Search NASA⌕ Search

SEARCH · Search NASA

Results for “sequential experimental design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Subcritical Copper-Reflected-α-phase Plutonium (SCRαP) Integral Experiment Design

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)

42 ENGINEERING↗

Design, modeling and experimental validation of a micro cantilever beam with an electro-controllable twisting ability

The structure design of micro cantilever beams (MCBs), which has a significant effect on MCBs' controllable actuation range, is usually restricted by the establishment of the inner electric circuit. This paper proposes the design of a micro electro-controllable twisting cantilever beam (METCB). The architecture and the fabrication diagram of the proposed METCB are presented before its features are theoretically and experimentally validated. In detail, the analytical validation includes a sequence of two models: electro-thermal and thermo-mechanical. Through these two models, the thermal distribution along the METCB and the deformation brought by the thermal distribution are investigated, respectively. On the basis of the design and equations, the METCB samples have been manufactured using a planar deposition technique with an e-beam evaporator. Two in-site experiments are then conducted to sequentially figure out the upper voltage limit of the inner electric circuit and the maximum temperature limit of the METCB. Finally, another experiment is carried out to explore the relation between the applied voltage and the relative twisting angle of the METCB sample. Here, the theoretical prediction and the observed experiment result both prove the feasibility of the proposed METCB and its electro-controllable twisting ability.

36 MATERIALS SCIENCE↗

Universal scheme for finite-probability perfect transfer of arbitrary multispin states through spin chains

In combination with the theories of open system and quantum recovering measurement, we propose a quantum state transfer scheme using spin chains by performing two sequential operations: a projective measurement on the spins of ‘environment’ followed by suitably designed quantum recovering measurements on the spins of interest. The scheme allows perfect transfer of arbitrary multispin states through multiple parallel spin chains with finite probability. Our scheme is universal in the sense that it is state-independent and applicable to any model possessing spin–spin interactions. We also present possible methods to implement the required measurements taking into account the current experimental technologies. As applications, we consider two typical models for which the probabilities of perfect state transfer are found to be reasonably high at optimally chosen moments during the time evolution. - Highlights: • Scheme that can achieve perfect quantum state transfer is devised. • The scheme is state-independent and applicable to any spin-interaction models. • The scheme allows perfect transfer of arbitrary multispin states. • Applications to two typical models are considered in detail.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automating Bayesian inference and design to quantify acoustic particle levitation

Self-propulsion of micro- and nanoparticles powered by ultrasound provides an attractive strategy for the remote manipulation of colloidal matter using biocompatible energy inputs. Quantitative understanding of particle motion and its dependence on size, shape, and composition requires accurate characterization of the acoustic field, which depends sensitively on the experimental setup. Here, we show how automated experiments based on Bayesian inference and design can accurately and efficiently characterize the acoustic field within resonant chambers used to propel acoustic nanomotors. Repeated cycles of observation, inference, and design (OID) are guided by a physical model that describes the rate at which levitating particles approach the nodal plane. Using video microscopy, we observe the relaxation of tracer particles to this plane following the application of the acoustic field. We use sequential Monte Carlo methods to infer model parameters such as the amplitude and frequency of the resonant chamber while accounting for particle-level measurement noise and population-level heterogeneity in the field. Guided by simulated outcomes, we select the optimal design for the next experiment as to maximize the information gain in the relevant parameters. We show how this iterative process serves to discriminate between competing hypotheses and efficiently converges to accurate parameter estimates using only few automated experiments. We discuss the need for model criticism to ensure the validity of the guiding model throughout automated cycles of observation, inference, and design. Furthermore, this work demonstrates how Bayesian methods can learn the parameters of nonlinear, hierarchical models used to describe video microscopy data of active colloids.

42 ENGINEERING↗

Light-Induced Charge Separation in Photosystem I from Different Biological Species Characterized by Multifrequency Electron Paramagnetic Resonance Spectroscopy

Photosystem I (PSI) serves as a model system for studying fundamental processes such as electron transfer (ET) and energy conversion, which are not only central to photosynthesis but also have broader implications for bioenergy production and biomimetic device design. In this study, we employed electron paramagnetic resonance (EPR) spectroscopy to investigate key light-induced charge separation steps in PSI isolated from several green algal and cyanobacterial species. Following photoexcitation, rapid sequential ET occurs through either of two quasi-symmetric branches of donor/acceptor cofactors embedded within the protein core, termed the A and B branches. Using high-frequency (130 GHz) time-resolved EPR (TR-EPR) and deuteration techniques to enhance spectral resolution, we observed that at low temperatures prokaryotic PSI exhibits reversible ET in the A branch and irreversible ET in the B branch, while PSI from eukaryotic counterparts displays either reversible ET in both branches or exclusively in the B branch. Furthermore, we observed a notable correlation between low-temperature charge separation to the terminal [4Fe-4S] clusters of PSI, termed F A and F B , as reflected in the measured F A /F B ratio. These findings enhance our understanding of the mechanistic diversity of PSI’s ET across different species and underscore the importance of experimental design in resolving these differences. Though further research is necessary to elucidate the underlying mechanisms and the evolutionary significance of these variations in PSI charge separation, this study sets the stage for future investigations into the complex interplay between protein structure, ET pathways, and the environmental adaptations of photosynthetic organisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid Piston with Spray Cooling Near-Isothermal Compressor

The goal of this project was to prototype and characterize the performance of a liquid-piston spray-cooled gas compressor. The working principle of the compressor enables optimized high-efficiency operation over a very wide range of operating conditions, unlike conventional compressors that are optimized for a narrow range of operating conditions. The compressor technology is suitable for many applications, such as gas pipeline transport, gas storage, and commercial and residential heat pumps. Both physical testing and computational fluid dynamics (CFD) modeling of the processes using the Oak Ridge National Laboratory high-performance computing center were completed. The experimental and CFD studies focused on a near-isothermal liquid-piston compressor (LPC) that uses propylene glycol to compress CO 2 . The first prototype demonstrated isothermal operation during several sequentially executed cycles of CO 2 compression and raised the temperature of the compressed CO 2 by only 2 K, compared with approximately 6 K when the gas was compressed non-isothermally. Isothermal operation was demonstrated at CO 2 flow rates of up to 2 L/min. The second prototype was designed with two compression chambers to allow continuous flow of high-pressure CO 2 . However, the design of the valve train to direct flow between the compression chambers was not sufficient to allow demonstration of CO 2 compression. Numerical simulations of the LPC in which the compression chamber was filled with propylene glycol injected from the bottom inlet were performed using large eddy simulation (LES) with the wall-adapting local eddy-viscosity subgrid-scale model coupled with the multiphase volume of fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfers within the compression chamber. In this effort, the effects of boundary conditions applied to the LES-VOF calculations (i.e., no wall, an adiabatic wall, and a wall with a heat flux subscribed) on the overall pressure and temperature of the CO 2 gas as well as the transient evolution of flow and heat transfer within the compression chamber were investigated and are discussed in this report. The LES calculation with no wall showed no dynamical flow patterns, and the volume-averaged temperature of CO 2 increased from 305 to 392.7 K, whereas LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO 2 temperatures. The results of the LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO 2 gas layers and circulation flow patterns within the chamber that contributed to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor. Though an industrial partnership for commercializing the compressor was not secured, the technology was attractive for an industrial partner to use in two research proposals in response to US Department of Energy funding opportunity announcements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co,N-codoped graphene as efficient electrocatalyst for hydrogen evolution reaction: Insight into the active centre

Co and N co-doped carbon (CNC) material is one of the most promising precious-metal-free catalyst for hydrogen evolution reaction (HER), however, widespread application of CNC will require continuous innovation and optimization of fabrication to maximize electrocatalytic performance, which is always a challenge. Herein, two types of three-dimensional (3D) graphene materials synthesized by one-step of simultaneous doping (Co,N/3DG-1) and two-step of sequential doping (Co,N/3DG-2) respectively, are evaluated and correlated their electrocatalytic activity for HER with experimental parameters. The results indicate that Co,N/3DG-2 exhibits significantly better electrocatalytic activity than Co,N/3DG-1. The structure analysis reveals that Co,N/3DG-2 has more moderate Co-N coordinated number than Co,N/3DG-1. Density functional theory calculations unravels that the equilibrium C and N around Co atom is more favorable to the adsorption and desorption of hydrogen. In conclusion, the results shed new light on the rational design of dual hetero-atom co-doped carbon materials, which may be applicable to other energy conversion and storage systems.

electrocatalyst↗

Sequential data assimilation for single-molecule FRET photon-counting data

Data assimilation is a statistical method designed to improve the quality of numerical simulations in combination with real observations. Here, we develop a sequential data assimilation method that incorporates one-dimensional time-series data of smFRET (single-molecule Förster resonance energy transfer) photon-counting into conformational ensembles of biomolecules derived from “replicated” molecular dynamics (MD) simulations. A particle filter using a large number of “replicated” MD simulations with a likelihood function for smFRET photon-counting data is employed to screen the conformational ensembles that match the experimental data. We examine the performance of the method using emulated smFRET data and coarse-grained (CG) MD simulations of a dye-labeled polyproline-20. The method estimates the dynamics of the end-to-end distance from smFRET data as well as revealing that of latent conformational variables. The particle filter is also able to correct model parameter dependence in CG MD simulations. We discuss the applicability of the method to real experimental data for conformational dynamics of biomolecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraint Optimization Problem For The Cutting Of A Cobalt Chrome Refractory Material

This paper shows a complete approach to solve a given problem, from the experimentation to the optimization of different cutting parameters. In response to an industrial problem of slotting FSX 414, a Cobalt-based refractory material, we have implemented a design of experiment to determine the most influent parameters on the tool life, the surface roughness and the cutting forces. After theses trials, an optimization approach has been implemented to find the lowest manufacturing cost while respecting the roughness constraints and cutting force limitation constraints. The optimization approach is based on the Response Surface Method (RSM) using the Sequential Quadratic programming algorithm (SQP) for a constrained problem. To avoid a local optimum and to obtain an accurate solution at low cost, an efficient strategy, which allows improving the RSM accuracy in the vicinity of the global optimum, is presented. With these models and these trials, we could apply and compare our optimization methods in order to get the lowest cost for the best quality, i.e. a satisfying surface roughness and limited cutting forces.

36 MATERIALS SCIENCE↗

Imaging single-molecule reaction intermediates stabilized by surface dissipation and entropy

Chemical transformations at the interface between solid/liquid or solid/gaseous phases of matter lie at the heart of key industrial-scale manufacturing processes. A comprehensive study of the molecular energetics and conformational dynamics that underlie these transformations is often limited to ensemble-averaging analytical techniques. In this paper we report the detailed investigation of a surface-catalysed cross-coupling and sequential cyclization cascade of 1,2-bis(2-ethynyl phenyl)ethyne on Ag(100). Using non-contact atomic force microscopy, we imaged the single-bond-resolved chemical structure of transient metastable intermediates. Theoretical simulations indicate that the kinetic stabilization of experimentally observable intermediates is determined not only by the potential-energy landscape, but also by selective energy dissipation to the substrate and entropic changes associated with key transformations along the reaction pathway. Finally, the microscopic insights gained here pave the way for the rational design and control of complex organic reactions at the surface of heterogeneous catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

A new spectrometer design for the x-ray spectroscopy of laser-produced plasmas with high (sub-ns) time resolution

This paper describes a new type of x-ray crystal spectrometer, which can be used in combination with gated x-ray detectors to obtain spectra from laser-produced plasmas with a high (sub-ns) time resolution. The spectrometer consists of a convex, spherically bent crystal, which images individual spectral lines as perfectly straight lines across multiple, sequentially gated, strip detectors. Since the Bragg-reflected rays are divergent, the distance between detector and crystal is arbitrary, so that this distance can be appropriately chosen to optimize the experimental arrangement with respect to the detector parameters. The spectrometer concept was verified in proof-of-principle experiments by imaging the Lβ{sub 1}- and Lβ{sub 2}-lines of tungsten, at 9.6735 and 9.96150 keV, from a micro-focus x-ray tube with a tungsten target onto a two-dimensional pixilated Pilatus detector, using a convex, spherically bent Si-422 crystal with a radius of curvature of 500 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stabilizing a strongly nonlinear structure through shaker dynamics in fixed frequency voltage control tests

Bifurcations are commonly encountered during force controlled swept and stepped sine testing of nonlinear structures, which generally leads to the so-called jump-down or jump-up phenomena between stable solutions. There are various experimental closed-loop control algorithms, such as control-based continuation and phase-locked loop, to stabilize dynamical systems through these bifurcations, but they generally rely on specialized control algorithms that are not readily available with many commercial data acquisition software packages. A recent method was developed to experimentally apply sequential continuation using the shaker voltage that can be readily deployed using commercially available software. By utilizing the stabilizing effects of electrodynamic shakers and the force dropout phenomena in fixed frequency voltage control sine tests, this approach has been demonstrated to stabilize the unstable branch of a nonlinear system with three branches, allowing for three multivalued solutions to be identified within a specific frequency bandwidth near resonance. Recent testing on a strongly nonlinear system with vibro-impact nonlinearity has revealed jumping behavior when performing sequential continuation along the voltage parameter, like the jump phenomena seen during more traditional force controlled swept and stepped sine testing. Here, this paper investigates the stabilizing effects of an electrodynamic shaker on strongly nonlinear structures in fixed frequency voltage control tests using both numerical and experimental methods. The harmonic balance method is applied to the coupled shaker-structure system with an electromechanical model to simulate the fixed voltage control tests and predict the stabilization for different parameters of the model. The simulated results are leveraged to inform the design of a set of experiments to demonstrate the stabilization characteristics on a fixture-pylon assembly with a vibro-impact nonlinearity. Through numerical simulation and experimental testing on two different strongly nonlinear systems, the various parameters that influence the stability of the coupled shaker-structure are revealed to better understand the performance of fixed frequency voltage control tests.

42 ENGINEERING↗

Thermophilic Chassis-Enabled High-Throughput Selection of a Thermostable Fluorogenic Reporter

Thermostable proteins show increased shelf life and performance at elevated temperatures and under harsh conditions, resulting in lower costs for various industrial and biotechnological applications. However, due to a limited understanding of the relationship between stability and function, protein stabilization remains primarily a trial-and-error approach. Therefore, building a combinatorial library of mutations predicted to improve stability, followed by experimental testing, represents a markedly improved methodology. However, the lack of high-throughput approaches to screen even a moderately sized library presents a major bottleneck in the field. Here, in this study, we use a thermophile, Parageobacillus thermoglucosidasius (Ptherm) to rapidly screen combinatorial libraries consisting of rationally designed thermostabilizing mutations (∼10 3 –10 4 ) of a mesophilic fluorescent reporter, Y-FAST. On a Petri dish, microbial growth at an elevated temperature and exposure to fluorogen yielded several colonies of Ptherm that showed distinct fluorescence at 55 and 68 °C in our two sequentially generated libraries using Rosetta and ProteinMPNN, respectively. The Y-FAST variants isolated from fluorescent colonies were brighter than Y-FAST and showed higher resistance to thermal and chemical denaturation. AlphaFold-predicted structures and MD simulations revealed stability-enhancing salt bridges and hydrogen bond networks in the isolated FAST variants. The moderately thermostable FAST (tsFAST) and hyperstable FAST (hsFAST) were then demonstrated as translation reporters for protein expression and folding at elevated temperatures, such as 55 and 68 °C. Our approach of combinatorial library generation and high-throughput screening in a thermophilic chassis could, in principle, be extended to other proteins fused to these translation reporters. Furthermore, the hsFAST protein is small─half the size of the green fluorescent protein─and does not require oxygen for maturation, making it ideal for engineering extremophilic anaerobes for biosensing and bioconversion.

59 BASIC BIOLOGICAL SCIENCES↗

A non-cooperative meta-modeling game for automated third-party calibrating, validating and falsifying constitutive laws with parallelized adversarial attacks

The evaluation of constitutive models, especially for high-risk and high-regret engineering applications, requires efficient and rigorous third-party calibration, validation and falsification. While there are numerous efforts to develop paradigms and standard procedures to validate models, difficulties may arise due to the sequential, manual, and often biased nature of the commonly adopted calibration and validation processes, thus slowing down data collections, hampering the progress towards discovering new physics, increasing expenses and possibly leading to misinterpretations of the credibility and application ranges of proposed models. This work attempts to introduce concepts from game theory and machine learning techniques to overcome many of these existing difficulties. Here, we introduce an automated meta-modeling game where two competing AI agents systematically generate experimental data to calibrate a given constitutive model and to explore its weakness such that the experiment design and model robustness can be improved through competitions. The two agents automatically search for the Nash equilibrium of the meta-modeling game in an adversarial reinforcement learning framework without human intervention. In particular, a protagonist agent seeks to find the more effective ways to generate data for model calibrations, while an adversary agent tries to find the most devastating test scenarios that expose the weaknesses of the constitutive model calibrated by the protagonist. By capturing all possible design options of the laboratory experiments into a single decision tree, we recast the design of experiments as a game of combinatorial moves that can be resolved through deep reinforcement learning by the two competing players. Our adversarial framework emulates idealized scientific collaborations and competitions among researchers to achieve a better understanding of the application range of the learned material laws and prevent misinterpretations caused by conventional AI-based third-party validation. Numerical examples are given to demonstrate the wide applicability of the proposed meta-modeling game with adversarial attacks on both human-crafted constitutive models and machine learning models.

97 MATHEMATICS AND COMPUTING↗

Experimental and computational analysis of bending fatigue failure in chopped carbon fiber chip reinforced composites

With a better balance among good mechanical performance, high freedom of design, and low material and manufacturing cost, chopped carbon fiber chip reinforced sheet molding compound (SMC) composites show great potential in different engineering applications. Here in this paper, bending fatigue behaviors of SMC composites considering the heterogeneous fiber orientation distributions have been thoroughly investigated utilizing both experimental and computational methods. First, four-point bending fatigue tests are performed with designed SMC composites, and the local modulus is adopted as a metric to represent the local fiber orientation of two opposing sides. Interestingly, SMC composites with and without large discrepancy in local modulus of opposing sides show different fatigue behaviors. Interrupted tests are conducted to explore the bending fatigue failure mechanism, and the damage processes of valid specimens are also closely examined. We find that the fatigue failure of SMC composites under four-point bending is governed by crack propagation instead of crack initiation. Because of this, the heterogeneous local fiber orientations of both sides of the specimen influence fatigue life. The microstructure of the lower side shows a direct influence while that of the upper side also exhibiting influence which becomes more prominent for high cycle fatigue cases. Furthermore, a hybrid micro–macro computational model is proposed to efficiently study the cyclic bending behavior of SMC composites. The region of interest is reconstructed with a modified random sequential absorption algorithm to conserve all the microstructural details including the heterogeneous fiber orientation, while the rest of the regions are modeled as homogenized macro-scale continua. Combined with a framework to capture the progressive fatigue damage under cyclic bending, the bending fatigue behaviors of SMC composites are accurately captured by the hybrid computational model comparing with our experimental analysis.

36 MATERIALS SCIENCE↗

The Effect of Tissue Inhomogeneities on the Accuracy of Proton Path Reconstruction for Proton Computed Tomography

Maintaining a high degree of spatial resolution in proton computed tomography (pCT) is a challenge due to the statistical nature of the proton path through the object. Recent work has focused on the formulation of the most likely path (MLP) of protons through a homogeneous water object and the accuracy of this approach has been tested experimentally with a homogeneous PMMA phantom. Inhomogeneities inside the phantom, consisting of, for example, air and bone will lead to unavoidable inaccuracies of this approach. The purpose of this ongoing work is to characterize systematic errors that are introduced by regions of bone and air density and how this affects the accuracy of proton CT in surrounding voxels both in terms of spatial and density reconstruction accuracy. Phantoms containing tissue-equivalent inhomogeneities have been designed and proton transport through them has been simulated with the GEANT 4.9.0 Monte Carlo tool kit. Various iterative reconstruction techniques, including the classical fully sequential algebraic reconstruction technique (ART) and block-iterative techniques, are currently being tested, and we will select the most accurate method for this study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗