Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Evaluation of normalization strategies for mass spectrometry-based multi-omics datasets

Introduction Data normalization is crucial for multi-omics integration, reducing systematic errors and maximizing the likelihood of discovering true biological variation. Most studies assess normalization for a single omics type or use datasets from separate experiments. Few address time-course data, where normalization might bias temporal differentiation. In this study, we compared common normalization methods and a machine learning approach, Systematical Error Removal using Random Forest (SERRF), using multi-omics datasets generated from the same experiment—even from the same cell lysate. Objectives To develop a straightforward process to assess normalization effects and identify the most robust methods across multi-omics datasets. Methods We analyzed metabolomics, lipidomics, and proteomics datasets from primary human cardiomyocytes and motor neurons exposed to acetylcholine-active compounds over time. Normalization effectiveness was evaluated based on improvement in QC features consistency and observing the change in treatment and time-related variance. Results Probabilistic Quotient Normalization (PQN) and Locally Estimated Scatterplot Smoothing (LOESS) QC were identified as optimal for metabolomics and lipidomics, while PQN, Median, and LOESS normalization excelled for proteomics. These methods consistently enhanced QC feature consistency in metabolomics and lipidomics, and preserved time-related variance or treatment-related variance in proteomics, demonstrating their effectiveness and robustness. SERRF normalization, applied only to metabolomics in this study, outperformed other methods in some datasets but inadvertently masked treatment-related variance in others. Conclusion Our evaluation identified PQN and LoessQC as the top methods for metabolomics and lipidomics, and PQN, Median, and Loess normalization for proteomics, in multi-omics integration in a temporal study.

60 APPLIED LIFE SCIENCES↗

The Power of Many: An Ensemble Approach to Spectral Similarity

Quantifying the similarity between two mass spectra─a known reference mass spectrum and an unidentified sample mass spectrum─is at the heart of compound identification workflows in gas chromatography–mass spectrometry (GC-MS). The reference spectrum most like the sample is assigned as its identification (provided some quantitative similarity threshold is met, e.g., 80%) and thus accurately measuring similarity is essential. Significant research has gone toward developing metrics for this purpose, each of which has attempted to improve upon existing methods by incorporating GC-MS-specific information (e.g., peak ratios or retention times) or adopting various statistical and algorithmic frameworks. While this active development has led to a plethora of similarity metrics with demonstrated value across different contexts, the unfortunate consequence has been confusion surrounding which metric should be used as a global standard. No such metric is currently accepted as the standard method because different metrics have demonstrated optimal performance in different contexts. In this work, we propose an ensemble approach to spectral similarity scoring that combines the collective information from across existing similarity metrics to form an improved, globally representative similarity metric as a step toward establishing a global standard method. In conclusion, the resulting ensemble metrics are evaluated on over 88,000 spectra of varying complexity and demonstrate improved abilities to accurately rank the correct reference spectrum as the top-matching candidate for a sample relative to the rankings generated by individual similarity scores.

Carbohydrates↗

Enhanced Optical Contrast and Switching in Near‐Infrared Electrochromic Devices by Optimizing Conjugated Polymer Oligo(Ethylene Glycol) Sidechain Content and Gel Electrolyte Composition

Abstract A detailed investigation addressing the effects of functionalizing conjugated polymers with oligo(ethylene glycol) (EG n ) sidechains on the performance and polymer‐electrolyte compatibility of electrochromic devices (ECDs) is reported. The electrochemistry for a series of donor‐acceptor copolymers having near‐infrared (NIR)‐optical absorption, where the donor fragment is 3,4‐ethylenedioxythiophene (EDOT) or an EG n functionalized bithiophene (g2T) and the acceptor fragment is diketopyrrolopyrrole (DPP) functionalized with branched alkyl or EG n sidechains, is extensively probed. ECDs are next fabricated and it is found that EG n sidechain incorporation must be finely balanced to promote polymer‐electrolyte compatibility and provide efficient ion exchange. Proper electrolyte‐cation pairing and polymer structural tuning affords a 2x increase in optical contrast (from 12% to 24%) and >60x reduction in switching time (from 20 to 0.3 s). Atomic force microscopy (AFM)/grazing incidence wide‐angle X‐ray scattering (GIWAXS) characterization of the polymer film morphology/microstructure reveals that an over‐abundance of EG n sidechains generates large polymer crystallites, which can suppress ion exchange. Lastly, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) indicates sidechain/electrolyte identity does not influence the electrolyte penetration depth into the films, and EG n sidechain inclusion increases electrolyte cation uptake. The material structural design insight and guidelines regarding the polymer‐electrolyte ion insertion/expulsion dynamics reported here should be of significant utility for developing next‐generation mixed ionic‐electronic conducting materials.

Chemistry↗

Hepatocellular Metabolic Profile: Understanding Post-Thawing Metabolic Shift in Primary Hepatocytes In Vitro

Primary human hepatocytes (PHHs) are widely used as in vitro models for liver function and drug metabolism studies, yet their metabolic stability post-thawing remains an open question. To better characterize early metabolic changes, we conducted a time-course experiment using liquid chromatography-tandem mass spectrometry (LC-MS/MS) to analyze metabolic shifts in PHHs cultured in suspension. Unexposed and exposed (acetaminophen-treated) samples were evaluated, and TITAN analysis was applied to determine the time point of maximal metabolic change at both individual metabolite and global metabolic profile levels. Our results indicate that the majority of metabolic shifts occur within the first five hours post-thawing. In the early culture time points, substantial metabolic overlap was observed between unexposed and exposed cells, suggesting a conserved biological response likely related to cellular recovery. However, at later time points, metabolite profiles diverged, with acetaminophen treatment-specific metabolic changes emerging, potentially reflecting differences in homeostatic restoration versus hepatotoxic responses. Our study highlights the importance of considering early post-thawing metabolic dynamics in experimental design and offers insights for optimizing hepatocyte culture protocols to better replicate in vivo physiological conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the relationship between deposition method, microstructure, and performance of Nb/Si-based superconducting coplanar waveguide resonators

Superconducting quantum circuits (SQC) are one of the most promising hardware platforms for quantum computing, yet their performance is currently limited by the presence of various structural defects inside the circuit's structure. Despite impressive progress in the past decade, a precise understanding of the origin of these defects from various fabrication processes and their impact on coherence is still lacking. Here, in this study, we performed a comprehensive investigation on the microstructure, superconductivity, and resonator quality factor of Nb films deposited by high-power impulse magnetron sputtering (HiPIMS) and direct current (DC) magnetron sputtering. A suite of characterization techniques, including electron microscopy with spectroscopy, secondary ion mass spectrometry, magneto-optical microscopy, and pump-probe reflectivity spectroscopy is used. We reveal that niobium (Nb) resonators fabricated using HiPIMS exhibit a smaller average grain size, thicker surface oxide with larger thickness variations (rougher surface), and a thicker amorphous Nb/Si interface layer compared to samples deposited by DC sputtering. We identified that the amorphous Nb oxides (mainly located at the Nb surface and along the grain boundaries) and Nb-Si amorphous layers (at the Nb/Si interface) are major and potential sources of two-level system (TLS), while off-stochiometric oxides and suboxides of Nb close to the surface, crystalline defects (i.e., dislocations at grain boundary, point defects introduced during deposition) are main contributors of non-TLS sources. Our findings clarify the relationship between different defects and coherence loss mechanisms, highlighting the importance of material microstructure control on performance optimization in SQC.

36 MATERIALS SCIENCE↗

Transformation of TiN to TiNO Films via In-Situ Temperature-Dependent Oxygen Diffusion Process and Their Electrochemical Behavior

Titanium oxynitride (TiNO) thin films represent a multifaceted material system applicable in diverse fields, including energy storage, solar cells, sensors, protective coatings, and electrocatalysis. This study reports the synthesis of TiNO thin films grown at different substrate temperatures using pulsed laser deposition. A comprehensive structural investigation was conducted by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Non-Rutherford backscattering spectrometry (N-RBS), and X-ray absorption spectroscopy (XAS), which facilitated a detailed analysis that determined the phase, composition, and crystallinity of the films. Structural control was achieved via temperature-dependent oxygen in-diffusion, nitrogen out-diffusion, and the nucleation growth process related to adatom mobility. The XPS analysis indicates that the TiNO films consist of heterogeneous mixtures of TiN, TiNO, and TiO2 phases with temperature-dependent relative abundances. The correlation between the structure and electrochemical behavior of the thin films was examined. The TiNO films with relatively higher N/O ratio, meaning less oxidized, were more electrochemically active than the films with lower N/O ratio, i.e., more oxidized films. Films with higher oxidation levels demonstrated enhanced crystallinity and greater stability under electrochemical polarization. These findings demonstrate the importance of substrate temperature control in tailoring the properties of TiNO film, which is a fundamental part of designing and optimizing an efficient electrode material.

Cherono, Sheilah↗

Online Monitoring of Catalytic Processes by Fiber-Enhanced Raman Spectroscopy

An innovative solution for real-time monitoring of reactions within confined spaces, optimized for Raman spectroscopy applications, is presented. This approach involves the utilization of a hollow-core waveguide configured as a compact flow cell, serving both as a conduit for Raman excitation and scattering and seamlessly integrating into the effluent stream of a cracking catalytic reactor. The analytical technique, encompassing device and optical design, ensures robustness, compactness, and cost-effectiveness for implementation into process facilities. Notably, the modularity of the approach empowers customization for diverse gas monitoring needs, as it readily adapts to the specific requirements of various sensing scenarios. As a proof of concept, the efficacy of a spectroscopic approach is shown by monitoring two catalytic processes: CO 2 methanation (CO 2 + 4H 2 → CH 4 + 2H 2 O) and ammonia cracking (2NH 3 → N 2 + 3H 2 ). Leveraging chemometric data processing techniques, spectral signatures of the individual components involved in these reactions are effectively disentangled and the results are compared to mass spectrometry data. This robust methodology underscores the versatility and reliability of this monitoring system in complex chemical environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Boosting the Oxygen Evolution Reaction by Tuning the Interfacial Iron Adsorption on Layered Double Hydroxide

Understanding the interaction between ions in the electrolyte and electrode materials plays an important role in optimizing the water electrolysis performance for hydrogen production. Herein, the synergistic effect of iron (Fe) in the electrolyte and interlayer anions within the layered structure on the oxygen evolution reaction (OER) has been investigated by combining material synthesis with controlled structure, multiple characterization techniques, and first-principles calculations. Nickel aluminum layered double hydroxides (NiAl-LDHs) with different interlayer anions (CO 3 2– , Cl – , and Br – ) show similar oxygen evolution activity in the absence of Fe species in the electrolyte. The addition of Fe into the electrolyte results in improved performance for all of the NiAl-LDHs, following the rank LDH-Br > LDH-Cl > LDH-CO 3 , under all of the conditions with varied concentration of Fe. X-ray absorption spectroscopy and identical location electron microscopy analyses show that the LDH structure remains unchanged after the OER activity test, while in situ stationary probe rotating disk electrode inductively coupled plasma mass spectrometry (SPRDE-ICP-MS) measurements show partial dissolution of the intercalating halide ions during cycling, with less dissolution for Br-intercalated materials. Insights from theoretical calculations demonstrate the thermodynamic preference of Br – to remain intercalated in the presence of Fe, while the stronger adsorption of Fe(OH) 3 species on the LDH-Br sample promotes the OER activity. In conclusion, these results provide mechanistic insights into the rational design of active layered materials with an enhanced OER performance for efficient water electrolysis.

58 GEOSCIENCES↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth and structure of alpha-Ta films for quantum circuit integration

Tantalum films incorporated into superconducting circuits have exhibited low surface losses, resulting in long-lived qubit states. The remaining loss pathways originate in microscopic defects that manifest as two level systems (TLSs) at low temperatures. These defects limit performance, so careful attention to tantalum film structures is critical for optimal use in quantum devices. In this work, we investigate the growth of tantalum using magnetron sputtering on sapphire, Si, and photoresist substrates. In the case of sapphire, we present procedures for the growth of fully-oriented films with α-Ta [1 1 1]//Al2O3 [0 0 0 1] and α-Ta [1 −1 0]//Al2O3 [1 0 −1 0] orientational relationships and having residual resistivity ratio (RRR) ∼ 60 for 220 nm thick films. On Si, we find a complex grain texturing with Ta [1 1 0] normal to the substrate and RRR ∼ 30. We further demonstrate airbridge fabrication using Nb to nucleate α-Ta on photoresist surfaces. For the films on sapphire, resonators show TLS-limited quality factors of 1.3 ± 0.3 × 106 at 10 mK (for a waveguide gap and conductor width of 3 and 6 μm, respectively). Structural characterization using scanning electron microscopy, x-ray diffraction, low temperature transport, secondary ion mass spectrometry, and transmission electron microscopy reveal the dependence of residual impurities and screw dislocation density on processing conditions. The results provide practical insights into the fabrication of advanced superconducting devices including qubit arrays and guide future works on crystallographically deterministic qubit fabrication.

42 ENGINEERING↗

Composition, Activity, and Stability of IrO x Oxygen Evolution Reaction Electrocatalysts

The oxygen evolution reaction (OER) is integral to several electrochemical energy conversion and storage technologies, including carbon dioxide reduction to value added fuels, nitrogen reduction to ammonia, reversible fuel cells, rechargeable metal−air batteries, and water electrolysis to produce hydrogen. Iridium oxide (IrO x ) is widely recognized as the benchmark OER catalyst for acidic environments. Despite widespread use of IrO x catalysts, most notably in proton-exchange membrane water electrolyzers (PEMWEs), a comprehensive understanding of the physicochemical properties of commercial catalysts and the impact of these properties on both the activity and stability of these catalysts is lacking. Here, we study commercial IrO x catalysts with different physicochemical properties, three nominally considered amorphous and three rutile, to elucidate how structural and compositional variations affect OER activity and stability. Utilizing standardized aqueous electrochemical protocols, time-resolved dissolution quantification using inductively-coupled plasma mass spectrometry, and physicochemical characterization, including multiple synchrotron X-ray techniques, we systematically correlate catalyst properties with OER performance and degradation behavior aided by principal component analysis (PCA). Our results demonstrate the general trend of amorphous IrO x having higher intrinsic activity but limited stability and crystalline rutile IrO 2 having lower activity but enhanced stability against dissolution. The trends within the amorphous and rutile catalyst groups correlate with inherent material properties, including phase composition and structure, crystallinity, particle size, surface area, and surface structure/chemistry. Notably, we identify a rutile catalyst with the largest crystallite/ domain sizes, moderate surface area, a small fraction of hydrous phase, and a favorable pore structure (trimodal distributions of pore sizes ranging from 2−5 nm) that exhibits the best balance between activity and stability among the six catalysts studied here. These findings illustrate a fundamental structure-governed trade-off between activity and stability and highlight the critical role of surface chemistry modification and structure engineering in IrO x catalyst optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of n-Type Iodine-Doped and Indium-Doped CdTe/Cd-Se-Te Thin Films Fabricated by Close-Spaced Sublimation Epitaxy

In this study, n-type CdTe thin films, specifically iodine-doped CdTe (CdTe:I), indium-doped CdTe (CdTe:In), and indium-doped Cd-Se-Te (CST:In), were synthesized using close-spaced sublimation epitaxy (CSSE). Characterization techniques secondary ion mass spectrometry (SIMS), electron backscatter diffraction (EBSD), Hall-effect measurements, and time-resolved photoluminescence (TRPL) were employed to analyze the chemical, structural, and electronic properties of these materials. The results indicated epitaxial single crystal CSSE films grew on the single crystal substrates, with carrier density ranging from 10^14 - 10^16 cm -3 , and after post-annealing, the minority-carrier lifetimes reach near the radiative limit. Additionally, a preliminary exploration of homojunction structures with an n- type (CdTe:In /CST:In /CdTe:I) /CdTe:P /Cu /Mo configuration was performed. The best device performance was achieved with CdTe:I including CdS aiding in band alignment, resulting in a power conversion efficiency (..eta..) of 2.61% with open circuit voltage (Voc) of 850 mV, fill factor (FF) of 47.8%, and short-circuit current (Jsc) of 6.44 mA/cm 2 . The observed low Jsc and efficiency may be attributed to a buried junction and a poor interface, due to dopant interdiffusion. Consequently, further investigations focusing on interface optimization, diffusion blocking, and reduced recombination through passivation, are crucial to enhancing the efficiency of CSSE CdTe homojunction devices in the future.

cadmium compounds↗

Development and implementation of high-throughput proteomic and metabolomics assays by using advanced chromatographic and mass spectrometric systems (CRADA Final Report)

The mission of this CRADA with Agilent was to couple powerful MS platforms (QQQ, IM-QTOFMS) with Agilent’s novel Ultra-High-Performance Liquid Chromatography (UHPLC) fast metabolomic workflows and perform ABF Machine Learning (ML) to generated datasets. Agilent transferred UHPLC methods to PNNL and LBNL and methods were implemented and demonstrated in both labs, achieving total acquisition times of < 10 min. Metabolites analyzed using Agilent’s shared methods included metabolites from central carbon metabolism, common across hosts, and metabolites unique to engineered strains. Standards were acquired in an UHPLC-Drift Tube Ion Mobility Mass Spectrometer (DTIMS) system for the first time within the context of ABF and methods were optimized based on Agilent’s protocols. Samples from ABF hosts Pseudomonas putida, Aspergillus pseudoterreus, Aspergillus niger and Rhodosporidium toruloides were analyzed using the UHPLC-DTIMS platform for a total of 276 runs. A data analysis workflow compatible with the Experimental Data Depot (EDD) and completely shareable was developed for the acquired UHPLC-DTIMS data. Samples were analyzed using a Data Independent Acquisition Approach (DIA), which for most of the standards provided more transitions therefore increasing detection confidence. Using the data acquired by PNNL, LBNL, and Agilent’s specifications from previous ML projects, SNL applied an ensemble ML strategy to pick the best performing model for automated LC-method selection. Finally, with the contribution of the participant labs and Agilent, SNL developed an Automated Method Selection (AMS) software tool to predict the best liquid chromatography method for analysis of any new molecules of interest. Samples with novel pathways and new metabolite targets of interest are generated at a high pace in the ABF. Overall, the project advanced rapid metabolomics by combining liquid chromatography, ion mobility spectrometry, and data-independent mass spectrometry with machine learning. This multidimensional approach uses retention time, collision cross-section, precursor mass, and fragment-ion information to distinguish chemically similar metabolites that can be difficult to resolve using conventional liquid- or gas-chromatography methods. The resulting workflow also provided automated metabolite-identification error estimates, addressing a recognized need for statistical confidence measures in metabolomics.

Petzold, Christopher [Lawrence Berkeley National L↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

Pyrolysis of high-density polyethylene: Degradation behaviors, kinetics, and product characteristics

Pyrolysis is a promising technology for converting plastic waste into valuable raw materials while offering a potential solution to the global plastic pollution crisis. In this study, the thermal pyrolysis of high-density polyethylene (HDPE) is investigated in a drop tube reactor under nearly isothermal conditions. The impact of reaction temperature and gas/volatile residence time on carbon conversion and product distribution is examined across a range of 500–900°C and 3.6–32.2s, respectively. Non-condensable gas products detected by online mass spectrometry are H 2 , CH 4 , C 2 H 4 , C 2 H 6 , C 3 H 6 , and C 3 H 8 . At elevated temperatures and prolonged residence time, H 2 yield reaches as high as 8.6 wt% of the initial HDPE mass due to intensified cracking reactions of C 2 –C 3 hydrocarbons and long-chain aliphatic compounds. Consequently, pyrolysis tars consist mainly of polycyclic aromatic hydrocarbons (PAHs) with 5–7 rings, accompanied by visible coke deposition within the reactor. HDPE decomposition to volatiles is an endothermic process and it is complete at a temperature between 492°C and 525°C, depending on the heating rate employed, from non-isothermal thermogravimetric analysis and differential scanning calorimetry (TGA-DSC) measurements. The thermal degradation of HDPE pellets follows the two-dimensional nucleation growth model for conversion levels up to 0.8 with an apparent activation energy of 259–270 kJ/mol and a pre-exponential factor of 4.83 × 10 17 –1.37 × 10 19 min -1 , determined from various isoconversional methods such as Flynn-Wall-Ozawa (FWO), Kissinger-Akahira-Sunose (KAS), and Starink, along with Criado's master plots. Further, these findings provide valuable insights into optimizing process parameters and refining reactor design for pyrolysis, which can be integrated with gasification and reforming processes to enhance hydrogen production on a larger scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗