Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid phase extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Distributed sustainable metals production: opportunities for intensifying separations & alternative feedstocks

Meeting the increased demand for rare earth elements and beyond primary mined ore. Secondary sources like phosphogypsum, coal fly ash, used nuclear fuel, and electronic waste are concentrated sources of critical minerals. One strategy for a resilient supply chain is to decentralize sourcing and hydrometallurgical processing of metals. Rotating packed beds (RPBs) for solid-phase extraction and liquid-liquid extraction are gaining momentum for their ability to increase process throughput by 5-10x the state of the art. In conclusion, this review discusses advances in hydrometallurgical RPB processes and opportunities for implementation in distributed metals production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phthalate exposure associated with self-reported diabetes among Mexican women

Background: Phthalates are ubiquitous industrial chemicals used as plasticizers in plastics made of polyvinyl chloride (PVC) to confer flexibility and durability. They are also present in products used for personal-care, industry and in medical devices. Phthalates have been associated with several adverse health effects, and recently it has been proposed that exposure to phthalates, could have an effect on metabolic homeostasis. This exploratory cross-sectional study evaluated the possible association between phthalate exposure and self-reported diabetes among adult Mexican women. Methods: As part of an on-going case-control study for breast cancer, only controls were selected, which constituted 221 healthy women matched by age ({+-}5 years) and place of residence with the cases. Women with diabetes were identified by self-report. Urinary concentrations of nine phthalate metabolites were measured by online solid phase extraction coupled to high performance liquid chromatography-isotope-dilution tandem mass spectrometry. Results: Participants with diabetes had significantly higher concentrations of di(2-ethylhexyl) pththalate (DEHP) metabolites: mono(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP), mono(2-ethyl-5-oxohexyl) phthalate (MEOHP) and mono(2-ethyl-5-carboxypentyl) phthalate (MECPP) but lower levels of monobenzyl phthalate (MBzP) a metabolite of benzylbutyl phthalate, compared to participants without diabetes. A marginally significant positive associations with diabetes status were observed over tertiles with MEHHP (OR{sub T3vs.T1}=2.66; 95% CI: 0.97-7.33; p for trend=0.063) and MEOHP (OR{sub T3vs.T1}=2.27; 95% CI; 0.90-5.75; P for trend=0.079) even after adjusting for important confounders. Conclusions: The results suggest that levels of some phthalates may play a role in the genesis of diabetes. - Highlights: {yields} This study evaluated phthalate exposure and diabetes status among Mexican women. {yields} Urinary phthalates metabolite concentrations were used to determine association. {yields} Participants with diabetes had higher concentrations of three DEHP metabolites. {yields} A positive association with diabetes status was found with MEHHP and MEOHP metabolites. {yields} Results suggest phthalate exposure can have a role in diabetes.

60 APPLIED LIFE SCIENCES↗

Urinary concentrations of environmental phenols in pregnant women in a pilot study of the National Children's Study

Environmental phenols are a group of chemicals with widespread uses in consumer and personal care products, food and beverage processing, and in pesticides. We assessed exposure to benzophenone-3, bisphenol A (BPA), triclosan, methyl- and propyl parabens, and 2,4- and 2,5-dichlorophenol or their precursors in 506 pregnant women enrolled in the National Children's Study (NCS) Vanguard Study. We measured the urinary concentrations of the target phenols by using online solid-phase extraction–isotope dilution high performance liquid chromatography–tandem mass spectrometry. NCS women results were compared to those of 524 similar-aged women in the National Health and Nutrition Examination Survey (NHANES) 2009–2010, and to 174 pregnant women in NHANES 2005–2010. In the NCS women, we found significant racial/ethnic differences (p<0.05) in regression adjusted mean concentrations of benzophenone-3, triclosan, 2,4- and 2,5-dichlorophenol, but not of BPA. Urinary 2,4- and 2,5-dichlorophenol concentrations were highly correlated (r=0.66, p<0.0001). Except for BPA and triclosan, adjusted mean concentrations were significantly different across the 7 study sites. Education was marginally significant for benzophenone-3, triclosan, propyl paraben, and 2,5-dichlorophenol. Urinary concentrations of target phenols in NCS pregnant women and U.S. women and pregnant women were similar. In NCS pregnant women, race/ethnicity and geographic location determined urinary concentrations of most phenols (except BPA), suggesting differential exposures. NCS Main Study protocols should collect urine biospecimens and information about exposures to environmental phenols. - Highlights: • Limited biomonitoring data are available in pregnant women. • Seven urinary phenols were measured in 506 third trimester women enrolled in the NCS. • Urine benzophenone-3, triclosan, 2,4- and 2,5-dichlorophenol differed by race/ethnicity. • Urinary concentrations of 2,4- and 2,5-dichlorophenol were highly correlated. • Exposure information can expand the utility of biospecimens in the NCS Main Study.

54 ENVIRONMENTAL SCIENCES↗

Municipal wastewater affects adipose deposition in male mice and increases 3T3-L1 cell differentiation

Trace concentration of EDs (endocrine disrupting compounds) in water bodies caused by wastewater treatment plant effluents is a recognized problem for the health of aquatic organisms and their potential to affect human health. In this paper we show that continuous exposure of male mice from early development to the adult life (140 days) to unrestricted drinking of wastewater collected from a municipal sewage treatment plant, is associated with an increased adipose deposition and weight gain during adulthood because of altered body homeostasis. In parallel, bisphenol A (BPA) at the administration dose of 5 μg/kg/body weight, shows an increasing effect on total body weight and fat mass. In vitro, a solid phase extract (SPE) of the wastewater (eTW), caused stimulation of 3T3-L1 adipocyte differentiation at dilutions of 0.4 and 1 % in the final culture medium which contained a concentration of BPA of 40 nM and 90 nM respectively. Pure BPA also promoted adipocytes differentiation at the concentration of 50 and 80 μM. BPA effect in 3T3-L1 cells was associated to the specific activation of the estrogen receptor alpha (ERα) in undifferentiated cells and the estrogen receptor beta (ERβ) in differentiated cells. BPA also activated the Peroxisome Proliferator Activated Receptor gamma (PPARγ) upregulating a minimal 3XPPARE luciferase reporter and the PPARγ-target promoter of the aP2 gene in adipose cells, while it was not effective in preadipocytes. The pure estrogen receptor agonist diethylstilbestrol (DES) played an opposite action to that of BPA inhibiting PPARγ activity in adipocytes, preventing cell differentiation, activating ERα in preadipocytes and inhibiting ERα and ERβ regulation in adipocytes. The results of this work show that the drinking of chemically-contaminated wastewater promotes fat deposition in male mice and that EDs present in sewage are likely responsible for this effect through a nuclear receptor-mediated mechanism. - Highlights: • Sewage watewaters (TW) sampled from a Municipal Treatment Sewage Plant are biologically active in mice and in vitro. • In male mice TW promotes an increase in adipose mass deposition following exposure from foetal to adult life. A similar effect is produced by BPA. • The expression of key genes of the adipose metabolism is increased in epidydimal fat both by TW and BPA. • An extract from the TW which concentrated the contained chemicals by a factor of 1000, is able to stimulate 3T3-L1 adipocyte differentiation. • The major chemicals contained in the TW, bisphenol A and nonylphenol, are able to promote adipocyte differentiation at the low environmentally relevant doses as are found in the TW.

60 APPLIED LIFE SCIENCES↗

Polysialylated N-Glycans Identified in Human Serum Through Combined Developments in Sample Preparation, Separations and Electrospray ionization-mass spectrometry

The N-glycan diversity of human serum glycoproteins, i.e. the human blood serum N-glycome, is complex due to the range of glycan structures potentially synthesizable by human glycosylation enzymes. The reported glycome, however, is limited by methods of sample preparation, available analytical platforms, e.g., based upon electrospray ionization-mass spectrometry (ESI-MS), and software tools for data analysis. In this report, several improvements have been implemented in sample preparation and analysis to extend ESI-MS glycan characterization and to provide an improved view of glycan diversity. Sample preparation improvements include acidified, microwave-accelerated, PNGase F N-glycan release, and sodium borohydride reduction were optimized to improve quantitative yields and conserve the number of glycoforms detected. Two-stage desalting (during solid phase extraction and on the analytical column) increased the sensitivity by reducing analyte signal division between multiple reducing-end-forms or cation adducts. On-line separations were improved by using extended length graphitized carbon columns and adding TFA as an acid modifier to a formic acid/reversed phase gradient which provides additional resolving power and significantly improved desorption of both large and heavily sialylated glycans. To improve MS sensitivity and provide gentler ionization conditions at the source-MS interface, subambient pressure ionization with nanoelectrospray (SPIN) has been utilized. When method improvements are combined together with the Glycomics Quintavariate Informed Quantification (GlyQ-IQ) recently described1 these technologies demonstrate the ability to significantly extend glycan detection sensitivity and provide expanded glycan coverage. We demonstrate application of these advances in the context of the human serum glycome, and for which our initial observations include detection of a new class of heavily sialylated N-glycans, including polysialylated N-glycans.

Environmental Molecular Sciences Laboratory↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

Confocal Raman Microscopy Investigation of Molecular Transport into Individual Chromatographic Silica Particles

Porous silica is used as a support in a variety of separation processes, including chromatographic separation and solid-phase extraction. The resolution and efficiency of these applications is significantly impacted by the kinetics of partitioning and molecular transport into the interior of the porous particles. Molecular transport in porous silica has been explored previously by measuring chromatographic elution profiles, but such measurements are limited to relatively low retention conditions, where within-particle molecular transport must be inferred from elution profiles of solutes emerging from a packed column. In this work, a measurement of within-particle molecular transport is carried out using confocal Raman microscopy to probe the time-dependent accumulation of pyrene from an aqueous mobile phase into the center of individual C 18 -chromatographic particles. The measured time constants for pyrene accumulation were much slower than diffusion-limited transport of solute in solution to the particle surface. Furthermore, the accumulation into the center of the particle did not show a time-lag characteristic of slow-transport into the particle interior. The exponential rise of pyrene concentration is, however, consistent with first-order Langmuir adsorption kinetics at low surface coverages. The linear dependence of the time-constant on particle radius indicates an adsorption barrier near the outer boundary of the particle, where the accumulation rate depends on flux across the boundary (proportional to the particle area) to satisfy the within-particle capacity at equilibrium (proportional to the particle volume). The pyrene accumulation kinetics into the porous particle, expressed as a heterogeneous rate constant, were nearly 50-times faster than the pyrene adsorption rate at a planar C 18 -functionalized silica surface, which demonstrates the impact of multiple surface encounters within the porous structure leading to much greater capture efficiency compared to a planar surface. Monte Carlo simulations of within-particle pyrene diffusion, with the adsorption efficiency estimated from the planar-surface adsorption rate, predict a diffusion-to-capture distance within the porous particle that is within 40% of that observed in the radial dependence of the pyrene within-particle accumulation results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample Preparation Methods for Targeted Single-Cell Proteomics

We compared three cell isolation and two proteomic sample preparation methods for single-cell and near-single-cell analysis. Whole blood was used to quantify hemoglobin (Hb) and glycated-Hb (gly-Hb) in erythrocytes using targeted mass spectrometry and stable isotope-labeled standard peptides. Each method differed in cell isolation and sample preparation as follows: 1) FACS and automated preparation in one-pot for trace samples (autoPOTS); 2) limited dilution via microscopy and a novel rapid one-pot sample preparation method that circumvented the need for the solid-phase extraction, low-volume liquid handling instrumentation and humidified incubation chamber; and 3) CellenONE-based cell isolation and the same one-pot sample preparation method used for limited dilution. Only the CellenONE device routinely isolated single-cells from which Hb was measured to be 540–660 amol per red blood cell (RBC), which was comparable to the calculated SI reference range for mean corpuscular hemoglobin (390–540 amol/RBC). FACSAria sorter and limited dilution could routinely isolate single-digit cell numbers, to reliably quantify CMV-Hb heterogeneity. Finally, we observed that repeated measures, using 5–25 RBCs obtained from N = 10 blood donors, could be used as an alternative and more efficient strategy than single RBC analysis to measure protein heterogeneity, which revealed multimodal distribution, unique for each individual.

59 BASIC BIOLOGICAL SCIENCES↗

Preparation and Characterization of Au-ZrO2-SiO2 Nanocomposite Spheres and Their Application in Enrichment and Detection of Organophosphorus Agents

Au-ZrO{sub 2}-SiO{sub 2} nanocomposite spheres were synthesized and used as selective sorbents for the solid-phase extraction (SPE) of orananophosphorous agents. A non-enzymatic electrochemical sensor based on an Au-ZrO{sub 2}-SiO{sub 2} modified electrode was developed for selective detection of orananophosphorous pesticides (OPs). The Au-ZrO{sub 2}-SiO{sub 2} nanocomposite spheres were synthesized by hydrolysis and condensation of zirconia n-butoxide (TBOZ) on the surface of SiO{sub 2} spheres and then introduction of gold nanoparticles on the surface. Transmission electron microscope and X-ray photoelectron spectroscopy were performed to characterize the formation of the nanocomposite sphere. Fast extraction of OP was achieved by Au-ZrO{sub 2}-SiO{sub 2} modified electrode within 5 min via the specific affinity between zirconia and phosphoric group. The assay yields a broad concentration range of paraoxon-ethyl from 1.0 to 500 ng/mL{sup -1} with a detection limit 0.5 ng/mL{sup -1}. This selective and sensitive method holds great promise for the enrichment and detection of OPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast gas chromatographic separation of biodiesel.

A high-speed gas chromatographic method has been developed to determine the FAME distribution of B100 biodiesel. The capillary column used in this work has dimensions of 20 m x 0.100 mm and is coated with a polyethylene glycol film. Analysis times are typically on the order of 4-5 min depending upon the composition of the B100. The application of this method to a variety of vegetable and animal derived B100 is demonstrated. Quantitative results obtained with this method were in close agreement with those obtained by a more conventional approach on a 100 m column. The method, coupled with solid-phase extraction, was also found suitable to determine the B100 content of biodiesel-diesel blends.

33 ADVANCED PROPULSION SYSTEMS↗

Quantitative Method Development and Validation of Naloxone and 6α‐naloxol from Male African Green Monkey Plasma.

Theopioid epidemic is a rapidly growing crisis around the world. Current models forpharmacokinetic assessment of countermeasures use African green monkeys (AGM). Arapid, sensitive and selective method was developed and validated usingLC‐MS/MS for the determination of naloxone and 6α‐naloxol in AGM plasma. Samplepreparation involved a simple solid phase extraction (SPE) using ahydrophilic‐lipophilic‐balanced reversed‐phase cartridge. Separation of naloxoneand 6α‐naloxol was achieved on a Halo C18, 2.1 × 50 mm, 2.7μ analytical columnusing an Agilent 1290 Infinity HPLC. A solvent system of methanol‐water‐formicacid was used for the elution of analytes. The analytes were detected and monitoredby a SCIEX QTRAP 6500 + triple quadrupole tandem mass spectrometer operatedin electrospray ionization (ESI) positive mode and multiple reaction monitoring(MRM). Molecular ion transitions for naloxone, 6α‐naloxol and naloxone‐D5 were 328.0/212.0,330.0/185.0, and 333.1/212.0 m/z, respectively. The method was validated usingcalibration and recovery assays with spiked samples. Linear calibration curveswere generated over the range of 1.5–100 ng/ml with values for the coefficientof determination (R 2 ) of >0.9950. The values for both inter‐dayand intra‐day precision and accuracy were well within the generally acceptedcriteria for analytical methods (≤15%). This method was subsequentlyused to measure plasma concentrations of naloxone and 6α‐naloxol in male AGMs administerednaloxone subcutaneously and intravenously. The developed method demonstratedexcellent recovery, repeatability, accuracy and sensitivity. Support or Funding Information DISCLAIMERS. The views expressed in this abstractare those of the authors (s) and do not reflect the official policy of theDepartment of Army, Department of Defense, or U. S. Government. This researchwas supported by the Defense Threat Reduction Agency – Joint Science andTechnology office, Medical S&T Division. Thisproject was supported in part by an appointment to the Research ParticipationProgram for the U.S. Army Medical Research and Materiel Command administratedby the Oak Ridge Institute for Science and Education through an agreementbetween the U.S. Army Medical Research and Materiel Command. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Bandaru, Veera Venkata Ratnam↗

Optimization for Peptide Sample Preparation for Urine Peptidomics

Analysis of native or endogenous peptides in biofluids can provide valuable insights into disease mechanisms. Furthermore, the detected peptides may also have utility as potential biomarkers for non-invasive monitoring of human diseases. The non-invasive nature of urine collection and the abundance of peptides in the urine makes analysis by high-throughput ‘peptidomics’ methods , an attractive approach for investigating the pathogenesis of renal disease. However, urine peptidomics methodologies can be problematic with regards to difficulties associated with sample preparation. The urine matrix can provide significant background interference in making the analytical measurements that it hampers both the identification of peptides and the depth of the peptidomics read when utilizing LC-MS based peptidome analysis. We report on a novel adaptation of the standard solid phase extraction (SPE) method to a modified SPE (mSPE) approach for improved peptide yield and analysis sensitivity with LC-MS based peptidomics in terms of time, cost, clogging of the LC-MS column, peptide yield, peptide quality, and number of peptides identified by each method. Expense and time requirements were comparable for both SPE and mSPE, but more interfering contaminants from the urine matrix were evident in the SPE preparations (e.g., clogging of the LC-MS columns, yellowish background coloration of prepared samples due to retained urobilin, lower peptide yields) when compared to the mSPE method. When we compared data from technical replicates of 4 runs, the mSPE method provided significantly improved efficiencies for the preparation of samples from urine (e.g., mSPE peptide identification 82% versus 18% with SPE; p = 8.92E-05). Additionally, peptide identifications, when applying the mSPE method, highlighted the biology of differential activation of urine peptidases during acute renal transplant rejection with distinct laddering of specific peptides, which was obscured for most proteins when utilizing the conventional SPE method. In conclusion, the mSPE method was found to be superior to the conventional, standard SPE method for urine peptide sample preparation when applying LC-MS peptidomics analysis due to the optimized sample clean up that provided improved experimental inference from the confidently identified peptides.

biomarker↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

Chemical characterization of some aqueous leachates from crop residues in 'CELSS'

Aqueous leachate samples prepared from crop residues that are produced as a component of the Controlled Ecological Life Support System program designed to support long duration space missions have been compared and general chemical characterization has been accomplished. Solid phase extraction and high performance liquid chromatography were used to accomplish comparisons based on chromatographic and ultraviolet absorption properties of the components that are present. Specific compounds were not identified, however, general composition related to the presence of phenol-like compounds was explored.

Madsen, Brooks C.↗

Chemical characterization of some aerobic liquids in CELSS

Untreated aqueous soybean and wheat leachate and aerobically treated wheat leachate prepared from crop residues that are produced as a component of the Controlled Ecological Life Support System program designed to support long duration space missions were compared, and a general chemical characterization was accomplished. Solid phase extraction and high performance liquid chromatography were used to accomplish comparisons based on chromatographic and ultraviolet absorption properties of the components that are present. Specific compounds were not identified; however, general composition related to the initial presence of phenol-like compounds and their disappearance during aerobic treatment was explored.

Madsen, Brooks C.↗

Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy

A new, rapid methodology for trace analysis using solid-phase extraction is described. The two-step methodology is based on the concentration of an analyte onto a membrane disk and on the determination by diffuse reflectance spectroscopy of the amount of analyte extracted on the disk surface. This method, which is adaptable to a wide range of analytes, has been used for monitoring ppm levels of iodine and iodide in spacecraft water. Iodine is used as a biocide in spacecraft water. For these determinations, a water sample is passed through a membrane disk by means of a 10-mL syringe that is attached to a disk holder assembly. The disk, which is a polystyrene-divinylbenzene composite, is impregnated with poly(vinylpyrrolidone) (PVP), which exhaustively concentrates iodine as a yellow iodine-PVP complex. The amount of concentrated iodine is then determined in only 2 s by using a hand-held diffuse reflectance spectrometer by comparing the result with a calibration curve based on the Kubelka-Munk function. The same general procedure can be used to determine iodide levels after its facile and exhaustive oxidation to iodine by peroxymonosulfate (i.e., Oxone reagent). For samples containing both analytes, a two-step procedure can be used in which the iodide concentration is calculated from the difference in iodine levels before and after treatment of the sample with peroxymonosulfate. With this methodology, iodine and iodide levels in the 0.1-5.0 ppm range can be determined with a total workup time of approximately 60 s with a RSD of approximately 6%.

Non-NASA Center↗

Intestinal transport of gentamicin with a novel, glycosteroid drug transport agent

PURPOSE: The objective was to investigate the ability of a glycosteroid (TC002) to increase the oral bioavailability of gentamicin. METHODS: Admixtures of gentamicin and TC002 were administered to the rat ileum by injection and to dogs by ileal or jejunal externalized ports, or PO. Bioavailability of gentamicin was determined by HPLC. 3H-TC002 was injected via externalized cannulas into rat ileum or jejunum, or PO and its distribution and elimination was determined. The metabolism of TC002 in rats was evaluated by solid phase extraction and HPLC analysis of plasma, urine and feces following oral or intestinal administration. RESULTS: The bioavailability of gentamicin was substantially increased in the presence of TC002 in both rats and dogs. The level of absorption was dependent on the concentration of TC002 and site of administration. Greatest absorption occurred following ileal orjejunal administration. TC002 was significantly more efficacious than sodium taurocholate, but similar in cytotoxicity. TC002 remained primarily in the GI tract following oral or intestinal administration and cleared rapidly from the body. It was only partly metabolized in the GI tract, but was rapidly and completely converted to its metabolite in plasma and urine. CONCLUSIONS: TC002 shows promise as a new drug transport agent for promoting intestinal absorption of polar molecules such as gentamicin.

Non-NASA Center↗

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang↗