Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Vibro-Acoustic Modulation Based Damage Identification in a Composite Skin-Stiffener Structure

The vibro-acoustic modulation method is applied to a composite skin-stiffener structure to investigate the possibilities to utilize this method for damage identification in terms of detection, localisation and damage quantification. The research comprises a theoretical part and an experimental part. An impact load is applied to the skin-stiffener structure, resulting in a delamination underneath the stiffener. The structure is interrogated with a low frequency pump excitation and a high frequency carrier excitation. The analysis of the response in a frequency band around the carrier frequency is employed to assess the damage identification capabilities and to gain a better understanding of the modulations occurring and the underlying physical phenomena. Though vibro-acoustic is shown to be a sensitive method for damage identification, the complexity of the damage, combined with a high modal density, complicate the understanding of the relation between the physical phenomena and the modulations occurring. more research is recommended to reveal the physics behind the observations.

Ooijevaar, T. H.↗

Standardization of Spore Inactivation Method for PMA-PhyloChip Analysis

In compliance with the Committee on Space Research (COSPAR) planetary protection policy, National Aeronautics and Space Administration (NASA) monitors the total microbial burden of spacecraft as a means for minimizing the inadvertent transfer of viable contaminant microorganisms to extraterrestrial environments (forward contamination). NASA standard assay-based counts are used both as a proxy for relative surface cleanliness and to estimate overall microbial burden as well as to assess whether forward planetary protection risk criteria are met for a given mission, which vary by the planetary body to be explored and whether or not life detection missions are present. Despite efforts to reduce presence of microorganisms from spacecraft prior to launch, microbes have been isolated from spacecraft and associated surfaces within the extreme conditions of clean room facilities using state of the art molecular technologies. Development of a more sensitive method that will better enumerate all viable microorganisms from spacecraft and associated surfaces could support future life detection missions. Current culture-based (NASA standard spore assay) and nucleic-acid-based polymerase chain reaction (PCR) methods have significant shortcomings in this type of analysis. The overall goal of this project is to evaluate and validate a new molecular method based on the use of a deoxyribonucleic acid (DNA) intercalating agent propidium monoazide (PMA). This is used in combination with DNA microarray (PhyloChip) which has been shown to identify very low levels of organisms on spacecraft associated surfaces. PMA can only penetrate the membrane of dead cells. Once penetrated, it intercalates the DNA and, upon photolysis using visible light it produces stable DNA monoadducts. This allows DNA to be unavailable for further PCR analysis. The specific aim of this study is to standardize the spore inactivation method for PMA-PhyloChip analysis. We have used the bacterial spores Bacillus subtilis 168 (standard laboratory isolate) as a test organism.

spore inactivation↗

Calculation of machine precision second order derivatives using dual-complex numbers

It is well known that both complex and dual numbers can be employed to obtain machine precision first-order derivatives; however, neither, on their own, can compute machine precision 2nd order derivatives. To address this limitation, it is demonstrated in this paper that combined dual-complex numbers can be used to compute machine precision 1st and 2nd order derivatives. The dual-complex approach is simpler than utilizing multicomplex or hyper-dual numbers as existing dual libraries can be used as is or easily augmented to accept complex numbers, and the complexity of developing, integrating, and deploying multicomplex or hyper-dual libraries is avoided. The efficacy of this approach is demonstrated for both univariate and multivariate functions. Finally, source code examples using the Python, Julia, and Mathematica languages are provided as supplemental material.

97 MATHEMATICS AND COMPUTING↗

Symmetrization of Strong Hydrogen Bond under High Pressure in Bihydroxide-Ion-Containing NaCu 2 (SO 4 ) 2 ·H 3 O 2 Revealed by Experimental Charge Density, Single-Crystal Electron Diffraction, and Neutron Diffraction Studies

In minerals and inorganic compounds, strong hydrogen bonding can lead to the formation of complex ionic species such as the H 3 O 2 – bihydroxide anion and Zundel cation H 5 O 2 + . We studied [NaCu 2 (SO 4 ) 2 ·H 3 O 2 ] natrochalcite, which contains bihydroxide anions and undergoes hydrogen bond symmetrization at the lowest pressure reported so far among inorganic compounds. Hydrogen bond symmetrization leads to changes in the bulk modulus, seismic wave velocities, and proton mobility and plays a primary role in high-temperature superconductivity, but its characteristics are not well understood due to a lack of systematic studies and limitations of experimental methods sensitive to this subtle change. In this work, we applied experimental charge density analysis based on in situ single-crystal X-ray diffraction data, along with the single-crystal neutron and electron diffraction experiments, to probe the behavior of hydrogen atoms during the hydrogen bond symmetrization process under high-pressure conditions. On the way to the symmetrical H-bonding, natrochalcite undergoes a series of complex redistributions of electron density, which we trace with multipole refinement and detailed analysis of changes in the Laplacian of electron density values. Additionally, we deconvoluted the equation of state (volume of the unit cell vs pressure relation) into the atomic equation of states describing dependencies of atomic charges or volumes vs pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Editors’ Choice—Rapid Deactivation Convolutes Electrochemical CO 2 Reduction Selectivity Measurements on Gold Rotating Ring Disk Electrodes

Voltammetric measurements of electrochemical CO 2 reduction reaction (CO 2 RR) selectivity on rotating ring disk electrodes (RRDE) are a rapid and sensitive method for quantifying an electrocatalyst’s selectivity, i.e. faradaic efficiency (FE). This method has been applied to polycrystalline Au electrocatalysts where a Au disk electrode catalyzes both the CO 2 RR and hydrogen evolution reaction while the concentric Au ring electrode selectively senses CO by oxidizing CO back to CO 2 . Such measurements enabled fundamental mechanistic studies but suffer from poor inter-laboratory reproducibility. This work identifies causes of variability in RRDE selectivity measurements by comparing protocols with different electrochemical methods, reagent purities, and glassware cleaning procedures. We observed FE CO decrease by 56% during 5 min chronoamperometry measurements, a phenomenon that is not readily apparent in voltammetric scans due to their dynamic nature. Electroplating of electrolyte impurities onto the disk and ring surfaces were identified as a major contributor to Au deactivation. Additionally, the oxygen reduction reaction may lead to higher disk currents in inadequately purged electrolytes, causing an apparent underestimation of FE CO at low overpotentials. Lastly, we propose operational bounds for CO 2 RR selectivity measurements on Au using the RRDE method and provide suggestions on steps for improving the accuracy of this technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated Algorithms for Screening Electronic Parts for Aging using Power Spectra Analysis (PSA) Data

Understanding the age of semiconductor parts being built into devices and systems is of interest for manufacturing quality control. Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining semiconductor parts. This talk will cover the use of multivariate analysis on both PSA data and conventional current-voltage data generated prior to PSA analysis to create algorithms that can be automated to screen semiconductor parts for aging.

Multari, Rosalie A↗

Identification and evaluation of linear damping models in beam vibrations

Sensitive method, identifying effective damping mechanisms, involves comparing experimentally determined ratio of first to second mode magnification factors related to common point on beam. Cluster size has little effect on frequencies of elements, magnification factor decreases with cluster size, and viscous and stress damping are dominant damping mechanisms.

Boers, B. L.↗

The use of the transmission windows of the Fabry-Perot interferometer in the detection of Raman scattered radiation from atmospheric gases.

Demonstration that the use of the Fabry-Perot interferometer as a filter with transmission windows occurring at regular intervals in wave numbers provides a highly sensitive method for detection of atmospheric gases using their rotational Raman spectra excited by a suitable laser. Some of the operating advantages include signal gains of several orders of magnitude, a simple direct interpretation of the results in terms of the density and types of the gaseous constituents, size and weight reductions from conventional apparatus, ease of operation, and relative freedom from interference from other molecules in the scattering volume. This method is compared with the techniques that have been discussed in the literature by other workers in the field.

Smith, W. H.↗

The simultaneous quantitation of ten amino acids in soil extracts by mass fragmentography

A specific and sensitive method for the identification and simultaneous quantitation by mass fragmentography of ten of the amino acids present in soil was developed. The technique uses a computer driven quadrupole mass spectrometer and a commercial preparation of deuterated amino acids is used as internal standards for purposes of quantitation. The results obtained are comparable with those from an amino acid analyzer. In the quadrupole mass spectrometer-computer system up to 25 pre-selected ions may be monitored sequentially. This allows a maximum of 12 different amino acids (one specific ion in each of the undeuterated and deuterated amino acid spectra) to be quantitated. The method is relatively rapid (analysis time of approximately one hour) and is capable of the quantitation of nanogram quantities of amino acids.

Pereira, W. E.↗

Determination of hydrogen in milligram quantities of titanium and its alloys

An accurate, versatile, and sensitive method for the determination of hydrogen in milligram-size titanium samples is presented. It involves extraction of hydrogen at 1070 K while a mercury diffusion pump transfers the evolved gases into the inlet of a mass spectrometer. All the evolved gases may then be positively identified and determined. This method can be readily adapted for use with other metals and for the study of the slow evolution of hydrogen. Reduction of interferences due to the evolution of hydrogen by reactions involving vapors such as those of water, acetone, and vacuum grease is discussed.

Otterson, D. A.↗

Gas-liquid chromatography in lunar organic analysis.

Gas-liquid chromatography (GLC) is a powerful and sensitive method for the separation and detection of organic compounds at nanogram levels. The primary requirement for successful analyses is that the compounds of interest must be volatile under the chromatographic conditions employed. Nonvolatile organic compounds must be converted to volatile derivatives prior to analysis. The derivatives of choice must be both amenable to chromatographic separation and be relatively stable. The condition of volatility necessitates the development of efficient derivatization reactions for important groups of compounds as amino acids, carbohydrates, nucleosides, etc. Trimethylsilylation and trifluoroacetylation represent specific areas of recent prominence. Some relevant practical aspects of GLC are discussed.

Gehrke, C. W.↗

Molecular contamination study by interaction of a molecular beam with a platinum surface

The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.

Nuss, H. E.↗

Technology for return of planetary samples

The problem of returning a Mars sample to Earth was considered. The model ecosystem concept was advanced as the most reliable, sensitive method for assessing the biohazard from the Mars sample before it is permitted on Earth. Two approaches to ecosystem development were studied. In the first approach, the Mars sample would be introduced into the ecosystem and exposed to conditions which are as similar to the Martian environment as the constitutent terrestrial organisms can tolerate. In the second approach, the Mars sample would be tested to determine its effects on important terrestrial cellular functions. In addition, efforts were directed toward establishing design considerations for a Mars Planetary Receiving Laboratory. The problems encountered with the Lunar Receiving Laboratory were evaluated in this context. A questionnaire was developed to obtain information regarding important experiments to be conducted in the Planetary Receiving Laboratory.

Source record↗

Ion chromatographic determination of anions collected on filters at altitudes between 9.6 and 13.7 kilometers

The investigation of atmospheric pollution to determine the anion-containing particulates in the atmosphere at altitudes between 9.6 and 13.7 km is discussed. Air samples collected on cellulose fiber discs impregnated with dibutoxyethylphthalate require very sensitive methods of analysis. It is concluded that ion chromatography is suited for the determination of anions collected on the filters. Methods to control contamination and interfering side reactions are described.

Otterson, D. A.↗

Measurement of flow angle and mass flow rate in an unknown flow field using hot film and hot wire probes

A data reduction technique applicable to constant temperature hot film and hot wire probes is presented which is used to determine flow angle and mass flow rate in an unknown flow field over a wide range of flow conditions at supersonic and hypersonic velocities. The technique virtually eliminates the effect of Reynolds number on a probe's flow angle sensitivity. Methods for extrapolating a limited amount of mass flow rate calibration data to include the range of mass flow rate encountered in an experiment are also given. This technique has been applied to data obtained using a hot film probe during surveys in the leeside flow field of a space shuttle orbiter configuration.

Helms, V. T., III↗

Passive maser development at NRL

The application of passive hydrogen masers to satellites was investigated. The NRL maser is of compact design suitable for the space environment. It is based on a dielectrically loaded sapphire cavity and uses a computer optimized set of four shields. The servo design is a phase sensitive method which directly measures the phase dispersion of the interrogating signal as it passes through the cavity.

White, J. D.↗

Selection of fluorescence lidar operating parameters for SNR maximization

Fluorescence lidar when applicable offers one of the most sensitive methods for measuring the concentration of trace constituents of the atmosphere. In the conduct of a fluorescence lidar experiment, a number of parameters which can be used to optimize the SNR can be controlled. In this paper the optimum division of laser pulses centered on and off the fluorescence excitation wavelength is calculated as a function of the ratio of the fluorescence signal strength to the strength of fluorescence from interfering species. For strong interference signals the time should be divided equally on and off the line. For strong fluorescence signals the time on line is proportional to the square root of the on-line off-line signal ratio. The optimization of the integration time for varying values of signal-to-background and signal-to-interference ratios, atmospheric attenuation, laser energy variations, background measurement time, and on-line off-line time division is also considered.

Heaps, W. S.↗