Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

WE-G-17A-01: Improving Tracking Image Spatial Resolution for Onboard MR Image Guided Radiation Therapy Using the WHISKEE Technique

Purpose: To evaluate the feasibility of using the weighted hybrid iterative spiral k-space encoded estimation (WHISKEE) technique to improve spatial resolution of tracking images for onboard MR image guided radiation therapy (MR-IGRT). Methods: MR tracking images of abdomen and pelvis had been acquired from healthy volunteers using the ViewRay onboard MRIGRT system (ViewRay Inc. Oakwood Village, OH) at a spatial resolution of 2.0mm*2.0mm*5.0mm. The tracking MR images were acquired using the TrueFISP sequence. The temporal resolution had to be traded off to 2 frames per second (FPS) to achieve the 2.0mm in-plane spatial resolution. All MR images were imported into the MATLAB software. K-space data were synthesized through the Fourier Transform of the MR images. A mask was created to selected k-space points that corresponded to the under-sampled spiral k-space trajectory with an acceleration (or undersampling) factor of 3. The mask was applied to the fully sampled k-space data to synthesize the undersampled k-space data. The WHISKEE method was applied to the synthesized undersampled k-space data to reconstructed tracking MR images at 6 FPS. As a comparison, the undersampled k-space data were also reconstructed using the zero-padding technique. The reconstructed images were compared to the original image. The relatively reconstruction error was evaluated using the percentage of the norm of the differential image over the norm of the original image. Results: Compared to the zero-padding technique, the WHISKEE method was able to reconstruct MR images with better image quality. It significantly reduced the relative reconstruction error from 39.5% to 3.1% for the pelvis image and from 41.5% to 4.6% for the abdomen image at an acceleration factor of 3. Conclusion: We demonstrated that it was possible to use the WHISKEE method to expedite MR image acquisition for onboard MR-IGRT systems to achieve good spatial and temporal resolutions simultaneously. Y. Hu and O. green receive travel reimbursement from ViewRay. S. Mutic has consulting and research agreements with ViewRay. Q. Zeng, R. Nana, J.L. Patrick, S. Shvartsman and J.F. Dempsey are ViewRay employees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field dynamic responses of structures by a combination of high-spatial-resolution modal model and video motion manipulations

Structures with complex geometries, material properties, and boundary conditions exhibit spatially local dynamic behaviors. A high-spatial-resolution model of the structure is thus required for high-fidelity analysis, assessment, and prediction of the dynamic phenomena of the structure. The traditional approach is to build a highly refined finite element computer model for simulating and analyzing the structural dynamic phenomena based on detailed knowledge and explicit modeling of the structural physics such as geometries, materials properties, and boundary conditions. These physics information of the structure may not be available or accurately modeled in many cases, however. In addition, the simulation on the high-spatial-resolution structural model, with a massive number of degrees of freedom and system parameters, is computationally demanding. Here this study, on a proof-of-principle basis, proposes a novel alternative approach for spatiotemporal video-domain high-fidelity simulation and realistic visualization of full-field structural dynamics by an innovative combination of the fundamentals of structural dynamic modeling and the advanced video motion manipulation techniques. Specifically, a low-modal-dimensional yet high-spatial (pixel)-resolution (as many spatial points as the pixel number on the structure in the video frame) modal model is established in the spatiotemporal video domain with full-field modal parameters first estimated from line-of-sight video measurements of the operating structure. Then in order to simulate new dynamic response of the structure subject to a new force, the force is projected onto each modal domain, and the modal response is computed by solving each individual single-degree-of-freedom system in the modal domain. The simulated modal responses are then synthesized by the full-field mode shapes using modal superposition to obtain the simulated full-field structural dynamic response. Finally, the simulated structural dynamic response is embedded into the original video, replacing the original motion of the video, thus generating a new photo-realistic, physically accurate video that enables a realistic, high-fidelity visualization/animation of the simulated full-field vibration of the structure. Laboratory experiments are conducted to validate the proposed method, and the error sources and limitations in practical implementations are also discussed. Compared with high-fidelity finite element computer model simulations of structural dynamics, the video-based simulation method removes the need to explicitly model the structure's physics. In addition, the photo-realistic, physically accurate simulated video provides a realistic visualization/animation of the full-field structural dynamic response, which was not traditionally available. Lastly, these features of the proposed method should enable a new alternative to the traditional computer-aided finite element model simulation for high-fidelity simulating and realistically visualizing full-field structural dynamics in a relatively efficient and user-friendly manner.

42 ENGINEERING↗

Polymeric spatial resolution test patterns for mass spectrometry imaging using nano-thermal analysis with atomic force microscopy

As the spatial resolution of mass spectrometry imaging technologies has begun to reach into the nanometer regime, finding readily available or easily made resolution reference materials has become particularly challenging for molecular imaging purposes. This study describes the fabrication, characterization and use of vertical line array polymeric spatial resolution test patterns for nano-thermal analysis/atomic force microscopy/mass spectrometry chemical imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of spatial resolution in breast CT at UC Davis

Purpose: Dedicated breast computed tomography (bCT) technology for the purpose of breast cancer screening has been a focus of research at UC Davis since the late 1990s. Previous studies have shown that improvement in spatial resolution characteristics of this modality correlates with greater microcalcification detection, a factor considered a potential limitation of bCT. The aim of this study is to improve spatial resolution as characterized by the modulation transfer function (MTF) via changes in the scanner hardware components and operational schema. Methods: Four prototypes of pendant-geometry, cone-beam breast CT scanners were designed and developed spanning three generations of design evolution. To improve the system MTF in each bCT generation, modifications were made to the imaging components (x-ray tube and flat-panel detector), system geometry (source-to-isocenter and detector distance), and image acquisition parameters (technique factors, number of projections, system synchronization scheme, and gantry rotational speed). Results: Characterization of different generations of bCT systems shows these modifications resulted in a 188% improvement of the limiting MTF properties from the first to second generation and an additional 110% from the second to third. The intrinsic resolution degradation in the azimuthal direction observed in the first generation was corrected by changing the acquisition from continuous to pulsed x-ray acquisition. Utilizing a high resolution detector in the third generation, along with modifications made in system geometry and scan protocol, resulted in a 125% improvement in limiting resolution. An additional 39% improvement was obtained by changing the detector binning mode from 2 × 2 to 1 × 1. Conclusions: These results underscore the advancement in spatial resolution characteristics of breast CT technology. The combined use of a pulsed x-ray system, higher resolution flat-panel detector and changing the scanner geometry and image acquisition logic resulted in a significant fourfold improvement in MTF.

60 APPLIED LIFE SCIENCES↗

DARK MATTER HALOS AND EVOLUTION OF BARS IN DISK GALAXIES: VARYING GAS FRACTION AND GAS SPATIAL RESOLUTION

We conduct numerical experiments by evolving gaseous/stellar disks embedded in live dark matter halos aiming at quantifying the effect of gas spatial resolution and gas content on the bar evolution. Three model sequences have been constructed using different resolutions, and the gas fraction has been varied along each sequence within the range of f{sub g} = 0%-50%, but keeping the disk and halo properties unchanged. We find that the spatial resolution becomes important with an increase in the gas content. For the higher resolution model sequences, we observe a bimodal behavior in the bar evolution with respect to the gas fraction, especially during the secular phase of this evolution. The switch from the gas-poor to gas-rich behavior is abrupt and depends on the resolution used, being reasonably confined to f{sub g} {approx} 5%-12%. The diverging evolution has been observed in nearly all basic parameters characterizing bars, such as the bar strength, central mass concentration, bar vertical buckling amplitude, bar size, etc. We find that the presence of the gas component severely limits the bar growth and affects its pattern speed evolution. Gas-poor models display rapidly decelerating bars, while gas-rich models exhibit bars with constant or even slowly accelerating tumbling. We also find that the gas-rich models have bar corotation (CR) radii within the disk at all times, in contrast with gas-poor and purely stellar disks. In addition, the CR-to-bar size ratio is less than 2 for gas-rich models. Next, we have confirmed that the disk angular momentum within the CR remains unchanged in the gas-poor models, as long as the CR stays within the disk, but experiences a sharp drop before leveling off in the gas-rich models. Finally, we discuss a number of observed correlations between various parameters of simulated bars, such as between the bar sizes and the gas fractions, between the bar strength and the buckling amplitude, and between the bar strength and its size, etc.

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution Raman thermometry analysis of TiO 2 microparticles

A new technique of high-resolution micro-Raman thermometry using anatase TiO2microparticles (0.5-3 μm) is presented. These very high spatial resolution measurements (280 nm) reveal temperature gradients even within individual microparticles. Potential applications of this technique are demonstrated by probing the temperature distribution of a micro-fabricated heater consisting of a thin silicon nitride (Si-N) membrane with a gold coil on top of the membrane. Using TiO 2 microparticle micro-Raman thermometry, the temperature from the outer edge of the coil to the inner portion was measured to increase by ∼40 °C. These high spatial resolution microscopic measurements were also used to measure the temperature gradient within the 20 μm wide Si-N between the gold heating coils. 2D numerical simulations of the micro heater temperature distribution are in excellent agreement with the experimental measurements of the temperatures. These measurements illustrate the potential to extend applications of micro-Raman thermometry to obtain temperature details on a sub-micrometer spatial resolution by employing microparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Spatial Resolution for Reflection Mode Infrared Microscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the umerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using two different microscopes apable of diffraction-limited resolution: the first microscope is coupled to a synchrotron source and utilizes a single point detector, whereas the second microscope has a standard blackbody source and uses a focal planetarray (FPA) detector.

47 OTHER INSTRUMENTATION↗

Improved Spatial Resolution For Reflection Mode Infrared Spectromicroscopy

Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the numerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using a microscope coupled to a synchrotron source.

43 PARTICLE ACCELERATORS↗

Spatial resolution of a hard x-ray CCD detector

The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20{mu}m pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95{mu}m (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Spatial Resolution STXM at 6.2 keV Photon Energy

We report on a zone-doubling technique that bypasses the electron-beam lithography limitations for the production of X-ray diffractive optics and enables the fabrication of Fresnel zone plates with smaller outermost zone widths than other well-established approaches. We have applied this method to manufacture hard X-ray Fresnel zone plates with outermost zone widths of 25 and 20 nm. These lenses have been tested in scanning transmission X-ray microscopy (STXM) at energies up to 6.2 keV, producing images of test structures that demonstrate a spatial resolution of 25 nm. High spatial resolution STXM images of several biological specimens have been acquired in transmission, dark-field and differential phase contrast modes.

36 MATERIALS SCIENCE↗

How important is spatial resolution: Case studies at 48, 12 and 4 km for the U.S., Latin America and Southern Asia

A critical role for regional climate models is downscaling coarse spatial resolution global model simulations of climate change to the much higher resolution required for assessment of regional changes and impacts. But what degree of downscaling is required? Fully coupled global climate models typically have resolutions of at best 100-200 km. The most recent set of IPCC reports suggest that the scale of regional/local impacts to climate change are on the order of 10 km. The scale mismatch is obvious, but less clear is what degree the climate simulations must be downscaled to meet the needs of impacts studies - other non-climate factors might also be crucial or even dominant. We have made a series of simulations with the WRF ARW for the U.S., large portions of Latin America, and South and Southeast Asia. Each set of runs includes a large outer domain at 48 km; an intermediate domain at 12 km (that is the primary basis for model results and interpretations); and one or more 'exploratory' inner domains at 4 km. The latter include regions with complex topography as well as both homogeneous and inhomogeneous land surface types. For each region a multi-year control forced by NCEP reanalyses has been made. Experiments for Asia are focusing on the effects of deforestation, while those for the U.S. and Latin America are focusing on IPCC climate change scenarios (A1FI for the U.S. and A2 for Latin America). Large-scale forcings for the latter two are provided by NCAR CCSM IPCC AR4 simulations. Preliminary results suggest that the higher resolutions have much more structure in standard climate quantities such as temperature or precipitation. Less obvious, however, is how realistic these structures are. In some cases, they clearly follow the better resolution of topography; in other instances the reason is less certain. Furthermore, observational datasets are frequently inadequate in assessing realism, especially for the non-U.S. domains. Finally, this work raises the issue of the trade-off between the length and the resolution of regional climate model simulations. Which is more important - long runs at medium resolution, or shorter runs at higher resolution?

54 ENVIRONMENTAL SCIENCES↗

A method to measure the thermovoltage with a high spatial resolution

We have recorded spatial maps of the thermovoltage of a Au(111) surface with a scanning tunneling microscope. The method relies on an approach where we record quasi-simultaneously the normal topography as well as the thermovoltage by switching the feedback and sample bias on and off. This setup can be combined with standard scanning tunneling microscopy and scanning tunneling spectroscopy techniques. The thermovoltage, which arises from a temperature difference between scanning tunneling microscope tip and sample, is very sensitive to small variations of the local electronic density of states in vicinity of the Fermi level. Near step edges we have observed well-defined Friedel oscillations, while for the herringbone reconstruction, small variations of the local work-function are measured. By altering the tip-sample distance, the thermovoltage contrast can be adjusted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial Resolution Versus Data Acquisition Efficiency in Mapping an Inhomogeneous System with Species Diffusion

Traditionally, spatially-resolved photoluminescence (PL) has been performed using a point-by-point scan mode with both excitation and detection occurring at the same spatial location. But with the availability of high quality detector arrays like CCDs, an imaging mode has become popular for performing spatially-resolved PL. By illuminating the entire area of interest and collecting the data simultaneously from all spatial locations, the measurement efficiency can be greatly improved. However, this new approach has proceeded under the implicit assumption of comparable spatial resolution. We show here that when carrier diffusion is present, the spatial resolution can actually differ substantially between the two modes, with the less efficient scan mode being far superior. We apply both techniques in investigation of defects in a GaAs epilayer – where isolated singlet and doublet dislocations can be identified. A superposition principle is developed for solving the diffusion equation to extract the intrinsic carrier diffusion length, which can be applied to a system with arbitrarily distributed defects. The understanding derived from this work is significant for a broad range of problems in physics and beyond (for instance biology) – whenever the dynamics of generation, diffusion, and annihilation of species can be probed with either measurement mode.

14 SOLAR ENERGY↗

COMPLEX ORGANIC MOLECULES AT HIGH SPATIAL RESOLUTION TOWARD ORION-KL. II. KINEMATICS

It has recently been suggested that chemical processing can shape the spatial distributions of complex molecules in the Orion-KL region and leads to the nitrogen-oxygen 'chemical differentiation' seen in previous observations of this source. Orion-KL is a very dynamic region, and it is therefore also possible that physical conditions can shape the molecular distributions in this source. Only high spatial resolution observations can provide the information needed to disentangle these effects. Here, we present millimeter imaging studies of Orion-KL at various beam sizes using the Combined Array for Research in Millimeter-wave Astronomy. We compare molecular images with high spatial resolution images that trace the temperature, density, and kinematics of the source in order to investigate the effects of physical conditions on molecular distributions. These observations were conducted at {lambda} = 3 mm and included transitions of ethyl cyanide [C{sub 2}H{sub 5}CN], methyl formate [HCOOCH{sub 3}], formic acid [HCOOH], acetone [(CH{sub 3}){sub 2}CO], SiO, and methanol [CH{sub 3}OH]. We find differences in the molecular distributions as a function of each of the aforementioned physical factors. These results indicate that acetone may be produced by chemical processing and is robust to large changes in physical conditions, while formic acid is readily destroyed by gas-phase processing in warm and dense regions. We also find that while the spatial distributions of ethyl cyanide and methyl formate are not distinct as is suggested by the concept of 'chemical differentiation', local physical conditions shape the small-scale emission structure for these species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral Narrowing Accompanies Enhanced Spatial Resolution in Saturated Coherent Anti-Stokes Raman Scattering (CARS): Comparisons of Experiment and Theory

Here, we demonstrate theoretically and confirm experimentally the mechanism by which spectral narrowing accompanies enhanced spatial resolution in a saturated coherent anti-Stokes Raman scattering (CARS) signal that is demodulated at the third harmonic (3$f$) of the pump modulation frequency ($f$). Under these modulation conditions, theory predicts a narrowing of the full-width at half-maximum (FWHM) of the CARS spectrum by a factor of 2.0 with respect to that of the spectrum obtained by demodulation at the fundamental frequency. Theory also predicts an improvement of spatial resolution by a factor of 1.7. Experimentally, narrowing of the FWHM of the CARS spectrum of 1,4-bis((E)-2-methylstyryl) benzene (MSB) crystals by a factor of 2.5 is observed upon saturation. Further experimental confirmation is provided from investigating diamond particles, for which spectral narrowing was enhanced by a factor of 2.8 and spatial resolution was enhanced by a factor of 2. Details of the mechanism and execution of the saturated CARS experiment are elucidated and limits to its applicability are suggested, one of which is the conclusion that the saturation approach is not suitable for extraction of harmonics beyond 3$f$ . In this work we have developed a more comprehensive understanding of the correlation between the observed experimental results and experimental factors than has been previously reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WHY IS NON-THERMAL LINE BROADENING OF SPECTRAL LINES IN THE LOWER TRANSITION REGION OF THE SUN INDEPENDENT OF SPATIAL RESOLUTION?

Spectral observations of the solar transition region (TR) and corona show broadening of spectral lines beyond what is expected from thermal and instrumental broadening. The remaining non-thermal broadening is significant (5–30 km s{sup −1}) and correlated with intensity. Here we study spectra of the TR Si iv 1403 Å line obtained at high resolution with the Interface Region Imaging Spectrograph (IRIS). We find that the large improvement in spatial resolution (0.″33) of IRIS compared to previous spectrographs (2″) does not resolve the non-thermal line broadening which, in most regions, remains at pre-IRIS levels of about 20 km s{sup −1}. This invariance to spatial resolution indicates that the processes behind the broadening occur along the line-of-sight (LOS) and/or on spatial scales (perpendicular to the LOS) smaller than 250 km. Both effects appear to play a role. Comparison with IRIS chromospheric observations shows that, in regions where the LOS is more parallel to the field, magneto-acoustic shocks driven from below impact the TR and can lead to significant non-thermal line broadening. This scenario is supported by MHD simulations. While these do not show enough non-thermal line broadening, they do reproduce the long-known puzzling correlation between non-thermal line broadening and intensity. This correlation is caused by the shocks, but only if non-equilibrium ionization is taken into account. In regions where the LOS is more perpendicular to the field, the prevalence of small-scale twist is likely to play a significant role in explaining the invariance and correlation with intensity. (letters)

79 ASTRONOMY AND ASTROPHYSICS↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗