Verification and Validation of Optimization of Replacement Portal Monitoring Replay Tools

The Los Alamos National Laboratory and the Johns Hopkins Applied Physics Laboratory (APL) are both developing optimization software to fulfill the objective of Phase III of the Replacement Portal Monitoring (RPM) Program for the Department of Homeland Security. The objective of the Phase III of the RPM Program is to conduct an evaluation of three RPM systems designed to enhance mission effectiveness, gain operational efficiencies, and to address emerging mission needs against the Countering Weapons of Mass Destruction (CWMD ) nuclear threat basis and special nuclear material (SNM) used in performance testing. As such this task involves the use of global optimization algorithms.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling and Simulation Tool to Improve Urban Search Planning (NA22 Final Report)

The venture project Tool to Improve Urban Search Planning (LL14-V-Urban Search Planning ToolPD3RS) supported two major types of effort: 1) development of a software prototype search planning tool, with the goal of transitioning the tool to operational users for evaluation and possible adoption; 2) enabling research to better understand the radiation characteristics of an urban environment, with implications for deployment of radiation detection systems in that environment. The first effort has resulted in prototype software, Optimization Planning Tool for Urban Search (OPTUS), that has been distributed to a limited set of potential users, including users within the NNSA emergency response community. The second effort supported various research topics including high fidelity radiation transport modeling in urban environments, measurement campaigns for model validation, development of vehicle-based high purity germanium (HPGe) detector systems and supporting data analysis, and computational capabilities for archiving and managing large data sets. While some of these related efforts have informed the models and software design of the OPTUS tool, in large part they pursued more basic research, some of which has evolved into separate DNN R&D projects. Project performers included Oak Ridge National Laboratory (ORNL), Lawrence Berkeley National Laboratory (LBNL) and the Remote Sensing Laboratory (RSL), in addition to Lawrence Livermore Laboratory (LLNL), the project lead. The project also supported university research, including several internships at the laboratories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SmartApps: Middle-ware for Adaptive Applications on Reconfigurable Platforms

There are several reasons why the performance of current distributed and heterogeneous systems is often disappointing. For example, the characteristics of the application may be input sensitive and evolve during execution causing dramatic changes in memory reference patterns, resource requirements, or degree of concurrency between different phases of the computation. Or, the system may change dynamically with nodes failing or appearing, some network links severed and other links established with different latencies and bandwidths. Another important reason for poor performance is the fairly compartmentalized approach to optimization: applications, compilers, operating systems and hardware configurations are designed and optimized in isolation and without the knowledge of instance specific information and needs of a running application. There is too little information flow across these boundaries and no global optimization is even attempted. For example, most operating systems services like paging, virtual-to-physical page mapping, I/O, or data layout in disks, provide little or no application customization. Similarly, the off-the-shelf hardware used by most commercial systems is optimized to give best average-case performance. To address this problem, we have proposed application-centric computing, or Smart Applications (SAS). In the SAS executable, the compiler embeds most run-time system services, and a performance-optimizing feedback loop that monitors the application's performance and adaptively reconfigures the application and the OS/system platform. At run-time, after incorporating the code's input and determining the system's resources and state, the SAS performs an *instance* specific optimization, which is more tractable than a global generic optimization between application, OS and system. The overriding philosophy of SAS is ``measure, compare, and adapt if beneficial.'' That is, the application will continually monitor its performance and the available resources to determine if, and by how much, performance could be improved if the application was restructured. Then, if the potential performance benefit outweighs the projected overhead costs, the application will restructure itself and the underlying system accordingly. The SAS framework includes performance monitoring and modeling components and mechanisms for performing the actual restructuring at various levels including: (i) algorithmic adaptation, (ii) run-time software optimization (e.g., input sensitivity analysis, etc.), (iii) tuning reconfigurable OS services (scheduling policy, page size, etc), and (iv) system configuration (e.g., selecting which, and how many, computational resources to use). SmartApps is being developed in the STAPL infrastructure. STAPL (the Standard Template Adaptive Parallel Library) is a framework for developing highly-optimizable, adaptable, and portable parallel and distributed applications. It consists of a relatively new and still evolving collection of generic parallel algorithms and distributed containers and a run-time system (RTS) through which the application and compiler interact with the OS and hardware.

97 MATHEMATICS AND COMPUTING↗

Validating automated resonance evaluation with synthetic data

The integrity and precision of nuclear data are crucial for a broad spectrum of applications, from national security and nuclear reactor design to medical diagnostics, where the associated uncertainties can significantly impact outcomes. A substantial portion of uncertainty in nuclear data originates from the subjective biases in the evaluation process, a crucial phase in the nuclear data production pipeline. Recent advancements indicate that automation of certain routines can mitigate these biases, thereby standardizing the evaluation process and enhancing reproducibility. This research aims to provide a methodology, framework, and metrics for the validation of automated nuclear data evaluation software leveraging high-quality synthetic data that closely mimic real experimental observables. An introduced error metric provides a scale and intuitive measure of the evaluation quality by quantifying the estimate’s accuracy and performance across the specified energy range. Synthetic data provides access to experimental observables and underlying resonance parameters, enabling comparison of different evaluations. The methodology is demonstrated using Ta-181 isotope data in the resolved resonance region. The Automated Resonance Identification Subroutine (ARIS), which operates without prior resonance information, was used to test and showcase the framework’s capabilities utilizing the proposed error metrics. The results demonstrate the effectiveness of the proposed approach and framework for optimizing software parameters and testing hypotheses through “what-if” controlled experiments, such as modifying assumptions about experimental conditions or average resonance parameters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-G-JeP1-10: Feasibility of CyberKnife Tracking Using the Previously-Implanted Permanent Brachytherapy Seed Cloud

Purpose: Robotic radiosurgery is a salvage treatment option for patients with recurrent prostate cancer. We explored the feasibility of tracking the bolus of permanent prostate implants (PPI) using image recognition software optimized to track spinal anatomy. Methods: Forty-five inert iodine seeds were implanted into a gelatin-based prostate phantom. Four superficial gold seeds were inserted to provide ground-truth alignment. A CT scan of the phantom (120 kVp, 1 mm slice thickness) was acquired and a single-energy iterative metal artifact reduction (MAR) algorithm was used to enhance the quality of the DRR used for tracking. CyberKnife treatment plans were generated from the MAR CT and regular CT (no-MAR) using spine tracking. The spine-tracking grid was centered on the bolus of seeds and resized to encompass the full seed cloud. A third plan was created from the regular CT scan, using fiducial tracking based on the 4 superficial gold seeds with identical align-center coordinates. The phantom was initially aligned using the fiducial-tracking plan. Then the MAR and no-MAR spine-tracking plans were loaded without moving the phantom. Differences in couch correction parameters were recorded in the case of perfect alignment and after the application of known rotations and translations (roll/pitch of 2 degrees; translations XYZ of 2 cm). Results: The spine tracking software was able to lock on to the bolus of seeds and provide couch corrections both in the MAR and no-MAR plans. In all cases, differences in the couch correction parameters from fiducial alignment were <0.5 mm in translations and <1 degree in rotations. Conclusion: We were able to successfully track the bolus of seeds with the spine-tracking grid in phantom experiments. For clinical applications, further investigation and developments to adapt the spine-tracking algorithm to optimize for PPI seed cloud tracking is needed to provide reliable tracking in patients. One of the authors (MD) has received research support and speaker honoraria from Accuray.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 69: Computational Study of DVH-guided Cancer Treatment Planning Optimization Methods

Purpose: To compare methods to incorporate the Dose Volume Histogram (DVH) curves into the treatment planning optimization. Method: The performance of three methods, namely, the conventional Mixed Integer Programming (MIP) model, a convex moment-based constrained optimization approach, and an unconstrained convex moment-based penalty approach, is compared using anonymized data of a prostate cancer patient. Three plans we generated using the corresponding optimization models. Four Organs at Risk (OARs) and one Tumor were involved in the treatment planning. The OARs and Tumor were discretized into total of 50,221 voxels. The number of beamlets was 943. We used commercially available optimization software Gurobi and Matlab to solve the models. Plan comparison was done by recording the model runtime followed by visual inspection of the resulting dose volume histograms. Conclusion: We demonstrate the effectiveness of the moment-based approaches to replicate the set of prescribed DVH curves. The unconstrained convex moment-based penalty approach is concluded to have the greatest potential to reduce the computational effort and holds a promise of substantial computational speed up.

60 APPLIED LIFE SCIENCES↗

Nuclear waste calorimeter for very large drums with 385 litres sample volume

Calorimetry is a very precise and well adapted tool for the classification of drums containing nuclear waste material depending on their level of activities (low, medium, high). A new calorimeter has been developed by SETARAM Instrumentation and the CEA Valduc in France. This new calorimeter is designed for drums having a volume bigger than 100 liters. It guarantees high operator safety by optimizing drum handling and air circulation for cooling, and optimized software for direct measurement of the quantity of nuclear material. The LVC1380 calorimeter makes it possible to work over the range 10 to 3000 mW, which corresponds to approximately 0.03 to 10 g of tritium or 3 to 955 g of {sup 241}Pu in a volume up to 385 liters. This calorimeter is based on the heat flow measurement using Peltier elements which surround the drum in the 3 dimensions and therefore measure all the heat coming from the radioactive stuff whatever its position inside the drum. Calorimeter's insulating layers constitute a thermal barrier designed to filter disturbances until they represent less than 0.001 Celsius degrees and to eliminate long term disturbances associated, for example, with laboratory temperature variations between day and night. A calibration device based on Joule effect has also been designed. Measurement time has been optimized but remains long compared with other methods of measurement such as gamma spectrometry but its main asset is to have a good accuracy for low level activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Grain Boundary Structures with LAMMPS Using Evolutionary Algorithms

Grain boundary structure optimization is an important part of materials modeling. Current methods for grain boundary structure optimization involve inefficient, time-consuming processes that do not fully explore the interface parameter space. Evolutionary algorithms have recently been demonstrated to be effective at determining both stable and metastable grain boundary interface structures. In this work, we demonstrate the use of GBOpt, a grain boundary structure optimization software designed to use the Large-scale Atomic/Molecular Massively Parallel Simulation (LAMMPS) software to efficiently determine grain boundary structures. We demonstrate that a only a few manipulations, namely atom insertion, atom removal, and relative grain displacement, are sufficient to explore much of the grain boundary structure parameter space. The efficacy of this approach is demonstrated on an FCC Ni system, and a BCC Fe system. The computational cost is compared against the gamma-surface sampling approach to demonstrate performance improvement.

Evolutionary algorithms↗

Thermostatic Radiator Valve Evaluation and Demonstration

A large stock of multifamily buildings in the Northeast and Midwest uses hot water or steam for space heating. Typically, residents do not pay for heat directly (i.e., heating fuel serves a central plant and use is not submetered). Losses from these systems are typically high, and a significant number of apartments are overheated much of the time. This is often evidenced by open windows on winter days. Controls and distribution are often faulty, and improving them can be more cost effective than replacing boilers. Thermostatic radiator valves (TRVs), which have been in use for many decades, are one potential strategy to combat this problem. They are commonly used in Europe and in other markets such as commercial buildings, but have not been widely accepted by the residential retrofit market in the northeastern United States. Anecdotal evidence suggests that heating systems engineers and contractors have a variety of opinions about their effectiveness, illustrating a lack of consensus on this potentially important energy efficiency measure. A review of the limited available literature revealed that, in one study, heating fuel savings as high as 15% was achieved through TRV retrofits. In this project, the U.S. Department of Energy Building America team, Advanced Residential Integrated Energy Solutions, sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt (Building Energy Optimization software). Radiator and apartment space temperature data were collected and analyzed for two similar apartment units in a building that underwent a one-pipe steam TRV retrofit. Space temperature comparisons were made across the pre- and post-TRV installation heating periods and between rooms equipped with old or new TRVs in an attempt to show the comparative effectiveness of each vintage of TRV. Analyses of the heating fuel utility bills before and after the building-wide TRV installation were conducted to quantify potential savings. The results of the field experiment and utility bill analysis did not show energy savings at either the unit or the building-wide level. The results provided inconclusive answers to the original study questions but provided valuable insight into common steam system imbalance and resident behavior issues that are critical to address in conjunction with TRV retrofits. Specific issues identified included steam distribution imbalance, possible TRV sensor location issues, a persistent window-opening habit, and a failure to optimize the boiler control set points as part of the TRV retrofit. The lack of heating fuel savings underscored the need to include whole steam system commissioning alongside or as a prerequisite to TRVs. Failed air vents and uneven steam main venting are critical to address either in conjunction with or before a TRV installation. Monitoring existing space temperatures before a retrofit strategy is chosen would allow the consultant and building owner to better assess the potential benefits of a whole-building TRV retrofit, selective installation of TRVs in some units, or simply balancing the steam distribution venting. Further gaps in the understanding of underlying processes that allow TRVs to function effectively were also identified and are presented as opportunities for future research.

Array↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Turbomole

Turbomole is a highly optimized software package for large‐scale quantum chemical simulations of molecules, clusters, and periodic solids. Turbomole uses G aussian basis sets and specializes on predictive electronic structure methods with excellent cost to performance characteristics, such as (time‐dependent) density functional theory ( TDDFT ), second‐order M øller– P lesset theory, and explicitly correlated coupled cluster ( CC ) methods. These methods are combined with ultraefficient and numerically stable algorithms such as integral‐direct and Laplace transform methods, resolution‐of‐the‐identity, pair natural orbitals, fast multipole, and low‐order scaling techniques. Apart from energies and structures, a variety of optical, electric, and magnetic properties are accessible from analytical energy derivatives for electronic ground and excited states. Recent additions include post‐ K ohn– S ham calculations within the random phase approximation, periodic calculations, spin–orbit couplings, explicitly correlated CC singles doubles and perturbative triples methods, CC singles doubles excitation energies, and nonadiabatic molecular dynamics simulations using TDDFT . A dedicated graphical user interface and a user support network are also available. This article is categorized under: Software > Quantum Chemistry

Furche, Filipp↗

Impact of Detector Simulation in Particle Physics Collider Experiments - Highlights

Detector simulation has become fundamental to the success of modern high-energy physics (HEP) experiments. For example, the Geant4-based simulation applications developed by the ATLAS and CMS experiments played a major role for them to produce physics measurements of unprecedented quality and precision with faster turnaround, from data taking to journal submission, than any previous hadron collider experiment. The material presented here contains highlights of a recent review on the impact of detector simulation in particle physics collider experiments published in Ref. [1]. It includes examples of applications to detector design and optimization, software development and testing of computing infrastructure, and modeling of physics objects and their kinematics. The cost and economic impact of simulation in the CMS experiment is also presented. A discussion on future detector simulation needs, challenges and potential solutions to address them is included at the end.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Unit Testing Framework for Scientific Legacy Code

Large-scale scientific applications play important roles in supporting research. However, it is often very expensive and time-consuming to make changes to, maintain and evolve the scientific code due to its complexity and poor programming skills of researchers. Therefore, in order to visualize scientific code architecture to optimize software design, understand undocumented source code, and analyze software flow and functionality, we first introduce a unit testing framework (UTF). Then, because such infrastructure's performance is very crucial in practical use since the scientific legacy applications simulate instances in a long period of time, we improve the UTF by applying Message Passing based Parallelization and parallel I/O operations. Furthermore, due to the scientific code has enormous state data and the I/O capacity on the server is limited, we apply in situ data analysis method to encounter fewer resource limitations, and adopt signal processing to greatly reduce data transfer. Last, we demonstrated the correctness and high-efficiency of our framework for legacy Earth model on Titan supercomputer.

97 MATHEMATICS AND COMPUTING↗

Accelerating Random Forest Classification on GPU and FPGA

Random Forests (RFs) are a commonly used machine learning method for classification and regression tasks spanning a variety of application domains, including bioinformatics, business analytics, and software optimization. While prior work has focused primarily on improving performance of the training of RFs, many applications, such as malware identification, cancer prediction, and banking fraud detection, require fast RF classification. In this work, we accelerate RF classification on GPU and FPGA. In order to provide efficient support for large datasets, we propose a hierarchical memory layout suitable to the GPU/FPGA memory hierarchy. We design three RF classification code variants based on that layout, and we investigate GPU- and FPGA-specific considerations for these kernels. Our experimental evaluation, performed on an Nvidia Xp GPU and on a Xilinx Alveo U250 FPGA accelerator card using publicly available datasets on the scale of millions of samples and tens of features, covers various aspects. First, we evaluate the performance benefits of our hierarchical data structure over the standard compressed sparse row (CSR) format. Second, we compare our GPU implementation with cuML, a machine learning library targeting Nvidia GPUs. Third, we explore the performance/accuracy tradeoff resulting from the use of different tree depths in the RF. Finally, we perform a comparative performance analysis of our GPU and FPGA implementations. Our evaluation shows that for high accuracy targets, our GPU implementation yields 5-9x speedup over CSR, and up to a 2x speedup over cuML.

FPGA, Xilinx FPGA, GPU, Random Forest classificati↗

ARQUIN: Architectures for Multinode Superconducting Quantum Computers

Many proposals to scale quantum technology rely on modular or distributed designs wherein individual quantum processors, called nodes, are linked together to form one large multinode quantum computer (MNQC). One scalable method to construct an MNQC is using superconducting quantum systems with optical interconnects. However, internode gates in these systems may be two to three orders of magnitude noisier and slower than local operations. Surmounting the limitations of internode gates will require improvements in entanglement generation, use of entanglement distillation, and optimized software and compilers. Still, it remains unclear what performance is possible with current hardware and what performance algorithms require. In this article, we employ a systems analysis approach to quantify overall MNQC performance in terms of hardware models of internode links, entanglement distillation, and local architecture. We show how to navigate tradeoffs in entanglement generation and distillation in the context of algorithm performance, lay out how compilers and software should balance between local and internode gates, and discuss when noisy quantum internode links have an advantage over purely classical links. Here, we find that a factor of 10–100× better link performance is required and introduce a research roadmap for the co-design of hardware and software towards the realization of early MNQCs. While we focus on superconducting devices with optical interconnects, our approach is general across MNQC implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗