Development of an ultra-fast BaF₂-based detector

BaF₂ is one of the fastest known scintillators, emitting at 220 nm with sub-nanosecond decay constant; Excellent for timing applications. 4.88 g/cm³ → High detection efficiency; At 15 cm thick, nearly 100% efficient for gammas up to 10 MeV. Problem: ~80% of the total light output consists of slower (600 ns decay constant) emission peaked at 310 nm; High count rate → pile up. Goal: develop a BaF₂-based detector that leverages the fast emission component for optimal timing characteristics; Suppression of slow component.

47 OTHER INSTRUMENTATION↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Simulations of the nEDM@SNS light collection system efficiency

Here, a system for collecting the scintillation light produced by the capture of ultra-cold neutrons (UCN) on polarized 3 He is discussed and results from simulations of its performance are presented. This system will be implemented in nEDM@SNS, the experiment searching for the neutron electric dipole moment (nEDM) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Simulation results show that the light collection system detects on average 17 photoelectrons per UCN- 3 He capture event (sufficient to generate a robust signal), reconstructs the event location in the beam direction to approximately 3 cm accuracy, detects capture events with a high and spatially uniform efficiency (0.95 with 1% variation), and rejects greater than 50% of beta decay background events.

47 OTHER INSTRUMENTATION↗

Reflector coatings development (FY2020 End of Year Report)

X-ray detection instrumentation has been developed and manufactured at LANL for various DOE programs. One way to improve light collection efficiency, for a scintillator type detector, is to apply suitable reflectors. The coating capability and fabrication procedure for Al reflective coatings was established in FY19 at MST-7. Al reflective coatings with good stability, good adhesion to LSO, and reflectivity (R) up to 78% were fabricated. Materials with higher diffuse reflectivity (such as Teflon tape R=99%) are desirable. A literature search revealed a number of materials in the form of paint or free standing tape with diffuse R = 98- 99%. However, for the intended application such reflectors have to be applied in the form of a coating with strong adhesion to LSO crystals. The purpose of the FY20 project was to develop thin film coating techniques for PTFE (known as Teflon) reflectors and fabricate reflective coatings on provided LSO crystals.

36 MATERIALS SCIENCE↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Performance of black silicon photodiodes for VUV detection in noble liquids

Black silicon (b-Si) photodiodes are an emerging technology that employs silicon nanostructures to enhance the efficiency of photon detection. Recently, we demonstrated nearly 100% quantum efficiency at <200 nm vacuum ultraviolet (VUV) wavelengths at ambient and in noble liquids, making such devices particularly useful for direct detection of scintillation light in noble liquid detectors. This is important in nuclear science experiments like DarkSide, LUX, XENON, and nEXO, where detection of weak VUV scintillation photons in noble liquids are used to identify rare physics radiation events. Here, we measured the response of b-Si photodiode to the scintillation light generated by alpha particles, all immersed in a LAr and LXe test cell. We established a guideline for future development of b-Si photodetectors with internal gain to reach single-photon sensitivity.

47 OTHER INSTRUMENTATION↗

Polysiloxane Scintillators for Efficient Neutron and Gamma-Ray Pulse Shape Discrimination

Plastic scintillators based on thermoplastics, such as polystyrene and poly(vinyl toluene) (PVT), are capable of neutron and γ radiation detection via pulse shape discrimination (PSD) when overdoped with select fluorescent molecules. This class of plastic scintillator has been extensively studied but is limited to applications suitable for thermoplastics. For applications requiring flexibility, scintillators composed of elastomers, such as polysiloxanes, offer an alternative to PVT scintillators. Polysiloxane scintillators are inherently flexible and have a short processing time on the order of 3 h in air and equivalent or better detection capability at reduced doping concentration (<5 wt %). This work presents polysiloxane-based scintillators, containing only 1–5 wt % of 2,5 diphenyl-oxazole (PPO) or 9,9-dimethyl-2-phenyl-9H-fluorene (PhF) as primary dopants and 9,9-dimethyl-2,7-distyryl-9H-fluorene (SFS) as a wavelength shifter. A 5 wt % PPO polysiloxane sample had improved neutron and gamma ray PSD and comparable light yield than EJ-299-33 tested under the same conditions, i.e., figure of merit (FoM) of 1.33 ± 0.03 at 450 keV ee and light yield of 94% relative to EJ-299-33. The 5 wt % PhF-polysiloxane sample had a higher light yield, 144% of EJ-299-33 but lower FoM under the same conditions (FoM of 1.09 ± 0.03). Furthermore, this work highlights the potential of polysiloxanes as a matrix for PSD capable plastic scintillators.

36 MATERIALS SCIENCE↗

Novel Perovskite Semiconductors for the Detection of Special Nuclear Material

Special nuclear material detection using portable, highly efficient detectors is of paramount importance to national security and environmental monitoring. Current neutron detectors, including gas proportional counters and scintillators, are not suitable for discrete or portable monitoring due to size, weight, and power limitations. For example, 3 He gas proportional detectors have significant drawbacks, including long absorption lengths, high voltage requirements, and dependence on the availability of 3 He. The goal of this project is to synthesize a novel, boron-based perovskite semiconductor crystals to create a more efficient and more portable neutron detector. This innovative material will lead to a significant decrease in power and size requirements with higher operating temperatures than other traditional solid-state detectors. Directly incorporating 10 B eliminates the need for a conversion layer and leads to high neutron absorption coefficients. In this seedling project, we used inverse temperature crystallization with boron precursors to create CH 3 NH 3 PbI 3-x (BF 4 ) x . The crystals were analyzed with X-ray diffraction, but the results were inconclusive. Future work will focus on tailoring the solution growth and selecting appropriate solvents and precursors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of borated scintillator screens for high-resolution neutron imaging

The most commonly used screens for neutron imaging consist of 6 LiF + ZnS. This type of screen yields the highest light output per detected neutron. For high resolution, gadolinium oxysulfide (GOS, Gadox) screens are employed, which have a much higher detection efficiency, but a light output so much lower than LiF + ZnS that measurements are often limited by photon statistics. Historically, screens using boron as a neutron-sensitive material have not been very successful. However, a new preparation method was introduced recently that produces light output higher than Gadox with detection efficiency greater than LiF + ZnS. Measurements of these new borated screens were performed at the NeXT facility at ILL, Grenoble, in comparison to a high resolution Gadox screen.

10B↗

How silicon and boron dopants govern the cryogenic scintillation properties of N -type GaAs

This work is the first report describing how the concentrations of silicon and boron govern the cryogenic scintillation properties of n-type GaAs. It shows that valence band holes are promptly trapped on radiative centers and then combine radiatively with silicon donor band electrons at rates that increase with the density of free carriers. It also presents the range of silicon and boron concentrations needed for efficient light emission under X-ray excitation, which along with its low band gap and apparent absence of afterglow, make scintillating GaAs suitable for the detection of rare, low-energy electronic excitations from interacting dark matter particles. A total of 29 samples from four different suppliers were studied. Luminosities and timing responses were measured for the four principal emission bands centered at 860, 930, 1070, and 1335 nm, and for the total emissions. Excitation pulses of 40 kVp X-rays were provided by a light-excited X-ray tube driven by an ultra-fast laser. Scintillation emissions from 800 to 1350 nm were measured using an InGaAs photomultiplier. Within the concentration ranges of free carriers from 2 x 10 16 /cm 3 to 6 x 10 17 /cm 3 and boron from 1.5 × 10 18 /cm 3 to 6 x 10 18 /cm 3 , nine samples have luminosities > 70 photons/keV and two have luminosities > 110 photons/keV. Other samples in that range have lower luminosities due to higher concentrations of non-radiative centers. The decay times decrease by typically a factor of ten with increasing free carrier concentrations from 10 17 /cm 3 to 2 x 10 18 /cm 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized Photoemission from Organic Molecules in 2D Layered Halide Perovskites

In recent years, hybrid organic−inorganic metal halides have been at the forefront of materials research. Typically, the functional (e.g., optoelectronic) properties of hybrid halides are derived from the inorganic structural part, whereas the organic structural units can add extra advantages in terms of stability, rigidity, and processability. Here, we report the design, synthesis, and characterization of two new hybrid materials in which the outstanding photophysical properties originate from the organic structural part. The new compounds, (C 15 H 16 N) 2 CdCl 4 and ((Br)C 15 H 15 N) 2 CdCl 4 , have 2D layered Ruddlesden−Poppertype perovskite structures. These hybrids are blue-white light emitters just like their corresponding pure organic salts, but with much improved emission efficiencies. Optical spectroscopy and density functional theory (DFT) studies confirm that photoemission comes from the trans-stilbene organic cations. The photoluminescence quantum yield (PLQY) values of these new materials are among the highest known, 50.83% and 26.60% for (C 15 H 16 N) 2 CdCl 4 and ((Br)C 15 H 15 N) 2 CdCl 4 , respectively. This is up to a 5-fold increase as compared to the light emission efficiency of the precursor salt C 15 H 16 NCl (PLQY of 10.33%). Alongside their outstanding optical properties, their environmental and thermal stability allow their consideration for potential practical applications such as radiation detection. This work shows that hybrid metal halides can be compositionally and structurally engineered to have highly efficient photoemission originating from the organic components for fast scintillation applications.

Halogens↗

An Evaluation of a Passively Cooled Cylindrical Spectrometer Array in Lunar Orbit

This thesis will evaluate a passively cooled cylindrical spectrometer array in lunar orbit characterizing the thermal response in order to provide context for decision-making to scientists and engineers. To provide perspective on thermal issues and controls of space science instruments, a background search of historical lunar missions is provided. Next, a trial science mission is designed and analyzed which brings together the elements of the background search, lunar orbit environment and passive cooling. Finally, the trial science mission analysis results are provided along with the conclusions drawn. Scintillators are materials that when struck by particle radiation, absorb the particle energy which is then reemitted as light in or near the visible range. Nuclear astrophysics utilizes scintillating materials for observation of high-energy photons which are generated by sources such as solar flares, supernovae and neutron stars. SPMs are paired with inorganic scintillators to detect the light emitted which is converted into electronic signals. The signals are captured and analyzed in order to map the number and location of the high-energy sources. The SPM is utilized as it has single photon sensitivity, low voltage requirements and a fast response. SPMs are also compact, relatively inexpensive and allow the usage of lower-cost scintillating materials within the spectrometer. These characteristics permit large-area arrays while lowering cost and power requirements. The ability of a spectrometer to record and identify the interaction of high-energy photons for scientific return is not a trivial matter. Background noise is generated when particles that have not originated from the desired distant source impact the spectrometer. Additionally, thermally induced electrical signals are randomly generated within the SPM even in the absence of light which is referred to as dark current. Overcoming these obstacles requires greater light emittance and energy resolution with reduced dark current. Strong scintillation photon emittance ensures that low energy impacts will produce enough visible photons to be detected by the SPM. Higher energy resolution will ensure that single photon impacts can be distinguished from others of similar wavelength and energy; reduced dark current decreases the generation of random signals not associated with a photon impact. Increasing efficiency in each of these properties in a spectrometer comprised of inorganic scintillators and SPMs requires low temperatures. Low temperature maintenance in a lunar environment presents many unique challenges of its own. Even with the accumulated successes of past missions, the lunar environment remains a thermal challenge for engineers. The lunar orbit thermal environment is driven by radiation from three sources, direct solar radiation, reflected solar radiation from the lunar surface (albedo) and lunar radiation (Clawson 2002). Direct solar radiation values are consistent with those seen in Earth orbit (1325 W/m2) (Clawson 2002). The percentage of solar radiation reflected from the moon is consistently very low with the moon's dark regolith covered surface absorbing nearly 90% of the incident light (Clawson 2002). Yet, it is this absorption that gives the lunar orbit environment one of its most difficult thermal attributes as the absorbed solar radiation is released from the lunar surface as infrared radiation (IR). IR is of a wavelength that is readily absorbed by surfaces designed to function as radiation emitters. It is practical to therefore "choose radiator locations and spacecraft attitude to minimize radiator views to the lunar surface, when possible...pointing the radiator towards the sun to some extent, to minimize its view to the lunar surface, is frequently preferable. (Clawson 2002)" Additionally, the amount of direct solar radiation, lunar IR and albedo an orbiting satellite receives varies from one side of the moon to the other as the moon blocks the sun from view. This environment produces large temperature variations in a satellite's instrumentation, control electronics and propulsion systems which must be understood to characterize operating temperature envelopes.

Waggoner, Jason↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Impact of xenon doping in the scintillation light in a large liquid-argon TPC

The use of xenon-doped liquid argon (Xe-doped LAr) is a promising alternative for large-scale liquid argon Time Projection Chambers (LAr-TPC), since it mitigates the light suppression due to impurities and it also improves the photon-detection efficiency and uniformity with the distance. This study analyses the impact of using Xe-doped LAr in ProtoDUNE Dual-Phase, a 750 ton Dual-Phase LAr-TPC placed at CERN. ProtoDUNE Dual-Phase completed a Xe-doping data-taking campaign in summer 2020 by re-filling the detector with 230 tons of Xe-doped LAr contaminated with nitrogen, and performing dedicated nitrogen injections. The effects of the presence of Xe at 5.8 ppm in the scintillation light production and propagation are analysed in this paper, showing an increase of the collected photons, but a suppression of the light signal amplitude. A 60% increase of the light attenuation length is measured. The impact on the scintillation time profile is also studied. A model to fit the time profile is proposed and the time constants of the physics processes are obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

VUV light collection enhancement with metasurface lenses

Vacuum-ultraviolet (VUV) light has applications in many areas of fundamental research and technology, including high-energy physics (HEP) experiments and especially those based on scintillation of noble elements (xenon and argon).There are persistent challenges associated with the detection of the VUV photons in particle detectors, e.g. strong absorption by structural materials and low detection efficiency of the photosensors.Metasurfaces are relatively novel nano-fabricated devices which offer unprecedented control of light with a wide field of view and diffraction-limited focusing.This contribution will present the first linear metasurface lens operating in the VUV spectral range with the measured diffraction efficiencies above 50%.The design and fabrication processes will be described in detail, as well as the characterization measurements, and possible applications in the HEP experiments will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗