Search NASA⌕ Search

SEARCH · Search NASA

Results for “screening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Production and Evaluation of Fluorophore-Doped Polymer Substrates to Screen for Plastic-Degrading Enzymes

Fast and sensitive analytical methods are the key to efficient screening of plastic-degrading enzymes. Here, we present a streamlined and affordable approach to assess the enzymatic deconstruction of insoluble synthetic polymers by blending them with a fluorescent dye, rhodamine 6G, and we evaluate this screening method using poly(ethylene terephthalate) (PET) as a model material. Our results indicate that enzymatic depolymerization of the rhodamine-doped PET can be observed in a high-throughput fashion by following release of the fluorophore. The fluorescence data obtained during the hydrolysis of rhodamine-doped PET by 14 PET hydrolases, produced with a robotic platform, correlated with the quantitative chromatographic analysis of PET degradation products. Remarkably, the use of the rhodamine-loaded PET substrate resulted in negligibly low background signals even when detecting PETase activity in crude cell lysates, suggesting suitability for screening of a wide variety of samples. Encouraged by these results, we next produced a selection of polyethylene- and nylon-based materials loaded with rhodamine 6G. While rapid leaching of fluorophore observed with nylon substrates limits the utility of the method for detecting nylonase activity, the rhodamine-loaded polyethylene showed promising performance in passive diffusion tests, indicating that this latter substrate may be used to screen for polyolefin-degrading enzymes.

09 BIOMASS FUELS↗

Beyond sequence similarity: toward function-based screening of nucleic acid synthesis

Synthetic nucleic acids are a key input to modern biotechnology, yet they represent dual-use materials that require robust screening to mitigate biosecurity risks. The prevailing screening paradigm, which identifies sequences of concern (SoCs) through sequence similarity to controlled pathogens and toxins, may not fully capture risks posed by AI tools that can decouple biomolecular function from reliance on known sequences. Rapidly advancing biodesign capabilities enable the generation of genes and proteins that might evade sequence-based detection. We highlight the critical need for function-based screening approaches that can detect sequences capable of hazardous biological functions, regardless of similarity to known SoCs. We examine the feasibility of function-based screening with an initial focus on proteins, arguing that, while protein sequence space is vast, biologically functional proteins are significantly constrained by biophysical and biochemical requirements that can be learned and modeled. We propose a concrete implementation framework organized along a continuum of complexity, starting with toxins as the most tractable targets before expanding to more complex pathogenic functions. We then discuss open challenges and describe a research and development strategy to address them.

59 BASIC BIOLOGICAL SCIENCES↗

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot↗

Adaptive Data Screening for Multi-Angle Polarimetric Aerosol and Ocean Color Remote Sensing Accelerated by Automatic Differentiation

Remote sensing measurements from multi-angle polarimeters (MAPs) contain rich aerosol microphysical property information, and these sensors have been used to perform retrievals in optically complex atmosphere and ocean systems. Previous studies have concluded that, generally, five moderately separated viewing angles in each spectral band provide sufficient accuracy for aerosol property retrievals, with performance gradually saturating as angles are added above that threshold. The Hyper-Angular Rainbow Polarimeter (HARP) instruments provide high angular sampling with a total of 90-120 unique angles across four bands, a capability developed mainly for liquid cloud retrievals. In practice, not all view angles are optimal for aerosol retrievals due to impacts of clouds, sun glint, and other impediments. The many viewing angles of HARP can provide resilience to these effects, if the impacted views are screened from the dataset, as the remaining views may be sufficient for successful analysis. In this study, we discuss how the number of available viewing angles impacts aerosol and ocean color retrieval uncertainties, as applied to two versions of the HARP instrument. AirHARP is an airborne prototype that was deployed in the ACEPOL field campaign, while HARP2 is an instrument in development for the upcoming NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission. Based on synthetic data, we find that a total of 20-30 angles across all bands (i.e. five to eight viewing angles per band) are sufficient to achieve good retrieval performance. Following from this result, we develop an adaptive multi-angle polarimetric data screening (MAPDS) approach to evaluate data quality by comparing measurements with their best-fitted forward model. The FastMAPOL retrieval algorithm is used to retrieve scene geophysical values, by matching an efficient, deep learning-based, radiative transfer emulator to observations. The data screening method effectively identifies and removes viewing angles affected by thin cirrus clouds and other anomalies, improving retrieval performance. This was tested with AirHARP data, and we found agreement with the High Spectral Resolution Lidar-2 (HSRL-2) aerosol data. The data screening approach can be applied to modern satellite remote sensing missions, such as PACE, where a large amount of multi-angle, hyperspectral, polarimetric measurements will be collected.

multi-angle polarimeter↗

Plasma-Induced Electron Screening at the Bragg Peak

Over 36 years of laboratory astrophysics experiments employing accelerated hydrogen isotope beams have demonstrated the role of electron screened, enhanced nuclear reactions. The astrophysical role of weak and strong electron screening was first discussed by Saltpeter [1] in 1954 and later by Hagino and Balantekin [2] in 2002. Assenbaum, et al. [3], Czerski, et al. [4], and Schenkel, et al., [5] have used accelerated deuteron beams on various metal targets and observed increased fusion rates over the expected Astrophysical, S(E), and Gamow Factors for bare deuteron-deuteron fusion rates. The Pines calculated both electron screened direct and asymptotic enhancement factors, f(E) [6]. Arguably, electron screening makes LENR possible.

plasma↗

Plasma-Induced Electron Screening at the Bragg Peak

Over 36 years of laboratory astrophysics experiments employing accelerated hydrogen isotope beams have demonstrated the role of electron screened, enhanced nuclear reactions. The astrophysical role of weak and strong electron screening was first discussed by Saltpeter in 1954 and later by Hagino and Balantekin in 2002. Assenbaum, et al., Czerski, et al., and Schenkel, et al., have used accelerated deuteron beams on various metal targets and observed increased fusion rates over the expected Astrophysical, S(E), and Gamow Factors for bare deuteron-deuteron fusion rates. The Pines calculated both electron screened direct and asymptotic enhancement factors, f(E). Arguably, electron screening makes LENR possible.

plasma↗

Screening green solvents for multilayer plastic film recycling processes

Multilayer (ML) plastic films are essential packaging materials that help protect products from diverse external factors; however, only 5% of all ML films are recycled in the United States. Solvent-based technologies are a promising alternative for recycling ML films because they enable recovery of constituent polymer resins. For example, the Solvent Targeted Recovery and Precipitation (STRAPTM) process sequentially dissolves and separates polymer components using a series of targeted solvent washes. A crucial design aspect of this process is the impact of selected solvents on human health and on the environment. Here, this work introduces a computational framework that integrates molecular modeling, process modeling, techno-economic analysis (TEA), and life-cycle analysis (LCA) to quickly screen green solvents for solvent-based ML recycling processes. Initial screening for solvents based on selectivity is performed by estimating temperature-dependent solubilities using molecular-scale models. Subsequent screening uses basic estimates of energy use and octanol-water partition coefficients (logP) as key measures of health, safety, and environmental hazards. Detailed process modeling, TEA, and LCA are used on a reduced set of promising solvents identified in early screening steps to more accurately determine how solvent selection and associated operating conditions impact overall economics and environmental impacts. The framework is used for the identification of green solvents (from a database of 1,000 solvents) that separate an industrial ML film composed of polyethylene (PE), ethylene vinyl alcohol (EVOH), and polyethylene terephthalate (PET). Our analysis shows the effectiveness of the framework and reveals fundamental trade-offs between solvent greenness, solubility, and economics. Our work emphasizes the importance of taking a holistic systems view during solvent design and aims to inform the development of new processes for ML film recycling and the identification of new ML films that are easier to recycle.

economics↗

Observation of two cascading screening processes in an iron-based superconductor

Understanding how renormalized quasiparticles emerge in strongly correlated electron materials provides a challenge for both experiment and theory. It has been predicted that distinctive spin and orbital screening mechanisms drive this process in multiorbital materials with strong Coulomb and Hund’s interactions. Here, we provide the experimental evidence of both mechanisms from angle- resolved photoemission spectroscopy on RbFe 2 As 2 . We observe that the emergence of low-energy Fe 3d xy quasiparticles below 90K coincides with spin screening. A second process changes the spectral weight at high energies up to room temperature. Supported by theoretical calculations we attribute it to orbital screening of Fe 3d atomic excitations. These two cascading screening processes drive the temperature evolution from a bad metal to a correlated Fermi liquid.

Condensed-matter physics↗

Low-Cost Screening of Algae for Extreme Tolerance to pH, Temperature, Salinity, and Light

AbstractBioprospecting algae strains with tolerance to extreme conditions such as pH, temperature, salinity, and light is crucial for advancing biotechnology and environmental applications. However, traditional screening methods often involve significant costs and labor, restricting their accessibility and practical use. In this study, we developed and validated low-cost, high-throughput screening techniques, predominantly employing agar plates and liquid culture assays, to effectively differentiate tolerance levels among various algae strains. The methodologies were optimized using the model microalgaChlamydomonas reinhardtiiand its closely related speciesChlamydomonas incertaand the recently discovered extremophilicChlamydomonas pacifica. We systematically evaluated the algae for tolerance to extremes by establishing precise gradients of pH (acidic to alkaline conditions), salinity (0 to 5 M NaCl), temperature (34–42°C), and light intensity (40 to 2977 μE·m⁻²·s⁻¹). Our results demonstrated that these cost-effective, agar plate-based methods effectively distinguished algae strains exhibiting superior tolerance to extreme environmental conditions. These screening techniques not only provided clear differentiation among the closely related strains but also delivered reproducible outcomes suitable for scaling up to larger bioprospecting efforts. Furthermore, the affordability and simplicity of these methods facilitate their implementation in resource-limited laboratories, thereby broadening participation in algae bioprospecting endeavors. This study highlights the potential of low-cost, accessible screening techniques to significantly enhance the discovery and characterization of algal strains with extreme traits. Ultimately, these methods support the development of robust algae-based resources, driving innovation in diverse industrial processes and environmental solutions.Graphical Abstract

Saucedo, Barbara (ORCID:0009000008860839)↗

Develop High-Throughput Workflows for Whole-Genome Sequencing and Insertion Site Screening (CRADA Final Report)

The engineering of microbes for biomanufacturing (e.g. of fuels, chemicals, materials) applications has advanced to a stage where researchers screen genetic libraries with millions of variations each for those with enhanced productivity. This screening, however, can be slow and expensive, as screening individual variants in a high-throughput yet cost-effective manner is challenging. In this project, we aimed to reduce by 3-fold costs associated with the sequencing aspects of the screening process (to determine which genetic variant is responsible for an observed change in productivity), while being able to process over 1,000 samples per batch.

60 APPLIED LIFE SCIENCES↗

Develop High-Throughput Workflows for Whole-Genome Sequencing and Insertion Site Screening

The engineering of microbes for biomanufacturing (e.g. of fuels, chemicals, materials) applications has advanced to a stage where researchers screen genetic libraries with millions of variations each for those with enhanced productivity. This screening, however, can be slow and expensive, as screening individual variants in a high-throughput yet cost-effective manner is challenging. In this project, we aimed to reduce by 3-fold costs associated with the sequencing aspects of the screening process (to determine which genetic variant is responsible for an observed change in productivity), while being able to process over 1,000 samples per batch.

60 APPLIED LIFE SCIENCES↗

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

Normal Impingement of a Circular Liquid Jet onto a Screen in a Weightless Environment

The normal impingement of a circular liquid jet onto a fine-mesh screen in a weightless environment was investigated. Equations were developed to predict the velocity of the emerging jet on the downstream side of the screen as a function of screen and liquid parameters and of the velocity of the impinging jet. Additionally, the stability of the emerging jet was found to be Weber number dependent. In general, excepting at high velocities, the screen behaved much as a baffle, deflecting the major portion of the impinging flow.

Symons, E. P.↗

Radiographic amplifier screens: Fabrication process and characteristics

The fabrication process and transfer characteristics for solid state radiographic image transducers (radiographic amplifier screens) is described. These screens were developed for use in real time nondestructive evaluation procedures that require large format radiographic images with contrast and resolution capabilities unavailable with conventional fluoroscopic screens. This work was directed toward screens usable for inmotion, on-line radiographic inspection by means of closed circuit television.

Szepesi, Z. P.↗

Irradiate-anneal screening of total dose effects in semiconductor devices

Judicious choice of radiation dose and parameter change acceptance criteria, absence of anomalous anneal phenomena, and absence of anomalous reirradiation effects are recognized as essential for a successful irradiation-anneal (IRAN) screening procedure to ensure that no device will fall, upon reirradiation, above parametric limits assigned for the worst case application. Reirradiation and irradiation-anneal behavior of various semiconductor devices are compared and those that do not lend themselves to IRAN screening are singled out. Information needed to judge the suitability of an IRAN type screening program is detailed. Reasons for success of the limited IRAN screening of flight parts for the Mariner Jupiter/Saturn (MJS '77) spacecraft are indicated.

Stanley, A. G.↗

Fabrication and characteristics of experimental radiographic amplifier screens

The fabrication process and transfer characteristics for solid state radiographic image transducers (radiographic amplifier screens) are described. These screens are for use in realtime nondestructive evaluation procedures that require large format radiographic images with contrast and resolution capabilities unavailable with conventional fluoroscopic screens. The screens are suitable for in-motion, on-line radiographic inspection by means of closed circuit television. Experimental effort was made to improve image quality and response to low energy (5 kV and up) X-rays.

Szepesi, Z.↗

Considerations for the installation of honeycomb and screens to reduce wind-tunnel turbulence

Tests were conducted on a half-scale model representing a 0.914-m (3.0-ft) square stream tube of the flow through the fourth corner and settling chamber of the Langley 8-Foot Transonic Pressure Tunnel. The model included the tube cooler 45 degree turning vanes, and the turbulence reduction screens and honeycomb, which were the subject of the tests. Hot-wire measurements of the turbulence reduction for various combinations of screens and honeycomb were made at various duct speeds. Of the four sizes of honeycomb cells tested, none were found to have a superior performance advantage. The effectiveness of screens and honeycomb in reducing turbulence is greatly affected by relatively minor physical damage; therefore, extreme care must be exercised in installing and maintaining honeycomb or screens if the turbulence reduction performance is to be maintained.

Scheiman, J.↗

Flow through very porous screens

Flow through and around screens with small resistance coefficient were analyzed. Both steady and oscillatory flows are considered, however, the case of a screen normal to the flow is treated. At second order in the asymptotic expansion the steady flow normal to the screen is nonuniform along the screen, due to components induced by the wake and by tangential drag. The third order pressure drop is nonuniform and the wake contains distributed vorticity, in addition to the vortex sheet along its boundary. The unsteady drag coefficient is found as a function of frequency.

Durbin, P. A.↗