Search NASA⌕ Search

SEARCH · Search NASA

Results for “size measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The in-situ cometary particulate size distribution measured for one comet: P/Halley

The close approach of Giotto to comet Halley during its 1986 apparition offered an opportunity to study the particulate mass distribution to masses of up to one gram. Data acquired by the front end channels of the highly sensitive mass spectrometer PIA and the dust shield detector system, DIDSY, provide definition to the detected distribution as close as 1000 km to the nucleus. Dynamic motion of the particulates after emission leads to a spatial differentiation affecting the size distribution in several forms: (1) ejecta velocity dispersion; (2) radiation pressure; (3) varying heliocentric distance; and (4) anisotropic nucleus emission. Transformation of the in-situ distribution from PIA and DIDSY weighted heavily by the near-nucleus fluxes leads to a presumed nucleus distribution. The data lead to a puzzling distribution at large masses, not readily explained in an otherwise monotonous power law distribution. Although temporal changes in nucleus activity could and do modify the in-situ size distribution, such an explanation is not wholly possible, because the same form is observed at differing locations in the coma where the time of flight from the nucleus greatly varies. Thus neither a general change in comet activity nor spatial variations lead to a satisfactory explanation.

Mcdonnell, J. A. M.↗

Agreement between experimental and theoretical effects of nitrogen gas flowrate on liquid jet atomization

Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a sampling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less effected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.

Ingebo, Robert D.↗

Agreement between experimental and theoretical effects of nitrogen gas flowrate on liquid jet atomization

Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop-size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a smapling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less affected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.

Ingebo, Robert D.↗

Photographic method measures particle size and velocity in fluid stream

Method employing a nonframing motion picture camera, a continuous front light source, and a strobe light determines the size and velocity of small particles in nonturbulent fluid streams. This method is used in the study of the motion of solid and liquid particles in research and industrial fluid flow systems.

Dickerson, R. A.↗

Space Shuttle exhausted aluminum oxide - A measured particle size distribution

Aluminum oxide (A2O3) particles were collected from the Space Shuttle exhaust plume immediately following the launch of STS-34 on October 18, 1989. A2O3 samples were obtained at 2.4, 3.0, 3.2, and 7.4 km in altitude. The samples were analyzed using SEM to develope particle size distributions. There were no indications that the particle size distribution changed as a function of altitude. The particle number concentrations per cubic meter of air sampled for the four collections was found to fit an exponential expression.

Cofer, W. R., III↗

Measuring Aerosol Size Distributions from the NASA DC-8 in SOLVE II

The University of Denver Focused Cavity Aerosol Spectrometer (FCAS 11) and Nucleation-Mode Aerosol Size Spectrometer (N-MASS) were successfully integrated and flown aboard NASA s DC-8 for the second SAGE I11 Ozone Loss and Validation Experiment (SOLVE 11). Both instruments performed well during SOLVE, with virtually complete data coverage for all mission and test flights. The few exceptions to this were the occasional simultaneous zero-check for the instruments, and some data loss for channel 4 of the N-MASS. The only consequence of the latter is reduced resolution in the 15 to 60 nm range for the affected size distributions.

Reeves, Michael↗

Another Look at Erupting Minifilaments at the Base of Solar X-Ray Polar Coronal “Standard” and “Blowout” Jets

We examine 21 solar polar coronal jets that we identify in soft X-ray images obtained from the Hinode/X-ray telescope (XRT). We identify 11 of these jets as blowout jets and four as standard jets (with six uncertain), based on their X-ray-spire widths being respectively wide or narrow (compared to the jet’s base) in the XRT images. From corresponding Extreme Ultraviolet (EUV) images from the Solar Dynamics Observatory’s (SDO) Atmospheric Imaging Assembly (AIA), essentially all (at least 20 of 21) of the jets are made by minifilament eruptions,consistent with other recent studies. Here, we examine the detailed nature of the erupting minifilaments (EMFs) in the jet bases. Wide-spire (“blowout”) jets often have ejective EMFs, but sometimes they instead have an EMF that is mostly confined to the jet’s base rather than ejected. We also demonstrate that narrow-spire (“standard”) jets can have either a confined EMF, or a partially confined EMF where some of the cool minifilament leaks into the jet’s spire. Regarding EMF visibility: we find that in some cases the minifilament is apparent in as few as one of the four EUV channels we examined, being essentially invisible in the other channels; thus it is necessary to examine images from multiple EUV channels before concluding that a jet does not have an EMF at its base. The size of the EMFs, measured projected against the sky and early in their eruption, is 14′′ ± 7′′, which is within a factor of two of other measured sizes of coronal-jet EMFs. A full report on these results will be published in the Astrophysical Journal. This work was supported by NASA's HGI, HSR, and HSOC programs, and by the NASA/MSFC Hinode Project.

Alphonse C Sterling↗

Another Look at Erupting Minifilaments at the Base of Solar X-Ray Polar Coronal “Standard” and “Blowout” Jets

We examine 21 solar polar coronal jets that we identify in soft X-ray images obtained fromthe Hinode/X-ray telescope (XRT). We identify 11 of these jets as blowout jets and four asstandard jets (with six uncertain), based on their X-ray-spire widths being respectively wide or narrow (compared to the jet’s base) in the XRT images. From corresponding Extreme Ultraviolet (EUV) images from the Solar Dynamics Observatory’s (SDO) Atmospheric Imaging Assembly (AIA), essentially all (at least 20 of 21) of the jets are made by minifilament eruptions, consistent with other recent studies. Here, we examine the detailed nature of the erupting minifilaments (EMFs) in the jet bases. Wide-spire (“blowout”) jets often have ejective EMFs, but sometimes they instead have an EMF that is mostly confined to the jet’s base rather than ejected. We also demonstrate that narrow-spire (“standard”) jets can have either a confined EMF, or a partially confined EMF where some of the cool minifilament leaks into the jet’s spire. Regarding EMF visibility: we find that in some cases the minifilament is apparent in as few as one of the four EUV channels we examined, being essentially invisible in the other channels; thus it is necessary to examine images from multiple EUV channels before concluding that a jet does not have an EMF at its base. The size of the EMFs, measured projected against the sky and early in their eruption, is 14′′ ± 7′′, which is within a factor of two of other measured sizes of coronal-jet EMFs. A full report on these results are available in Sterling et al. (2022, ApJ, 927, 127).This work was supported by NASA’s HGI and HSR programs, and by the MSFC HinodeProject.

Alphonse C Sterling↗

Spray drop size and velocity measurements using the Phase/Doppler Particle Analyzer

Detailed measurements of the drop size and velocity distributions were obtained for a swirl chamber pressure atomizer. These data were obtained with the Phase/Doppler Particle Analyzer manufactured by Aerometrics, Inc. Direct measurements of the size distributions revealed the evolving characteristics of the spray. Size velocity correlations were used to evaluate the effect of velocity relaxation on the size distributions. The simultaneous measurement of drop size and velocity was of major importance in accurately describing the changes in the local drop size distributions and mass flux.

Bachalo, W. D.↗

Probing the Magnetic Causes of CMEs: Free Magnetic Energy More Important Than Either Size Or Twist

To probe the magnetic causes of CMEs, we have examined three types of magnetic measures: size, twist and total nonpotentiality (or total free magnetic energy) of an active region. Total nonpotentiality is roughly the product of size times twist. For predominately bipolar active regions, we have found that total nonpotentiality measures have the strongest correlation with future CME productivity (approx. 75% prediction success rate), while size and twist measures each have a weaker correlation with future CME productivity (approx. 65% prediction success rate) (Falconer, Moore, & Gary, ApJ, 644, 2006). For multipolar active regions, we find that the CME-prediction success rates for total nonpotentiality and size are about the same as for bipolar active regions. We also find that the size measure correlation with CME productivity is nearly all due to the contribution of size to total nonpotentiality. We have a total nonpotentiality measure that can be obtained from a line-of-sight magnetogram of the active region and that is as strongly correlated with CME productivity as are any of our total-nonpotentiality measures from deprojected vector magnetograms. We plan to further expand our sample by using MDI magnetograms of each active region in our sample to determine its total nonpotentiality and size on each day that the active region was within 30 deg. of disk center. The resulting increase in sample size will improve our statistics and allow us to investigate whether the nonpotentiality threshold for CME production is nearly the same or significantly different for multipolar regions than for bipolar regions. In addition, we will investigate the time rates of change of size and total nonpotentiality as additional causes of CME productivity.

Falconer, D. A.↗

Highly Resolved Aerosol Measurements from High Altitude Platforms

The University of Denver agreed to develop and fabricate two instruments for the characterization of submicron aerosol. The instruments were to be light weight for use on remotely-piloted aircraft or balloons. The instruments were to provide accurate size measurements of size distributions in the size range from 0.07 to 2 micrometers in diameter and concentration measurements in the size range approximately 0.01 to 2 micrometers in diameter. The instruments constructed under this cooperative agreement respond quite nearly as expected and meet the objective of being light and compact. One has been used for ground based and low altitude studies and the other will be deployed in high altitude studies this winter.

Wilson, James Charles↗

Evidence for Natural Variability in Marine Stratocumulus Cloud Properties Due to Cloud-Aerosol

In this study, aircraft observations from the Interdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter are used to characterize the variability in drizzle, cloud, and aerosol properties associated with cloud rifts and the surrounding solid clouds observed off the coast of California. A flight made on 16 July 1999 provided measurements directly across an interface between solid and rift cloud conditions. Aircraft instrumentation allowed for measurements of aerosol, cloud droplet, and drizzle spectra. CCN concentrations were measured in addition to standard thermodynamic variables and the winds. A Forward Scatter Spectrometer Probe (FSSP) measured size distribution of cloud-sized droplets. A Cloud Imaging Probe (CIP) was used to measure distributions of drizzle-sized droplets. Aerosol distributions were obtained from a Cloud Aerosol Scatterprobe (CAS). The CAS probe measured aerosols, cloud droplets and drizzle-sized drops; for this study. The CAS probe was used to measure aerosols in the size range of 0.5 micron - 1 micron. Smaller aerosols were characterized using an Ultrafine Condensation Particle Counter (CPC) sensor. The CPC was used to measure particles with diameters greater than 0.003 micron. By subtracting different count concentrations measured with the CPC, this probe was capable of identifying ultrafine particles those falling in the size range of 3 nanometers - 7 nanometers that are believed to be associated with new particle production.

Albrecht, Bruce↗

Development of a simplified optical technique for the simultaneous measurement of particle size distribution and velocity

Existing techniques were surveyed, an experimental procedure was developed, a laboratory test model was fabricated, limited data were recovered for proof of principle, and the relationship between particle size distribution and amplitude measurements was illustrated in an effort to develop a low cost, simplified optical technique for measuring particle size distributions and velocities in fluidized bed combustors and gasifiers. A He-Ne laser illuminated Rochi Rulings (range 10 to 500 lines per inch). Various samples of known particle size distributions were passed through the fringe pattern produced by the rulings. A photomultiplier tube converted light from the fringe volume to an electrical signal which was recorded using an oscilloscope and camera. The signal amplitudes were correlated against the known particle size distributions. The correlation holds true for various samples.

Smith, J. L.↗

Radiation Pressure Measurements on Micron Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

Abbas, M. M.↗