installed aberration corrector of the X-ray Photoemission Electron Microscope PEEM-3 and show a large improvement in the efficiency of the electron optics. Hartmann testing is introduced as a quantitative method to measure the geometrical aberrations of a cathode lens electron microscope. Here, we find that aberration correction leads to an order of magnitude reduction of the spherical aberrations, suggesting that a spatial resolution of below 100 nm is possible at 100% transmission of the optics when using x-rays. We demonstrate this improved performance by imaging test patterns employing element and magnetic contrast.

36 MATERIALS SCIENCE↗

MTF analysis of LANDSAT-4 Thematic Mapper

The spatial radiance distribution of a ground target must be known to a resolution at least four to five times greater than that of the system under test when measuring a satellite sensor's modulation transfer function. Calibration of the target requires either the use of man-made special purpose targets with known properties, e.g., a small reflective mirror or a dark-light linear pattern such as line or edge, or use of relatively high resolution underflight imagery to calibrate an arbitrary ground scene. Both approaches are to be used in addition a technique that utilizes an analytical model for the scene spatial frequency power spectrum is being investigated as an alternative to calibration of the scene.

Schowengerdt, R.↗

MTF Analysis of LANDSAT-4 Thematic Mapper

The spatial radiance distribution of a ground target must be known to a resolution at least four to five times greater than that of the system under test when measuring a satellite sensor's modulation transfer function. Calibration of the target requires either the use of man-made special purpose targets with known properties, e.g., a small reflective mirror or a dark-light linear pattern such as line or edge, or use of relatively high resolution underflight imagery to calibrate an arbitrary ground scene. Both approaches are to be used, in addition a technique that utilizes an analytical model of the scene spatial frequency power spectrum is being investigated as an alternative to calibration of the scene.

Schowengerdt, R.↗

The Use of Geomorphometrics for Geologic Site Characterization

The Problem: Developing an accurate geologic site characterization is difficult for denied-access sites. A good understanding of the geology (both in terms of the rock types and the fracture networks) is required for event evaluation (e.g., modulation of seismic signals from the source), planning of treaty monitoring sensors (fracture play a key role in the gas migration pathways), and evaluation of containment strategies. The Hypothesis: Quantitative analysis of terrain characteristics provides a way to relate the topography (easily obtained at high resolution) to surface geology. The Method: Integration of Terrain Complexity Index (TCI, derived from surface roughness) with drainage patterns and texture to produce a "predicted" geologic map. The viability of this method was evaluated by applying the algorithm to an area of know geology (Area 15 at the Nevada Test Site - NNSS). A 10-meter digital elevation model (DEM) was used for this evaluation. The Application: We have demonstrated the utility of this method by developing an improved surface geologic map for the North Korean Test Site using a 5-meter DEM. Why Now: Improved geologic characterization of potential nuclear test sites in a number of countries is needed for a number of Nonproliferation objectives. What's Needed Next: 1) A more robust and automated interpretation algorithm for the drainage analysis aspect; 2) improved data fusion of the TCI with drainage patterns; and 3) evaluation of the potential for fracture mapping in granite using a very high resolution DEM at the NNSS site (a 1-meter DEM in on order).

58 GEOSCIENCES↗

Ga lithography in sputtered niobium for superconductive micro and nanowires

This work demonstrates the use of focused ion beam (FIB) implanted Ga as a lithographic mask for plasma etching of Nb films. Using a highly collimated Ga beam of a FIB, Nb is implanted 12 nm deep with a 14 nm thick Ga layer providing etch selectivity better than 15:1 with fluorine based etch chemistry. Implanted square test patterns, both 10 μm by 10 μm and 100 μm by 100 μm, demonstrate that doses above than 7.5 × 10{sup 15 }cm{sup −2} at 30 kV provide adequate mask protection for a 205 nm thick, sputtered Nb film. The resolution of this dry lithographic technique is demonstrated by fabrication of nanowires 75 nm wide by 10 μm long connected to 50 μm wide contact pads. The residual resistance ratio of patterned Nb films was 3. The superconducting transition temperature (T{sub c}) = 7.7 K was measured using a magnetic properties measurement system. This nanoscale, dry lithographic technique was extended to sputtered TiN and Ta here and could be used on other fluorine etched superconductors such as NbN, NbSi, and NbTi.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

pvplr-python: Python package implementation of PVplr for Performance Loss Rate (PLR) analysis

Due to software fragmentation, PV system modeling teams can be limited to language specific packages, preventing cross-sectional analysis of different modeling techniques and workflows. To this end, PVplr, a popular PV performance modeling R software package, has been ported to the Python programming language. To verify and test the robustness of the port, NSRDB data has been used to simulated PV installations at native resolution (~2 million Sites), with a variety of degradation rates, degradation patterns, and modules. Performance Ratios were calculated using the ported functions from pvplr-python and compared against Rdtools YoY values. Due to the complicated nature of degradation, a new metric has been proposed to quantify the performance loss of a system. The cumulative production loss, is the total amount of energy lost due to the degrading performance of the system. Cumulative production loss alleviates the problems with fitting linear functions to non-linear degradation. Cumulative Production loss was shown to better estimate the total lost revenue for non-linear degradation patterns. $XbX + UTC$ was found to most accurately predict the total lost revenue in simulated systems.

Kumar, Suraj↗

Final LDRD report : development of sample preparation methods for ChIPMA-based imaging mass spectrometry of tissue samples.

The objective of this short-term LDRD project was to acquire the tools needed to use our chemical imaging precision mass analyzer (ChIPMA) instrument to analyze tissue samples. This effort was an outgrowth of discussions with oncologists on the need to find the cellular origin of signals in mass spectra of serum samples, which provide biomarkers for ovarian cancer. The ultimate goal would be to collect chemical images of biopsy samples allowing the chemical images of diseased and nondiseased sections of a sample to be compared. The equipment needed to prepare tissue samples have been acquired and built. This equipment includes an cyro-ultramicrotome for preparing thin sections of samples and a coating unit. The coating unit uses an electrospray system to deposit small droplets of a UV-photo absorbing compound on the surface of the tissue samples. Both units are operational. The tissue sample must be coated with the organic compound to enable matrix assisted laser desorption/ionization (MALDI) and matrix enhanced secondary ion mass spectrometry (ME-SIMS) measurements with the ChIPMA instrument Initial plans to test the sample preparation using human tissue samples required development of administrative procedures beyond the scope of this LDRD. Hence, it was decided to make two types of measurements: (1) Testing the spatial resolution of ME-SIMS by preparing a substrate coated with a mixture of an organic matrix and a bio standard and etching a defined pattern in the coating using a liquid metal ion beam, and (2) preparing and imaging C. elegans worms. Difficulties arose in sectioning the C. elegans for analysis and funds and time to overcome these difficulties were not available in this project. The facilities are now available for preparing biological samples for analysis with the ChIPMA instrument. Some further investment of time and resources in sample preparation should make this a useful tool for chemical imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

Siegmund, Oswald↗

Analysis of terrestrial conditions and dynamics

Land spectral reflectance properties for selected locations, including the Goddard Space Flight Center, the Wallops Flight Facility, a MLA test site in Cambridge, Maryland, and an acid test site in Burlington, Vermont, were measured. Methods to simulate the bidirectional reflectance properties of vegetated landscapes and a data base for spatial resolution were developed. North American vegetation patterns observed with the Advanced Very High Resolution Radiometer were assessed. Data and methods needed to model large-scale vegetation activity with remotely sensed observations and climate data were compiled.

Goward, S. N.↗

X-ray Polarimetry with a Micro-Pattern Gas Detector

Topics covered include: Science drivers for X-ray polarimetry; Previous X-ray polarimetry designs; The photoelectric effect and imaging tracks; Micro-pattern gas polarimeter design concept. Further work includes: Verify results against simulator; Optimize pressure and characterize different gases for a given energy band; Optimize voltages for resolution and sensitivity; Test meshes with 80 micron pitch; Characterize ASIC operation; and Quantify quantum efficiency for optimum polarization sensitivity.

Hill, Joe↗

Graph-learning approach to combine multiresolution seismic velocity models

SUMMARY The resolution of velocity models obtained by tomography varies due to multiple factors and variables, such as the inversion approach, ray coverage, data quality, etc. Combining velocity models with different resolutions can enable more accurate ground motion simulations. Toward this goal, we present a novel methodology to fuse multiresolution seismic velocity maps with probabilistic graphical models (PGMs). The PGMs provide segmentation results, corresponding to various velocity intervals, in seismic velocity models with different resolutions. Further, by considering physical information (such as ray path density), we introduce physics-informed probabilistic graphical models (PIPGMs). These models provide data-driven relations between subdomains with low (LR) and high (HR) resolutions. Transferring (segmented) distribution information from the HR regions enhances the details in the LR regions by solving a maximum likelihood problem with prior knowledge from HR models. When updating areas bordering HR and LR regions, a patch-scanning policy is adopted to consider local patterns and avoid sharp boundaries. To evaluate the efficacy of the proposed PGM fusion method, we tested the fusion approach on both a synthetic checkerboard model and a fault zone structure imaged from the 2019 Ridgecrest, CA, earthquake sequence. The Ridgecrest fault zone image consists of a shallow (top 1 km) high-resolution shear-wave velocity model obtained from ambient noise tomography, which is embedded into the coarser Statewide California Earthquake Center Community Velocity Model version S4.26-M01. The model efficacy is underscored by the deviation between observed and calculated traveltimes along the boundaries between HR and LR regions, 38 per cent less than obtained by conventional Gaussian interpolation. The proposed PGM fusion method can merge any gridded multiresolution velocity model, a valuable tool for computational seismology and ground motion estimation.

Geochemistry & Geophysics↗

Compact high-resolution differential interference contrast soft x-ray microscopy

We demonstrate high-resolution x-ray differential interference contrast (DIC) in a compact soft x-ray microscope. Phase contrast imaging is enabled by the use of a diffractive optical element objective which is matched to the coherence conditions in the microscope setup. The performance of the diffractive optical element objective is evaluated in comparison with a normal zone plate by imaging of a nickel siemens star pattern and linear grating test objects. Images obtained with the DIC optic exhibit typical DIC enhancement in addition to the normal absorption contrast. Contrast transfer functions based on modulation measurements in the obtained images show that the DIC optic gives a significant increase in contrast without reducing the spatial resolution. The phase contrast operation mode now available for our compact soft x-ray microscope will be a useful tool for future studies of samples with low absorption contrast.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle Mass Flow Control for High-Temperature Concentrating Solar Receivers

This report summarizes the results of a two-year project funded by the U.S. Department of Energy's Solar Energy Technologies Office (SuNLaMP 1506) to evaluate the performance of high-temperature (>700 °C) particle receivers for concentrating solar power (see Appendix A for project information). In the first year, novel particle release patterns were designed and tested to increase the effective solar absorptance of the particle curtain. Modeling results showed that increasing the magnitude and frequency of different wave-like patterns increased the effective absorptance and thermal efficiency by several percentage points, depending on the mass flow rate. Tests showed that triangular-wave, square-wave, and parallel-curtain particle release patterns could be implemented and maintained at flow rates of ~10 kg/s/m. The second year of the project focused on the development and testing of particle mass-flow control and measurement methods. An automated slide gate controlled by the outlet temperature of the particles was designed and tested. Testing demonstrated that the resolution accuracy of the slide-gate positioning was less than ~1 mm, and the speed of the slide gate enabled rapid adjustments to accommodate changes in the irradiance to maintain a desired outlet temperature range. Different in-situ particle mass-flow measurement techniques were investigated, and two were tested. The in-situ microwave sensor was found to be unreliable and sensitive to variations in particle flow patterns. However, the in-situ weigh hopper using load cells was found to provide reliable and repeatable measurements of real-time in-situ particle mass flow. On-sun tests were performed to determine the thermal efficiency of the receiver as a function of mass flow rate, particle temperature, and irradiance. Models of the tests were also developed and compared to the tests.

14 SOLAR ENERGY↗

Phase-Contrast MRI and CFD Modeling of Apparent 3He Gas Flow in Rat Pulmonary Airways

Phase-contrast (PC) magnetic resonance imaging (MRI) with hyperpolarized 3He is potentially useful for developing and testing patient-specific models of pulmonary airflow. One challenge, however, is that PC-MRI provides apparent values of local 3He velocity that not only depend on actual airflow but also on gas diffusion. This not only blurs laminar flow patterns in narrow airways but also introduces anomalous airflow structure that reflects gas-wall interactions. Here, both effects are predicted in a live rat using computational fluid dynamics (CFD), and for the first time, simulated patterns of apparent 3He gas velocity are compared with in-vivo PC-MRI. Results show (1) that correlations (R2) between measured and simulated airflow patterns increase from 0.23 to 0.79 simply by accounting for apparent 3He transport, and that (2) remaining differences are mainly due to uncertain airway segmentation and partial volume effects stemming from relatively coarse MRI resolution. Higher-fidelity testing of pulmonary airflow predictions should therefore be possible with future imaging improvements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Development and Application of a Method to Quantify the Quality of Cryoprotectant Conditions Using Standard Area Detector X-Ray Images

An X-ray based method for determining cryoprotectant concentrations necessary to protect solutions from crystalline ice formation was developed. X-ray images from a CCD area detector were integrated as powder patterns and quantified by determining the standard deviation of the slope of the normalized intensity curve in the resolution range where ice rings are known to occur. The method was tested determining the concentrations of glycerol, PEG400, ethylene glycol and 1,2-propanediol necessary to form an amorphous glass at 1OOK with each of the 98 crystallization solutions of Crystal Screens I and II (Hampton Research, Laguna Hills, California, USA). For conditions that required glycerol concentrations of 35% or above cryoprotectant conditions using 2,3-butanediol were determined. The method proved to be remarkably accurate. The results build on the work of [Garman and Mitchell] and extend the number, of suitable starting conditions to alternative cryoprotectants. In particular, 1,2-propanediol has emerged as a particularly good additive for glass formation upon flash cooling.

McFerrin, Michael↗

A simulation study exploring the effects of sensor spatial resolution on estimates of cloud cover from satellites.

Investigation of the effects of sensor spatial resolution on estimating the amount of clouds covering the earth by simulating various cloud distributions and sizes, and measuring the known cloud amount with resolution of different sizes using a cloud-no cloud threshold technique often applied in automatic data processing. Cloud amount statistics have been tabulated for a three-orders-of-magnitude range in the ratio (R) of areal cloud size to areal resolution size for seven cloud amounts between 6 and 90%. Three different cloud patterns were used. These were 1) a regularly spaced pattern of homogeneous dots arranged in rows and columns (to simulate cloud streets), 2) a randomly spaced pattern of the same dots (to simulate randomly oriented cumulus clouds), and 3) a heterogeneous cloud size distribution irregularly spaced (to simulate a view of different cloud types and sizes). Two cloud amount estimation techniques were tested. Cloud amounts of 100% (method 1) and 50% (method 2) were assigned to partially filled resolution elements. Using criteria applicable to some studies carried out in the past, it is shown that cloud amount estimations can be in error by as much as 86 and 38%, respectively, for the two methods. Nomograms have been developed which subtantially improve the estimate of the true cloud cover for R less than 100, provided that R can be determined.

Shenk, W. E.↗

1D Atmosphere Models from Inversion of Fe i 630 nm Observations with an Application to Solar Irradiance Studies

Present-day semi-empirical models of solar irradiance (SI) variations reconstruct SI changes measured on timescales greater than a day by using spectra computed in one dimensional atmosphere models (1D models), which are representative of various solar surface features. Various recent studies have pointed out, however, that the spectra synthesized in 1D models do not reflect the radiative emission of the inhomogenous atmosphere revealed by high-resolution solar observations. We aimed to derive observation-based atmospheres from such observations and test their accuracy for SI estimates. We analyzed spectropolarimetric data of the Fe i 630 nm line pair in photospheric regions that are representative of the granular quiet-Sun pattern (QS) and of small- and large-scale magnetic features, both bright and dark with respect to the QS. The data were taken on 2011 August 6, with the CRisp Imaging Spectropolarimeter at the Swedish Solar Telescope, under excellent seeing conditions. We derived atmosphere models of the observed regions from data inversion with the SIR code. We studied the sensitivity of results to spatial resolution and temporal evolution, and discuss the obtained atmospheres with respect to several 1D models. The atmospheres derived from our study agree well with most of the 1D models we compare our results with, both qualitatively and quantitatively (within 10%), except for pore regions. Spectral synthesis computations of the atmosphere obtained from the QS observations return an SI between 400 and 2400 nm that agrees, on average, within 2.2% with standard reference measurements, and within −0.14% with the SI computed on the QS atmosphere employed by the most advanced semi-empirical model of SI variations.

79 ASTRONOMY AND ASTROPHYSICS↗