At least 91 records · Page 5

Building a Large Scale Climate Data System in Support of HPC Environment

The Earth System Grid Federation (ESG) is a large scale, multi-institutional, interdisciplinary project that aims to provide climate scientists and impact policy makers worldwide a web-based and client-based platform to publish, disseminate, compare and analyze ever increasing climate related data. This paper describes our practical experiences on the design, development and operation of such a system. In particular, we focus on the support of the data lifecycle from a high performance computing (HPC) perspective that is critical to the end-to-end scientific discovery process. We discuss three subjects that interconnect the consumer and producer of scientific datasets: (1) the motivations, complexities and solutions of deep storage access and sharing in a tightly controlled environment; (2) the importance of scalable and flexible data publication/population; and (3) high performance indexing and search of data with geospatial properties. These perceived corner issues collectively contributed to the overall user experience and proved to be as important as any other architectural design considerations. Although the requirements and challenges are rooted and discussed from a climate science domain context, we believe the architectural problems, ideas and solutions discussed in this paper are generally useful and applicable in a larger scope.

54 ENVIRONMENTAL SCIENCES↗

Distributed control system for parallel-connected DC boost converters

The disclosed invention is a distributed control system for operating a DC bus fed by disparate DC power sources that service a known or unknown load. The voltage sources vary in v-i characteristics and have time-varying, maximum supply capacities. Each source is connected to the bus via a boost converter, which may have different dynamic characteristics and power transfer capacities, but are controlled through PWM. The invention tracks the time-varying power sources and apportions their power contribution while maintaining the DC bus voltage within the specifications. A central digital controller solves the steady-state system for the optimal duty cycle settings that achieve a desired power supply apportionment scheme for a known or predictable DC load. A distributed networked control system is derived from the central system that utilizes communications among controllers to compute a shared estimate of the unknown time-varying load through shared bus current measurements and bus voltage measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Modular Design in Abatement of Fuel Element Debris (FED) Liquid Waste Stream - 16635

This paper provides a description of the processes applied within the Aqueous Discharge Abatement Plant (ADAP) at Bradwell nuclear power plant in the UK. This incorporates the Fuel Element Debris (FED) abatement plant and the Modular Active Effluent Treatment Plant (MAETP). These plants are housed in adjacent, but separate, structures and are inter-linked and share common services and control systems. The FED abatement plant, which has a shorter mission than MAETP, can be removed for decommissioning or redeployment without any impact to MAETP operation. ADAP treats aqueous waste streams generated during the ongoing decontamination and decommissioning (D and D) operations for release from the Bradwell Power Station. The plant is designed to receive and treat two major classes of liquids: 1. Slightly contaminated water from various D and D sources and collected rainwater from the power station, referred to as Aqueous Effluent (AE). 2. Dissolved fuel element debris solution. This comprises of contaminated magnesium alloy (generated during the stripping of external structures from spent Magnox fuel elements prior to shipment for reprocessing) which has been dissolved in nitric acid. All received wastes are treated to remove heavy metals and radioactive constituents prior to isolation, sampling, verification, and ultimately release to the Blackwater Estuary. The treatment consists of multiple processes including precipitation, filtration, adsorption and ion exchange carefully designed to remove targeted radionuclides and heavy metals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for safely sharing dual-use genetic data

Background: Some genetic data has dual-use potential. Sharing pathogen data has shown tremendous value. For example therapeutic development and lineage tracking during the COVID pandemic. This data sharing is complicated by the fact that these data have the potential to be used for harm. The genome sequence of a pathogen can be used to enable malicious genetic engineering approaches or to recreate the pathogen from synthetic DNA. Standard data security methods can be applied to genetic data, but when data is shared between institutions, ensuring appropriate security can be difficult. Sensitive data that is shared internationally among a wide array of institutions can be especially difficult to control. Methods for securely storing and sharing genetic data with potential for dual-use are needed to mitigate this potential harm.Results: Here we propose new methods that allow genetic data to be shared in a data format that prevents a nefarious actor from accessing sensitive aspects of the data. Our methods obfuscate raw sequence data by pooling reads from different samples. This approach can ensure that data is secure while stored and during electronic transfer. We demonstrate that by pooling raw sequence data from multiple samples of the same organism, the ability to fully reconstruct any individual sample is prevented. In the pooled data, most genomic information remains, but reads or mutations cannot be directly attributed to any individual sample. To further restrict access to information, regions of a genome can be removed from the reads.Conclusion: Our methods obscure genomic information within raw sequence reads. This method can allow genetic data to be stored and shared while preventing a nefarious actor from being able to perfectly reconstruct an organism. Broad-scale sequence information remains, while fine scale details about specific samples are difficult or impossible to reconstruct. Our software is available at https://github.com/Geneinfosec-Inc/ReadMixer.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding the Charging Flexibility of Shared Automated Electric Vehicle Fleets

The combined anticipated trends of vehicle sharing (ride-hailing), automated control, and powertrain electrification are poised to disrupt the current paradigm of predominately owner-driven gasoline vehicles with low levels of utilization. Shared, automated, electric vehicle (SAEV) fleets offer the potential for lower cost and emissions and have garnered significant interest among the research community. While promising, unmanaged operation of these fleets may lead to unintended negative consequences. One potentially unintended consequence is a high quantity of SAEVs charging during peak demand hours on the electric grid, potentially increasing the required generation capacity. This research explores the flexibility associated with charging loads demanded by SAEV fleets in response to servicing personal mobility travel demands. Travel demand is synthesized in four major United States metropolitan areas: Detroit, MI; Austin, TX; Washington, DC; and Miami, FL. In each of these four cities, SAEV simulations are performed using local projected electricity prices from the Regional Energy Deployment System (ReEDS) for a handful of supply side scenarios. A coordinated charging model is introduced that seeks to reduce fleet charging costs in response to time-varying electricity prices and increasing shares of personal trip demand served (between 1% and 25% of all metro trips served by the SAEV fleet). Simulation results are presented across various scenarios assuming fleetwide coordination to minimize charging energy costs while constrained by offering adequate mobility service to fleet customers. The results indicate that the SAEV charging load is highly flexible; energy costs were shown to reduce between 13% and 46% across a wide range of simulated scenarios. In addition, these savings were realized without detrimentally impacting the fleet’s ability to service trips.

autonomous vehicle↗

Microfabricated linear Paul-Straubel ion trap

An array of microfabricated linear Paul-Straubel ion traps can be used for mass spectrometric applications. Each ion trap comprises two parallel inner RF electrodes and two parallel outer DC control electrodes symmetric about a central trap axis and suspended over an opening in a substrate. Neighboring ion traps in the array can share a common outer DC control electrode. The ions confined transversely by an RF quadrupole electric field potential well on the ion trap axis. The array can trap a wide array of ions.

47 OTHER INSTRUMENTATION↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

A widespread family of serine/threonine protein phosphatases shares a common regulatory switch with proteasomal proteases

PP2C phosphatases control biological processes including stress responses, development, and cell division in all kingdoms of life. Diverse regulatory domains adapt PP2C phosphatases to specific functions, but how these domains control phosphatase activity was unknown. We present structures representing active and inactive states of the PP2C phosphatase SpoIIE from Bacillus subtilis. Based on structural analyses and genetic and biochemical experiments, we identify an α-helical switch that shifts a carbonyl oxygen into the active site to coordinate a metal cofactor. Our analysis indicates that this switch is widely conserved among PP2C family members, serving as a platform to control phosphatase activity in response to diverse inputs. Remarkably, the switch is shared with proteasomal proteases, which we identify as evolutionary and structural relatives of PP2C phosphatases. Although these proteases use an unrelated catalytic mechanism, rotation of equivalent helices controls protease activity by movement of the equivalent carbonyl oxygen into the active site.

59 BASIC BIOLOGICAL SCIENCES↗

A Supervised Machine Learning Approach to Control Energy Storage Devices

This paper introduces a supervised machine learning approach to predict and schedule the real-time operation mode of the next operation interval for residential PV/Battery systems controlled by mode-based controllers. The performance of the mode-based economic model-predictive control (EMPC) approach is used as the benchmark. The residential load and PV data used in the paper are 1-minute data downloaded from the the Pecan Street Project website. The optimal operation mode for each control interval is first derived from the historical data used as the training set. Then, four machine learning algorithms (i.e. neural network, support vector machine, logistic regression, and random forest algorithms) are applied. We compared the performance of the four algorithms when using different number of features and length of the training sets extracted from different months of the year. Simulation results show that using the machine learning approach can effectively improve the performance of the mode-based control system and reduce the computation effort of local controllers because the training can be completed on a cloud-based Machine Learning engine. Furthermore, the work presented in this paper paves the way for using a shared-learning platform to design controllers of residential PV/storage systems. This may significantly reduce the cost for implementing such systems.

25 ENERGY STORAGE↗

Analysis of Power-Maximizing Region 2 Controllers for Wind and Marine Turbines

Wind and marine energy are rapidly growing and complementary technologies that share some techniques for simplified modeling and control, particularly in below-rated flow speeds. A turbine operator has several choices of controller for maximizing power in Region 2. The simple and ubiquitous KΩ 2 control law is often effective but limited in its flexibility. Alternative controllers use reference tracking to split the control objectives into a low-bandwidth optimal tip-speed ratio tracking loop to maximize steady-state power and a higher-bandwidth proportional-integral control loop to reject inflow turbulence. Several options exist for identifying the slowly varying optimal set point during operation, based on estimating the inflow velocity or filtering the power or torque signals. This study compares the trade-offs between performance and other design priorities for a few choices of reference-tracking controller in the literature for reference wind and marine turbines. Analysis is performed in the frequency domain using the linearization of each controller, and the impact of turbulent disturbances on the closed-loop system is described. The controllers are simulated in OpenFAST to analyze their performance with higher-order nonlinear turbine dynamics.

17 WIND ENERGY↗

Control systems and data management for high-power laser facilities

The next generation of high-power lasers enables repetition of experiments at orders of magnitude higher frequency than what was possible using the prior generation. Facilities requiring human intervention between laser repetitions need to adapt in order to keep pace with the new laser technology. A distributed networked control system can enable laboratory-wide automation and feedback control loops. These higher-repetition-rate experiments will create enormous quantities of data. A consistent approach to managing data can increase data accessibility, reduce repetitive data-software development and mitigate poorly organized metadata. An opportunity arises to share knowledge of improvements to control and data infrastructure currently being undertaken. We compare platforms and approaches to state-of-the-art control systems and data management at high-power laser facilities, and we illustrate these topics with case studies from our community

47 OTHER INSTRUMENTATION↗

Dynamic Boundary Microgrids Under Privatization Considerations

Microgrids have physical, electrical, and logical (data, network, and ownership) boundaries. To power unserved customer loads during an outage, microgrids can extend the traditional operational boundaries. This can become complex when considering microgrid-to-microgrid (M2M) interactions where sensitive information such as competitive microgrid operational data is not shared. This work proposes an optimization method coordinated between microgrid controllers and distribution management systems that limits data sharing. The method involves a competitive bidding strategy that maximizes unserved load coverage while minimizing resource utilization and sensitive operational data sharing among entities. The work is validated on a two-microgrid system with photovoltaic and energy storage systems and curves of load derived from real world residential buildings datasets. Results show that the proposed method, when applied for three distinct use cases of energy storage sufficiency to cover the predefined boundary and/or the expanded boundary, can successfully select and bid the available load coverage.

Starke, Michael [ORNL] (ORCID:0000000221211195)↗

Data Storage and sharing for the long tail of science

Research data infrastructure such as storage must now accommodate new requirements resulting from trends in research data management that require researchers to store their data for the long term and make it available to other researchers. We propose Data Depot, a system and service that provides capabilities for shared space within a group, shared applications, flexible access patterns and ease of transfer at Purdue University. We evaluate Depot as a solution for storing and sharing multiterabytes of data produced in the long tail of science with a use case in soundscape ecology studies from the Human- Environment Modeling and Analysis Laboratory. We observe that with the capabilities enabled by Data Depot, researchers can easily deploy fine-grained data access control, manage data transfer and sharing, as well as integrate their workflows into a High Performance Computing environment.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Load Shedding for Voltage Regulation With Probabilistic Agent Compliance

With the increased observability and controllability of distribution systems, the share of behind-the-meter systems is trending upwards rapidly. As a consequence, the impact of human behaviors on system performance can no longer be ignored and should be reflected in the energy management system models. In this paper, we discuss the problem of distribution system voltage control by active power curtailment where the agent compliance of the load curtailment signal is probabilistic. We discuss the modeling of the optimal voltage control problem with probabilistic agent compliance as a chance-constrained optimization problem, its tractable safe approximation using convex restriction, and a scenario-based mixed-integer reformulation as well as the associated solution method based on augmented Lagrangian method. The numerical simulation on IEEE test system validates the effectiveness of the proposed approach in obtaining high-quality feasible load curtailment signal with low computational cost, which makes it a viable tool for real time decision making.

augmented Lagrangian method↗

Marine algae and land plants share conserved phytochrome signaling systems

Phytochrome photosensors control a vast gene network in streptophyte plants, acting as master regulators of diverse growth and developmental processes throughout the life cycle. In contrast with their absence in known chlorophyte algal genomes and most sequenced prasinophyte algal genomes, a phytochrome is found in Micromonas pusilla , a widely distributed marine picoprasinophyte (<2 µm cell diameter). Together with phytochromes identified from other prasinophyte lineages, we establish that prasinophyte and streptophyte phytochromes share core light-input and signaling-output domain architectures except for the loss of C-terminal response regulator receiver domains in the streptophyte phytochrome lineage. Phylogenetic reconstructions robustly support the presence of phytochrome in the common progenitor of green algae and land plants. These analyses reveal a monophyletic clade containing streptophyte, prasinophyte, cryptophyte, and glaucophyte phytochromes implying an origin in the eukaryotic ancestor of the Archaeplastida. Transcriptomic measurements reveal diurnal regulation of phytochrome and bilin chromophore biosynthetic genes in Micromonas . The expression of these genes precedes both light-mediated phytochrome redistribution from the cytoplasm to the nucleus and increased expression of photosynthesis-associated genes. Prasinophyte phytochromes perceive wavelengths of light transmitted farther through seawater than the red/far-red light sensed by land plant phytochromes. Prasinophyte phytochromes also retain light-regulated histidine kinase activity lost in the streptophyte phytochrome lineage. Our studies demonstrate that light-mediated nuclear translocation of phytochrome predates the emergence of land plants and likely represents a widespread signaling mechanism in unicellular algae.

59 BASIC BIOLOGICAL SCIENCES↗

Isochronous Architecture-Based Voltage-Active Power Droop for Multi-Inverter Systems

This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article shows that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗

Community-Controlled Transportation: The Western New York E-Bike Library Network: Preprint

Shared Mobility Inc. (SMI) has used their mission of community-controlled transportation to partner with community based organizations on the launch and operations of E-Bike Libraries (EBLs) in Western New York (WNY) and beyond since 2021. For almost four years, the WNY EBLs have provided e-bikes at no cost to underserved communities in Buffalo and Niagara Falls. Participants used the e-bikes for commuting, recreational rides, community bike rides, running errands, and accessing essential services. This program significantly increased e-bike accessibility, with 71% of participants being first-time riders and 78% identifying as Black/African American. Challenges such as bike maintenance, battery charging logistics, and the need for suitable storage were addressed through partnerships with community-based organizations and adjustments to program logistics. Those lessons have been applied to additional EBLs in Pacoima, California and Carlisle, Pennsylvania, which have also been launched by SMI with a continued emphasis on the importance of community based approaches to sustainable transportation. All of these programs demonstrate the potential of e-bikes to provide an affordable, efficient, and fun transportation option, particularly for underserved communities. By leveraging community partnerships and focusing on accessibility and inclusivity, E-Bike Libraries can significantly contribute to sustainable transportation solutions and promote broader participation in the transportation electrification revolution.

33 ADVANCED PROPULSION SYSTEMS↗