Search NASA⌕ Search

SEARCH · Search NASA

Results for “secondary control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

Direct Aerobic Generation of a Ferric Hydroperoxo Intermediate Via a Preorganized Secondary Coordination Sphere

Enzymes exert control over the reactivity of metal centers with precise tuning of the secondary coordination sphere of active sites. One particularly elegant illustration of this principle is in the controlled delivery of proton and electron equivalents in order to activate abundant but kinetically inert oxidants such as O 2 for oxidative chemistry. Chemists have drawn inspiration from biology in designing molecular systems where the secondary coordination sphere can shuttle protons or electrons to substrates. However, a biomimetic activation of O 2 requires the transfer of both protons and electrons, and molecular systems where ancillary ligands are designed to provide both of these equivalents are comparatively rare. Here, we report the use of a dihydrazonopyrrole (DHP) ligand complexed to Fe to perform exactly such a biomimetic activation of O 2 . In the presence of O 2 , this complex directly generates a high spin Fe(III)-hydroperoxo intermediate which features a DHP• ligand radical via ligand-based transfer of an H atom. This system displays oxidative reactivity and ultimately releases hydrogen peroxide, providing insight on how secondary coordination sphere interactions influence the evolution of oxidizing intermediates in Fe-mediated aerobic oxidations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An adaptive model-free robotic force control strategy for hydrodynamic real-time hybrid simulation of floating offshore wind turbines

Real-time hybrid simulation (RTHS) - a cyber-physical testing approach - promises to enhance the simulation fidelity of the model-scale experiments used to prototype floating offshore wind turbines (FOWTs). In hydrodynamic RTHS (hydro-RTHS), actuators emulate aerodynamic forces on model-scale FOWT specimens subjected to physical waves in a hydrodynamic laboratory. Robotic arms are promising candidates for actuation in hydro-RTHS due to their compact multi-degree-of-freedom (DOF) capabilities. Unlike classical RTHS for seismic applications, which typically relies on displacement control, hydro-RTHS requires 6-DOF force control on newly designed floating prototypes in a model-scale setting, which presents significant challenges, including modeling uncertainties, directional asymmetry, configuration drift, bandwidth limitations, and time-varying delays. To mitigate these constraints without extensive pre-test calibration, this study proposes an adaptive model-free robotic force control strategy that combines task-space explicit force control with a secondary joint-space pose-keeping task. The Adaptive Feedforward Compensator (AFC) is integrated into the force control loop to compensate for time-varying delay. Experimental testing was conducted using a Franka Emika Panda robotic arm with a 1:50 scale FOWT specimen under operational wind and wave conditions. Results demonstrate stable and consistent 6-DOF force tracking. Effective delay compensation was observed, with low-frequency delay reductions ranging from 71.4% to 91.8% and improvements in low-frequency surge force tracking of 25.0% to 52.1%. This study enhances robotic actuation performance in hydro-RTHS and introduces a force control strategy that supports reliable robotic operation in uncertain floating environments. Future work will explore disturbance-observer mechanisms to further enhance wave rejection capabilities under extreme wind and wave conditions.

17 WIND ENERGY↗

Application of Advanced Metering Infrastructure Data to Advanced Utility System Operations: Cooperative Research and Development, CRADA Number CRD-17-00712 (Final Report)

The primary objective of the proposed project is to evaluate the capabilities of Advanced Metering Infrastructure (AMI) based controls for grid operations. This includes monitoring and control at the secondary transformer level using existing AMI infrastructure. In addition, some of the challenges of using a model-less control will also be identified. The lessons learned will be disseminated to other utilities around the country through peer-reviewed publications with the consent of SDG&E. The scope of the work includes using data from SDG&E's existing AMI infrastructure and working with third party vendors selected by SDG&E. The grid edge monitoring systems and controls provided by the selected vendors will perform grid operations using AMI data. The National Renewable Energy Laboratory (NREL) will perform a software and controller-based evaluation of the grid edge controller, intelligent devices and sensors, at the Energy System Integration Facility (ESIF) laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Canopy responses of Swedish primary and secondary forests to the 2018 drought

Boreal forest ecosystems are predicted to experience more frequent summer droughts due to climate change, posing a threat to future forest health and carbon sequestration. Forestry is a regionally dominant land use where the managed secondary forests are typically even-aged forests with low structural and tree species diversity. It is not well known if managed secondary forests and unmanaged primary forests respond to drought differently in part because the location of primary, unmanaged, forests has remained largely unknown. Here we employed a unique map detailing over 300 primary forests in Sweden. We studied impacts of the 2018 nationwide drought by extracting and analyzing a high-resolution remote sensing vegetation index over the primary forests and over buffer zones around the primary forests representing secondary forests. We controlled for topographical variations linked to soil moisture, which was a strong determinant of drought responses, and analyzed Landsat-derived EVI2 anomalies during the drought year from a multiyear non-drought baseline. We found that primary forests were less affected by the drought compared to secondary forests. Our results indicate that forestry may exacerbate the impact of drought in a future climate with more frequent and extreme hydroclimatic events.

54 ENVIRONMENTAL SCIENCES↗

Using a Grid-Forming Inverter to Stabilize a Low-Inertia Power System - Maui Hawaiian Island

As power systems around the world integrate greater amounts of wind and solar photovoltaic power, periods of very high instantaneous power shares of inverters, the primary interfacing technology for these generation sources, are complicating system stability and control. The contemporary, primary mode of inverter operation, grid-following, which explicitly assumes the presence of a local, stable voltage waveform, yields operational inadequacy at high instantaneous power shares potentially leading to instability due to the low-inertia conditions, as well as the correlated reduced voltage forming capacity on the respective system. Parallel connected grid-forming inverters, which directly regulate the local voltage, are a solution that is expected to bolster system stability and mitigate the shortcomings of the grid-following technology. In this paper, grid-following and two types of grid-forming inverter control, the traditional linear droop and the recently introduced nonlinear exponential droop (Droop-e), are simulated on a low-inertia, H = 0.48s, high inverter-based resource scenario, 97%, with a validated electromagentic transient domain model of the Hawaiian island of Maui power system. The benefit of a single grid-forming device over its grid-following counterpart is significant, both in terms frequency deviation and voltage stability. Further, the superiority of the Droop-e and the associated secondary power sharing control over both grid-following and linear droop grid-forming technologies is displayed, with improved nadir and rate of change of frequency over the linear droop control.

droop control↗

Biogeochemical Controls on the Potential for Long-Term Contaminant Leaching from Soils Developing on Historic Coal Mine Spoil

Coal mine spoil is widespread in US coal mining regions, and the potential long-term leaching of toxic metal(loid)s is a significant and underappreciated issue. This study aimed to determine the flux of contaminants from historic mine coal spoil at a field site located in Appalachian Ohio (USA) and link pore water composition and solid-phase composition to the weathering reaction stages within the soils. The overall mineralogical and microbial community composition indicates that despite very different soil formation pathways, soils developing on historic coal mine spoil and an undisturbed soil are currently dominated by similar mineral weathering reactions. Both soils contained pyrite coated with clays and secondary oxide minerals. However, mine spoil soil contained abundant residual coal, with abundant Fe- and Mn- (oxy)hydroxides. These secondary phases likely control and mitigate trace metal (Cu, Ni, and Zn) transport from the soils. While Mn was highly mobile in Mn-enriched soils, Fe and Al mobility may be more controlled by dissolved organic carbon dynamics than mineral abundance. There is also likely an underappreciated risk of Mn transport from coal mine spoil, and that mine spoil soils could become a major source of metals if local biogeochemical conditions change.

58 GEOSCIENCES↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

Engineering Curcumin Biosynthesis in Poplar Affects Lignification and Biomass Yield

Lignocellulosic biomass is recalcitrant toward deconstruction into simple sugars mainly due to the presence of lignin. By engineering plants to partially replace traditional lignin monomers with alternative ones, lignin degradability and extractability can be enhanced. Previously, the alternative monomer curcumin has been successfully produced and incorporated into lignified cell walls of Arabidopsis by the heterologous expression of DIKETIDE-CoA SYNTHASE (DCS) and CURCUMIN SYNTHASE2 (CURS2). The resulting transgenic plants did not suffer from yield penalties and had an increased saccharification yield after alkaline pretreatment. Here, we translated this strategy into the bio-energy crop poplar. Via the heterologous expression of DCS and CURS2 under the control of the secondary cell wall CELLULOSE SYNTHASE A8-B promoter (ProCesA8-B), curcumin was also produced and incorporated into the lignified cell walls of poplar. ProCesA8-B:DCS_CURS2 transgenic poplars, however, suffered from shoot-tip necrosis and yield penalties. Compared to that of the wild-type (WT), the wood of transgenic poplars had 21% less cellulose, 28% more matrix polysaccharides, 23% more lignin and a significantly altered lignin composition. More specifically, ProCesA8-B:DCS_CURS2 lignin had a reduced syringyl/guaiacyl unit (S/G) ratio, an increased frequency of p-hydroxyphenyl (H) units, a decreased frequency of p-hydroxybenzoates and a higher fraction of phenylcoumaran units. Without, or with alkaline or hot water pretreatment, the saccharification efficiency of the transgenic lines was equal to that of the WT. These differences in (growth) phenotype illustrate that translational research in crops is essential to assess the value of an engineering strategy for applications. Further fine-tuning of this research strategy (e.g., by using more specific promoters or by translating this strategy to other crops such as maize) might lead to transgenic bio-energy crops with cell walls more amenable to deconstruction without settling in yield.

59 BASIC BIOLOGICAL SCIENCES↗

Shape memory polymers

New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

59 BASIC BIOLOGICAL SCIENCES↗

Shape memory polymers

New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.

Wilson, Thomas S.↗

The Response of Summertime Organic Aerosol Composition to Emission Controls in the Northeastern United States

The responses of secondary organic aerosols (SOA) to emission controls remain uncertain due to the limited continuous long‐term measurements. Measurements of detailed carbonaceous aerosol composition in the New York City metropolitan region during the summers of 2001, 2009, 2011, and 2018 provide a look at the changes in summertime SOA over the past two decades when significant pollution reduction and emission controls occurred in the northeastern United States. Here, we show that the averaged nighttime SOA, especially the fresh local SOA, extreme mass concentrations resulted from anthropogenic volatile organic compounds reductions, while there is a little trend for the regional aged SOA. Meanwhile, these fresh SOA extremes occurred most often under conditions of high relative humidity during nighttime. The analysis presented here provides a comprehensive evaluation of the evolution of the increasingly important organic component of the submicron ambient aerosols in this major metropolitan area.

Zhang, Jie↗

SEM petrography of dispersed organic matter in black shales: A review

Organic matter (OM)-hosted pores are important constituents of the pore system of black shales and play a crucial role in determining their methane adsorption capacity and porosity. OM-hosted pores are generally observed and described with scanning electron microscope (SEM) on Ar ion-milled surfaces. However, SEM imaging is not able to reliably distinguish OM types and relate the observed pores to specific macerals. Partly because of this inability to relate organic pores to macerals, the evolution of organic porosity during thermal maturation remains poorly understood. In this paper, we review the petrographic characteristics of dispersed organic matter (DOM) in black shales under the SEM. Organic petrographic classification of DOM developed for reflected-light microscopy is so far the most practical method when describing DOM in black shales under the SEM because this classification has information on the origin of DOM. Therefore, correlative microscopy (combination of reflected-light and electron microscopy) is the most effective method to identify both OM types and OM-hosted pores. This method, however, is not readily available to most researchers. Although identifying OM on the basis of SEM observations is a challenging task, it is achievable provided there is a good understanding of the studied shales, especially their thermal maturity and original OM composition. Therefore, the overall objective of this paper is to review petrographic characteristics of DOM in black shales under the SEM to provide some guidelines for identifying DOM from SEM observations. We also review factors that control the formation and preservation of OM-hosted pores. OM-hosted pores consist of primary and secondary organic pores. Primary organic pores are pores inherited from the biological structure of the original OM. Secondary organic pores develop during hydrocarbon generation and expulsion from oil-prone OM and are hosted by solid bitumen or pyrobitumen. The development of secondary organic pores is controlled by thermal maturity and OM type, and their preservation is subject to thermal maturity, OM content, and mineralogical composition. The presented view of the evolution of micropore and mesopore characteristics of OM with thermal maturity is based on data from the literature. The specific surface area and pore volume of OM in black shales follow a parabolic pattern with increasing thermal maturity (quantified via vitrinite reflectance, R o ). The initial increase reflects development of OM-hosted pores, and the subsequent decrease is due to denser stacking of aromatic units in the macromolecular structure of OM, with maximum values (specific surface area ~ 300 m 2 /g and pore volume ~ 0.3 cm 3 /g) reached at R o values in the 2.5-3.5% range. The contribution of OM-hosted pores to the pore characteristics of black shales depends on OM content, OM type, and thermal maturity.

03 NATURAL GAS↗

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phase Shift Control of a Three-Phase Inverter for Balanced Secondary Currents in Misaligned Three-Phase Inductive Power Transfer Systems

This paper presents a strategy for generating fundamental reference voltage commands for a double-sided LCC tuned three-phase wireless power transfer (WPT) system to achieve balanced output currents when the receiver and transmitter are not perfectly aligned. Formulas for translating the normalized fundamental current commands into phase-shift commands for two of the phase legs in a two-level three-phase inverter are derived. The methodology is validated through circuit simulations performed using coupler models derived from finite-element simulations. Simulation results for a 1.5 k W system design are included, which indicate near perfect correction of imbalance in the secondary currents for a typical misalignment case.

Pries, Jason↗