Modal characterization of the ASCIE segmented optics testbed: New algorithms and experimental results

New frequency response measurement procedures, on-line modal tuning techniques, and off-line modal identification algorithms are developed and applied to the modal identification of the Advanced Structures/Controls Integrated Experiment (ASCIE), a generic segmented optics telescope test-bed representative of future complex space structures. The frequency response measurement procedure uses all the actuators simultaneously to excite the structure and all the sensors to measure the structural response so that all the transfer functions are measured simultaneously. Structural responses to sinusoidal excitations are measured and analyzed to calculate spectral responses. The spectral responses in turn are analyzed as the spectral data become available and, which is new, the results are used to maintain high quality measurements. Data acquisition, processing, and checking procedures are fully automated. As the acquisition of the frequency response progresses, an on-line algorithm keeps track of the actuator force distribution that maximizes the structural response to automatically tune to a structural mode when approaching a resonant frequency. This tuning is insensitive to delays, ill-conditioning, and nonproportional damping. Experimental results show that is useful for modal surveys even in high modal density regions. For thorough modeling, a constructive procedure is proposed to identify the dynamics of a complex system from its frequency response with the minimization of a least-squares cost function as a desirable objective. This procedure relies on off-line modal separation algorithms to extract modal information and on least-squares parameter subset optimization to combine the modal results and globally fit the modal parameters to the measured data. The modal separation algorithms resolved modal density of 5 modes/Hz in the ASCIE experiment. They promise to be useful in many challenging applications.

Carrier, Alain C.↗

Tuning and tailoring of broadband quantum-well infrared photodetector responsivity spectrum.

The spectral response of quantum-well infrared photodetectors (QWIPs) based on the III-V material system are tailorable to narrow or broad bandwidths within mid- and long-wavelength infrared bands. Typical broad-band QWIPs show considerable spectral shape change with bias voltage, particularly near the cut-off wavelength region. Two alternatives to the typical broadband QWIP design have been demonstrated. These designs consist of two multiquantum-well (QW) stacks or alternatively placed QWs and produce nearly fixed spectrums within the operating bias voltages. Flexibility in many design parameters of these detectors allows for tuning and tailoring the spectral shape according to application requirements, specifically for spectral imaging instruments

Liu, A. W. K.↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

Deconvolution of SNPP VIIRS Solar Diffuser Bidirectional Reflectance Distribution Function On-orbit Change Factor

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly calibrates its reflective solar bands (RSBs), primarily through observing an onboard sunlit solar diffuser (SD). The on-orbit change of the value of the SD bidirectional reflectance distribution function (BRDF) is quantified by a numerical factor, called the H-factor, and is determined by the onboard SD stability monitor (SDSM). Because the spectral response function of an SDSM detector spreads in wavelength, the directly measured H-factor is the true H-factor convolved with the spectral response function. To find the true H-factor, we use the traditional direct method and an innovative iterative approach to separately deconvolve the measured H-factor. Our iterative approach relies on two properties of the SDSM detector spectral response function: the central peak width is narrow enough so that the H-factor does not change much over the peak width, and the dominance of the spectral response function’s integral with respect to the wavelength over the width. The iterative approach is more accurate, of a smaller noise impact, much more flexible in terms of interpolation and extrapolation of function values, and faster. We have used deconvolved H-factors to calibrate the NASA SNPP VIIRS RSB Collections 1 and 2 Level-1B products.

SNPP VIIRS↗

Multispectral scanner flight model (F-1) radiometric calibration and alignment handbook

This handbook on the calibration of the MSS-D flight model (F-1) provides both the relevant data and a summary description of how the data were obtained for the system radiometric calibration, system relative spectral response, and the filter response characteristics for all 24 channels of the four band MSS-D F-1 scanner. The calibration test procedure and resulting test data required to establish the reference light levels of the MSS-D internal calibration system are discussed. The final set of data ("nominal" calibration wedges for all 24 channels) for the internal calibration system is given. The system relative spectral response measurements for all 24 channels of MSS-D F-1 are included. These data are the spectral response of the complete scanner, which are the composite of the spectral responses of the scan mirror primary and secondary telescope mirrors, fiber optics, optical filters, and detectors. Unit level test data on the measurements of the individual channel optical transmission filters are provided. Measured performance is compared to specification values.

Source record↗

Extension of laboratory-measured soil spectra to field conditions

Spectral responses of two glaciated soils, Chalmers silty clay loam and Fincastle silt loam, formed under prairie grass and forest vegetation, respectively, were measured in the laboratory under controlled moisture equilibria using an Exotech Model 20C spectroradiometer to obtain spectral data in the laboratory under artificial illumination. The same spectroradiometer was used outdoors under solar illumination to obtain spectral response from dry and moistened field plots with and without corn residue cover, representing the two different soils. Results indicate that laboratory-measured spectra of moist soil are directly proportional to the spectral response of that same field-measured moist bare soil over the 0.52 micrometer to 1.75 micrometer wavelength range. The magnitudes of difference in spectral response between identically treated Chalmers and Fincastle soils are greatest in the 0.6 micrometers to 0.8 micrometer transition region between the visible and near infrared, regardless of field condition or laboratory preparation studied.

Stoner, E. R.↗

Spectral behavior of wheat yield variety trials

Little variation between varieties is seen at jointing, but the variability is found to increase during grain filling and decline again at maturity. No relationship is found between spectral response and yield, and when yields are segregated into various classes the spectral response is the same. Spring and winter nurseries are found to separate during the reproductive stage because of differences in dates of heading and maturity, but they exhibit similar spectral responses. The transformed normalized difference is at a minimum after the maximum grain weight occurs and the leaves begin to brown and fall off. These data of 100% ground cover demonstrate that it is not possible to predict grain yield from only spectral data. This, however, may not apply when reduced yields are caused by less-than-full ground cover

Hatfield, J. L.↗

Twenty Years of Terra MODIS Spectral Performance using the Spectro-Radiometric Calibration Assembly

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument on-board the Terra spacecraft has provided valuable Earth data to the science community for the last 20 years. Equipped with several on-board calibrators (OBCs), MODIS has continued to operate nominally since its launch in December 1999. The Spectro-Radiometric Calibration Assembly (SRCA) is one such OBC that is able to provide on-orbit measurements of the MODIS reflective solar bands (RSBs) in radiometric, spatial and spectral modes. While the SRCA is operating in spectral mode, it is able to monitor the center wavelength (CW), bandwidth (BW) and in-band relative spectral response (RSR) of most RSBs. Prelaunch measurements of the CWs, BWs and RSRs of the RSBs were performed at the system level using the Spectral measurement Assembly (SpMA). Using both the prelaunch measurements and the measurements obtained on-orbit using the SRCA, the changes in the spectral response of the MODIS reflective bands can be monitored throughout the mission. This paper will provide a brief description of the spectral calibration approach and report on-orbit changes in these spectral performance parameters and their uncertainties over the last 20 years. It will also address changes to the SRCA operation on-orbit and their impact on measured spectral calibration results. Despite two decades in orbit, the spectral responses for most Terra MODIS reflective bands continue to remain within their design specifications.

MODIS↗

Comparison of Two Methodologies for Calibrating Satellite Instruments in the Visible and Near Infrared

Traditionally, satellite instruments that measure Earth-reflected solar radiation in the visible and near infrared wavelength regions have been calibrated for radiance response in a two-step method. In the first step, the spectral response of the instrument is determined using a nearly monochromatic light source, such a lamp-illuminated monochromator. Such sources only provide a relative spectral response (RSR) for the instrument, since they do not act as calibrated sources of light nor do they typically fill the field-of-view of the instrument. In the second step, the instrument views a calibrated source of broadband light, such as lamp-illuminated integrating sphere. In the traditional method, the RSR and the sphere spectral radiance are combined and, with the instrument's response, determine the absolute spectral radiance responsivity of the instrument. More recently, an absolute calibration system using widely tunable monochromatic laser systems has been developed, Using these sources, the absolute spectral responsivity (ASR) of an instrument can be determined on a wavelength-hy-wavelength basis. From these monochromatic ASRs. the responses of the instrument bands to broadband radiance sources can be calculated directly, eliminating the need for calibrated broadband light sources such as integrating spheres. Here we describe the laser-based calibration and the traditional broad-band source-based calibration of the NPP VIIRS sensor, and compare the derived calibration coefficients for the instrument. Finally, we evaluate the impact of the new calibration approach on the on-orbit performance of the sensor.

Barnes, Robert A.↗

Spectral Characterizations of the Clouds and the Earth's Radiant Energy System (CERES) Thermistor Bolometers using Fourier Transform Spectrometer (FTS) Techniques

Fourier Transform Spectrometer (FTS) techniques are being used to characterize the relative spectral response, or sensitivity, of scanning thermistor bolometers in the infrared (IR) region (2 - >= 100-micrometers). The bolometers are being used in the Clouds and the Earth's Radiant Energy System (CERES) program. The CERES measurements are designed to provide precise, long term monitoring of the Earth's atmospheric radiation energy budget. The CERES instrument houses three bolometric radiometers, a total wavelength (0.3- >= 150-micrometers) sensor, a shortwave (0.3-5-micrometers) sensor, and an atmospheric window (8-12-micrometers) sensor. Accurate spectral characterization is necessary for determining filtered radiances for longwave radiometric calibrations. The CERES bolometers spectral response's are measured in the TRW FTS Vacuum Chamber Facility (FTS - VCF), which uses a FTS as the source and a cavity pyroelectric trap detector as the reference. The CERES bolometers and the cavity detector are contained in a vacuum chamber, while the FTS source is housed in a GN2 purged chamber. Due to the thermal time constant of the CERES bolometers, the FTS must be operated in a step mode. Data are acquired in 6 IR spectral bands covering the entire longwave IR region. In this paper, the TRW spectral calibration facility design and data measurement techniques are described. Two approaches are presented which convert the total channel FTS data into the final CERES spectral characterizations, producing the same calibration coefficients (within 0.1 percent). The resulting spectral response curves are shown, along with error sources in the two procedures. Finally, the impact of each spectral response curve on CERES data validation will be examined through analysis of filtered radiance values from various typical scene types.

Thornhill, K. Lee↗

Landsat 9 Thermal Infrared Sensor 2 Subsystem-Level Spectral Test Results

Results from the Thermal Infrared Sensor 2 (TIRS-2) prelaunch spectral characterization at telescope and detector subsystem level are presented. The derived relative spectral response (RSR) shape is expected to be very similar to the instrument-level spectral response and provides an initial estimate of the RSR and its differences to the component-level RSR measurements. Such differences were observed at TIRS- 1 and are likely a result of angular dependence of the spectral response of the detector. The subsystem RSR measurements also provide an opportunity for a preliminary assessment of the spectral requirements. Final requirements verification will be performed at future thermal vacuum environmental testing with the fully assembled TIRS-2 instrument.

TIRS-2↗

An analysis of the effect of biological and physical parameters of a wetlands grass biome on the spectral modeling of phytomass and primary productivity

Aircraft simulated thematic mapper data and field data were acquired in the fall and spring to analyze the relationship of spectral response and biomass for the marsh grass Spartina patens. Regression results indicate no simple relationship exists for TMS spectral response and biomass with a high R sq. However, results show a consistent relationship between spectral response and the percent live vegetation (by weight) and percent interstitial standing surface water (by area) as independent variables. It is suggested that the reflected energy of a pixel represents a mixture of surface constituents. It is recommended that alternative remote sensors be employed to account for the pixel constituents of live and dead vegetation, litter, and standing water.

Butera, M. K.↗

Excimer laser processing of backside-illuminated CCDS

An excimer laser is used to activate previously implanted dopants on the backside of a backside-illuminated CCD. The controlled ion implantation of the backside and subsequent thin layer heating and recrystallization by the short wavelength pulsed excimer laser simultaneously activates the dopant and anneals out implant damage. This improves the dark current response, repairs defective pixels and improves spectral response. This process heats a very thin layer of the material to high temperatures on a nanosecond time scale while the bulk of the delicate CCD substrate remains at low temperature. Excimer laser processing backside-illuminated CCD's enables salvage and utilization of otherwise nonfunctional components by bringing their dark current response to within an acceptable range. This process is particularly useful for solid state imaging detectors used in commercial, scientific and government applications requiring a wide spectral response and low light level detection.

Russell, S. D.↗

Recent Development of Sb-based Phototransistors in the 0.9- to 2.2-microns Wavelength Range for Applications to Laser Remote Sensing

We have investigated commercially available photodiodes and also recent developed Sb-based phototransistors in order to compare their performances for applications to laser remote sensing. A custom-designed phototransistor in the 0.9- to 2.2-microns wavelength range has been developed at AstroPower and characterized at NASA Langley's Detector Characterization Laboratory. The phototransistor's performance greatly exceeds the previously reported results at this wavelength range in the literature. The detector testing included spectral response, dark current and noise measurements. Spectral response measurements were carried out to determine the responsivity at 2-microns wavelength at different bias voltages with fixed temperature; and different temperatures with fixed bias voltage. Current versus voltage characteristics were also recorded at different temperatures. Results show high responsivity of 2650 A/W corresponding to an internal gain of three orders of magnitude, and high detectivity (D*) of 3.9x10(exp 11) cm.Hz(exp 1/2)/W that is equivalent to a noise-equivalent-power of 4.6x10(exp -14) W/Hz(exp 1/2) (-4.0 V @ -20 C) with a light collecting area diameter of 200-microns. It appears that this recently developed 2-micron phototransistor's performances such as responsivity, detectivity, and gain are improved significantly as compared to the previously published APD and SAM APD using similar materials. These detectors are considered as phototransistors based-on their structures and performance characteristics and may have great potential for high sensitivity differential absorption lidar (DIAL) measurements of carbon dioxide and water vapor at 2.05-microns and 1.9-microns, respectively.

Abedin, M. Nurul↗

Interaction of Sound from Supersonic Jets with Nearby Structures

A model of sound generated in an ideally expanded supersonic (Mach 2) jet is solved numerically. Two configurations are considered: (1) a free jet and (2) an installed jet with a nearby array of flexible aircraft type panels. In the later case the panels vibrate in response to loading by sound from the jet and the full coupling between the panels and the jet is considered, accounting for panel response and radiation. The long time behavior of the jet is considered. Results for near field and far field disturbance, the far field pressure and the vibration of and radiation from the panels are presented. Panel response crucially depends on the location of the panels. Panels located upstream of the Mach cone are subject to a low level, nearly continuous spectral excitation and consequently exhibit a low level, relatively continuous spectral response. In contrast, panels located within the Mach cone are subject to a significant loading due to the intense Mach wave radiation of sound and exhibit a large, relatively peaked spectral response centered around the peak frequency of sound radiation. The panels radiate in a similar fashion to the sound in the jet, in particular exhibiting a relatively peaked spectral response at approximately the Mach angle from the bounding wall.

Fenno, C. C., Jr.↗

Computed lateral power spectral density response of conventional and STOL airplanes to random atmospheric turbulence

A method of computing the power spectral densities of the lateral response of airplanes to random atmospheric turbulence was adapted to an electronic digital computer. By use of this program, the power spectral densities of the lateral roll, yaw, and sideslip angular displacement of several conventional and STOL airplanes were computed. The results show that for the conventional airplanes, the roll response is more prominent than that for yaw or sideslip response. For the STOL airplanes, on the other hand, the yaw and sideslip responses were larger than the roll response. The response frequency of the STOL airplanes generally is higher than that for the conventional airplanes. This combination of greater sensitivity of the STOL airplanes in yaw and sideslip and the frequency at which they occur could be a factor causing the poor riding qualities of this class of airplanes.

Lichtenstein, J. H.↗

An improved spectral calibration requirement for AVIRIS

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectra from 400 to 2500 nm through 224 contiguous spectral channels. These spectra are used to identify and determine the abundances of constituents of the earth's surface and atmosphere through the analysis of spectral molecular absorptions and scattering properties of materials. Spectral calibration of the AVIRIS is required to pursue these determinations, which are based on these fundamental spectral characteristics. The spectral calibration of AVIRIS consists of a description of the spectral response function for each of the 224 spectral channels. The spectral response function of AVIRIS channels was measured in the laboratory and shown to be Gaussian in shape. A subset of nine AVIRIS spectral channels is shown with channel centers at 10 nm intervals and channel shapes of Gaussian form with 10 nm full width and half maximum (FWHM). For AVIRIS the spectral calibration is described by the spectral center and FWHM of a Gaussian function for each channel. Uncertainty in the determination of the spectral center and FWHM for each channel are also reported. This paper presents results from an investigation of the sensitivity of AVIRIS-measured upwelling radiance to errors in spectral calibration. Based on this sensitivity analysis in conjunction with earlier work, an improved spectral calibration requirement for AVIRIS is proposed.

Green, Robert O.↗

Characterization and Analysis of InGaAsSb Detectors

Profiling of atmospheric CO2 at 2 micron wavelength using the LIDAR technique, has recently gained interest. Although several detectors might be suitable for this application, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the detector signal-to-noise ratio and minimizes the background signal, thereby increasing the device sensitivity and dynamic range. Detectors meeting the above idealized criteria are commercially unavailable for this particular wavelength. In this paper, the characterization and analysis of Sb-based detectors for 2 micron lidar applications are presented. The detectors were manufactured by AstroPower, Inc., with an InGaAsSb absorbing layer and AlGaAsSb passivating layer. The characterization experiments included spectral response, current versus voltage and noise measurements. The effect of the detectors bias voltage and temperature on its performance, have been investigated as well. The detectors peak responsivity is located at the 2 micron wavelength. Comparing three detector samples, an optimization of the spectral response around the 2 micron wavelength, through a narrower spectral period was observed. Increasing the detector bias voltage enhances the device gain at the narrow spectral range, while cooling the device reduces the cut-off wavelength and lowers its noise. Noise-equivalent-power analysis results in a value as low as 4 x 10(exp -12) W/Hz(exp 1/2) corresponding to D* of 1 x 10(exp 10) cmHz(exp 1/2)/W, at -1 V and 20 C. Discussions also include device operational physics and optimization guidelines, taking into account peculiarity of the Type II heterointerface and transport mechanisms under these conditions.

Abedin, M. Nurul↗