Search NASA⌕ Search

SEARCH · Search NASA

Results for “safety critical software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

87 records · Page 5

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and validation testing and tools: comparison between MCNP code versions and nuclear data libraries [Slides]

This presentation discusses the primary goal of software testing which is to test the code for correctness. It also discusses the results for individual suites and the role of validation and verification also referred to in the presentation as V&V. In summation, the V&V framework enables easy comparison between calculations performed with different code versions and/or nuclear data libraries. This entire framework will be distributed with the upcoming MCNP6.3 release. V&V test suites shown and several that were not (Criticality, LAQGSM, Lockwood) will be distributed in the new framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation-Based Recovery Action Analysis Using the EMRALD Dynamic Risk Assessment Tool

A recovery action is defined as the action that prevents deviant conditions from producing unwanted effects. It generally indicates a kind of countermeasure performed in response to a failure of human action. The recovery actions especially play an important role in complex systems like nuclear power plants (NPPs), which consist of highly sophisticated controllers to ensure that desired performance and safety must be achieved and maintained. This is because a combination of human error and its recovery failure may be able to cause a catastrophic effect on a system. Analyzing recovery actions has been a critical part of HRA, which is a technique to evaluate human errors and provide human error probabilities (HEPs) for application in probabilistic safety assessment (PSA). If recovery actions are not adequately analyzed and applied to PSA models, the PSA results may be under-estimated or be not able to reasonably account for the failure of human actions in the context of PSA. For this reason, some regulatory documents such as ASME/ANS RA-Sb-2013 by the American Society for Mechanical Engineers and the American Nuclear Society and NUREG-1792 by U.S. Nuclear Regulatory Commission have emphasized the importance of recovery analysis within the HRA. A couple of existing HRA methods, such as the Technique for Human Error-Rate Prediction (THERP), the Cause-Based Decision Tree (CBDT), and the Korean Standard HRA (K-HRA), have respectively suggested their own approaches to the HRA recovery analysis. However, there are a couple of limitations to treating recovery actions using only the current HRA methods available. The biggest limitation is that the existing recovery analysis does not explicitly consider a variety of recovery action types and recovery sequences as they occur in actual NPPs. To handle the limitations of existing recovery analysis, this study proposes a simulation-based recovery analysis method using the Event Modeling Risk Assessment Using Linked Diagram (EMRALD) software. The EMRALD software is a dynamic simulation tool for PSA. It supports realistic and dynamic modeling of human actions as they would be performed at NPPs. It is also favorable to simultaneously model the specific moment at which an action is performed, the time it takes to perform the action, and the failure probability of that action. In this paper, a detailed methodology for modeling recovery actions in the simulation platform is proposed with a couple of examples. Then, outputs from the simulation are discussed as reviewing if this novel approach can complement the challenges of existing recovery analyses.

99 GENERAL AND MISCELLANEOUS↗

A Comparison of RESRAD and GoldSim Models for Assessing Radiological Dose for a RCRA Landfill - 20418

US Ecology Idaho (USEI) operates a Resource Conservation and Recovery Act (RCRA) Subtitle C, Hazardous Waste Treatment, Storage, and Disposal (TSD) Facility on a 640-acre property in Owyhee County, Idaho. USEI accepts a wide variety of RCRA-exempt low activity radioactive wastes, including naturally occurring radioactive material (NORM) and technologically enhanced NORM (TENORM) (USEI 2009). The performance of the landfill with regard to radiological operating permit requirements was previously assessed using a model constructed with the residual radioactivity (RESRAD) computer program, developed by Argonne National Laboratory for the U.S. Department of Energy (DOE). RESRAD supports the evaluation of several environmental transport pathways related to a radionuclide-contaminated soil source term, but it was not conceived as a model for the evaluation of landfill radiological performance. A more comprehensive and realistic model is desired in order to better support submissions to both the State of Idaho's Department of Environmental Quality as well as the U.S. Nuclear Regulatory Commission. A Performance Assessment (PA) computer model was developed using GoldSim software for the USEI RCRA Subtitle C landfill. The RESRAD computer model was specifically developed for calculating soil cleanup criteria and radiological dose and cancer risk from residual radioactive material in soil. To evaluate site-specific conditions, users may select from among a number of available environmental transport and exposure pathways and modify 'default' parameter values. In GoldSim, a user must construct the model 'from scratch.' However, this modeling is facilitated by a number of specialized elements available in GoldSim to support a radiological mass transport model. These include elements for defining radiological decay and ingrowth, container failure and radiological release, advective and diffusive transport, and other processes. Advantages afforded by the use of RESRAD for modeling radiological dose for a RCRA Subtitle C landfill include ease of use and reasonable flexibility in specifying site-specific conditions. GoldSim allows for considerably more flexibility and site-specificity than RESRAD, including evaluation of potentially relevant environmental transport processes not supported in RESRAD. The probabilistic modeling capabilities of GoldSim also far exceed those of RESRAD. The pros and cons of RESRAD and GoldSim for this modeling problem are explored with a focus on identifying approaches and critical factors in identifying the appropriate platform. The capabilities of RESRAD and GoldSim for mathematically modeling the disposal system will be contrasted and compared. For example, the existing RESRAD radiological safety assessment evaluated potentially complete exposure pathways related to infiltration to groundwater and upwards diffusion of radon. Additional transport pathways identified in the USEI Idaho facility Conceptual Site Model include deposition of radon decay products in cover material, root uptake of radionuclides in disposed wastes by native plants, and mixing of cover material by burrowing animals. Results of the two models and how the different transport and dose pathways affect results will be discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Simulation and Computing: ASC FY24 Implementation Plan

The DOE National Nuclear Security Administration (NNSA) Stockpile Stewardship Program (SSP) is an integrated technical program for maintaining the safety, security, and reliability of the U.S. nuclear stockpile. The SSP incorporates nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. The suite of data analyzed comes from activities including previous nuclear tests, stockpile surveillance, experimental research, and development and engineering programs. This integrated national program requires the continued use of experimental facilities and the computational capabilities to support the SSP missions. These component parts, in addition to an appropriately scaled production capability, enable NNSA to support stockpile requirements. The ultimate goal of the SSP, and thus of the Advanced Simulation and Computing (ASC) program, is to ensure that the U.S. maintains a safe, secure, and effective strategic deterrent. The ASC program is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment and certification process, study advanced nuclear weapons design and manufacturing processes, analyze accident scenarios and weapons aging, and provide the tools to enable stockpile Life Extension Programs (LEPs) and the resolution of Significant Finding Investigations (SFIs). This work requires a balance of resources, including technical staff, hardware, simulation software, and computer science solutions. The ASC program focuses on increasing the predictive capabilities in a three-dimensional (3D) simulation environment while maintaining support to the SSP. The Program continues to improve its unique tools for understanding and solving progressively more difficult stockpile problems (sufficient resolution, dimensionality, and scientific details), and quantifying critical margins and uncertainties. Resolving each issue requires increasingly difficult analyses because the aging process has progressively moved the stockpile further from the original test base. While the focus remains on the U.S. nuclear weapons program, where possible, the Program also enables the use of high-performance computing (HPC) and simulation tools to address broader national security needs, such as foreign nuclear weapon assessments and nuclear counterterrorism. The 2022 Nuclear Posture Review (NPR) calls for NNSA to “deliver a modern, adaptive nuclear security enterprise based on an integrated strategy for risk management, production-based resilience, science and technology innovation, and workforce initiatives.” Furthermore, “NNSA will establish a Science and Technology Innovation Initiative to accelerate the integration of science and technology (S&T) throughout its activities.” Executing this strategy necessitates the continued emphasis on developing and sustaining high-quality scientific and engineering staff, as well as supporting computational and experimental capabilities. These components constitute the foundation of the nuclear weapons program. The continued success of the SSP and LEPs is predicated upon the ability to credibly certify the stockpile, without a return to underground nuclear tests (UGTs). Shortly after the nuclear test moratorium entered into force in 1992, the Accelerated Strategic Computing Initiative (ASCI) was established to provide an extensive simulation capability to underpin stockpile certification. While computing and simulation have always been essential to the success of the nuclear weapons program, the program goal of ASCI was to execute NNSA’s vision of using these tools in support of the stockpile stewardship mission. The ASCI program was essential to the successful demonstration of the SSP, providing critical nuclear weapons simulation and modeling capabilities. ASCI officially evolved into the ASC program in fiscal year (FY) 2005, but the mission remains essentially the same: provide the simulation and computational capabilities that underpin the ability to maintain a safe, secure, effective nuclear weapon stockpile, without returning to underground nuclear testing. The capabilities that the ASC program provides at the national laboratories play a vital role in the nuclear security enterprise and are necessary for fulfilling the stockpile stewardship and life extension requirements outlined for NNSA. The Program develops modern simulation tools that provide insights into stockpile aging issues, provide the computational and simulation tools that enable designers and analysts to certify the current stockpile and life-extended nuclear weapons, and inform the decision-making process when any modifications in nuclear warheads or the associated manufacturing processes are deemed necessary. Furthermore, ASC is enhancing the predictive simulation capabilities that are essential to evaluate weapons effects, design experiments, and ensure test readiness. The ASC program continues to improve its unique tools to solve stockpile problems— with a focus on sufficient resolution, dimensionality, and scientific detail—to enable Quantification of Margins and Uncertainties (QMU) and to resolve the increasingly difficult analyses needed for stockpile stewardship. The needs of the Stockpile Management and Production Modernization programs (formerly Directed Stockpile Work) also drive the requirements for simulation and computational resources. These requirements include planned LEPs, stockpile support activities, and mitigation efforts against the potential for technical surprise. All of the weapons within the current stockpile are in some stage of the life extension process. The simulation and computational capabilities are crucial for successful execution of these life extensions and for ensuring NNSA can certify these life-extended weapons without conducting a UGT.

97 MATHEMATICS AND COMPUTING↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

Probabilistic Multi-Hazard Performance Assessment of Concrete Structures in Nuclear Installations

Concrete structures in nuclear installations are subject to time-dependent degradation mechanisms that can deteriorate their physical and mechanical properties, potentially exacerbating the risk of structural failure under external forces such as a seismic event. Previous research has extensively investigated the seismic response of nuclear concrete structures and the associated risk, as well as their effect on structural components safety margins. However, substantial work is still necessary to incorporate concrete aging effects into such evaluations. In fact, most models in the literature assume pristine concrete conditions and do not account for the impact of aging on the structural components’ fragility curves. This work identifies relevant time-dependent degradation mechanisms and provides simplified models to predict the the evolution of key material properties based on data from the literature. Namely, this work focuses on the aging effects of corrosion, alkali–silica reaction (ASR), and irradiation on reinforced concrete within US Department of Energy (DOE) nuclear facilities and nuclear power plants (NPP) structures. Furthermore, degradation models based on literature data are presented that define the relationship between probabilistic material properties and the concrete’s age. In this work, sampled material properties served as input for a simplified finite element model (FEM) of a critical nuclear structural system, with the output of the FEM being the seismic response for a given ground motion. The results of the FEM were then used within a probabilistic performance assessment with a statistically significant number of samples. The research presented herein addresses the detrimental effects of hazards caused by natural phenomena on deteriorated concrete elements of nuclear installations. This work directly benefits the safety analysis performed on US DOE/ National Nuclear Security Administration (NNSA) nuclear facilities located in areas prone to seismic activity. The results presented herein could aid in the improvement of DOE-STD-1020, the DOE Standard that addresses seismic risk analysis and capacity evaluation in DOE facilities. DOE-STD-1020 refers to the requirements in American Society of Civil Engineers (ASCE) 4-98, now superseded by ASCE 4-16, that shall be met in performing dynamic response analyses and generating in-structure response spectra, provided that such requirements are consistent with the requirements of ASCE/Structural Engineering Institute (SEI) 43-05. Moreover, the results presented herein could also aid in the updating of section C3.1.1. of ASCE 4-16 to account for the effects of aging on the stiffness of reinforced elements and American Concrete Institute (ACI) 349.3R-18, “Report on Evaluation and Repair of Existing Nuclear Safety-Related Concrete Structures.” Ultimately, this work can assist the risk assessment of potential lifetime extension of the existing US commercial nuclear fleet (light water reactors) and the safety analysis of the emerging advanced nuclear reactors. The proposed proof-of-concept methodology employs open-source DOE computational tools and is transferable to commercial software commonly used by engineering firms.

42 ENGINEERING↗

Workshop on Improving Holdup Monitoring in the US

The characterization and quantification of nuclear deposits, or residual nuclear material retained in process equipment, generally referred to as holdup, continues to challenge nuclear processing facilities in DOE program areas such as nuclear criticality safety, material control and accountability, environmental management. The efficiency and effectiveness of nuclear operations in these facilities depends heavily on the results from nondestructive techniques designed to measure nuclear materials in situ. The traditional methods used to measure holdup were established more than 30 years ago and assume unrealistic conditions for most measurement cases. These blind, in situ measurements present unique challenges due to the following attributes: unique, non-ideal geometries; unknown deposit thicknesses; lack of representative calibration standards; large number of holdup deposit locations; and poor accessibility for many measurement locations. These difficulties and the poor assumptions made to handle them have resulted in measurement uncertainties that are often too large for many programs to effectively utilize. In an effort to address and identify solutions to the current holdup challenges facing the US nuclear industry, Oak Ridge National Laboratory hosted the Technical Workshop on Improving Holdup Monitoring in the US. The two-day workshop held August 21–22, 2019, was attended by 35 holdup measurement practitioners, program managers, stakeholders from US Department of Energy sites, the Nuclear Regulatory Commission, and representatives from commercial industry. The primary objectives were to identify critical elements of a successful and defensible holdup measurement program; identify technical challenges, needs, and potential improvements associated with measurement of holdup; and share best practices and lessons learned from recent accumulation events. Fourteen presentations were delivered on holdup topics including necessary elements for effective program management, measurement needs, emerging technologies and other measurement solutions, and lessons learned from recent events. These presentations highlighted best practices related to accumulation monitoring, considerations and proactive steps to facilitate holdup in new facility designs, imaging solutions to improve holdup assumptions, and new software developed in support of holdup measurements. Breakout sessions were also employed to determine additional needs and identify potential solutions to common holdup challenges. The primary discussions focused on causes and prevention of material accumulations, needs for uranium and plutonium measurements, and reduction of measurement uncertainty, all of which were explicitly identified as critical needs during the 2018 Workshop on Technical and Programmatic Needs for a Sustainable NDA Program for the US DOE.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Local Power Impact Experiment Design for a New Fuel Type for use in the Advanced Test Reactor

The Advanced Test Reactor (ATR), and complimentary zero-power ATR Critical (ATRC) reactor, located at Idaho National Labs (INL), are undergoing conversion from Highly Enriched Uranium (HEU) to Low Enriched Uranium (LEU). Both have a variety of testing locations that can receive large variations in flux due to its unique serpentine design, consisting of five lobes (see Figure 1). Initial criticality and power distribution throughout the core are controlled by core-external outer shim control cylinders (OSCCs). Distinct test loops allow for testing at specific temperatures, pressures, and irradiation conditions. The ATR is one of the key nuclear engineering research and testing facilities within the DOE National Laboratory Complex, and the ATRC supports its operation [1]. Currently, the Office of Material Management and Minimization (M3) within the National Nuclear Security Administration of the DOE is working to convert the remaining research reactors, including the ATR, from 93% HEU fuel to 19.75% LEU fuel (LEU) to support non-proliferation [2]. Extensive materials testing at INL and internationally has demonstrated that a high-density uranium molybdenum (U 10Mo) alloy can meet the performance requirements of the remaining high powered research reactors. However, there are many technical challenges to address before the conversion to LEU can be successful, including the accurate characterization of the reactor core physics with LEU fuel. Reactor physics safety evaluations currently use Monte Carlo for the 21st Century (MC21), a continuous-energy Monte Carlo radiation transport code [3]. Existing MC21 models of the ATR and ATRC cores have a validation basis for use in neutronics analyses with HEU fuel. The models are used to support safety analyses that include comparisons to the safety requirements for the reactors. However, the use of the LOWE element in the ATR and ATRC is not currently covered by the current model validation basis. To deploy the new fuel type, extensive computational reactor physics support is necessary to support the use of LOWE in the ATR and ATRC. Therefore, LOWE requires a rigorous validation basis, aligned with that of HEU fuel, that takes advantage of the existing software tools and processes currently used for the ATR and ATRC. The experiment to validate of the MC21 models for determining power, the Power Impact Validation Experiment, will consist of two flux runs in the ATRC, one with fully HEU loading and one with a single LOWE element. Both flux runs will be instrumented with 20 sets of azimuthal fission wires and 3 sets of axial fission wires, as shown in Figure 4. Standard flux run methodology will be used [4]. Power Impact Validation Experiment data will be compared against MC21 calculated data, both for absolute fission rate accuracy and to determine the relative change in fission rates between the two runs. The results of the Power Impact Validation Experiment and subsequent evaluations will provide the validation basis for MC21 for use with LOWE elements. Key features of the Power Impact Validation Experiment include: (1) Two flux runs to allow for LOWE perturbed measurements to be compared to already validated measurements taken from a full core of HEU fuel, (2) Optimization of instrumentation to balance analytical needs with practical considerations (e.g., limited time window to count beta particles from fission products), and (3) Standard ATRC core loading, including both driver positions and flux traps, to minimize cost while remaining representative of typical ATR core loading.

42 ENGINEERING↗

Summary of Technical Peer Review on the Risk Assessment Framework proposed in Report INL/RPT-22-68656 for Digital Instrumentation and Control Systems

This report summarizes the peer review activities initiated by Idaho National Laboratory (INL) during fiscal year (FY) 2023 for the evaluation and improvement of the methodology developed under the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) risk assessment project. In FY 2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a technical basis to support effective and secure DI&C technologies for digital upgrades/designs. A framework was proposed for this strategy, which aims to (1) provide a best-estimate, risk-informed capability to quantitatively and accurately estimate the risk impact of plant modernization, considering the introduction of high safety-significant safety-related (HSSSR) DI&C systems, (2) support and supplement existing risk-informed DI&C design guides by providing quantitative risk information and evidence, (3) offer a capability of design architecture evaluation of various DI&C systems, (4) assure the long-term safety and reliability of HSSSR DI&C systems, and (5) reduce uncertainty in costs and support integration of DI&C systems in the plant. The R&D efforts of this project from FY 2019 through FY 2022 were focused on methodology improvement and demonstration of the proposed framework for the risk assessment and design optimization of safety-critical DI&C systems. Collaborations with the nuclear industry have been initiated to support the reliability and risk assessment of their DI&C systems by using the proposed framework. In FY 2023, the framework has reached to a point for a technical peer review and obtain stakeholder feedback. This peer review activity includes coordination of the reviews performed by a group of industry stakeholders, documentation of the peer review suggestions, providing resolutions and responses to the peer review comments. The objective of this technical peer review is to obtain representative feedback on the proposed framework to improve the technical qualities of its methodology and readiness for deployment to the industry. Feedback may identify potential areas for improvement and further development. The Subject Matter experts were invited to review the latest project report documenting the methodology developed in the project and provide evaluations of the technical qualities of the proposed framework and relevant methods. The reviewed project report is “An Integrated Framework for Risk Assessment of High Safety-significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants: Methodology and Demonstration” INL/RPT-22-68656 (short as “INL/RPT-22-68656” in this report). This peer review report documents the technical questions provided for technical peer review and introduces the technical peer reviewers from the stakeholders including nuclear utilities, regulators, and universities. Comments from technical peer reviewers and the resolutions and responses to these comments are outlined. Insights and lessons learned from the technical peer review are summarized in conclusions and future work. The primary audience of this report are DI&C designers, engineers, and probabilistic risk assessment (PRA) practitioners. This includes stakeholders, such as the nuclear utilities and regulators who consider the deployment and upgrade of DI&C systems, DI&C software developers and reviewers, and cybersecurity specialists.

99 GENERAL AND MISCELLANEOUS↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

The MCNP ® 6 code: A decade of progress

After several years of effort involved in merging the Los Alamos National Laboratory MCNP5 and MCNPX codes, in 2013 the first production release of version 6 of the Monte Carlo N-Particle ® , or MCNP ® , code MCNP6.1 was distributed publicly. Since then, three significant releases have been issued: MCNP6.1.1beta in 2014, MCNP6.2 in 2018, and MCNP6.3 in 2023. While each release always contains new features, code enhancements, and bug fixes, each version has had a different primary focus, ranging from improved calculational efficiency to new powerful utilities and tools, to software modernization of the code base. With all that has been learned over the first decade of the MCNP6 code, continuous progress is being made toward a modernized, general-purpose Monte Carlo radiation transport code that remains a trusted resource for the global community of practitioners. This paper describes these first 10+ years of the MCNP6 code and its continually improving data libraries, and gives some insight into how the next decade is expected to unfold.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modernization efforts for the R -Matrix code SAMMY [Abstract]

The R-Matrix code SAMMY is a widely used nuclear data evaluation code focused on the resolved range, which includes corrections for experimental effects. The code is still mostly written in Fortran 77, and uses a memory management system suitable for the time of its initial writing (1984). A modernization effort is under way to bring the code in-line with modern software development practices. A continuous-integration testing framework was added, automating the large existing set of test cases. It is run on every commit. The memory management was updated to current standard practices suitable for modern software analysis tools. The code can be obtained from https://code.ornl.gov/RNSD/SAMMY. The resonance parameters and covariance information are now stored in C++ objects shared by SAMMY and AMPX, the processing code that generates nuclear data libraries for SCALE. This allows for easier maintenance and access to the resonance parameters inside and outside of SAMMY. This feature is already used by accessing and changing parameters in memory in the Bayesian Monte Carlo Evaluation Framework for Cross Sections Nuclear Data and Integral Benchmark Experiments project, Further plans include the switch to the ENDF reading and writing routines in AMPX, as these routines are more robust, easier to maintain, and support more features. Of note here is support for the new GNDS format. Previously it wasn’t easy to share the full covariance matrix for evaluations containing more than one isotope due to limitations on the ENDF format; this is now supported in GNDS. The data are currently available in a binary SAMMY format and can be exported to GNDS to make them more widely available and sharable. The next step will be to use the same resonance processing code at 0K in AMPX and SAMMY as one of the available Reich-Moore R-Matrix formalism. The first step toward this goal is to isolate the reconstruction into a module that takes resonance parameters as its input and does not depend on SAMMY global parameters. This goal has been achieved and it should now be possible to more easily change the resonance formalism and add enhancements as the Phenomenological R-Matrix parameterization of direct, doorway, and compound nuclear reactions discussed elsewhere on this conference. This concerted modernization and enhancement effort provides multiple advantages to the nuclear data community. It will allow parameter optimization using enhanced formalisms, including experimental effects, that better match complex experimental data. Then those evaluated parameters can immediately be passed off to AMPX to be reconstructed with the exact same cross section model and be put into a data library for subsequent testing using SCALE and the Valid Benchmark suite or other suitable benchmark suites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗