Search NASA⌕ Search

SEARCH · Search NASA

Results for “single event upset results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Open Source Radiation Hardened by Design Technology

The proposed technology allows use of the latest microcircuit technology with lowest power and fastest speed, with minimal delay and engineering costs, through new Radiation Hardened by Design (RHBD) techniques that do not require extensive process characterization, technique evaluation and re-design at each Moore's Law generation. The separation of critical node groups is explicitly parameterized so it can be increased as microcircuit technologies shrink. The technology will be open access to radiation tolerant circuit vendors. INNOVATION: This technology would enhance computation intensive applications such as autonomy, robotics, advanced sensor and tracking processes, as well as low power applications such as wireless sensor networks. OUTCOME / RESULTS: 1) Simulation analysis indicates feasibility. 2)Compact voting latch 65 nanometer test chip designed and submitted for fabrication -7/2016. INFUSION FOR SPACE / EARTH: This technology may be used in any digital integrated circuit in which a high level of resistance to Single Event Upsets is desired, and has the greatest benefit outside low earth orbit where cosmic rays are numerous.

Shuler, Robert↗

Virtex-II Pro PowerPC SEE Characterization Test Methods and Results

The Xilinx Vix-11 Pro is a platform FPGA that embeds multiple microprocessors within the fabric of an SRAM-based reprogrammable FPGA. The variety and quantity of resources provided by this family of devices make them very attractive for spaceflight applications. However,these devices will be susceptible to single event effects (SEE), which must be mitigated. Observations from prior testing of the Xilinx Virtex-II Pro suggest that the PowerPC core has significant vulnerability to SEES. However, these initial tests were not designed to exclusively target the functionality of the PowerPC, therefore making it difficult to distinguish processor upsets from fabric upsets. The main focus of this paper involves detailed SEE testing of the embedded PowerPC core. Due to the complexity of the PowerPC, various custom test applications, both static and dynamic, will be designed to isolate each Unit of the processor. Collective analysis of the test results will provide insight into the exact upset mechanism of the PowerPC. With this information, mitigations schemes can be developed and tested that address the specific susceptibilities of these devices. The test bed will be the Xilinx SEE Consortium Virtex-II Pro test board, which allows for configuration scrubbing, design triplication, and ease of data collection. Testing will be performed at the Indiana University Cyclotron Facility using protons of varying energy levels and fluencies. This paper will present the detailed test approach along with the results.

Petrick, David↗

Empirical modeling of Single-Event Upset (SEU) in NMOS depletion-mode-load static RAM (SRAM) chips

A detailed experimental investigation of single-event upset (SEU) in static RAM (SRAM) chips fabricated using a family of high-performance NMOS (HMOS) depletion-mode-load process technologies, has been done. Empirical SEU models have been developed with the aid of heavy-ion data obtained with a three-stage tandem van de Graaff accelerator. The results of this work demonstrate a method by which SEU may be empirically modeled in NMOS integrated circuits.

Zoutendyk, J. A.↗

SEU In An Advanced Bipolar Integrated Circuit

Report summarizes investigation of single-event upsets (SEU) in bipolar integrated-circuit set of flip-flops (memory cells). Device tested made by advanced digital bipolar silicon process of Honeywell, Inc. Circuit chip contained 4 cells. Construction enabled study of effect of size on SEU behavior. Each cell externally biased so effect of bias current on SEU behavior. Results of study provides important information for optimal design of devices fabricated using buried-layer bipolar process operating in heavy-ion SEU environments. Designers use information to provide required levels of suppression of SEU in specific applications via combinations of size and/or cell-current scaling.

Zoutendyk, John A.↗

Charge, energy, and LET spectra measurements of charged particles in P0006 experiment of LDEF

Measurements are under way of the charged particle radiation environment of the LDEF satellite using stacks of plastic nuclear track detectors (PNTDs) placed in different locations of the satellite. In the initial work, the charge, energy, and linear energy transfer (LET) spectra of charged particles were measured with CR-39 double layer PNTDs located on the west end of the satellite. Primary and secondary stopping heavy ions as well as relativistic galactic cosmic rays (mostly iron particles) were measured separately. The results will be compared with similar measurements in other locations on LDEF with different orientation and shielding conditions. The remarkably detailed study of the charged particle radiation environment of the LDEF satellite will lead to a better understanding of the radiation environment of the Space Station Freedom. It will enable more accurate prediction of single event upsets (SEUs) in microelectronics and, especially, more accurate assessment of the risk, contributed by the different components of the radiation field to the health and safety of crew members.

Benton, E. V.↗

Radiation Mitigation and Power Optimization Design Tools for Reconfigurable Hardware in Orbit

The Reconfigurable Hardware in Orbit (RHinO)project is focused on creating a set of design tools that facilitate and automate design techniques for reconfigurable computing in space, using SRAM-based field-programmable-gate-array (FPGA) technology. In the second year of the project, design tools that leverage an established FPGA design environment have been created to visualize and analyze an FPGA circuit for radiation weaknesses and power inefficiencies. For radiation, a single event Upset (SEU) emulator, persistence analysis tool, and a half-latch removal tool for Xilinx/Virtex-II devices have been created. Research is underway on a persistence mitigation tool and multiple bit upsets (MBU) studies. For power, synthesis level dynamic power visualization and analysis tools have been completed. Power optimization tools are under development and preliminary test results are positive.

French, Matthew↗

Multiple single event upsets in CMOS static rams

The occurrence of multiple upset errors during ground tests can contaminate the data and lead to error cross sections which are too high. In space, multiple errors may produce higher upsets than predicted and if they occur in single words they can defeat error detection and correction hardware. This investigation involves data which were taken during an experimental study of dose imprint effects in static memories. The results show that multiple errors occurred mainly for heavy ions with high linear energy transfers and with the majority of these in the soft upset sections of the dose-imprinted memory samples. The percentages of the total number of errors which were singles, doubles, and triplets, were determined as a function of LET, dose, and soft or hard section of the devices. The experimental observations are compared to the predictions of simple binomial statistics.

Stassinopoulos, E. G.↗

Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

Single Event Effects↗

LET spectra measurements of charged particles in the P0006 experiment on LDEF

Measurements are under way of the charged particle radiation environment of the Long Duration Exposure Facility (LDEF) satellite using stacks of plastic nuclear track detectors (PNTD's) placed in different locations of the satellite. In the initial work the charge, energy, and linear energy transfer (LET) spectra of charged particles were measured with CR-39 double layer PNTD's located on the west side of the satellite (Experiment P0006). Primary and secondary stopping heavy ions were measured separately from the more energetic particles. Both trapped and galactic cosmic ray (GCR) particles are included, with the latter component being dominated by relativistic iron particles. The results from the P0006 experiment will be compared with similar measurements in other locations on LDEF with different orientation and shielding conditions. The remarkably detailed investigation of the charged particle radiation environment of the LDEF satellite will lead to a better understanding of the radiation environment of the Space Station Freedom. It will enable more accurate prediction of single event upsets (SEU's) in microelectronics and, especially, more accurate assessment of the risk - contributed by different components of the radiation field (GCR's, trapped protons, secondaries and heavy recoils, etc.) - to the health and safety of crew members.

Benton, E. V.↗

An Examination of Environment Perturbation Effects on Single Event Upset Rates

This paper presents an analysis of the sensitivity of single event upset (SEU) rate predictions to changes in the direct ionization-inducing environment. An examination based on the nature of the SEU rate equation is presented for the case in which the perturbation is constant across varying particle linear energy transfer (LET). It is shown that the relative variation in SEU rate is equal to the relative perturbation in flux. Results are also presented for the case in which the environment perturbations exist in small LET bins. Through this analysis it is shown that the relative variation in expected SEU rate is equal to that in flux only for the LET regime in which the product of the cross section and differential flux is maximum.

Gates, Michele M.↗

Variation in SEU sensitivity of dose-imprinted CMOS SRAMs

The authors report on an experimental study of dose-induced changes in SEU (single-event-upset) sensitivity of CMOS static RAMs. Two time regimes were investigated following exposure of memories to cobalt-60 gamma rays: the near term, within a few hours after exposure, and the long term, after many days. Samples were irradiated both at room and at liquid nitrogen temperatures. The latter procedure was used in order to freeze in the damage state until SEU measurements could be made prior to annealing. Results show that memories damaged by dose are more sensitive to upsets by heavy ions. The induced changes are substantial: threshold linear energy transfer (LET) values decreased by as much as 46 percent and asymptotic cross sections increased by factors of two to four (unannealed samples).

Stassinopoulos, E. G.↗

Experimental determination of single-event upset (SEU) as a function of collected charge in bipolar integrated circuits

Single-Event Upset (SEU) in bipolar integrated circuits (ICs) is caused by charge collection from ion tracks in various regions of a bipolar transistor. This paper presents experimental data which have been obtained wherein the range-energy characteristics of heavy ions (Br) have been utilized to determine the cross section for soft-error generation as a function of charge collected from single-particle tracks which penetrate a bipolar static RAM. The results of this work provide a basis for the experimental verification of circuit-simulation SEU modeling in bipolar ICs.

Zoutendyk, J. A.↗

NASA Engineering and Safety Center Technical Bulletins 2007-2023

An NESC Technical Bulletin captures critical knowledge in the form of new engineering information or best practices in a one-page format that have resulted from NESC independent testing, analysis, and assessments. This document contains all NESC Technical Bulletins from 2007 through 2023.

additive manufacturing, battery, braycote, capacit↗

Single-Event Upset (SEU) model verification and threshold determination using heavy ions in a bipolar static RAM

Single-Event Upset (SEU) response of a bipolar low-power Schottky-diode-clamped TTL static RAM has been observed using Br ions in the 100-240 MeV energy range and O ions in the 20-100 MeV range. These data complete the experimental verification of circuit-simulation SEU modeling for this device. The threshold for onset of SEU has been observed by the variation of energy, ion species and angle of incidence. The results obtained from the computer circuit-simulation modeling and experimental model verification demonstrate a viable methodology for modeling SEU in bipolar integrated circuits.

Zoutendyk, J. A.↗

Single Event Effects Test Results for the Actel ProASIC Plus and Altera Stratix-II Field Programmable Gate Arrays

This work describes radiation testing of Actel's ProASIC Plus and Altera's Stratix-II FPGAs. The Actel Device Under Test (DUT) was a ProASIC Plus APA300-PQ208 nonvolatile, field reprogrammable device which is based on a 0.22micron flash-based LVCMOS technology. Limited investigation has taken place into flash based FPGA technologies, therefore this test served as a preliminary reference point for various SEE behaviors. The Altera DUT was a Stratix-II EP2S60F1020C4. Single Event Upset (SEU) and Single Event Latchup (SEL) were the focus of these studies. For the Actel, a latchup test was done at an effective LET of 75.0 MeV-sq cm/mg at room temperature, and no latchup was detected when irradiated to a total fluence of 1 x 10(exp 7) particles/sq cm. The Altera part was shown to latchup at room temperature.

heavy ions↗

Single Event Effects Testing of the Linfinity SG1525A Pulse Width Modulator Controller

Pulse Width Modulator (PWM) Controllers are the heart of switching power supply systems in development today. The PWMs considered here have the same integration advantages as many other controllers but it also includes the interface drivers for the follow-on power Field Effect Transistors (FET). Previous work on these types of devices looked into the required test methodologies [ 11 and the impact of radiation on the soft start and shutdown circuits of typically incorporated in the technology [2]. Taking advantage of this previous work this study was undertaken to determine the single event destructive and transient susceptibility of the Linfinity SG1525A Pulse Width Modulator Controller. The device was monitored for transient interruptions in the output signals and for destructive events induced by exposing it to a heavy ion beam at the Texas A&M University Cyclotron Single Event Effects Test Facility. After exposing these devices to the beam, a new upset mode has been identified that can lead to catastrophic power supply system failure if this event would occur while drive power FETs off the two device outputs. The devices and the test methods used will be described first. This will be followed by a brief description of the data collected to date (not all data can be presented with the length constraints of the summary) and a summary of the key results.

Howard, J. W., Jr.↗

Comparison of single event upset rates for microelectronic memory devices during interplanetary solar particle events

Variability in the methods and models used for single event upset calculations in microelectronic memory devices can lead to a range of possible upset rates. Using heavy ion and proton data for selected DRAM and SRAM memories, we have calculated an array of upset rates in order to compare the Adams worst case interplanetary solar flare model to a model proposed by scientists at the Jet Propulsion Laboratory. In addition, methods of upset rate calculation are compared: the Cosmic Ray Effects on Microelectronics CREME code and a Monte Carlo algorithm developed at the Applied Physics Laboratory. The results show that use of a more realistic, although still conservative, model of the space environment can have significant cost saving benefits.

Mckerracher, P. L.↗

Virtex-II Pro SEE Test Methods and Results

The Xilinx Virtex-II Pro is a platform FPGA that embeds multiple microprocessors within the fabric of an SRAM-based reprogrammable FPGA. The variety and quantity of resources provided by this family of devices make them very attractive for spaceflight applications. However, these devices will be susceptible to single event effects (SEE), which must be mitigated. To use the Virtex-II Pro reliably in space applications, these devices must first be tested to determine if they are susceptible to single event latchup (SEL), the degree to which they are susceptible to single event upsets (SEU) and single event transients (SET), and how these effects are manifested in the device. With this information, mitigations schemes can be developed and tested that address the specific susceptiblities of these devices. This initial SEE test uses a commercial off the shelf Virtex-II Pro evaluation board, with a single processor XC2VP7 FPGA. The FPGA on this board is an acid etched device, which can be partially covered with a shield. The shield covers a portion of the logic, routing, and memory resources along with some of the RocketIO transceivers. The processor, along with a large portion of logic, routing, memory, and transceivers are left exposed. This test will be performed at the Cyclotron Laboratories at Texas A&M University and Michigan State University using ions of varying energy levels and fluencies.

Petrick, David↗