Search NASA⌕ Search

SEARCH · Search NASA

Results for “single image velocity measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fuzzy Logic Particle Tracking

A new all-electronic Particle Image Velocimetry technique that can efficiently map high speed gas flows has been developed in-house at the NASA Lewis Research Center. Particle Image Velocimetry is an optical technique for measuring the instantaneous two component velocity field across a planar region of a seeded flow field. A pulsed laser light sheet is used to illuminate the seed particles entrained in the flow field at two instances in time. One or more charged coupled device (CCD) cameras can be used to record the instantaneous positions of particles. Using the time between light sheet pulses and determining either the individual particle displacements or the average displacement of particles over a small subregion of the recorded image enables the calculation of the fluid velocity. Fuzzy logic minimizes the required operator intervention in identifying particles and computing velocity. Using two cameras that have the same view of the illumination plane yields two single exposure image frames. Two competing techniques that yield unambiguous velocity vector direction information have been widely used for reducing the single-exposure, multiple image frame data: (1) cross-correlation and (2) particle tracking. Correlation techniques yield averaged velocity estimates over subregions of the flow, whereas particle tracking techniques give individual particle velocity estimates. For the correlation technique, the correlation peak corresponding to the average displacement of particles across the subregion must be identified. Noise on the images and particle dropout result in misidentification of the true correlation peak. The subsequent velocity vector maps contain spurious vectors where the displacement peaks have been improperly identified. Typically these spurious vectors are replaced by a weighted average of the neighboring vectors, thereby decreasing the independence of the measurements. In this work, fuzzy logic techniques are used to determine the true correlation displacement peak even when it is not the maximum peak, hence maximizing the information recovery from the correlation operation, maintaining the number of independent measurements, and minimizing the number of spurious velocity vectors. Correlation peaks are correctly identified in both high and low seed density cases. The correlation velocity vector map can then be used as a guide for the particle-tracking operation. Again fuzzy logic techniques are used, this time to identify the correct particle image pairings between exposures to determine particle displacements, and thus the velocity. Combining these two techniques makes use of the higher spatial resolution available from the particle tracking. Particle tracking alone may not be possible in the high seed density images typically required for achieving good results from the correlation technique. This two-staged velocimetric technique can measure particle velocities with high spatial resolution over a broad range of seeding densities.

Source record↗

Intercontinental Bistatic Radar Test Observation of Asteroid 1998 WT24

We describe the first intercontinental planetary radar test performed in Italy observing the near Earth asteroid (NEA) 33342 (1998 WT24) in December 2001 by means of the bistatic configurations Goldstone (California, USA)-Medicina (Italy) and Evpatoria (Ukraine)-Medicina. The experiment goal was to characterize the system for realtime radar follow-up observations of NEAs and artificial orbiting debris, in the framework of a feasibility study which aims at using the Sardinia Radio Telescope, at present under construction, also as a planetary radar facility. We report the preliminary results of the radar observations carried out by the IRA-CNR (Instituto di Radioastronomia - Consiglio Nazionale delle Ricerche) and the OATo (Osservatorio Astronomico di Torino) groups, aimed at exploring the scientific potentials of a new space radar program, using the existing facilities in Italy. The planetary radar technique is uniquely capable of investigating geometry and surface properties of various solar system objects, demonstrating advantages over the optical methods in its high spatial resolution and ability to obtain three-dimensional images. A single radar detection allows to obtain extremely accurate orbital elements, improving the instantaneous positional uncertainties by orders of magnitude with respect to an optically determined orbit. Radar is a powerful means to spatially resolve NEAs by measuring the distribution of the echo power in time delay (range) and Doppler frequency (line-of-sight velocity) with extreme precision in each coordinate, as it provides detailed information about the target physical properties like size, shape, rotation, near-surface bulk density and roughness and internal density distribution. The Medicina 32m antenna had been successfully used for the first time as the receiving part of a bistatic configuration during a test experiment (September 2001) held to check the capabilities of the entire data acquisition system. This test was possible thanks to the collaboration undertaken with the Evpatoria radar station, and consisted in the observation of the ETALON-1 low orbit satellite

Righini, S.↗

Dotted-line FLEET for two-component velocimetry

Femtosecond laser electronic excitation tagging (FLEET) is a powerful unseeded velocimetry technique typically used to measure one component of velocity along a line, or two or three components from a dot. In this Letter, we demonstrate a dotted-line FLEET technique which combines the dense profile capability of a line with the ability to perform two-component velocimetry with a single camera on a dot. Our set-up uses a single beam path to create multiple simultaneous spots, more than previously achieved in other FLEET spot configurations. We perform dotted-line FLEET measurements downstream of a highly turbulent, supersonic nitrogen free jet. Dotted-line FLEET is created by focusing light transmitted by a periodic mask with rectangular slits of 1.6 × 40 mm 2 and an edge-to-edge spacing of 0.5 mm, then focusing the imaged light at the measurement region. Up to seven symmetric dots spaced approximately 0.9 mm apart, with mean full-width at half maximum diameters between 150 and 350 µm, are simultaneously imaged. Both streamwise and radial velocities are computed and presented in this Letter.

47 OTHER INSTRUMENTATION↗

Spherical harmonic analysis of steady photospheric flows. II

The use of the spherical harmonic functions to analyze the nearly steady flows in the solar photosphere is extended to situations in which B(0) the latitude at disk center, is nonzero and spurious velocities are present. The procedures for extracting the rotation profile and meridional circulation are altered to account for the seasonal tilt of the sun's rotation axis toward and away from the observer. A more robust and accurate method for separating the limb shift and meridional circulation signals is described. The analysis procedures include the ability to mask out areas containing spurious velocities (velocity-like signals that do not represent true flow velocities in the photosphere). The procedures are shown to work well in extracting the various flow components from realistic artificial data with a broad, continuous spectrum for the supergranulation. The presence of this supergranulation signal introduces errors of a few m/s in the measurements of the rotation profile, meridional circulation, and limb shift from a single Doppler image.

Hathaway, David H.↗

Flow and Performance Characterization of Rotating Detonation Combustor Integrated with Various Convergent Nozzles

In this study, convergent nozzles of various area ratios (ARs) are used downstream of an annular rotating detonation combustor (RDC) to increase the operating pressure and approach sonic conditions at the nozzle throat. Reactant methane and oxygen-enriched air (67% [Formula: see text] and 33% [Formula: see text] by volume) are supplied in counterflow arrangement from two separate plenums located at the base of the RDC annulus. Based on experimentation, a total mass flow rate of [Formula: see text] was chosen to achieve stable, single-wave mode RDC operation for all test cases, allowing for one-to-one comparisons. The internal performance of the RDC was characterized by ion probes and pressure measurements (wall static and oscillating) in supply plenums and across different axial locations of the combustor. Particle image velocimetry (PIV) at 100 kHz was utilized to measure axial and circumferential velocity components within a two-dimensional region of interest located downstream of the converging nozzle exit. Results show higher internal performance of the RDC with increasing AR of the convergent nozzle. PIV measurement illustrated that the flow oscillation amplitudes decrease with an increasing AR of the converging nozzle. The exit flow contained significant nonuniformity and unsteadiness even with a converging nozzle of AR 2.0, indicating incomplete choking of the flow at the nozzle throat.

Engineering↗

Wide range magnetic electron spectrograph

An electron spectrogrpah is described that covers electron energies from 400 eV to 200 keV with an energy resolution of 10 percent. This overlaps the range of electrostatic deflection devices at low energy and solid state detectors at high energy. The spectrograph uses magnetic deflection of the electrons to achieve energy separation and images the full range of energies on a single plane. The magnetic circuit uses the fringing field of two axially located magnets to attain the large energy range. Six separate electron beams can be dispersed in the field, each entering the circuit from a different angle. This is a particular advantage when measuring plasma electron three-dimensional velocity distributions. The angular response of the instrument is particularly favorable and the stray magnetic field is sufficiently low to meet spacecraft requirements.

Coplan, M. A.↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Applications

Planar Doppler Velocimetry (PDV) concepts using a pulsed laser are described and the obtainable minimum resolved velocities in large-scale wind tunnels are evaluated. Velocity-field measurements are shown to be possible at ranges of tens of meters and with single pulse resolutions as low as 2 m/s. Velocity measurements in the flow of a low-speed, turbulent jet are reported that demonstrate the ability of PDV to acquire both average velocity fields and their fluctuation amplitudes, using procedures that are compatible with large-scale facility operations. The advantages of PDV over current Laser Doppler Anemometry and Particle Image Velocimetry techniques appear to be significant for applications to large facilities.

McKenzie, Robert L.↗

Doppler-shifted fluorescence imaging of velocity fields in supersonic reacting flows

The application of Doppler-shifted fluorescence imaging of velocity fields in supersonic reacting flows is analyzed. Focussing on fluorescence of the OH molecule in typical H2-air Scramjet flows, the effects of uncharacterized variations in temperature, pressure, and collisional partner composition across the measurement plane are examined. Detailed measurements of the (1,0) band OH lineshape variations in H2-air combustions are used, along with single-pulse and time-averaged measurements of an excimer-pumped dye laser, to predict the performance of a model velocimeter with typical Scramjet flow properties. The analysis demonstrates the need for modification and control of the laser bandshape in order to permit accurate velocity measurements in the presence of multivariant flow properties.

Allen, M. G.↗

Tully-Fisher Distances and Dynamical Mass Constraints for 24 Host Galaxies of Reverberation-Mapped AGNs

We present Tully–Fisher distances for 24 active galactic nucleus (AGN) host galaxies with black hole mass (M(sub BH)) measurements from reverberation mapping, as well as the first calibration of the V-band Tully–Fisher relation. Combining our measurements of H I 21 cm emission with Hubble Space Telescope and ground-based optical and near-infrared images allows multiple distance measurements for 19 galaxies and single measurements for the remaining 5. Separation of the nucleus from its host galaxy via surface brightness decomposition yields galaxy-only luminosities, thus allowing measurements of the distance moduli free of contamination from the AGNs. For 14 AGN hosts, these are the first reported distances independent of redshift, and hence independent of peculiar velocities. For the remaining galaxies, we show good agreement between our distances and those previously reported from surface brightness fluctuations and Cepheids. We also determine the total galaxy mass enclosed within the estimated H I radius, which when compared to the baryonic content allows for constraints on the dark matter masses. We find a typical mass fraction of M(sub DM)/M(sub DYN) = 62%, and find significant correlations between M(sub BH)–M(sub DYN) and M(sub BH)–M(sub DM). Finally, we scale our galaxy radii based on estimated relationships between visible and halo radii and assume a flat rotation curve out to the halo radius to approximate M(sub HALO). Over the range of M(sub BH) and M(sub HALO) in this sample, we find good agreement with observationally constrained relationships between M(sub BH) and M(sub HALO) and with hydrodynamical simulations.

AGN host galaxies↗

Time Resolved Particle Image Velocimetry in Nozzle Flow

Temporally resolved particle image velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows—a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered six nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centred along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space–time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Temporally Resolved Particle Image Velocimetry↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation in a Single Injector Cooling Flow

NASA's Turbulent Heat Flux (THX) task under the Transformational Tools & Technologies project is focused on acquiring benchmark temperature and velocity data in turbulent shear layers for validation of computational fluid dynamics (CFD) codes. Standard CFD turbulence models lack the ability to accurately calculate a number of fundamental flow phenomena, including the turbulent transport of heat. In nearly all production class Reynolds-averaged Navier-Stokes (RANS) CFD codes, a gradient-diffusion approximation is used whereby a constant turbulent Prantdl number, Prt, is used to relate an eddy viscosity calculated for the momentum terms, to the turbulent heat flux terms. The default in most CFD codes is Prt = 0.9, however this is not representative of all flows. As discussed in Yoder et al. (2015) and Reynolds (1974), Prt = 0.7 is felt to be more appropriate for jets. Recent work, as discussed in Yoder (2016a), has explored more complex formulations including variable turbulent Prantdl number models. PARTICLE IMAGE VELOCIMETRY; TEMPERATURE MEASURING INSTRUMENTS; FILM COOLING; HIGH TEMPERATURE GASES; COMPUTATIONAL FLUID DYNAMICS; PREDICTION ANALYSIS TECHNIQUES; TURBULENCE MODELS; RAMAN SPECTRA; VELOCITY; MACH NUMBER; GAS TURBINE ENGINES; NOZZLE FLOW; THERMOCOUPLES; LASER INDUCED FLUORESCENCE; COOLING FLOWS (ASTROPHYSICS); RAMAN SPECTROSCOPY; HEAT FLUX

Wernet, Mark P.↗

Dynamics of filaments during the edge-localized mode crash on NSTX

Edge localized modes (ELMs) are routinely observed in H-mode plasma regimes of the National Spherical Torus Experiment (NSTX). Due to the explosive nature of the instability, only diagnostics with high temporal and spatial resolution could provide a detailed insight into the dynamics associated with the ELMs. Gas-puff imaging at NSTX provides 2D measurements of the magnetic field aligned fluctuations (e.g., ELM filaments) in the scrape-off layer and at the plasma edge with 2.5 μs temporal and 10 mm optical resolution. A novel analysis technique was developed to estimate the frame-by-frame velocities and the spatial parameters of the dominant structures associated with the ELMs. The analysis was applied to single ELM events to characterize the ELM crash dynamics and then extended to a database of 159 ELM events. Statistical analysis was performed in order to find the characterizing dynamics of the ELM crash. The results show that on average, an ELM crash consists of a filament with a circular cross section, which is propelled outward with a characterizing peak radial velocity of ~3.3 km/s. The radial velocity was found to be linearly dependent on the distance of the filament from the separatrix, which has never been seen before. The ELM filament is characterized by propagation in the ion-diamagnetic direction poloidally with a peak velocity of 11.4 km/s. The ELM crash lasts for approximately 100 μs until the radial propulsion settles back to the pre-ELM level. Furthermore, the experimental findings were compared with analytical theory. Two possible mechanisms were identified for explaining the observations: the curvature interchange model and the current–filament interaction model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous mapping of the unsteady flow fields by Particle Displacement Velocimetry (PDV)

Current experimental and computational techniques must be improved in order to advance the prediction capability of the longitudinal vortical flows shed by underwater vehicles. The generation, development, and breakdown mechanisms of the shed vortices at high Reynolds numbers are not fully understood. The ability to measure hull separated vortices associated with vehicle maneuvering does not exist at present. The existing point-by-point measurement techniques can only capture approximately the large 'mean' eddies but fail to meet the dynamics of small vortices during the initial stage of generation. A new technique, which offers a previously unavailable capability to measure the unsteady cross-flow distribution in the plane of the laser light sheet, is called Particle Displacement Velocimetry (PDV). PDV consists of illuminating a thin section of the flowfield with a pulsed laser. The water is seeded with microscopic, neutrally buoyant particles containing imbedded fluorescing dye which responds with intense spontaneous fluorescence with the illuminated section. The seeded particles in the vortical flow structure shed by the underwater vehicle are illuminated by the pulse laser and the corresponding particle traces are recorded in a single photographic frame. Two distinct approaches were utilized for determining the velocity distribution from the particle traces. The first method is based on matching the traces of the same particle and measuring the distance between them. The direction of the flow can be identified by keeping one of the pulses longer than the other. The second method is based on selecting a small window within the image and finding the mean shift of all the particles within that region. The computation of the auto-correlation of the intensity distribution within the selected sample window is used to determine the mean displacement of particles. The direction of the flow is identified by varying the intensity of the laser light between pulses. Considerable computational resources are required to compute the auto-correction of the intensity distribution. Parallel processing will be employed to speed up the data reduction. A few examples of measured unsteady vortical flow structures shed by the underwater vehicles will be presented.

Huang, Thomas T.↗

New AFM Techniques for Investigating Molecular Growth Mechanisms of Protein Crystals

Atomic Force Microscopy (AFM) has emerged as a powerful technique for investigating protein crystal growth. Earlier AFM studies were among the first to demonstrate that these crystals grew by dislocation and 2D nucleation growth mechanisms [1]. These investigations were restricted to the micron range where only surface features, such as dislocation hillocks and 2D islands are visible. Most AFM instruments can scan at higher resolutions and have the potential to resolve individual protein molecules at nanometer ranges. Such scans are essential for determining the molecular packing arrangements on crystal faces and for probing the growth process at the molecular level. However, at this resolution the AFM tip influences the image produced, with the resulting image being a convolution of the tip shape and the surface morphology [2]. In most studies this problem is resolved by deconvoluting the image to obtain the true surface morphology. Although deconvolution routines work reasonably well for simple one- dimensional shapes, for complex surfaces this approach does not produce accurate results. In this study we devised a new approach which takes advantage of the precise molecular order of crystal surfaces, combined with the knowledge of individual molecular shapes from the crystallographic data of the protein and the AFM tip shape. This information is used to construct expected theoretical AFM images by convoluting the tip shape with the constructed crystal surface shape for a given surface packing arrangement. By comparing the images from actual AFM scans with the constructed ones for different possible surface packing arrangements, the correct packing arrangement can be conclusively determined. This approach was used in this study to determine the correct one from two possible packing arrangements on (I 10) faces of tetragonal lysozyme crystals. Another novel AFM technique was also devised to measure the dimension of individual growth units of the crystal faces. Measuring these units was not attempted before and most studies have assumed that the growth unit consisted of individual protein molecules. The linescan mode of AFM instruments allows the crystal surface to be scanned along a single line. By scanning across a growth step an image showing the motion of the step is obtained. Normally such an image shows a straight line for continuous and constant step velocity. In this study by increasing the scan rate and by decreasing the step velocity (by decreasing the supersaturation), we were able to capture images of individual growth events, shown by jump discontinuities in the step line. By suitable integration of the image the growth unit dimension in the scanned direction can be obtained. Since multiple units can be involved in the growth process it is necessary to collect a statistically relevant sample before drawing conclusions about the growth mechanism. This technique was successfully employed to obtain the dimensions of growth units for the (110) face, showing that they consisted of various aggregates corresponding to the 43 helices in the crystal structure.

Li, Huayu↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

Dynamics of filaments during the edge-localized mode crash on NSTX

Edge localized modes (ELMs) are routinely observed in H-mode plasma regimes of the National Spherical Torus Experiment (NSTX). Due to the explosive nature of the instability, only diagnostics with high temporal and spatial resolution could provide a detailed insight into the dynamics associated with the ELMs. Gas-puff imaging (GPI) at NSTX provides 2D measurements of the magnetic field aligned fluctuations (e.g. ELM filaments) in the scrape-off layer and the at the plasma edge with 2.5 us temporal and 10 mm optical resolution.A novel analysis technique was developed to estimate the frame-by-frame velocities and the spatial parameters of the dominant structures associated with the ELMs. The analysis was applied to single ELM events to characterize the ELM crash dynamics, and then extended to a database of 169 ELM events.Statistical analysis was performed in order to find the characterizing dynamics of the ELM crash. The results show that on average an ELM crash consists of a filament with a circular cross-section which is propelled outwards with a characterizing peak radial velocity of ~3.3 km/s. The radial velocity was found to be linearly dependent on the distance of the filament from the separatrix, which has never been seen before. The ELM filament is characterized by propagation in the ion-diamagnetic direction poloidally with a peak velocity of 11.4 km/s. The ELM crash lasts for approximately 100us until the radial propulsion settles back to the pre-ELM level. The experimental findings were compared with analytical theory. Two possible mechanisms were identified for explaining the observations: the curvature interchange model and the current-filament interaction model.

correlation↗

Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

Roth, Don J.↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗