Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Examination of core samples from the Mount Elbert Gas Hydrate Stratigraphic Test Well, Alaska North Slope: Effects of retrieval and preservation

Collecting and preserving undamaged core samples containing gas hydrates from depth is difficult because of the pressure and temperature changes encountered upon retrieval. Hydrate-bearing core samples were collected at the BPXA-DOE-USGS Mount Elbert Gas Hydrate Stratigraphic Test Well in February 2007. Coring was performed while using a custom oil-based drilling mud, and the cores were retrieved by a wireline. The samples were characterized and subsampled at the surface under ambient winter arctic conditions. Samples thought to be hydrate bearing were preserved either by immersion in liquid nitrogen (LN), or by storage under methane pressure at ambient arctic conditions, and later depressurized and immersed in LN. Eleven core samples from hydrate-bearing zones were scanned using x-ray computed tomography to examine core structure and homogeneity. Features observed include radial fractures, spalling-type fractures, and reduced density near the periphery. These features were induced during sample collection, handling, and preservation. Isotopic analysis of the methane from hydrate in an initially LN-preserved core and a pressure-preserved core indicate that secondary hydrate formation occurred throughout the pressurized core, whereas none occurred in the LN-preserved core, however no hydrate was found near the periphery of the LN-preserved core. To replicate some aspects of the preservation methods, natural and laboratory-made saturated porous media samples were frozen in a variety of ways, with radial fractures observed in some LN-frozen sands, and needle-like ice crystals forming in slowly frozen clay-rich sediments. Suggestions for hydrate-bearing core preservation are presented.

54 ENVIRONMENTAL SCIENCES↗

Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards

The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system must also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.

sample conditioning↗

The Impact of ENSO and NAO Initial Conditions and Anomalies on the Modeled Response to Pinatubo-Sized Volcanic Forcing

Strong, strato-volcanic eruptions are a substantial, intermittent source of natural climate variability. Initial atmospheric and oceanic conditions, such as El Niño Southern Oscillation (ENSO) and the North Atlantic Oscillation (NAO), also naturally impact climate on interannual timescales. We examine how initial conditions of ENSO and NAO contribute to the evolution of climate in the period following a Pinatubo-type eruption using a large (81-member) ensemble of model simulations in GISS model E2.1-G. Simulations are initialized from sampled conditions of ENSO and NAO using the protocol of the coordinated CMIP6 Volcanic Model Intercomparison Project (VolMIP) – where aerosols are forced with respect to time, latitude, and height. We analyze paired anomalous variations (perturbed – control) to understand changes in global and regional climate responses under positive, negative, and neutral ENSO and NAO conditions. In particular, we find that for paired anomalies there is a high probability of strong (∼1.5 °C) warming of northern Eurasia surface air temperature in the first winter after the volcanic eruption for negative NAO ensembles coincident with decreased lower stratospheric temperature at the poles, decreased geopotential height, and strengthening of the stratospheric polar vortex. Climate anomalies (relative to average conditions across the control period), however, show no mean warming and suggest that the strength of this response is impacted by conditions present in the selected period of the control run. Again using paired anomalies, we also observe that under both +ENSO and −ENSO ensembles sea surface temperature decreases in the first post-eruptive boreal winter coinciding with surface cooling from volcanic aerosols. Neutral ENSO ensembles, on the other hand, show variability in their response with no clear trend in post-eruptive warming or cooling. In general, paired anomalies from unperturbed simulations give insight into the evolution of the climate response to volcanic forcing; however, when compared with anomalies from climatological conditions, it is clear that paired anomalies are significantly affected by sampled initial conditions occurring at the time of the volcanic eruption.

volcanic eruptions↗

Novel Applications of the Multi-Beam SEM [Abstract Only]

The Zeiss Multi-Beam Scanning Electron Microscope (MultiSEM) was used to image a wide array samples using non-standard operating conditions. The ability of this new, high-throughput imaging technique to produce high-quality images was assessed during this one year LDRD. In addition to exploring new imaging conditions, sample preparation techniques, coupled with theoretical simulations, were explored to optimize the MultiSEM images. To obtain details about the devices imaged, as well as the experimental details, please refer to the classified report from the project manager, Bradley Gabel, or the Cyber IA lead, Justin Ford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aircraft studies of size-dependent aerosol sampling through inlets

Representative measurement of aerosol from aircraft-aspirated systems requires special efforts in order to maintain near isokinetic sampling conditions, estimate aerosol losses in the sample system, and obtain a measurement of sufficient duration to be statistically significant for all sizes of interest. This last point is especially critical for aircraft measurements which typically require fast response times while sampling in clean remote regions. This paper presents size-resolved tests, intercomparisons, and analysis of aerosol inlet performance as determined by a custom laser optical particle counter. Measurements discussed here took place during the Global Backscatter Experiment (1988-1989) and the Central Pacific Atmospheric Chemistry Experiment (1988). System configurations are discussed including (1) nozzle design and performance, (2) system transmission efficiency, (3) nonadiabatic effects in the sample line and its effect on the sample-line relative humidity, and (4) the use and calibration of a virtual impactor.

Porter, J. N.↗

Final Status Report Confirming Completion of Mechanical Testing of HFIR Irradiated Nanocomposite Materials

This report provides a final status report on the in-cell mechanical testing of High Flux Isotope Reactor (HFIR)-irradiated nanodispersion-strengthened materials at the Irradiated Materials Examination and Testing (IMET) facility. All tension tests were performed at room temperature with a nominal strain rate of 0.018 mm/mm/min using shoulder-loading grip sets by following the standard testing procedure in ASTM E8/E8M. Round 1 (unirradiated) and round 2 (0.7 dpa) testing was completed in FY 2021. This report confirms completion of round 3 (1.4 dpa) and round 4 (2.1 dpa) tensile testing in FY 2022 with examples of test data collected on select sample conditions. Additionally, the report includes IDs of samples selected for shipment to Idaho National Laboratory (INL) for additional characterization.

36 MATERIALS SCIENCE↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Research on free and impinging jets for the development of STOL aircraft

The effect of the exit plane conditions on the initial region of an axisymmetric jet was systematically investigated. An essentially top-hat mean velocity profile and a homogeneous turbulence structure were maintained at the exit plane for eight distinct scale and intensity conditions. Mass and momentum flux values are independent of the exit turbulence structure for the range investigated; however, a significant (approximately 25%) increase in the latter implies a pronounced static pressure decrement inside the jet. Details of the velocity profile and turbulence structure are influenced by the exit plane conditions. The three radial-axial components of the Reynolds stress tensor have been conditionally sampled and are analyzed to show the initial condition effects.

Foss, J. F.↗

Joint Bayesian Component Separation and CMB Power Spectrum Estimation

We describe and implement an exact, flexible, and computationally efficient algorithm for joint component separation and CMB power spectrum estimation, building on a Gibbs sampling framework. Two essential new features are (1) conditional sampling of foreground spectral parameters and (2) joint sampling of all amplitude-type degrees of freedom (e.g., CMB, foreground pixel amplitudes, and global template amplitudes) given spectral parameters. Given a parametric model of the foreground signals, we estimate efficiently and accurately the exact joint foreground- CMB posterior distribution and, therefore, all marginal distributions such as the CMB power spectrum or foreground spectral index posteriors. The main limitation of the current implementation is the requirement of identical beam responses at all frequencies, which restricts the analysis to the lowest resolution of a given experiment. We outline a future generalization to multiresolution observations. To verify the method, we analyze simple models and compare the results to analytical predictions. We then analyze a realistic simulation with properties similar to the 3 yr WMAP data, downgraded to a common resolution of 3 deg FWHM. The results from the actual 3 yr WMAP temperature analysis are presented in a companion Letter.

numerical↗

Development of a two photon/laser induced fluorescence technique for the detection of atmospheric OH radicals

The development of a new mid-IR laser source was the primary goal. Backward propagating stimulated D2 Raman frequency down conversion of a commercially available 1.06 micron Nd:YAG laser was shown to generate an efficient source of 1.56 micron radiation with near diffraction limited beam quality. The efficient generation of a 2.9 micron laser source was also achieved using backward propagating CH4 Raman frequency down conversion of the 1.56 micron pump. Slightly higher efficiencies were obtained for frequency down conversion of the 1.06 micron Nd:YAG using the H2 Raman shift yielding a near diffraction limited source in the 200 mJ range at 1.9 micron. Similar conversion efficiencies are anticipated as a result of extending the wavelength coverage of recently available Ti:sapphire pulse laser to not only cover the 740 to 860 nm fundamental wavelength range but also the .95 to 1.15 and 1.06 to 1.33 micron range using D2 and H2, respectively. The anticipated sensitivity of a TP-LIF OH sensor using this mid-IR source would give signal limited detection of 1.4 x 10(exp 5) OH/cu cm under boundary layer conditions and 5.5 x 10(exp 4) OH/cu cm under free troposphere sampling conditions for a five minute signal integration period. This level of performance coupled with the techniques non-perturbing nature and freedom from both interferences and background would allow reliable tropospheric OH measurement to be obtained under virtually any ambient condition of current interest, including interstitial and sampling.

Bradshaw, John↗

Stochastic nonlinear analysis of unidirectional fiber composites using image-based microstructural uncertainty quantification

Here, we present a data-driven nonlinear uncertainty quantification and propagation framework to study the microstructure-induced stochastic performance of unidirectional (UD) carbon fiber reinforced polymer (CFRP) composites. The proposed approach integrates (1) microscopic image characterization, (2) stochastic microstructure reconstruction, and (3) efficient multiscale finite element simulations enabled by self-consistent clustering (SCA) analysis. To model the complex microstructural variability, the proposed UQ methods take the non-Gaussian uncertainty sources into account through a distribution-free sampling approach leveraging nonparametric and asymptotic statistical tools. A hierarchical conditional sampling strategy enables the simultaneous sampling of multiple sources of uncertainties. Our approach provides insights into the impact of microstructural variabilities, which are shown to have an increasing impact on the nonlinear responses of UD CFRP parts under progressive compression loading and ultimately on the failure rate over time. We discover that before CFRP parts start to fail, a characteristic time period emerges with distinctive uncertainty distributions specific to the microstructure variability and the probability of failure. Identifying the failure time period is crucial to the reliability prediction, which is an essential component of CFRP design.

36 MATERIALS SCIENCE↗

Microbial Diversity in Bushmeat Samples Recovered from the Serengeti Ecosystem in Tanzania

Bushmeat, the meat and organs derived from wildlife species, is a common source of animal protein in the diets of those living in sub-Saharan Africa and is frequently associated with zoonotic spillover of dangerous pathogens. Given the frequent consumption of bushmeat in this region and the lack of knowledge about the microbial communities associated with this meat, the microbiome of 56 fresh and processed bushmeat samples ascertained from three districts in the Western Serengeti ecosystem in Tanzania was characterized using 16S rRNA metagenomic sequencing. Here, the results show that the most abundant phyla present in bushmeat samples include Firmicutes (67.8%), Proteobacteria (18.4%), Cyanobacteria (8.9%), and Bacteroidetes (3.1%). Regardless of wildlife species, sample condition, season, or region, the microbiome is diverse across all samples, with no significant difference in alpha or beta diversity. The findings also suggest the presence of DNA signatures of potentially dangerous zoonotic pathogens, including those from the genus Bacillus, Brucella, Coxiella, and others, in bushmeat. Together, this investigation provides a better understanding of the microbiome associated with this major food source in samples collected from the Western Serengeti in Tanzania and highlights a need for future investigations on the potential health risks associated with the harvesting, trade, and consumption of bushmeat in Sub-Saharan Africa.

59 BASIC BIOLOGICAL SCIENCES↗

Unsteady behavior of a reattaching shear layer

A detailed investigation of the unsteadiness in a reattaching, turbulent shear layer is reported. Laser-Doppler velocimeter measurements were conditionally sampled on the basis of instantaneous flow direction near reattachment. Conditions of abnormally short reattachment and abnormally long reattachment were considered. Ensemble-averaging of measurements made during these conditions was used to obtain mean velocities and Rreynolds stresses. In the mean flow, conditional streamlines show a global change in flow pattern which correlates with wall-flow direction. This motion can loosely be described as a 'flapping' of the shear layer. Tuft probes show that the flow direction reversals occur quite randomly and are shortlived. Streses shown also vary with the change in flow pattern. Yet, the global'flapping' motion does not appear to contribute significantly to the stress in the flow. A second type of unsteady motion was identified. Spectral analysis of both wall static pressure and streamwise velocity shows that most of the energy in the flow resides in frequencies that are significantly lower than that of the turbulence. The dominant frequency is at a Strouhal number equal to 0.2, which is the characteristic frequency of roll-up and pairing of vortical structure seen in free shear layers. It is conjectured that the 'flapping' is a disorder of the roll-up and pairing process occurring in the shear layer.

Driver, D. M.↗

Measuring Electrostatic Discharge

Apparatus measures electrostatic-discharge properties of several materials at once. Allows samples charged either by friction or by exposure to corona. By testing several samples simultaneously, apparatus eliminates errors introduced by variations among test conditions. Samples spaced so they pass at intervals under either of two retractable arms. Samples are 2 inches wide along circular path. Arm tips and voltmeter probe are 6 inches from turntable center. Servocontrolled turntable speed constant within 0.1 percent.

Smith, William C.↗

A Single Compartment Relaxed Eddy Accumulation Method

The relaxed eddy accumulation (REA) method is a widely-known technique that measures turbulent fluxes of scalar quantities. The REA technique has been used to measure turbulent fluxes of various compounds, such as methane, ethene, propene, butene, isoprene, nitrous oxides, ozone, and others. The REA method requires the accumulation of scalar concentrations in two separate compartments that conditionally sample updrafts and downdraft events. It is demonstrated here that the assumptions behind the conventional or two-compartment REA approach allow for one-compartment sampling, therefore called a one compartment or 1-C-REA approach, thereby expanding its operational utility. The one-compartment sampling method is tested across various land cover types and atmospheric stability conditions, and it is found that the one-compartment REA can provide results comparable to those determined from conventional two-compartment REA. This finding enables rapid expansion and practical utility of REA in studies of surface-atmosphere exchanges, interactions, and feedbacks.

Banerjee, T.↗

BeyondPlanck: VII. Bayesian estimation of gain and absolute calibration for cosmic microwave background experiments

We present a Bayesian calibration algorithm for cosmic microwave background (CMB) observations as implemented within the global end-to-end BEYONDPLANCK framework and applied to the Planck Low Frequency Instrument (LFI) data. Following the most recent Planck analysis, we decomposed the full time-dependent gain into a sum of three nearly orthogonal components: one absolute calibration term, common to all detectors, one time-independent term that can vary between detectors, and one time-dependent component that was allowed to vary between one-hour pointing periods. Each term was then sampled conditionally on all other parameters in the global signal model through Gibbs sampling. The absolute calibration is sampled using only the orbital dipole as a reference source, while the two relative gain components were sampled using the full sky signal, including the orbital and Solar CMB dipoles, CMB fluctuations, and foreground contributions. We discuss various aspects of the data that influence gain estimation, including the dipole-polarization quadrupole degeneracy and processing masks. Comparing our solution to previous pipelines, we find good agreement in general, with relative deviations of -0.67% (-0.84%) for 30 GHz, 0.12% (-0.04%) for 44 GHz and -0.03% (-0.64%) for 70 GHz, compared to Planck PR4 and Planck 2018, respectively. We note that the BEYONDPLANCK calibration was performed globally, which results in better inter-frequency consistency than previous estimates. Additionally, WMAP observations were used actively in the BEYONDPLANCK analysis, which both breaks internal degeneracies in the Planck data set and results in an overall better agreement with WMAP. Finally, we used a Wiener filtering approach to smoothing the gain estimates. We show that this method avoids artifacts in the correlated noise maps as a result of oversmoothing the gain solution, which is difficult to avoid with methods like boxcar smoothing, as Wiener filtering by construction maintains a balance between data fidelity and prior knowledge. Although our presentation and algorithm are currently oriented toward LFI processing, the general procedure is fully generalizable to other experiments, as long as the Solar dipole signal is available to be used for calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

On the preparation of as-produced and purified single-walled carbon nanotube samples for standardized X-ray diffraction characterization

The aim of this research was to specify proper sample conditioning for acquiring representative X-ray diffraction (XRD) profiles for single-walled carbon nanotube (SWCNT) samples. In doing so, a specimen preparation method for quantitative XRD characterization of as-produced and purified arc-discharge SWCNT samples has been identified. Series of powder XRD profiles were collected at different temperatures, states, and points of time to establish appropriate conditions for acquiring XRD profiles without inducing much change to the specimen. It was concluded that heating in the 300-450 deg. C range for 20 minutes, preferably vacuum-assisted, and then sealing the sample is an appropriate XRD specimen preparation technique for purified arc-discharge SWCNT samples, while raw samples do not require preconditioning for characterization. - Graphical Abstract: A sample preparation method for XRD characterization of as-produced and purified arc-discharge SWCNT samples is identified. The preparation technique seeks to acquire representative XRD profiles without inducing changes to the samples. Purified samples required 20 minutes of heating at (300-450)deg. C, while raw samples did not require preconditioning for characterization. Highlights: {yields} Purification routines may induce adsorption onto the SWCNT samples. {yields} Heating a SWCNT sample may result in material loss, desorption, and SWCNTs closing. {yields} Raw arc-discharge samples do not require preparation for XRD characterization. {yields} Heating is appropriate specimen preparation for purified and heat-treated samples. {yields} XRD data fitting is required for structural analysis of SWCNT bundles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗