Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Molecular contamination study by interaction of a molecular beam with a platinum surface

The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.

Nuss, H. E.↗

Technology for return of planetary samples

The problem of returning a Mars sample to Earth was considered. The model ecosystem concept was advanced as the most reliable, sensitive method for assessing the biohazard from the Mars sample before it is permitted on Earth. Two approaches to ecosystem development were studied. In the first approach, the Mars sample would be introduced into the ecosystem and exposed to conditions which are as similar to the Martian environment as the constitutent terrestrial organisms can tolerate. In the second approach, the Mars sample would be tested to determine its effects on important terrestrial cellular functions. In addition, efforts were directed toward establishing design considerations for a Mars Planetary Receiving Laboratory. The problems encountered with the Lunar Receiving Laboratory were evaluated in this context. A questionnaire was developed to obtain information regarding important experiments to be conducted in the Planetary Receiving Laboratory.

Source record↗

Ion chromatographic determination of anions collected on filters at altitudes between 9.6 and 13.7 kilometers

The investigation of atmospheric pollution to determine the anion-containing particulates in the atmosphere at altitudes between 9.6 and 13.7 km is discussed. Air samples collected on cellulose fiber discs impregnated with dibutoxyethylphthalate require very sensitive methods of analysis. It is concluded that ion chromatography is suited for the determination of anions collected on the filters. Methods to control contamination and interfering side reactions are described.

Otterson, D. A.↗

Measurement of flow angle and mass flow rate in an unknown flow field using hot film and hot wire probes

A data reduction technique applicable to constant temperature hot film and hot wire probes is presented which is used to determine flow angle and mass flow rate in an unknown flow field over a wide range of flow conditions at supersonic and hypersonic velocities. The technique virtually eliminates the effect of Reynolds number on a probe's flow angle sensitivity. Methods for extrapolating a limited amount of mass flow rate calibration data to include the range of mass flow rate encountered in an experiment are also given. This technique has been applied to data obtained using a hot film probe during surveys in the leeside flow field of a space shuttle orbiter configuration.

Helms, V. T., III↗

Passive maser development at NRL

The application of passive hydrogen masers to satellites was investigated. The NRL maser is of compact design suitable for the space environment. It is based on a dielectrically loaded sapphire cavity and uses a computer optimized set of four shields. The servo design is a phase sensitive method which directly measures the phase dispersion of the interrogating signal as it passes through the cavity.

White, J. D.↗

Selection of fluorescence lidar operating parameters for SNR maximization

Fluorescence lidar when applicable offers one of the most sensitive methods for measuring the concentration of trace constituents of the atmosphere. In the conduct of a fluorescence lidar experiment, a number of parameters which can be used to optimize the SNR can be controlled. In this paper the optimum division of laser pulses centered on and off the fluorescence excitation wavelength is calculated as a function of the ratio of the fluorescence signal strength to the strength of fluorescence from interfering species. For strong interference signals the time should be divided equally on and off the line. For strong fluorescence signals the time on line is proportional to the square root of the on-line off-line signal ratio. The optimization of the integration time for varying values of signal-to-background and signal-to-interference ratios, atmospheric attenuation, laser energy variations, background measurement time, and on-line off-line time division is also considered.

Heaps, W. S.↗

Remote sensing by infrared heterodyne spectroscopy

The use of infrared heterodyne spectrocopy for the study of planetary atmospheres is discussed. Infrared heterodyne spectroscopy provides a convenient and sensitive method for measuring the true intensity profiles of atmospheric spectral lines. Application of radiative transfer theory to measured lineshapes can then permit the study of molecular abundances, temperatures, total pressures, excitation conditions, and dynamics of the regions of line formation. The theory of formation of atmospheric spectral lines and the retrieval of the information contained in these molecular lines is illustrated. Notable successes of such retrievals from infrared heterodyne measurements on Venus, Mars, Jupiter and the Earth are given. A discussion of developments in infrared heterodyne technology is also presented.

Kostiuk, T.↗

Remote sensing by IR heterodyne spectroscopy

The use of infrared heterodyne spectroscopy for the study of planetary atmospheres is discussed. Infrared heterodyne spectroscopy provides a convenient and sensitive method for measuring the true intensity profiles of atmospheric spectral lines. Application of radiative transfer theory to measured lineshapes can then permit the study of molecular abundances, temperatures, total pressures, excitation conditions, and dynamics of the regions of line formation. The theory of formation of atmospheric spectral lines and the retrieval of the information contained in these molecular lines is illustrated. Notable successes of such retrievals from infrared heterodyne measurements on Venus, Mars, Jupiter and the earth are given. A discussion of developments in infrared heterodyne technology is also presented. Previously announced in STAR as N83-28551

Kostiuk, T.↗

Use of a 35mm camera for remote surface cleanliness verification

Non-contact or remote monitoring of surfaces for both particle and molecular contaminants is required for verification of surface cleanliness on many program subsystems. The capability of a 35mm camera to satisfy this need is presented. The many limitations imposed by standard available lens systems are compared to actual required sensitivities. Methods of optimizing camera systems for specific applications and descriptions of support systems for extending the range of usefulness of the recorded data are also provided. Although this general concept is not new, significant improvements in the technique involving the use of polarized light and diffraction effects have resulted in a more efficient utilization of information recorded on the film.

Crutcher, E. R.↗

Three-dimensional trajectory analyses of two drop sizing instruments: PMS OAP and PMS FSSP

Flow induced distortions of water drop fluxes and speeds seen by the instruments were predicted by use of three dimensional flow and trajectory calculation methods. Sensitivities were determined for the instruments, in isolation and mounted under the wing of an airplane, to: water drop diameter (2 to 1000 microns), angle of attack and free stream air speed. For the optical array probe in isolation and on the airplane at 0 deg angle of attack, flux distortions of practical consequence are not found. At 4 deg airplane angle of attack, partial flow stagnation under the uptilted wing causes significant decreases in both flux and speed for cloud size droplets. For the forward scattering spectrometer probe in isolation, only marginally significant sensitivities to free stream air speed are found, and no sensitivity is found to angle of attack. Both speed and flux of cloud size droplets are predicted to be undermeasured by from 12 to 24 percent depending on airplane angle of attack. For the wing-mounted instruments, effects of flow about the instruments themselves are found to be equal in importance to effects of flow about the airplane. Preferred orientation (canting) angles of distorted water drops are found to be functions of drop size, angle of attack and air speed.

Norment, Hillyer G.↗

Protein crystal nucleation kinetics using relative light-scattering techniques: Center director's discretionary fund

Light-scattering intensity measurements are a sensitive method for following changes in the hydrodynamic radius of particles in solution. The approach used in this report utilizes the light-scattering intensity ratios of a polydisperse to a monodisperse system. By numerically modeling the process, and fitting the model curves to the data, estimates have been obtained for the dimerization equilibrium constant, the dimer + dimer yields tetramer equilibrium constant, and the association rate constant for the dimerization process.

Pusey, Marc Lee↗

Three-dimensional trajectory analyses of two drop sizing instruments - PMS OAP and PMS FSSP

Flow induced distortions of water drop fluxes and speeds seen by the instruments were predicted by use of three dimensional flow and trajectory calculation methods. Sensitivities were determined for the instruments, in isolation and mounted under the wing of an airplane, to: water drop diameter (2 to 1000 microns), angle of attack and free stream air speed. For the optical array probe in isolation and on the airplane at 0 deg angle of attack, flux distortions of practical consequence are not found. At 4 deg airplane angle of attack, partial flow stagnation under the uptilted wing causes significant decreases in both flux and speed for cloud size droplets. For the forward scattering spectrometer probe in isolation, only marginally significant sensitivities to free stream air speed are found, and no sensitivity is found to angle of attack. Both speed and flux of cloud size droplets are predicted to be undermeasured by from 12 to 24 percent depending on airplane angle of attack. For the wing-mounted instruments, effects of flow about the instruments themselves are found to be equal in importance to effects of flow about the airplane. Preferred orientation (canting) angles of distorted water drops are found to be functions of drop size, angle of attack and air speed.

Norment, Hillyer G.↗

Silane and germane plasma diagnostics for depositing photosensitive a-SiGe:H films

Highly photosensitive a-SiGe:H films with a light-to-dark conductivity ratio of 8 x 103 and an optical bandgap of 1.40 eV have been produced by RF glow discharge using hydrogen dilution of SiH4 and GeH4 mixed gas plasma. The critical role of hydrogen dilution in GeH4 containing plasmas is to suppress the gas-phase polymerization and promote the incorporation of Ge into the film. It is observed that inelastic laser light scattering of the RF plasma is a sensitive method for monitoring the onset of the gas-phase polymerization. In situ coherent anti-Stokes Raman spectroscopy measurements have shown that the dissociation rate of GeH4 is a factor of three larger than that of SiH4.

Shing, Y. H.↗

The interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces

The discovery of the cosmogenic radionuclide Be-7 on the front surface of the Long Duration Exposure Facility (LDEF) has opened new opportunities to study several unexplored regions of space science. The experiments have shown that the Be-7 found was concentrated in a thin surface layer of spacecraft material. The only reasonable source of the isotope is the atmosphere through which the spacecraft passed. It is expected that the uptake of Be in such circumstances will depend on the chemical form of the Be and the chemical nature of the substrate. It was found that the observed concentration of Be-7 does differ between metal surfaces and organic surfaces such as PTFE (Teflon). It is noted however, that (1) organic surfaces are etched by the atomic oxygen found under these orbital conditions, and (2) the relative velocity of the species is 8 km/s relative to the surface and the interaction chemistry and physics may differ from the norm. Be-7 is formed by disintegration of O and N nuclei under cosmic ray proton bombardment. Many other isotopes are produced by cosmic ray reactions, and some of these are suited to measurement by the extremely sensitive methods of accelerator mass spectrometry.

Gregory, John C.↗

The interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces

The discovery of the cosmogenic radionuclide Be-7 on the front surface (and the front surface only) of the Long Duration Exposure Facility (LDEF) spacecraft has opened opportunities to investigate new phenomena in several disciplines of space science. The experiments performed for this work show that the Be-7 results only if the source of the isotope is the atmosphere through which the spacecraft passed. We should expect that the uptake of beryllium in such circumstances will depend on the chemical form of the Be and the chemical nature of the substrate. It was found that the observed concentration of Be-7 does, in fact, differ between metal surfaces and organic surfaces such as PTFE (teflon). It is noted, however, that: (1) organic surfaces, even PTFE, are etched by the atomic oxygen found under these orbital conditions, and (2) the relative velocity of the species is 8 km(exp -1)s relative to the surface and the interaction chemistry and physics may differ from the norm. The Be-7 is formed by spallation of O and N nuclei under cosmic ray proton bombardment. The principal source region is at altitudes of 12-15 km. While very small quantities are produced above 300 km, the amount measured on the LDEF was 3 to 4 orders of magnitude higher than expected from production at orbital attitude. The most reasonable explanation is that Be-7 is rapidly transported from low altitudes by some unknown mechanism. The process must take place on a time scale similar to the half-life of the isotope (53 days). Many other isotopes are produced by cosmic ray reactions, and some of these are suited to measurement by the extremely sensitive methods of accelerator mass spectrometry. A program was initiated to search for these isotopes and it is hoped that such studies will provide new methods for studying mixing in the upper atmosphere.

Gregory, John C.↗

The interactions of atmospheric cosmogenic radionuclides with spacecraft surfaces

The discovery of the cosmogenic radionuclide Be-7 on the front surface of the Long Duration Exposure Facility (LDEF) spacecraft has opened opportunities to investigate new phenomena in several disciplines of space science. The experiments performed for this work show that the Be-7 results only if the source of the isotope is the atmosphere through which the spacecraft passed. We should expect that the uptake of beryllium in such circumstances will depend on the chemical form of the Be and the chemical nature of the substrate. It was found that the observed concentration of Be-7 does, in fact, differ between metal surfaces and organic surfaces such as PTFE (teflon). It is noted, however, that: (1) organic surfaces, even PTFE, are etched by the atomic oxygen found under these orbital conditions, and (2) the relative velocity of the species is 8 km(exp -1)s relative to the surface and the interaction chemistry and physics may differ from the norm. The Be-7 is formed by spallation of O and N nuclei under cosmic ray proton bombardment. The principal source region is at altitudes of 12-15 km. While very small quantities are produced above 300 km, the amount measured on the LDEF was 3 to 4 orders of magnitude higher than expected from production at orbital altitude. The most reasonable explanation is that Be-7 is rapidly transported from low altitudes by some unknown mechanism. The process must take place on a time scale similar to the half-life of the isotope (53 days). Many other isotopes are produced by cosmic ray reactions, and some of these are suited to measurement by the extremely sensitive methods of accelerator mass spectrometry. A program was initiated to search for these isotopes and it is hoped that such studies will provide new methods for studying mixing in the upper atmosphere.

Gregory, J. C.↗

Diode injection - seeded, 940 nanometer (nm), titanium - sapphire laser for H2O DIAL (differential absorption lidar), measurements

Differential absorption of laser radiation by various molecular species represents both a selective and a sensitive method of measuring specific atmospheric constituents. DIAL measurements can be carried out via two different means. Both involve using two laser pulses with slightly different wavelengths (lambda), (one lambda at a strong absorption line of the molecule of interest, the other detuned into the wing of the line), and comparing the attenuation of the pulses. One approach relies on scattering of the radiation from some conveniently located topographical target. In the other technique elastic scattering from atmospheric aerosols and particulates is used to return the radiation to the lidar receiver system. This case is referred to as the differential absorption and scattering technique, and is the technique we are interested in to measure water vapor at 940 nm. The 940 nm wavelength is extremely desirable to atmospheric scientist interested in accurate DIAL measurements of H2O in the upper and lower troposphere. Simulated measurements using approximately 940 nm and 815 nm lasers at a range of altitudes and experimental conditions are shown. By offering access to larger absorption cross-sections, injected seeded, 940 nm DIAL laser transmitters would allow for more accurate water profile measurements at altitudes from 6 to 16 km than is currently possible with 730 nm and 815 nm DIAL laser transmitters. We have demonstrated the operation of an injected seeded titanium-sapphire (TS) laser operating at approximately 940 nm with an energy of more than 90 mJ per pulse. The TS laser is pumped by a commercial, 600 mJ, 532 nm, 10 Hz Nd:YAG laser. The slope efficiency of the laser using a flat 50 percent R output coupler and a 10 m end-mirror is shown. The laser was injected seeded with a CW, AlGaAs, semiconductor diode laser which had an output of 83 mW. The CW diode seed beam was introduced into the TS laser cavity through a HR end-mirror. When the diode beam is aligned to the TS resonator, it controls the TS laser output wavelength and its spectral line width with the required resolution for DIAL applications. This work supports the need for the development of 940 nm, titanium-sapphire DIAL transmitters.

Miller, George E.↗

On the rms anisotropy at 7 deg and 10 deg observed in the COBE-DMR two year sky maps

The frequency-independent rms temperature fluctuations determined from the Cosmic Background Explorer-Differential Microwave Radiometer (COBE-DMR) two-year sky maps are used to infer the parameter Q(sub rms-PS), which characterizes the normalization of power-law models of primordial cosmological temperature anisotropy, for a forced fit to a scale-invariant Harrison-Zel'dovich (n = 1) spectral model. Using a joint analysis of the 7 deg and 10 deg 'cross'-rms derived from both the 53 and 90 GHz sky maps, we find Q(sub rms-PS) = 17.0(sub -2.1 sup +2.5) micro Kelvin when the low quadrupole is included, and Q(sub rms-PS) = 19.4(sub -2.1 sup +2.3) micro Kelvin excluding the quadrupole. These results are consistent with the n = 1 fits from more sensitive methods. The effect of the low quadrupole derived from the COBE-DMR data on the inferred Q(sub rms-PS) normalization is investigated. A bias to lower Q(sub rms-PS) is found when the quadrupole is included. The higher normalization for a forced n = 1 fit is then favored by the cross-rms technique.

Banday, A. J.↗