Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An Exact and Near-Exact Distribution Approach to the Behrens–Fisher Problem

The Behrens–Fisher problem occurs when testing the equality of means of two normal distributions without the assumption that the two variances are equal. This paper presents approaches based on the exact and near-exact distributions for the test statistic of the Behrens–Fisher problem, depending on different combinations of even or odd sample sizes. We present the exact distribution when both sample sizes are odd and the near-exact distribution when one or both sample sizes are even. The near-exact distributions are based on a finite mixture of generalized integer gamma (GIG) distributions, used as an approximation to the exact distribution, which consists of an infinite series. The proposed tests, based on the exact and the near-exact distributions, are compared with Welch’s t-test through Monte Carlo simulations, in particular for small and unbalanced sample sizes. The results show that the proposed approaches are competent solutions to the Behrens–Fisher problem, exhibiting precise sizes and better powers than Welch’s approach for those cases. Numerical studies show that the Welch’s t-test tends to be a bit more conservative than the test statistics based on the exact or near-exact distribution, in particular when sample sizes are small and unbalanced, situations in which the proposed exact or near-exact distributions obtain higher powers than Welch’s t-test.

Hong, Serim↗

Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

Juarez, Alfredo↗

Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

Juarez, Alfredo↗

High resolution coherent diffractive imaging with a table-top extreme ultraviolet source

We demonstrate a resolution of 45 nm with a sample size down to 3 μm × 3 μm is achieved in a short exposure time of 2 s, from the diffraction pattern generated by a table-top high harmonic source at around 30 nm. By using a narrow-bandwidth focusing mirror, the diffraction pattern's quality is improved and the required exposure time is significantly reduced. In order to obtain a high quality of the reconstructed image, the ratio of the beam size to the sample size and the curvature of the focused beam need to be considered in the reconstruction process. This new experimental scheme is very promising for imaging sub-10 nm scale objects with a table-top source based on a small inexpensive femtosecond laser system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Estimating optimal sampling unit sizes for satellite surveys

This paper reports on an approach for minimizing data loads associated with satellite-acquired data, while improving the efficiency of global crop area estimates using remotely sensed, satellite-based data. Results of a sampling unit size investigation are given that include closed-form models for both nonsampling and sampling error variances. These models provide estimates of the sampling unit sizes that effect minimal costs. Earlier findings from foundational sampling unit size studies conducted by Mahalanobis, Jessen, Cochran, and others are utilized in modeling the sampling error variance as a function of sampling unit size. A conservative nonsampling error variance model is proposed that is realistic in the remote sensing environment where one is faced with numerous unknown nonsampling errors. This approach permits the sampling unit size selection in the global crop inventorying environment to be put on a more quantitative basis while conservatively guarding against expected component error variances.

Hallum, C. R.↗

Data for "Quantifying the Propagation of Parametric Uncertainty on Flux Balance Analysis"

In the repository are example scripts that perform uncertainty injection and propagation to flux balance analysis with outputs for a small sample size (for demonstration purpose only). For proper analysis, user should download the scripts and run for a large sample size (e.g., 10,000 samples). If you use the scripts, please cite the following Metabolic Engineering article: “Quantifying the propagation of parametric uncertainty on flux balance analysis” (https://doi.org/10.1016/j.ymben.2021.10.012) There are two subdirectories: /uncFBA/uncBiom: injection of normally distributed noise to biomass precursor coeffcients and ATP maintenance (growth-associated ATP maintenance (GAM) and non-growth associated ATP maintenance (NGAM)) /uncFBA/uncRHS: departure from steady-state by adding noise drawn from normal distribution to the RHS terms of mass balance constraints

Metabolomics↗

Sampling system for wheat (Triticum aestivum L) area estimation using digital LANDSAT MSS data and aerial photographs

A procedure to estimate wheat (Triticum aestivum L) area using sampling technique based on aerial photographs and digital LANDSAT MSS data is developed. Aerial photographs covering 720 square km are visually analyzed. To estimate wheat area, a regression approach is applied using different sample sizes and various sampling units. As the size of sampling unit decreased, the percentage of sampled area required to obtain similar estimation performance also decreased. The lowest percentage of the area sampled for wheat estimation with relatively high precision and accuracy through regression estimation is 13.90% using 10 square km as the sampling unit. Wheat area estimation using only aerial photographs is less precise and accurate than those obtained by regression estimation.

Parada, N. D. J.↗

Laboratory and Airborne BRDF Analysis of Vegetation Leaves and Soil Samples

Laboratory-based Bidirectional Reflectance Distribution Function (BRDF) analysis of vegetation leaves, soil, and leaf litter samples is presented. The leaf litter and soil samples, numbered 1 and 2, were obtained from a site located in the savanna biome of South Africa (Skukuza: 25.0degS, 31.5degE). A third soil sample, number 3, was obtained from Etosha Pan, Namibia (19.20degS, 15.93degE, alt. 1100 m). In addition, BRDF of local fresh and dry leaves from tulip tree (Liriodendron tulipifera) and acacia tree (Acacia greggii) were studied. It is shown how the BRDF depends on the incident and scatter angles, sample size (i.e. crushed versus whole leaf,) soil samples fraction size, sample status (i.e. fresh versus dry leaves), vegetation species (poplar versus acacia), and vegetation s biochemical composition. As a demonstration of the application of the results of this study, airborne BRDF measurements acquired with NASA's Cloud Absorption Radiometer (CAR) over the same general site where the soil and leaf litter samples were obtained are compared to the laboratory results. Good agreement between laboratory and airborne measured BRDF is reported.

Georgiev, Georgi T.↗

A Bayesian Approach for Quantifying Data Scarcity when Modeling Human Behavior via Inverse Reinforcement Learning

Computational models that formalize complex human behaviors enable study and understanding of such behaviors. However, collecting behavior data required to estimate the parameters of such models is often tedious and resource intensive. Thus, estimating dataset size as part of data collection planning (also known as Sample Size Determination) is important to reduce the time and effort of behavior data collection while maintaining an accurate estimate of model parameters. In this paper, we present a sample size determination method based on Uncertainty Quantification (UQ) for a specific Inverse Reinforcement Learning (IRL) model of human behavior, in two cases: 1) pre-hoc experiment design—conducted in the planning stage before any data is collected, to guide the estimation of how many samples to collect; and 2) post-hoc dataset analysis—performed after data is collected, to decide if the existing dataset has sufficient samples and whether more data is needed. Here, we validate our approach in experiments with a realistic model of behaviors of people with Multiple Sclerosis (MS) and illustrate how to pick a reasonable sample size target. Our work enables model designers to perform a deeper, principled investigation of effects of dataset size on IRL.

97 MATHEMATICS AND COMPUTING↗

Optimized Electromagnetic Fields Levitate Bulk Metallic Materials

The bulk metallic electromagnetic levitation technique has a promising application prospect in condensed physics and materials science. In order to resolve the problem of weak levitation force and the small size of samples, an optimized solution based on finite element analysis (FEA) is developed to seek the best electromagnetic field distribution in the levitation zone. The influence of material properties on the distribution of magnetic flux density, surface pressure, and the Lorentz force were studied by the FEA method with various sample sizes of titanium and copper balls. The levitation capability of cylindrical coil system which consists of a single-layer coil with an inner diameter of 30 mm and the levitated object with a diameter of 20 mm was analyzed. To keep a balance between the turn number and increment efficiency of force, the best number of 7 turns is confirmed. Then, two types of optimized coils were predicted by numerical simulations, and the levitation force is improved drastically. The double-layer coil displays an outstanding levitation capability owing to the strong electromagnetic field generated by multilayer turns. In addition, 5 to 50 g aluminum, titanium, copper, and nickel are levitated by the above three kinds of coils and the levitation capacities are validated from the recorded data of the minimum operating current that can levitate the samples. The experimental results show good agreements with the simulation results, and the minimum current for optimized coils is reduced efficiently.

36 MATERIALS SCIENCE↗

Sampling Density in Regional Exploration and Environmental Geochemical Studies: A Review

A variety of factors contribute to the proper and efficient evaluation of geochemical programs including sampling medium, sample size and sample fraction, sampling density, digestion procedure, and analytical techniques. Among the aforementioned factors, sampling density is of great importance, affecting project ability to detect anomalous sites, which are either economically viable or environmentally hazardous. It is quite critical to have a sufficient number of samples to delineate geochemical anomalies or baselines and to reveal the relative variations in elemental concentrations in a study area. The resolution of the subsequent maps obtained by sampling greatly depends on sampling density. While a large number of samples may generate redundant data, a small number of samples smooth out the patterns and may completely miss anomalies. This review provides a platform for applied geochemists who desire to design a sampling scheme for a regional geochemical program and do not have the financial resources to perform an orientation survey, which will give them the necessary information for designing, according to project objectives, a cost-effective regional geochemical survey for their study area. It is advisable to integrate during the desktop study all available information, such as geological, structural, geophysical, remote sensing data and topographical data by using different data fusion algorithms to arrive at a sampling density fit-for-purpose of the target area. This in turn facilitates an effective spatial positioning of sample locations. Quantitative analyses of the efficiency of different sampling densities for delineating geochemical patterns have not been well documented, warranting more attention and research.

58 GEOSCIENCES↗

Explicit physics-informed neural networks for nonlinear closure: The case of transport in tissues

In upscaling methods, closures for nonlinear problems present a well-known challenge. While a number of theoretical methods have been proposed for handling such closures, nonlinearities still remain a significant obstacle for many problems. In this work, we use a combination of formal upscaling and data-driven machine learning for explicitly closing a nonlinear transport and reaction process in multiscale tissues. The classical effectiveness factor model is used to formulate the macroscale reaction kinetics. We train a multilayer perceptron network using training data generated by direct numerical simulations over microscale examples. Once trained, the network is used in an algorithm for numerically solving the upscaled (coarse-grained) differential equation describing mass transport and reaction in two example tissues. The network is described as being explicit in the sense that the network is trained using macroscale concentrations and gradients of concentration as components of the feature space rather than incorporating them as part of a constraint in the optimization process. Network training and solutions to the macroscale transport equations were computed for two different tissues. The two tissue types (brain and liver) exhibit markedly different geometrical complexity and spatial scale (cell size and sample size). The upscaled solutions for the average concentration are compared with numerical solutions derived from the microscale concentration fields by a posteriori averaging. There are three outcomes of this work of particular note. 1) Our overall approach results in an upscaled nonlinear PDE. The PDE is closed using a neural network, and our approach results in the definition of the classical effectiveness factor for effecting closure. 2) We identify particular source terms for the closure problem that are important for representing the structure of the closure. These source terms involve macroscale concentrations and their gradients. We adopt these source terms to use as explicit features in the learning algorithm. We find the trained networks that include the macroscale source terms generate models that are able to predict the correction factor with increased fidelity over those that do not. 3) We find that the trained network exhibits good generalizability, and it is able to predict the effectiveness factor with high fidelity for realistically-structured tissues despite the significantly different scale and geometrical complexity of the two example tissue types. This latter result emphasizes our purposeful connection between conventional averaging methods with the use of machine learning for closure; this contrasts with some machine learning methods for upscaling where the exact form of the macroscale equation remains unknown.

97 MATHEMATICS AND COMPUTING↗

Creating Accurate Methane Emission Inventories through Data-Driven Airborne Survey Strategies: Methods and Results from the Haynesville, Anadarko, and Permian Basins

Significantly reducing methane emissions from the oil and gas sector can decrease the rate of climate change over the next two decades, buying critical time for a global energy transition. However, emissions inventories that can be used by oil and gas operators and environmental regulators to identify optimal methane emission mitigation strategies are either based on conservative emission factor methods, or are inconsistent between studies due to differences in sampling strategies or survey technologies. We developed a new approach for methane emissions survey design that yields representative basinwide methane emissions inventories by surveying a subset of total assets in a given oil and gas basin. We identify several sampling and analysis principles, including large sample sizes, balanced sampling across oil and gas production, careful survey area definition, and a unified protocol for analysis, to be vital to producing an unbiased estimate of basin-scale emissions that can be reconciled with future studies. We further present results from deploying this strategy in two oil and gas producing regions in the United States: the Haynesville Basin in Texas and Louisiana, and the Woodford Shale in the Anadarko Basin in Oklahoma. Aerial surveys were performed in 2023 using the Insight M LeakSurveyor™ technology. Preliminary results from methane emissions detected by Insight M indicate that aerially detected emissions above roughly 30 kg(CH4)/hr by themselves contribute a fractional loss rate of 1.13% of gross gas production across oil and gas operations in the Haynesville Basin, with aerially detected emissions equivalent to 2.67% of gross gas production in the Woodford Shale. We supplement these aerial estimates with modeled emissions that are below the LeakSurveyor’s survey sensitivity using a recently published inventory-based model of methane emissions, which we update for our survey areas. We then combine our aerial detections with modeled emissions to yield methane emission distributions and inventories that incorporate the full range of potential methane emissions from the smallest to the largest. These results can be used to identify the most effective methane mitigation strategies for our study areas, and can be reconciled with future methane emissions surveys that use different technologies.

Sherwin, Evan (ORCID:0000000321804297)↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

Carbon isotopic analysis of atmospheric methane by isotope-ratio-monitoring gas chromatography-mass spectrometry

Less than 15 min are required for the determination of delta C(sub PDB)-13 with a precision of 0.2 ppt(1 sigma, single measurement) in 5-mL samples of air containing CH4 at natural levels (1.7 ppm). An analytical system including a sample-introduction unit incorporating a preparative gas chromatograph (GC) column for separation of CH4 from N2, O2, and Ar is described. The 15-min procedure includes time for operation of that system, high-resolution chromatographic separation of the CH4, on-line combustion and purification of the products, and isotopic calibration. Analyses of standards demonstrate that systematic errors are absent and that there is no dependence of observed values of delta on sample size. For samples containing 100 ppm or more CH4, preconcentration is not required and the analysis time is less than 5 min. The system utilizes a commercially available, high-sensitivity isotope-ratio mass spectrometer. For optimal conditions of smaple handling and combustion, performance of the system is within a factor of 2 of the shot-noise limit. The potential exists therefore for analysis of samples as small as 15 pmol CH4 with a standard deviation of less than 1 ppt.

Merritt, Dawn A.↗

Thermal conductivity of graphene mediated by strain and size

Based on first-principles calculations and full iterative solution of the linearized Boltzmann–Peierls transport equation for phonons, we systematically investigate effects of strain, size and temperature on the thermal conductivity k of suspended graphene. The calculated size-dependent and temperature-dependent k for finite samples agree well with experimental data. The results show that, contrast to the convergent room-temperature k = 5450 W/m-K of unstrained graphene at a sample size ~8 cm, k of strained graphene diverges with increasing the sample size even at high temperature. Out-of-plane acoustic phonons are responsible for the significant size effect in unstrained and strained graphene due to their ultralong mean free path and acoustic phonons with wavelength smaller than 10 nm contribute 80% to the intrinsic room temperature k of unstrained graphene. Tensile strain hardens the flexural modes and increases their lifetimes, causing interesting dependence of k on sample size and strain due to the competition between boundary scattering and intrinsic phonon–phonon scattering. k of graphene can be tuned within a large range by strain for the size larger than 500 μm. These findings shed light on the nature of thermal transport in two-dimensional materials and may guide predicting and engineering k of graphene by varying strain and size.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Monte Carlo investigation of experimental data requirements for fitting polynomial functions

This report examines the extent to which sample size affects the accuracy of a low order polynomial approximation of an experimentally observed quantity and establishes a trend toward improvement in the accuracy of the approximation as a function of sample size. The task is made possible through a simulated analysis carried out by the Monte Carlo method, in which data are generated by using several transcendental or algebraic functions as models. Contaminated data of varying amounts are fitted to linear quadratic or cubic polynomials, and the behavior of the mean-squared error of the residual variance is determined as a function of sample size. Results indicate that the effect of the size of the sample is significant only for relatively small sample sizes and diminishes drastically for moderate and large amounts of experimental data.

Canavos, G. C.↗