Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral line-shape in collinear laser spectroscopy after atomic charge exchange

Collinear laser spectroscopy experiments on fast, neutral beams have been extensively used for studies on short-lived radioactive nuclei, taking advantage of its high sensitivity. The resulting resonance line-shape is known to show significant distortion, due to the energy exchange during the charge-exchange neutralization process, which can cause large systematic uncertainty in the determined centroid. A model for the line shape was constructed and simulated to be compared to measured Al, Si, and Ni hyperfine spectra. It is shown that the distortion is caused mainly by the transfer of electron into many different energy levels in the projectile atom and subsequent decays, rather than secondary inelastic collisions, which were often assumed in the line shape analysis before. Furthermore, the model can also be applied to other projectile–alkali pairs, providing a reliable line-shape with less fitting parameters than conventional phenomenological models.

Atom↗

Lyman-$α$ forest holography: 3D predictions from 1D measurements

Cosmological analyses of Lyman-$α$ forest clustering rely on either one-dimensional correlations along individual sightlines or three-dimensional correlations between different sightlines. Because these observables probe the matter distribution on very different scales, they have traditionally been analyzed independently. In this work, we bridge this gap using ForestFlow, an emulator trained on a suite of cosmological hydrodynamical simulations that provides a unified description of Lyman-$α$ forest clustering from linear to nonlinear scales. This framework enables us to determine the range of three-dimensional clustering models compatible with the DESI one-dimensional flux power spectrum ($P_{\rm 1D}$). The resulting predictions successfully reproduce the large-scale clustering measured by the DESI BAO analysis and provide physically motivated priors on nonlinear clustering that are used in a companion paper presenting the full-shape analysis of the DESI DR2 Lyman-$α$ forest. We validate our methodology using the large-volume, high-resolution hydrodynamical simulation ACCEL-2, demonstrating excellent agreement across the full range of scales considered. Finally, we combine constraints from the $P_{\rm 1D}$ and BAO analyses on the parameter combinations $b_δσ_8$ and $b_ηf σ_8$, finding that the two probes provide comparable constraining power while exhibiting complementary parameter degeneracies. Our results establish a direct connection between one- and three-dimensional Lyman-$α$ forest measurements through ForestFlow, an approach we term Lyman-$α$ holography by analogy with the reconstruction of higher-dimensional structure from lower-dimensional information.

Chaves-Montero, J. [Barcelona, IFAE] (ORCID:000000↗

High-resolution Compton spectroscopy using x-ray microcalorimeters

X-ray Compton spectroscopy is one of the few direct probes of the electron momentum distribution of bulk materials in ambient and operando environments. Herein, we report high-resolution inelastic x-ray scattering experiments with high momentum and energy transfer performed at a storage-ring-based high-energy x-ray light source facility using an x-ray transition-edge sensor (TES) microcalorimeter detector. The performance was compared with a silicon drift detector (SDD), an energy-resolving semiconductor detector, and Compton profiles were measured for lithium and cobalt oxide powders relevant to lithium-ion battery research. Spectroscopic analysis of the measured Compton profiles demonstrates the high-sensitivity to the low- Z elements and oxidation states. The line shape analysis of the measured Compton profiles in comparison with computed Hartree–Fock profiles is usually limited by the resolution of the semiconductor detector. We have characterized an x-ray TES microcalorimeter detector for high-resolution Compton scattering experiments using a bending magnet source at the Advanced Photon Source with a double crystal monochromator, providing monochromatic photon energies near 27.5 keV. The momentum resolution below 0.16 atomic units (a.u.) was measured, yielding an improvement of more than a factor of 7 over a state-of-the-art SDD for the same scattering geometry. Furthermore, the lineshapes of narrow valence and broad core electron profiles of sealed lithium metal were clearly resolved using an x-ray TES compared to smeared and broadened lineshapes observed when using the SDD. High-resolution Compton scattering using the energy-resolving area detector shown here presents new opportunities for spatial imaging of electron momentum distributions for a wide class of materials with applications ranging from electrochemistry to condensed matter physics.

47 OTHER INSTRUMENTATION↗

A low energy rare event search with the MAJORANA DEMONSTRATOR

The MAJORANA DEMONSTRATOR is sensitive to rare events near its energy threshold, including bosonic dark matter, solar axions, and lightly ionizing particles. In this analysis, a novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of pulse shape analysis cuts, and we present updated bosonic dark matter and solar axion results from an 11.17 kg-y dataset using a 5 keV analysis threshold.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of collagen I and fibronectin on the adhesion, elasticity and cytoskeletal organization of prostate cancer cells

Research highlights: {yields} Depending on the metastatic origin, prostate cancer cells differ in their affinity to COL1. {yields} COL1 affects specifically the F-actin and cell elasticity of bone-derived prostate cancer cells. {yields} Cell elasticity can be used as a biomarker for cancer cells from different metastases. -- Abstract: Despite of intensive research efforts, the precise mechanism of prostate cancer metastasis in bone is still not fully understood. Several studies have suggested that specific matrix production by the bone cells, such as collagen I, supports cancer cell invasion. The aim of this study was to investigate the effect of collagen I (COL1) and fibronectin (FN) on cell adhesion, cell elasticity and cytoskeletal organization of prostate cancer cells. Two cell lines, bone marrow- (PC3) and lymph node-derived (LNCaP) were cultivated on COL1 and FN (control protein). By using a quantitative adhesion assay and time-lapse analysis, it was found that PC3, but not LNCaP, adhered strongly and were more spread on COL1. Next, PC3 and LNCaP were evaluated by atomic force microscopy (AFM) and flatness shape factor and cellular Young's modulus were calculated. The shape analysis revealed that PC3 were significantly flatter when grown on COL1 in comparison to LNCaP. In general, PC3 were also significantly stiffer than LNCaP and furthermore, their stiffness increased upon interaction with COL1. Since cell stiffness is strongly dependent on actin organization, phalloidin-based actin staining was performed and revealed that, of the two cell types as well as the two different matrix proteins, only PC3 grown on COL1 formed robust actin cytoskeleton. In conclusion, our study showed that PC3 cells have a strong affinity towards COL1. On this matrix protein, the cells adhered strongly and underwent a specific cell flattening. Moreover, with the establishment of PC3 contact to COL1 a significant increase of PC3 stiffness was observed due to a profound cytoskeletal rearrangement.

60 APPLIED LIFE SCIENCES↗

Accurate measurement of porosity size and morphology in aluminium alloy laser welds

Conventional two-dimensional optical microscopy is the most common tool for capturing and quantifying keyhole collapse porosity and other defects formed during the laser welding of aluminium alloys. This approach is of limited utility since only a single longitudinal or transverse metallographic cross-section, comprising only a small fraction of the overall weld volume, can be extracted or analysed at a time. X-ray computed tomography tools, on the other hand, enable three-dimensional visualisation and analysis of porosity and defects to be made across the full weld volume. When comparing these two measurement techniques, two-dimensional microscopy tools significantly underestimated the fraction of defects present within the weld at levels between 50% and 80%. Three-dimensional x-ray computed tomography tools also provide a means for accurately characterising the location, size and morphology of irregularly shaped defects. By categorising the defect shapes using a Zingg's shape analysis, in which the distribution of defect morphologies could be quantified as disk, rod and spherical shapes, a transition in defect morphology moving from stationary beam to oscillating beam welds was detected and quantified.

36 MATERIALS SCIENCE↗

Defect and satellite characteristics of additive manufacturing metal powders

Metal additive manufacturing (AM) requires high-quality metal powders to three-dimensionally (3D) print metallic components with complex and customizable geometries. The lack of quantification of AM metal powders creates quality control challenges for 3D printed components, increases the uncertainty of printing reliability and net cost of inspected and certified printed components, and reduces the recyclability of used powders. However, critical characteristics of AM metal powders that are decisive factors for the 3D printing process, such as internal porosity, contamination, and satellite feature, remain ambiguous. In this work, we developed a novel approach to 3D quantify key characteristics of AM metal powders down to individual particles by using high-resolution synchrotron x-ray computed tomography. Empowered by the penetrative capability of high-energy x-ray, internal porosity and contamination within as-atomized metal powders from high-entropy alloys to nickel-based superalloys were evaluated. Additionally, the newly-developed dispersion method enables the homogeneous separation of individual particles, and consequently, results in the implementation of 3D particle shape analysis. To resolve a major challenge of identification and quantification of satellite-feature particles in as-atomized AM metal powders, the satellite features were quantitated by modeling and analyzing the shape parameter of local thickness variance. Furthermore, the 3D analytical methods of particle assessment in this study can be applied to other materials systems like rock, food, and pharmaceutical particles, and provide insights for process optimization across powder metallurgy, concrete, food and pharmaceutical manufacturing, and AM industries.

36 MATERIALS SCIENCE↗

DEFECT DETECTION USING DYNAMIC ANALYSIS FOR ADDITIVE MANUFACTURED METALS

Additive manufacturing (AM) has the ability to produce parts with complex geometries and internal features, however, for demanding applications such as the automotive and aerospace industries, it is crucial that the parts can meet the demanding functional and geometric requirements. Quality control for AM parts focuses on nondestructive methods of testing, but many of the current methods are expensive and time-consuming. The research presented in this report explores various methods of nondestructive evaluation (NDE) using dynamic analysis on stainless steel parts produced with selective laser melting (SLM). Methods include, but are not limited to, frequency response functions (FRF), impedance-based measurements, and scanning laser doppler vibrometry. Additionally, mode shape analysis was performed in MATLAB and FEA simulations were used for comparison with experimental results. The results indicate that dynamic analysis has the potential to be a feasible method of defect detection and NDE in AM parts and future work should focus on refining these methods, such as optimizing test parameters to improve sensitivity to defects.

Deonarain, Gita↗

Probing the Dynamics of a Protein Hydrophobic Core by Deutron Solid-State Nuclear Magnetic Resonance Spectroscopy

With the goal of investigating dynamical features of hydrophobic cores of proteins over a wide range of temperatures, the villin headpiece subdomain protein (HP36) was labeled at a "single" site corresponding to any one of the two -C5D3 groups of Leucine-69, which is located in a key position of the core. The main techniques employed are deuteron NMR quadrupolar echo line shape analysis, and T1Z (Zeeman) and T1Q (Quadrupolar order) relaxation experiments performed at 11.7 and 17.6T over the temperature range of 112 to 298K. The experimental data are compared with computer simulations. The deuteron line shapes give an excellent fit to a three-mode motional model that consists of a) fast 3-site rotational jumps about the pseudo C3 methyl spinning axis, b) slower reorientation of the spinning axis, described by diffusion along a restricted arc and c) large angle jumps between traces of rotameric conformers. Relaxation behavior is described by a phenomenological distribution of activation energies for 3-site hops at high temperatures that collapses to a single, distinctly smaller value for lower temperatures.

59 BASIC BIOLOGICAL SCIENCES↗

Re-description and Reassignment of the Damselfish Abudefduf luridus (Cuvier, 1830) Using Both Traditional and Geometric Morphometric Approaches

Here we present a re-description of Abudefduf luridus and reassign it to the genus Similiparma. We supplement traditional diagnoses and descriptions of this species with quantitative anatomical data collected from a family-wide geometric morphometric analysis of head morphology (44 species representing all 30 damselfish genera) and data from cranial micro-CT scans of fishes in the genus Similiparma. The use of geometric morphometric analyses (and other methods of shape analysis) permits detailed comparisons between the morphology of specific taxa and the anatomical diversity that has arisen in an entire lineage. This provides a particularly useful supplement to traditional description methods and we recommend the use of such techniques by systematists. Similiparma and its close relatives constitute a branch of the damselfish phylogenetic tree that predominantly inhabits rocky reefs in the Atlantic and Eastern Pacific, as opposed to the more commonly studied damselfishes that constitute a large portion of the ichthyofauna on all coral-reef communities.

59 BASIC BIOLOGICAL SCIENCES↗

Multisite event discrimination for the majorana demonstrator

The MAJORANA DEMONSTRATOR is searching for neutrinoless double-beta decay($0\nu\beta\beta$) in 76 Ge using arrays of point-contact germanium detectors operating at the Sanford Underground Research Facility. Background results in the $0\nu\beta\beta$ region of interest from data taken during construction, commissioning, and the start of full operations have been recently published. A pulse shape analysis cut applied to achieve this result, named AvsE , is described in this paper. This cut is developed to remove events whose waveforms are typical of multi-site energy deposits while retaining (90 ± 3.5)% of single-site events. This pulse shape discrimination is based on the relationship between the maximum current and energy, and tuned using 228 Th calibration source data. In conclusion, the efficiency uncertainty accounts for variation across detectors, energy, and time, as well as for the position distribution difference between calibration and $0\nu\beta\beta$ events, established using simulations.

59 ≤ A ≤ 89↗

Investigation of the neutron response anisotropy in crystalline organic scintillators.

An anisotropy in the response of crystalline organic scintillators such as anthracene to neutron elastic scattering interactions has been known for some time. Both the amplitude and the time structure of the scintillation light pulse vary with the direction of the proton recoil with respect to the crystalline axes. In principle, this effect could be exploited to develop compact, high-efficiency fast neutron detectors that have directional sensitivity via a precise measurement of the pulse shape. We are investigating the feasibility and sensitivity of such a detector, particularly for neutrons in the fission energy spectrum. Here we will report new measurements of the pulse shape dependence on proton recoil angle in anthracene and stilbene single crystals, for proton energies in the few MeV range. Digital pulse acquisition and processing are used to allow an exploration of different pulse shape analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of the EMCCD point-source response using x-rays

Electron Multiplying Charge Coupled Devices, EMCCD are used as x-ray detectors. The NSLS-II Soft Inelastic x-ray Scattering (SIX) beam line has two EMCCDs for x-ray detection in the spectrometer arm. The spectrometer with high resolving power disperses x-rays vertically. The x-ray vertical position on the sensor plane is related to its energy. This allows for very accurate x-ray energy measurements through x-ray coordinates. X-rays interact with silicon and create a number of electron-hole pairs proportional to the x-ray energy. Electrons drift and diffuse toward pixel gates and are collected there. The diffused electrons form a charge cloud distributed over several neighboring pixels. This charge sharing enables coordinate measurements with accuracy better than the pixel pitch. The charge distribution shape has to be taken into account to achieve ultimate accuracy in coordinate measurements. In this paper, we present a method of the charge distribution shape analysis and demonstrate its applications. The drift and diffusion of electrons ftom the point of generation to pixel gates results in the bell-shaped electron cloud usually approximated by Gaussian shape. The number of electrons collected under a pixel is proportional to the shape function integral. These electron packets get transferred to the sense node of the output amplifier. The transfer process could introduce distortions to the original charge distribution. For example, during transfers, electrons in the packet could be exposed to traps if they are present in the sensor. The trapping and later the release processes distort the apparent shape of the charge distribution. Therefore, deviations of the charge distribution shape ftom the originally symmetrical form can indicate the presence of trap centers in the sensor and can be used for sensor diagnostics.

47 OTHER INSTRUMENTATION↗

High-Resolution X-Ray Study of Nematic-Smectic-A And Smectic-A-Reentrant-Nematic Transitions in Liquid-Crystal-Aerosil Gels

We have studied the effects of quenched random disorder created by dispersed aerosil nanoparticle gels on the nematic to smectic- A (N- SmA ) and smectic- A to reentrant nematic ( SmA -RN) phase transitions of thermotropic liquid-crystal mixtures of hexyloxycyanobiphenyl (6OCB) and octyloxycyanobiphenyl (8OCB). These effects are probed using high-resolution synchrotron x-ray diffraction techniques. We find that the reentrant characteristics of the system are largely unchanged by the presence of the aerosil gel network. By comparing measurements of the smectic static structure amplitude for this 8OCB- 6OCB+aerosil system with those for butyloxybenzilidene-octylaniline (4O.8)+aerosil gels, we find that the short-range smectic order in the smectic- A phase is significantly weaker in the reentrant system. This result is consistent with the behavior seen in pure 8OCB-6OCB mixtures. The strength of the smectic ordering decreases progressively as the 6OCB concentration is increased. Detailed line shape analysis shows that the high- and low-temperature nematic phases (N and RN) are similar to each other.

43 PARTICLE ACCELERATORS↗

Electron scattering, charge order, and pseudogap physics in La 1.6–x Nd 0.4 Sr x CuO 4 : An angle-resolved photoemission spectroscopy study

We report an angle-resolved photoemission study of the charge stripe ordered La 1.6–x Nd 0.4 Sr x CuO 4 (Nd-LSCO) system. A comparative and quantitative line-shape analysis is presented as the system evolves from the overdoped regime into the charge ordered phase. On the overdoped side (x = 0.20), a normal-state antinodal spectral gap opens upon cooling below 80 K. In this process, spectral weight is preserved but redistributed to larger energies. A correlation between this spectral gap and electron scattering is found. A different line shape is observed in the antinodal region of charge ordered Nd-LSCO x = 1/8. Significant low-energy spectral weight appears to be lost. As a result, these observations are discussed in terms of spectral-weight redistribution and gapping originating from charge stripe ordering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurment and energy correction due to charge carrier lifetimes in large HPGe spectrometers

This work addresses the energy spectrum correction due to increased charge carrier collection times in larger HPGe spectrometers. The energy of the radiation interaction is expected to be proportional to the total collected charge. This is increasingly not true with larger HPGe spectrometers. Some charge is lost as the total charge travels from the interaction location to the collection electrode. This path dependent loss of charge results in decreased energy resolution. In HPGe spectrometers, this process is characterized by the charge carrier lifetime constant and is given as an exponential function of the charge carrier collection time divided by this constant. Thus large detectors can experience exponential decrease in energy resolution as charge carrier collection time increases. We study the effect of charge carrier lifetime on energy resolution for a large diameter p-type coaxial and p-type point contact HPGe spectrometers using pulse shape analysis. We present a method to measure the charge carrier lifetime for a given HPGe spectrometer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Nuclear Fission Investigation with Twin Ionization Chamber

The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗