Search NASA⌕ Search

SEARCH · Search NASA

Results for “solar concentrators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Multi-Objective Optimization of a Bi-Metal High-Temperature Recuperator for Application in Concentrating Solar Power

Supercritical CO 2 closed Brayton cycles are a major candidate for future power cycle designs in concentrating solar power applications, with high-temperature recuperators playing an essential role in realizing their high thermal efficiency. Here, printed circuit heat exchangers (PCHEs) are often chosen for this role due to their thermal-hydraulic and mechanical performance at high temperatures and pressures, all while remaining compact. However, PCHEs can be costly because of the high-performance materials demanded in these applications, and the heat exchanger internal geometry is restricted by their manufacturing process. Additively manufactured heat exchangers can address both of these shortcomings. This work proposes a modular bi-metal high-temperature recuperator with integrated headers to be produced with additive manufacturing. Beginning with existing PCHE channel geometries, a 1D heat exchanger model is developed. Then, multi-objective optimization is used to maximize the heat transfer effectiveness of a lab-scale device while limiting its size. Two distinct channel geometries emerge from the optimization. Optimal designs achieve up to 88% effectiveness with negligible pressure drop. Deterioration of effectiveness due to axial conduction of heat in the heat exchanger walls is found to be a notable problem for lab-scale PCHEs, and the optimal designs obtained here minimize its detrimental effects. A sensitivity analysis reveals that the effectiveness of the recuperator is much less sensitive to variation in mass flowrate in off-design operation when axial conduction is significant, while increasing the length of the device easily increases effectiveness.

14 SOLAR ENERGY↗

Black-Box Optimization for Design of Concentrating Solar Power and Photovoltaic Hybrid Systems with Optimal Dispatch Decisions

The hybridization of concentrating solar power (CSP) and photovoltaics (PV) can enable dispatchable renewable electricity generation at a lower price than current stand-alone CSP systems. However, designing a CSP-PV hybrid system can be challenging because of the many degrees of freedom in design that affect the internal and external system interactions and trade-offs. We develop a methodology to determine optimal designs for CSP-PV hybrids by implementing NLopt's derivative-free, or “black-box,” algorithms around pre-existing CSP-PV hybrid simulation software that utilizes the National Renewable Energy Laboratory’s System Advisor Model (SAM); we then employ a dispatch optimization model to determine operational decisions that maximize a plant’s profits. We present optimal designs for CSP-PV hybrid systems dispatching against four time-of-delivery (ToD) pricing structures. NLopt’s algorithms can improve the base case design’s power purchase agreement (PPA) price by 15% to 21%, depending on the ToD pricing structure. In addition, we present the resulting optimal CSP-PV hybrid design’s annual performance metrics, which tend to have capacity factors between 50% and 62%, but are able to generate electricity during the year’s highest-valued periods about 90% of the time. Lastly, we investigate the trade-offs between capacity factor and PPA price using Pareto fronts and demonstrate that, for some ToD pricing structures, the system capacity factor can increase by 20% but at the expense of a 2% increase in PPA price.

black-box↗

Measurements of Six-Junction Concentrator Solar Cells

Accurate measurements of six-junction inverted metamorphic concentrator solar cells under AM1.5 direct spectrum are obtained by adjusting the spectrum of a tunable high-intensity solar simulator with custom mirrors. Isotype reference cells and broadband InGaAs QE calibration cells were developed for accurate measurements. Modeling and varying the illumination show that an unavoidable 15% - 17% overillumination on the sixth junction does not result in significant error of these 6J IMM devices. Spectrally adjusted flash measurements are independently confirmed by NREL's Cell and Module Performance team. Concentration measurements of a 6J IMM solar cell resulted in 47.1 ± 3.2% (absolute) efficiency at 143 suns.

41 EE - Solar Energy Technologies Office (EE-4S)↗

One piece ceramic heat exchanger for concentrating solar power electric plants

Using additive manufacturing techniques, a ceramic heat exchanger was optimized for a concentrating solar power (CSP) electric power plant with a corrosive molten salt at atmospheric pressure as the solar field heat transfer fluid and supercritical carbon dioxide at 200 bar as the power block fluid. Temperatures ranged from 750 °C to 540 °C. The plant heat exchanger was optimized for heat transfer and stress using 1 m³ modules arranged in parallel. Heat transfer was optimized using COMSOL Multiphysics software resulting in a unique semi-elliptical cross section for the fluid flow channels in a counter-flow configuration. Counter-flow was made possible through additive manufacturing of the fluid headers as part of each modular heat exchanger thus producing the entire module as a single piece and minimizing cost. Using reasonable parametric values, a heat exchanger module was optimized to 0.5 MW/m³, and a section of it was manufactured including the fluid headers. Here, parametric studies showed the potential for a module to reach 3.5 MW/m³.

14 SOLAR ENERGY↗

Effect of temperature on abrasion erosion in particle based concentrating solar powerplants

The use of solid particles as a heat transfer medium is being explored for concentrated solar power plants (CSP) to increase their efficiency by achieving operating temperature >700 °C. During operation, these hot particles are expected to move along the various components within the collector system, resulting in material degradation from a combination of high-temperature oxidation and erosion. In the present study, the performance of candidate materials was evaluated through a series of abrasion erosion experiments at room temperature as well as at 800 °C. Wear in metallic and refractory type materials was investigated using CarboBead® HSP 40/70 particles inside a resistance heated kiln. Furthermore, cross-sectional scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) analysis on the specimens tested at 800 °C determined that the specific wear rate in Inconel 740H and stainless steel 316 metallic specimens was influenced by the thermally grown oxide morphology. High chromium Inconel 740H specimens exhibited greater resistance to wear with a steady state specific wear rate of 1.92E-4 mm 3 N -1 m –1 compared to 5.7E-3 mm 3 N -1 m –1 for Stainless Steel 316.

14 SOLAR ENERGY↗

Novel Lightweight, Low-Cost Heliostat for Concentrating Solar Power (SBIR Phase I Final Report)

The overall goal of this Department of Energy (DOE) SBIR Phase I project was to demonstrate the feasibility of the L.Garde, Inc. heliostat mirror facet for use in concentrated solar power applications. Prior to this Phase I project, L.Garde, Inc. developed a design for a lightweight and low cost mirror facet and successfully fabricated small scale (0.667 m 2 ) with a mirror surface flatness of 0.7 mrad. Therefore, the focus of the Phase I effort was to (1) demonstrate scalability by fabricating larger size mirrors while retaining the same mirror surface flatness, (2) demonstrate the design can withstand operating environment conditions through field testing, and (3) perform cost analysis to show the heliostat mirror facet design can meet DoE goals of < 12 kg/m2 and <$30/m 2 . During the Phase I project, L.Garde successfully fabricated large area (1.395 m 2 ) heliostat mirror facets, with a mass per unit area of 8 kg/m 2 and a cost of $29.80/m 2 . Surface flatness measurements (using contact probe technique) were performed on the mirror surface and results showed a flatness of 0.68 mrad, which were in agreement with previously fabricated small scale mirror facets. Slope error measurements was also performed on the mirror surface and results showed a slope error of 0.77 mrad which also was in agreement with previously fabricated small scale mirror facets. One large area mirror facet was subjected to a three (3) month field test. Surface flatness and slope error measurements were performed on the mirror surface after the field test and results were 0.663 mrad and 0.58 mrad respectively. The large scale heliostat mirror facets were also subjected to accelerated aging. However, during this exposure we observed failure due to the breaking of the mirror facets. Further investigation into the source of the failure showed that the mirror component alone showed signs of degradation during the same accelerated aging test. We believe that moisture ingress is occurring when subjected to high humidity, leading to buildup of water with the layers of protective paints and resulting in mirror breakage when water expands in freezing conditions. In order to mitigate or eliminate this issue, a new weatherproofing strategy may be implemented or a new mirror component may be used that is able to survive accelerated aging conditions.

14 SOLAR ENERGY↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗

Luminescent Solar Concentrator Tandem-on-Silicon with above 700mV Passivated Contact Silicon Bottom Cell

Luminescent solar concentrator (LSC) tandem-on-silicon (Si) provides a route towards achieving higher than 30% overall efficiency which can overcome the theoretical efficiency limit of a single junction Si cell. Here, we present optical coupling and performance of high Voc passivated contact Si bottom cell for LSC tandem-on-Si where the top module consists of highly efficient luminophores and an array of micro InGaP cells embedded in a poly (lauryl methacrylate) waveguide. In this device configuration, InGaP cell area coverage is only ~0.5% of the total LSC area which significantly reduces the high cost III-V material usage. The performance of Si sub-cell is investigated under LSC spectrum and is compared against the measurement done under 1 um thick InGaP filter which mimics the spectrum seen by Si bottom cell in a conventional III-V/Si tandem. V oc of greater than 700 mV has been observed for the passivated contact Si bottom cell in these tandem applications.

14 SOLAR ENERGY↗

Novel textured surfaces for superior corrosion mitigation in molten carbonate salts for concentrating solar power

Corrosion of metals in contact with molten salts used for thermal energy storage and heat transport at high temperatures is a serious impediment to the development of next-generation concentrating solar thermal systems. Toward addressing this limitation, novel multiscale fractal-textured Ni coatings on a variety of substrate alloys are presented in this study for exceptional corrosion mitigation in molten carbonate salts at a high temperature. Strongly adherent, durable, single-layer, and double-layer multiscale fractal coatings were fabricated using the electrodeposition method. Corrosion performance of the coatings on SS310, SS316, SS347, and In800H was studied in molten carbonate salt (32% Li 2 CO 3 +33% Na 2 CO 3 +35% K 2 CO 3 ) at 750 °C. Single-layer coatings are stable up to 300 h immersion, whereas double-layer coatings are stable beyond 750 h. The corrosion rate of double-layer Ni coatings on ferrous alloys was reduced by as much as 60% from that of uncoated surfaces and was about 18% below that of higher cost, high Ni content Ha230. The study represents the first-ever report of corrosion characteristics of alloys in carbonate salts at 750 °C and the first demonstration of a means of dramatically reducing corrosion in carbonate salts at a high temperature. The article is significant in that it provides a viable approach for low-cost structural alloys to be corrosion-resistant to molten carbonate heat transfer fluids and storage media in high-temperature concentrating solar thermal applications. Furthermore, the corrosion-resistant coatings provide opportunities for the use of low-cost, ferritic alloys instead of the expensive nickel-based alloys in practice.

14 SOLAR ENERGY↗

UHTC-TPMS Heat Exchangers for Concentrating Solar Power Applications with Thermal Energy Storage in Molten Chlorides

Concentrating solar power (CSP) plants convert energy from sunlight into electricity. Generally, a heliostat field is used to reflect sunlight and concentrate it onto a receiver, which heats the receiver and/or the media flowing through it. A flow loop transports the media through the system to a heat exchanger before returning the media back to the receiver to be reheated. The heat extracted by the heat exchanger is then converted into electricity using a conventional heat engine.

14 SOLAR ENERGY↗

FY19-FY21 Concentrating Solar Power Systems Analysis Final Report

This technical report summarizes work done by NREL over a 3-year period for the Concentrating Solar Power (CSP) Systems Analysis project for fiscal years 2019-2021 (FY19-FY21) in support of the Solar Energies Technology Office of the U.S. Department of Energy. The goal of the CSP Systems Analysis project is to provide timely and accurate CSP cost data to the U.S. Department of Energy's (DOE's) Solar Energy Technologies Office (SETO) and to project the performance and cost of emerging CSP technologies to inform research directions and industry investment.

14 SOLAR ENERGY↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Modeling receiver flux of commercial power tower concentrating solar power plants using ray tracing: a round-robin comparison of SolTrace, Solstice, and TieSOL

This study presents a multi-stage, cross-validation comparison of three software packages for Monte Carlo ray tracing (MCRT) applied to central tower concentrating solar power (CSP) systems. The three packages evaluated are: (1) SolTrace, an open-source tool developed by the National Renewable Energy Laboratory (NREL); (2) Solstice, an open-source program created by CNRS-PROMES and Meso-Star, with enhancements for CSP applications (called solsticepy) from the Australian National University; and (3) TieSOL, a commercial software developed by Tietronix. This investigation extends previous ray tracing comparisons by incorporating models of multi-facet heliostats within a commercial-scale solar field, taking into account zoned focal lengths and canting configurations. Receiver flux distributions were compared across the tools using a series of case studies, including single-heliostat scenarios, isolated blocking situations, and comprehensive full-field simulations. The case studies were designed to diagnose differences across the models at varying levels of complexity, and to identify and resolve discrepancies as additional parameters were introduced. Key factors examined in the analysis include sun positions, heliostat location, facet and canting focus, and aimpoint strategies. The comparison aims to improve the accuracy and reliability of these tools while providing benchmark cases for validating future optical modeling tools.

14 SOLAR ENERGY↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Elevating SolTrace's Capabilities for the Next Generation of Concentrating Solar Analysis

SolTrace is an open-source Monte Carlo ray tracing software developed at NREL. SolTrace can characterize concentrating solar thermal (CST) collector optical performance and is CST technology agnostic. Shown in Fig. 1, SolTrace is a foundational tool in NREL's CST system and component modeling suite. SolTrace's generic surface elements can flexibly model novel collector and receiver designs to predict spatial and temporal flux distributions - critical to understand for CST component design, performance prediction, and system integration. Since its initial development, SolTrace has over 1,650 references on Google Scholar, over 9,800 downloads since 2017, and has served the CST research and development community as a benchmark of 3rd party verification. SolTrace provides users with many options for defining surface shape and boundaries. However, SolTrace provides limited documentation which can result in a steep learning curve for new users. Additionally, SolTrace lacks the computational performance required to evaluate optical performance of a CST system over the course of a year and/or iteratively over design parameters in a timely manner. To address this, we are working towards a new release of SolTrace that enables increased computational throughput by implementing ray tracing acceleration structures and enabling GPU parallelization. Additionally, we are working to improve SolTrace's usability, accessibility, and maintainability by (1) automating solar position time-dependent simulation processes, (2) creating general CST collector templates of grouped elements, (3) updating the user interface to better visualize model inputs and outputs, and (4) creating a user support network through forums, "how to" videos, and documentation.

14 SOLAR ENERGY↗

Photovoltaic device for enhancing power output of concentrating solar thermal power plants

A photovoltaic retrofit device for a concentrating solar thermal power plant having a parabolic trough reflector, and a fluid receiver with working fluid therein spaced from the reflector and positioned at a focal point of the reflector. The photovoltaic device includes a plurality of adjustable angle dichroic mirrors positioned between the parabolic trough reflector and the fluid receiver. A photovoltaic receiver assembly has multiple photovoltaic panels in angular relationship to each other. A photovoltaic temperature regulating system includes a fluid medium to regulate temperature of the photovoltaic panels.

Otanicar, Todd↗

Advanced Characterization of Particulate Flows for Concentrating Solar Power Applications

The overarching goal of this project was to gain a greater fundamental understanding of heat and mass transfer in particulate-media in concentrated solar power (CSP) applications for thermal energy storage (TES) and to disseminate results to support parallel Gen3 research initiatives. Project objectives were achieved through three planned project phases to systematically characterize the heat transfer and flow properties for particulate (granular) flows at elevated temperatures up to 800 °C. These objectives were accomplished using a combination of fundamental experimental measurements, modeling, and simplified flow experiments over a range of temperatures. This work addressed a serious gap within the field related to the understanding and modeling of granular flow behavior and the related heat transfer at different temperatures, which directly correspond to the operating points of CSP applications which use particles for heat storage.

14 SOLAR ENERGY↗