Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Static Proof Load Testing of the Sandia SWiFT 13m Blades

Pre-flown Vestas V-27 wind turbine blades will be used at the new Sandia SWiFT test facility near Lubbock,Texas. Proof load testing the blades in the flapwise direction was needed to verify the blades are still fit for service after 20 years offield operation. Testing was conducted in Building 252(A60)at the NWTC near Boulder,Colorado, between Oct 28(arrival of blades)to Dec 4,2015(completion of testing), under NREL subtasks WE141A50 and WE161A50. Single-point, quasi-static loads were applied to the blade at three independent load stations of 5.92 m, 8.69 m, and 11.62 m, using the facility gantry crane to apply the test load in the positive flapwise direction (low pressure surface in compression). Following the flapwise load cases, a single point load was applied at the 8.69 m station in the negative edgewise direction (leading edge in compression). No damage was observed due to the introduction of the proof loads. Several small pops were heard during testing on each blade, primarily during loading at the 8.69 m station. Compliance (deflection per load) varied less than 7% between all blades for all load cases. Table 3-1 summarizes the applied loads, deflections, and compliance for each blade for the flapwise test cases. Applied test loads are the raw load cell reading minus the total tare load (combined tare load of saddle and tare load for blade self weight). Deflection here is average deflection from both LE and TE string pot data.

17 WIND ENERGY↗

Evaluating Fracture Behavior of Bioinspired Alumina-YSZ Composites through Static and Dynamic Mechanical Testing

Ceramic materials are known for their high hardness and strength but are limited by low toughness and sudden failure. Inspired by the microstructure of dental enamel, which features undulating rods that promote crack deflection and energy absorption, architected specimens were designed and manufactured. A bespoke ball-on-ring (BoR) testing apparatus measured the static biaxial rupture strength of these bioinspired materials. Additionally, impact testing with spherical steel projectiles assessed their behavior under dynamic conditions. Monolithic alumina specimens were compared to architected alumina reinforced with yttria-stabilized zirconia (YSZ) rods produced via direct ink write 3D printing. BoR tests revealed that monolithic alumina had a Weibull modulus of 10.53 and a characteristic strength of 372.3 MPa, while the composite specimens showed a Weibull modulus of 5.46 and a characteristic strength of 213.3 MPa. Although the composite failed at lower stresses and projectile velocities, it exhibited notable crack deflection and fracture resistance, with cracks being effectively interrupted by the rod inclusions. The composite specimens also resulted in fewer and larger fragments upon impact. Finite element simulations confirmed the effectiveness of the rod structures in enhancing fracture resistance.

Bioinspired materials↗

Development of High Temperature (>700°C) molten Salt Pump Technology for Gen3 Solar Power Tower Systems

Generation 3 Concentrating Solar Power (CSP) Systems require thermal energy storage that can efficiently receive solar heat and deliver it to a working fluid at temperatures greater than 700°C. For liquid systems, the thermal transfer fluid must be phase stable over large temperature ranges. High temperature molten salts meet this criteria, but are difficult liquids to handle. The high heat and salt content can be very corrosive to several different materials that are wetted by the liquid salt. For power tower collectors, the molten salt must be pumped under high pressure to the top of the collector tower. These pumps have impellers and shafts as part of their rotating elements, and under load, require bearings to control shaft movement while rotating. These high temperature pumps require submerged bearings, and thus bearing materials that can withstand the temperature and molten salt contact over long periods of time. This is essential for keeping pump maintenance costs low, and downtime to a minimum. Long running bearing materials is an enabling technology for integrated liquid systems in Generation 3 CSP Systems. Keeping costs low and systems reliable are critical for the broad adoption of Gen 3 CSP Systems. Hayward Tyler, Inc (HTI) proposed development of journal bearing materials for use in vertical pumps designed for pumping high temperature molten salt on both the hot and cold sides of the solar power tower. To complete this objective, HTI utilized the testing capabilities of Oak Ridge National Laboratory (ORNL) and High Temperature System Design (HTSD). Materials would first be selected for static corrosion testing, then downselected for tribological testing. Successful tribologically tested materials would then be downselected for use in additional test regimes. Ten samples were selected for static corrosion testing. Three passed the static testing regime. Two of these materials were downselected for ball material in tribological testing against three metallic alloys: Sintered Y2O3 Partially Stabilized Zirconia YTZP and Silicon Nitride, Grade 147-31N. HTI also proposed collecting data from a thorough bearing test regime using a test rig designed and built as part of this project, and also a conceptual design for a high temperature molten salt vertical pump. HTI withdrew from the project prior to completion of this work and this report reflects only the work completed prior to withdrawal. The completed work produced two papers, one manuscript submitted for publication, and one paper published in the journal Solar Energy Materials and Solar Cells. The papers are: “Tribological behavior of ceramic-alloy bearing contacts in molten salt lubrication for concentrating solar power” and “Material Selection and Corrosion Studies Of Candidate Bearing Materials For Use In Molten Chloride Salt."

14 SOLAR ENERGY↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Offshore Wind Turbine Blade (85 to120meters ultra-long blade) static and fatigue test

Offshore blades are not just longer, they are wider, heavier and more flexible. These longer blades are a key component of larger wind turbines and for turbines to be more efficient in low wind speeds. These longer blades help reduce the LCOE further and make offshore wind even more competitive. As described earlier, it is essential for the blades to be fully tested to verify and validate the blade designs and manufacturing processes to ensure a reliable product is installed in the field. Through this project WTTC developed and procured new testing equipment required to test longer blades with larger deflections and higher loads. R&D’s BCDA system commissioned was the largest fatigue test exciter system in the world and set the bar for other blade testing facilities worldwide.

17 WIND ENERGY↗

Mechanical Characterization of Fe-Co-2V (Hiperco): Fatigue/Monotonic Testing Hardness Testing and Fractography

Fe-Co-2V is a popular metallic alloy used in electromagnetic applications. However, there is a lack of mechanical fatigue characterization of this alloy in the literature. In this work, Fe-Co-2V specimens with rectangular cross-sections were carefully prepared in accordance with standards. They were measured for surface roughness and then subjected to quasi-static monotonic testing, as well as fatigue testing at both 0.5 Hz and 1 Hz frequencies. Both Rockwell hardness and Vickers micro- hardness testing were performed. Additionally, scanning electron microscopy imaging of the fractured surfaces was done. The quasi-static testing revealed a flat yield region characteristic of Laders bands. Here, the fatigue results did not show significant differences or sensitivity to change in frequency, although the fatigue life was higher on average for the 0.5 Hz. However, the fatigue results differed from published work at 0.33 Hz. The fractography revealed purely brittle fracture, with clear chevron marks and fracture initiation always starting at the surface. Lastly, it was identified that the C, D, and F Rockwell hardness scales were appropriate for testing this material and that the grain size necessitated the use of the upper end of indentation force for Vickers micro-hardness testing.

36 MATERIALS SCIENCE↗

Criteria for initiation of delamination in quasi-static punch-shear tests of a carbon-fiber composite material.

V arious phenomenological delamination initiation criteria are analyzed in quasi - static punch - shear tests conducted on six different geometries. These six geometries are modeled and analyzed using elastic, large - deformation finite element analysis. Analysis output is post - processed to assess different delamination initiation criteria, and their applicability to each of the geometries. These criteria are compared to test results to assess whether or not they are appropriate based on what occurred in testing. Further, examinations of CT scans and ultrasonic images o f test specimens are conducted in the appendix to determine the sequence of failure in each test geometry.

Chin, Eric Brian↗

Towards Polymer-Free, Femto-Second Laser-Welded Glass/Glass Solar Modules

This project explores the use of femto-second (fs) lasers to form glass-to-glass welds for hermetically sealed, polymer-free solar modules. Low iron solar glass coupons were welded together without the use of glass filler using a fs laser with dedicated optics to elongate the focal plane parallel to the incident beam. The resulting welds were then stress tested to failure to reveal the critical stress intensity factor, KIc. These values were used in a structural mechanics model of a 1 m by 2 m glass/glass module under a simulated static load test. The results show that the fs laser welds are strong enough for a suitably framed module to pass the IEC 61215 static load test with a load of 5400 Pa. Key to this finding is that the module must be framed and braced, and the glass must be ribbed to allow pockets for the cells and welds inside the border of the module. The result is a module design that is completely polymer-free, hermetically sealed, has improved thermal properties, and is easily recycled.

femto-second laser welded↗

Dynamic and quasi-static measurements of C-4 and primasheet P1000 explosives

We have measured dynamic and quasi-static mechanical properties of C-4 and Primasheet P1000 explosive materials to provide input data for modeling efforts. Primasheet P1000 is a pentaerythritol tetranitrate-based rubberized explosive. C-4 is a RDX-based moldable explosive. Dynamic measurements included acoustic and split-Hopkinson pressure bar tests. Quasi-static testing was done in compression on load frames and on a dynamic mechanical analyzer. Split-Hopkinson and quasi-static tests were done at five temperatures from -50 C to 50 C. Acoustic velocities were measured at, above, and below room temperature.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Determination of Johnson–Cook Plasticity Model Parameters for Inconel718

In order to simulate foreign object damage (FOD) phenomenon in aircraft high-pressure compressor blades made of a nickel-based super-alloy, Johnson–Cook (J–C) plasticity model was used. For prediction of material’s plastic behavior at temperature of 400 °C (working temperature of the blades) in the range of strain rates associated with the FOD phenomenon (in order of 10{sup 6} s{sup −1}), material parameters of A, B, C, n and m for the J–C plasticity model had to be determined experimentally. Parameters of A, B and n with values of 1108, 699 MPa and 0.5189, respectively, were obtained from quasi-static tensile tests. Moreover, m was determined to be 1.2861, also through quasi-static tensile tests with a strain rate of 1 s{sup −1} at three temperatures of 475, 550 and 625 °C. However, in order to determine C, firstly a steel ball was impacted on the surface of a flat specimen made of a precipitation-hardening alloy, and then, the impact site was 3D scanned to obtain the induced crater profile. Finally, the impact test (ballistic) was simulated using Abaqus, and a C value of 0.0085 was determined by comparing the actual crater profile with the one obtained from the simulation through a trial-and-error approach.

36 MATERIALS SCIENCE↗

Application of the immobilized low-activity waste glass corrosion model to the static dissolution of 24 statistically-designed alkali-borosilicate waste glasses

Glass corrosion models that capture the complex mechanisms of the glass-water reaction enable the prediction of nuclear waste glass durability in disposal scenarios. Parameterization of such models is challenging because of the need to capture changes in corrosion behavior with time, reaction conditions, and glass composition. In this report we describe and employ the immobilized low activity waste (ILAW) glass corrosion model (IGCM) in geochemical simulations of static dissolution tests, at two temperatures (40 °C and 90 °C), for a matrix of 24 enhanced low activity waste (eLAW) glasses statistically designed to cover a processable composition space defined by 8 major glass components (Al 2 O 3 , B 2 O 3 , CaO, Na 2 O, SiO 2 , SnO 2 , ZrO 2 , and Others as defined in the text). The IGCM includes a first-order chemical affinity term and an ion-exchange term that represents the net exchange of Na+ ions in the pristine glass with protons in aqueous solution. Constant, time-dependent, and time- and pH-dependent functional forms of the ion-exchange term are evaluated to reproduce the change in corrosion behavior with time in saturated, static dissolution tests. The agreement with measured aqueous concentrations of the main glass components (B, Na, and Si) improved significantly upon addition of a time-dependent term, which therefore constitutes a simple representation of the glass-water reaction progress. Due to the limited changes in pH in the static dissolution tests, past a short initial period of rapid increase, addition of a pH dependent term did not appreciably improve the fits, indicating that comprehensive model parameterization requires more than one type of glass corrosion test to capture a wide range of solution chemistries. IGCM parameters were found to be dependent on glass composition, and the parameter sets generated in this work will enable the development of composition–parameter correlation models that offer the promise of predicting IGCM parameters, and thus glass corrosion behavior, solely based on glass composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The estimation of Poisson’s ratio by time-averaging and Cornu’s method for isotropic beams

Prior research suggests that direct static (e.g., uniaxial testing) and dynamic (e.g., ultrasonic wave propagation analysis) measurements differ in the estimation of Poisson’s ratio because anisotropies and heterogeneities in the sample material affect the two types of tests differently. Even assuming isotropic and homogeneous material properties, prior research further suggests that discrepancies between static/dynamic test results will exist because the error of the diagnostic techniques for the measurand are inherently different. Finally, thermodynamic effects are not present in static tests but can significantly affect dynamic test results. Given the potential for all these variables to produce discrepancies, it would be helpful to have the measurement of Poisson’s ratio obtainable from the same theory and experimental measurements by either static or dynamic testing methods. Our finite element calculations show that by combining time-averaged scanning digital holography with Cornu’s method, it is theoretically possible to estimate the effective Poisson’s ratio from the anticlastic contours at the antinode of the first out-of-plane bending mode shape. This is true regardless of frequency and therefore applicable for both static and dynamic measurements. Our results show that the estimate of Poisson’s ratio by Cornu’s method using data from simulations of mode shapes approaches the true value of Poisson’s ratio. Additionally, our research suggests that beam geometry and boundary conditions are fundamental factors limiting the convergence of the estimate of Poisson’s ratio to the true value of Poisson’s ratio regardless of performing a static or dynamic test.

42 ENGINEERING↗

Summary Report: Glass-Ceramic Waste Forms for Combined Fission Products

Glass-ceramic waste form development began in FY 2010 examining two combined waste stream options: (1) alkaline earth (CS) + lanthanide (Ln), and (2) + transition metal (TM) fission-product waste streams generated by the uranium extraction (UREX+) separations process. Glass-ceramics were successfully developed for both options however; Option 2 was selected over Option 1, at the conclusion of 2010, because Option 2 immobilized all three waste streams with only a minimal decrease in waste loading. During the first year, a series of three glass (Option 2) were fabricated that varied waste loading-WL (42, 45, and 50 mass%) at fixed molar ratios of CaO/MoO{sub 3} and B{sub 2}O{sub 3}/alkali both at 1.75. These glass-ceramics were slow cooled and characterized in terms of phase assemblage and preliminary irradiation stability. This fiscal year, further characterization was performed on the FY 2010 Option 2 glass-ceramics in terms of: static leach testing, phase analysis by transmission electron microscopy (TEM), and irradiation stability (electron and ion). Also, a new series of glass-ceramics were developed for Option 2 that varied the additives: Al{sub 2}O{sub 3} (0-6 mass%), molar ratio of CaO/MoO{sub 3} and B{sub 2}O{sub 3}/alkali (1.75 to 2.25) and waste loading (50, 55, and 60 mass%). Lastly, phase pure powellite and oxyapatite were synthesized for irradiation studies. Results of this fiscal year studies showed compositional flexibility, chemical stability, and radiation stability in the current glass-ceramic system. First, the phase assemblages and microstructure of all of the FY 2010 and 2011 glass-ceramics are very similar once subjected to the slow cool heat treatment. The phases identified in these glass-ceramics were oxyapatite, powellite, cerianite, and ln-borosilicate. This shows that variations in waste loading or additives can be accommodated without drastically changing the phase assemblage of the waste form, thus making the processing and performance characteristics of the waste form more predictable/flexible. However, in the future, the glass phase still needs to be accurately characterized to determine the effects of waste loading and additives on the glass structure. Initial investigations show a borosilicate glass phase rich in silica. Second, the normalized concentrations of elements leached from the waste form during static leach testing were all below 0.6 g/L after 28d at 90 C, by the Product Consistency Test (PCT), method B. These normalized concentrations are on par with durable waste glasses such as the Low-Activity Reference Material (LRM) glass. The release rates for the crystalline phases (oxyapatite and powellite) appear to be lower (more durable) than the glass phase based on the relatively low release rates of Mo, Ca, and Ln found in the crystalline phases compared to Na and B that are mainly observed in the glass phase. However, further static leach testing on individual crystalline phases is needed to confirm this statement. Third, Ion irradiation and In situ TEM observations suggest that these crystalline phases (such as oxyapatite, ln-borosilicate, and powellite) in silicate based glass ceramic waste forms exhibit stability to 1000 years at anticipated doses (2 x 10{sup 10}-2 x 10{sup 11} Gy). This is adequate for the short lived isotopes in the waste, which lead to a maximum cumulative dose of {approx}7 x 10{sup 9} Gy, reached after {approx}100 yrs, beyond which the dose contributions are negligible. The cumulate dose calculations are based on a glass-ceramic at WL = 50 mass%, where the fuel has a burn-up of 51GWd/MTIHM, immobilized after 5 yr decay from reactor discharge.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CFD modeling and simulation for corrosive wear of refractory in molten slag

The development of high-wear resistant refractories having minimal production costs is facilitated by characterizing the wear mechanisms associated with their corrosive wear. Static cup testing is a commonly used method for comparing the corrosion resistance performance of two or more refractory materials. Although the static cup test conditions are not as severe as dynamic tests, this study shows that the thermal gradient present within the system during heating and cooling stages serves to generate movement of the slag leading to mechanical wear. The thermal gradient within the refractory, and between the slag and the refractory, occurs during the ramp stage of the test and lasts until the soaking stage is reached bringing the system to a thermal equilibrium. Using computational fluid dynamics (CFD) capabilities embedded within ANSYS software, this study modelled and quantified the convection currents within the slag and associated shear stresses generated on the refractory walls due to the thermal gradient. A traditional ladle furnace was employed as a case study to verify the results of the studied CFD model. The corrosion rate of the refractory lining was found to depend on the mass transfer coefficient of the refractory dissolution into the slag, and a velocity term which governs the extent of corrosion at any given location. This velocity term is a function of slag viscosity, as well as the concentration gradient and/or temperature gradient at the triple points. In this study, wall shear stress was used as a reliable proxy for identifying high-velocity regions prone to excessive corrosive wear. Elevated wall shear stress near the slag/air and slag/molten steel interfaces align with observed corrosion grooves, which reflects the intensified corrosive wear at these locations.

Ramteke, Rajat Rajat Durgesh Ramteke [University o↗