Search NASA⌕ Search

SEARCH · Search NASA

Results for “software triggering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Operation of the trigger system for the ICARUS detector at Fermilab

The ICARUS liquid argon TPC detector is taking data on the Booster (BNB) and Main Injector (NuMI) Neutrino beam lines at Fermilab with a trigger system based on the scintillation light produced by charged particles in coincidence with the proton beam extraction from the accelerators. The architecture and the deployment of the trigger system in the first two runs for physics are presented, as well as the triggered event rates. The event recognition efficiency has been evaluated as a function of the deposited energy and the position of cosmic muons stopping inside the detector.

Neutrino detectors↗

CoreMS AutoQC Uploader

The invention is a self contained software utility that is deployed on the computer controlling a mass spectrometer. The purpose of the software is to monitor a given directory for files matching a user specified criteria and automatically upload matching files to a remote server as well as trigger a request that the data be processed by the cloud based CoreMS software

Rabus, Jordan [Pacific Northwest National Laborato↗

Oil/water/rock wettability: Influencing factors and implications for low salinity water flooding in carbonate reservoirs

Wettability of the oil/brine/rock system is an essential petro-physical parameter which governs subsurface multiphase flow behaviour and the distribution of fluids, thus directly affecting oil recovery. Recent studies [1–3] show that manipulation of injected brine composition can enhance oil recovery by shifting wettability from oil-wet to water-wet. However, what factor(s) control system wettability has not been completely elucidated due to incomplete understanding of the geochemical system. To isolate and identify the key factors at play we used in this paper SO 4 2 —free solutions to examine the effect of salinity (formation brine/FB, 10 times diluted formation brine/10 dFB, and 100 times diluted formation brine/100 dFB) on the contact angle of oil droplets at the surface of calcite. We then compared contact angle results with predictions of surface complexation by low salinity water using PHREEQC software. We demonstrate that the conventional dilution approach likely triggers an oil-wet system at low pH, which may explain why the low salinity water EOR-effect is not always observed by injecting low salinity water in carbonated reservoirs. pH plays a fundamental role in the surface chemistry of oil/brine interfaces, and wettability. Our contact angle results show that formation brine triggered a strong water-wet system (35°) at pH 2.55, yet 100 times diluted formation brine led to a strongly oil-wet system (contact angle = 175°) at pH 5.68. Surface complexation modelling correctly predicted the wettability trend with salinity; the bond product sum ([>CaOH 2 + ][–COO - ] + [>CO 3 - ][–NH + ] + [>CO 3 - ][–COOCa + ]) increased with decreasing salinity. Finally, at pH < 6 dilution likely makes the calcite surface oil-wet, particularly for crude oils with high base number. Yet, dilution probably causes water wetness at pH > 7 for crude oils with high acid number.

02 PETROLEUM↗

Streaming readout for next generation electron scattering experiments

Current and future experiments at the high-intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard ‘triggered’ data acquisition systems with a new, simplified and outperforming scheme. ‘Streaming readout’ (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper, we report results of the on-beam validation of the Jefferson Lab SRO framework. In this work, we exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.

47 OTHER INSTRUMENTATION↗

Performance of the CMS muon trigger system in proton-proton collisions at $\sqrt{s} =$ 13 TeV

The muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 $\times$ 10$^{34}$cm$^{-2}$s$^{-1}$ while delivering proton-proton collisions at $\sqrt{s} =$ 13 TeV. The challenge for the trigger system of the CMS experiment is to reduce the registered event rate from about 40 MHz to about 1 kHz. Significant improvements important for the success of the CMS physics program have been made to the muon trigger system via improved muon reconstruction and identification algorithms since the end of Run 1 and throughout the Run 2 data-taking period. The new algorithms maintain the acceptance of the muon triggers at the same or even lower rate throughout the data-taking period despite the increasing number of additional proton-proton interactions in each LHC bunch crossing. In this paper, the algorithms used in 2015 and 2016 and their improvements throughout 2017 and 2018 are described. Measurements of the CMS muon trigger performance for this data-taking period are presented, including efficiencies, transverse momentum resolution, trigger rates, and the purity of the selected muon sample. This paper focuses on the single- and double-muon triggers with the lowest sustainable transverse momentum thresholds used by CMS. The efficiency is measured in a transverse momentum range from 8 to several hundred GeV.

Trigger detectors↗

The CARIBU EBIS control and synchronization system

The Californium Rare Isotope Breeder Upgrade (CARIBU) Electron Beam Ion Source (EBIS) charge breeder has been built and tested. The bases of the CARIBU EBIS electrical system are four voltage platforms on which both DC and pulsed high voltage outputs are controlled. The high voltage output pulses are created with either a combination of a function generator and a high voltage amplifier, or two high voltage DC power supplies and a high voltage solid state switch. Proper synchronization of the pulsed voltages, fundamental to optimizing the charge breeding performance, is achieved with triggering from a digital delay pulse generator. The control system is based on National Instruments realtime controllers and LabVIEW software implementing Functional Global Variables (FGV) to store and access instrument parameters. Fiber optic converters enable network communication and triggering across the platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The electronics, trigger and data acquisition system for the liquid argon time projection chamber of the DarkSide-50 search for dark matter

The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.

Agnes, P.↗

Design and performance of a respiratory amplitude gating device for PET/CT imaging

Purpose: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. Methods: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order to monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range reached a user-set interval. This device was tested using a volunteer and a phantom study. Results: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. Conclusions: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Self Tuning

The AST software includes numeric methods to 1) adjust STA/LTA signal detector trigger level (TL) values and 2) filter detections for a network of sensors. AST adapts TL values to the current state of the environment by leveraging cooperation within a neighborhood of sensors. The key metric that guides the dynamic tuning is consistency of each sensor with its nearest neighbors: TL values are automatically adjusted on a per station basis to be more or less sensitive to produce consistent agreement of detections in its neighborhood. The AST algorithm adapts in near real-time to changing conditions in an attempt to automatically self-tune a signal detector to identify (detect) only signals from events of interest.

Peterson, Matthew↗

SULI Project Report: Mu2e otsdaq Documentation and Analytics

This report outlines the history of the CLFV puzzle, gives an overview of the Mu2e Experiment, and details the results of the DOE (Department of Energy)-funded SULI (Science Undergraduate Laboratory Internship) research completed over the summer 2024 on site at Fermilab. The project focused on the otsdaq software responsible for data acquisition. The project included drafting updated documentation for new users, including new procedures relevant for the Alma- Linux 9 operating system update, and the UPS package managing system replacement with Spack (scientific software package manager). A new art module (ReadTriggerCounts) to track trigger rates was created, with compatibility to be displayed via a Grafana server. The author also assisted in calorimeter cable installation in the detector hall.

Saarinen, Talia↗

Triggering Klystrons

To determine if klystrons will perform to the specifications of the LCLS (Linac Coherent Light Source) project, a new digital trigger controller is needed for the Klystron/Microwave Department Test Laboratory. The controller needed to be programmed and Windows based user interface software needed to be written to interface with the device over a USB (Universal Serial Bus). Programming the device consisted of writing logic in VHDL (VHSIC (Very High Speed Integrated Circuits) hardware description language), and the Windows interface software was written in C++. Xilinx ISE (Integrated Software Environment) was used to compile the VHDL code and program the device, and Microsoft Visual Studio 2005 was used to compile the C++ based Windows software. The device was programmed in such a way as to easily allow read/write operations to it using a simple addressing model, and Windows software was developed to interface with the device over a USB connection. A method of setting configuration registers in the trigger device is absolutely necessary to the development of a new triggering system, and the method developed will fulfill this need adequately. More work is needed before the new trigger system is ready for use. The configuration registers in the device need to be fully integrated with the logic that will generate the RF signals, and this system will need to be tested extensively to determine if it meets the requirements for low noise trigger outputs.

Stefan, Kelton D.↗

Measuring Cities with Software-Defined Sensors

The Chicago Array of Things (AoT) project, funded by the US National Science Foundation, created an experimental, urban-scale measurement capability to support diverse scientific studies. Initially conceived as a traditional sensor network, collaborations with many science communities guided the project to design a system that is remotely programmable to implement Artificial Intelligence (AI) within the devices-at the “edge” of the network-as a means for measuring urban factors that heretofore had only been possible with human observers, such as human behavior including social interaction. The concept of “software-defined sensors” emerged from these design discussions, opening new possibilities, such as stronger privacy protections and autonomous, adaptive measurements triggered by events or conditions. We provide examples of current and planned social and behavioral science investigations uniquely enabled by software-defined sensors as part of the SAGE project, an expanded follow-on effort that includes AoT.

97 MATHEMATICS AND COMPUTING↗

Online Data Handling and Storage at the CMS Experiment

During the LHC Long Shutdown 1, the CMS Data Acquisition (DAQ) system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and support new detector back-end electronics. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. All the metadata needed for bookkeeping are stored in files as well, in the form of small documents using the JSON encoding. The Storage and Transfer System (STS) is responsible for aggregating these files produced by the HLT, storing them temporarily and transferring them to the T0 facility at CERN for subsequent offline processing. The STS merger service aggregates the output files from the HLT from ~62 sources produced with an aggregate rate of ~2GB/s. An estimated bandwidth of 7GB/s in concurrent read/write mode is needed. Furthermore, the STS has to be able to store several days of continuous running, so an estimated of 250TB of total usable disk space is required. In this article we present the various technological and implementation choices of the three components of the STS: the distributed file system, the merger service and the transfer system.

Andre, J. M.↗

File-Based Data Flow in the CMS Filter Farm

During the LHC Long Shutdown 1, the CMS Data Acquisition system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and prepare the ground for future upgrades of the detector front-ends. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. This approach provides additional decoupling between the HLT algorithms and the input and output data flow. All the metadata needed for bookkeeping of the data flow and the HLT process lifetimes are also generated in the form of small “documents” using the JSON encoding, by either services in the flow of the HLT execution (for rates etc.) or watchdog processes. These “files” can remain memory-resident or be written to disk if they are to be used in another part of the system (e.g. for aggregation of output data). We discuss how this redesign improves the robustness and flexibility of the CMS DAQ and the performance of the system currently being commissioned for the LHC Run 2.

Andre, J. M.↗

Behavior-dependent Routing: Responding to Anomalies with Automated Low-cost Measures

This is a conference paper submission describing research and software implementation of a cybersecurity concept that uses behavior models to trigger changes in routing of network traffic. As user behavior deviates more and more from baseline models, traffic is routed through more elevated layers of analysis and control.

information flow controls↗

Mu2e otsdaq Documentation and Online Reconstruction Analytics

This report outlines the results of the DOE-funded SULI (Science Undergraduate Laboratory Internship) research completed over the summer 2024 on site at Fermilab. The project focused on the \textit{otsdaq} software responsible for data acquisition. The project included drafting updated documentation for new users including new procedures relevant for the Alma-Linux 9 operating system update, and the UPS package managing system replacement with spack (scientific software package manager). A new \textit{art} module (ReadTriggerCounts) to track trigger rates was created, with compatibility to be displayed via a Grafana server. The author also assisted in calorimeter cable installation in the detector hall.

Saarinen, Talia↗

SU-F-T-139: Meeting the Challenges of Quality Control in the TOPAS Monte Carlo Simulation Toolkit for Proton Therapy

Purpose: Monte Carlo particle transport simulation (MC) codes have become important tools in proton therapy and biology, both for research and practice. TOPAS is an MC toolkit serving users worldwide (213 licensed users at 95 institutions in 21 countries). It provides unprecedented ease in 4D placement of geometry components, beam sources and scoring through its user-friendly and reproducible parameter file interface. Quality control (QC) of stochastic simulation software is inherently difficult, and the versatility of TOPAS introduces additional challenges. But QC is vital as the TOPAS development team implements new features, addresses user feedback and reacts to upgrades of underlying software (i.e. Geant4). Methods: Whenever code is committed to our repository, over 50 separate module tests are automatically triggered via a continuous integration service. They check that the various module options execute successfully and that their results are statistically consistent with previous reference values. Prior to each software release, longer end-to-end tests automatically validate TOPAS against experimental data and a TOPAS benchmark. These include simulating multiple properties of spread-out Bragg peaks, validating nuclear models, and searching for differences in patient simulations. Results: Continuous integration has proven effective in catching regressions at the time they are introduced, particularly when implementing new features that involve refactoring code (e.g. multithreading and ntuple output). Code coverage statistics highlight untested portions of code and guide development of new tests. The various end-to-end tests demonstrate that TOPAS accurately describes the physics of proton therapy within clinical tolerances. Conclusion: The TOPAS QC strategy of frequent short tests and pre-release long tests has led to a more reliable tool. However, the versatility of TOPAS makes it difficult to predict how users might combine different modules, and so QC ultimately remains a partnership between the developer and the user. This work was funded by National Cancer Institute grant R01 CA 140735.

60 APPLIED LIFE SCIENCES↗

The artificial retina processor for track reconstruction at the LHC crossing rate

We present results of an R&D study for a specialized processor capable of precisely reconstructing, in pixel detectors, hundreds of charged-particle tracks from high-energy collisions at 40 MHz rate. We apply a highly parallel pattern-recognition algorithm, inspired by studies of the processing of visual images by the brain as it happens in nature, and describe in detail an efficient hardware implementation in high-speed, high-bandwidth FPGA devices. This is the first detailed demonstration of reconstruction of offline-quality tracks at 40 MHz and makes the device suitable for processing Large Hadron Collider events at the full crossing frequency.