Search NASA⌕ Search

SEARCH · Search NASA

Results for “stock modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

South Africa’s Appliance Energy Efficiency Standards and Labeling Program

Electricity consumption in South Africa comes with a hefty environmental cost to the society. For every kilowatt-hour (kWh) produced, 1 kilogram (kg) of carbon dioxide (CO 2 ) is emitted, 1.4 liters of water are used, and 0.37 grams of particulate emissions are released in the atmosphere. These environmental implications result from the large share of electricity produced from coal (91 percent in 2015). While planned new capacity will ramp up renewable energy, the integrated resource plan for the country still projects the share of col to be 64 percent in 2030. Energy savings provide environmental benefits as well as economic benefits. Energy efficiency standards and labeling (S&L) programs are a policy measure proven to save energy. Such programs have been implemented in many countries to remove inefficient technologies and transform markets to more efficient technologies. In this study, we describe the methodology, assumptions and results of a stock turnover modeling tool that estimates the energy savings achievable by South Africa’s S&L program in the residential sector. We show that if regulations are passed in 2020 and effective in 2021 for 10 major end-use adopting international standards best practices, 6 terawatt-hours (TWh) will be saved in 2030 and 9.5 TWh will be saved in 2040, representing a CO 2 mitigation of 3.7 megatonnes (Mt) in 2030 and 5.8 Mt in 2040, which will contribute to the South African government’s international engagement in fighting against climate change through its National Determined Contribution (NDC). Additional environmental benefits include saving of 6.5 billion liters of water in 2030, representing approximately 100 liters per capita in 2030. Air quality will also improve, as 4 kilotons (kt) of particulate emissions will be avoided, as well as 4.3 Mt of sulfur oxides (SOx) and 23 kt of nitrogen oxides (NOx) in 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Photovoltaics With 40% Rooftop Coverage

This study investigates the impact of adding 40% rooftop coverage of photovoltaics to the U.S. commercial building stock. Panels are modeled as higher performance with 21% rated efficiency, 96% inverter efficiency, 1.10 DC/AC ratio,14% system losses, and azimuth/tilt angles that vary by location. Total panel area is modeled at 40% of the roof area for each model. Total rated PV power for a building is based on the calculated total panel area and the assumed efficiency of 21%. This measure is applied to all buildings modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Natural Gas Demand Response Potential during Extreme Cold Events in Electricity-Gas Coupled Energy Systems

In regions where natural gas is used for both power generation and heating buildings, extreme cold weather events can place the electrical system under enormous stress and challenge the ability to meet residential heating and electric demands. Residential demand response has long been used in the power sector to curtail summer electric load, but these types of programs in general have not seen adoption in the natural gas sector during winter months. Natural gas demand response (NG-DR) has garnered interest given recent extreme cold weather events in the United States; however, the magnitude of savings and potential impacts—to occupants and energy markets—are not well understood. We present a case-study analysis of the technical potential for residential natural gas demand response in the northeast United States that utilizes diverse whole-building energy simulations and high-performance computing. Our results show that NG-DR applied to residential heating systems during extreme cold-weather conditions could reduce natural gas demand by 1–29% based on conservative and aggressive strategies, respectively. This indicates a potential to improve the resilience of gas and electric systems during stressful events, which we examine by estimating the impact on energy costs and electricity generation from natural gas. We also explore relationships between hourly indoor temperatures, demand response, and building envelope efficiency.

03 NATURAL GAS↗

Surfaces and interfaces of glass and ceramics; Proceedings of the International Symposium on Special Topics in Ceramics, Alfred University, Alfred, N.Y., August 27-29, 1973

The characterization of surfaces and interfaces is considered along with the infrared spectra of several N-containing compounds absorbed on montmorillonites, applications of surface characterization techniques to glasses, the observation of electronic spectra in glass and ceramic surfaces, a method for determining the preferred orientation of crystallites normal to a surface, and the friction and wear behavior of glasses and ceramics. Attention is given to the wear behavior of cast surface composites, an experimental investigation of the dynamic and thermal characteristics of the ceramic stock removal process, a dynamic elastic model of ceramic stock removal, and the structure and properties of solid surfaces. Individual items are announced in this issue.

Frechette, V. D.↗

End-Use Savings Shapes Measure Documentation: Demand Control Ventilation

This documentation focuses on a single end-use savings shape measure - Demand Control Ventilation (DCV). DCV can save energy by reducing the rate at which outdoor air (OA) is delivered during periods of less-than-design occupancy. This measure will enable DCV for air loops using applicable HVAC system types (all except dedicated outdoor air systems [DOAS], packaged systems, or that have an energy recovery ventilator [ERV]) and serving applicable space types (all except kitchens, dining areas, patient spaces, mechanical rooms, stairwells and corridors, or high exhaust space types) using model occupancy schedules to control the DCV. The measure is applicable to 72.7% of the stock floor area. As office buildings outside of California in ComStock are modeled using a single, whole-building space type, DCV is not applied to these building types. The DCV measure demonstrates 2.6% total site energy savings (119 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing process-based models to predict current and future soil organic carbon stocks at high-resolution

From hillslope to small catchment scales (< 50 km 2 ), soil carbon management and mitigation policies rely on estimates and projections of soil organic carbon (SOC) stocks. Here we apply a process-based modeling approach that parameterizes the MIcrobial-MIneral Carbon Stabilization (MIMICS) model with SOC measurements and remotely sensed environmental data from the Reynolds Creek Experimental Watershed in SW Idaho, USA. Calibrating model parameters reduced error between simulated and observed SOC stocks by 25%, relative to the initial parameter estimates and better captured local gradients in climate and productivity. The calibrated parameter ensemble was used to produce spatially continuous, high-resolution (10 m 2 ) estimates of stocks and associated uncertainties of litter, microbial biomass, particulate, and protected SOC pools across the complex landscape. Here, subsequent projections of SOC response to idealized environmental disturbances illustrate the spatial complexity of potential SOC vulnerabilities across the watershed. Parametric uncertainty generated physicochemically protected soil C stocks that varied by a mean factor of 4.4 × across individual locations in the watershed and a – 14.9 to + 20.4% range in potential SOC stock response to idealized disturbances, illustrating the need for additional measurements of soil carbon fractions and their turnover time to improve confidence in the MIMICS simulations of SOC dynamics.

54 ENVIRONMENTAL SCIENCES↗

End-Use Load Profiles for the U.S. Building Stock

The End-Use Load Profiles for the U.S. Building Stock project uses New ResStock and ComStock models to statistically represent the energy use of U.S. buildings. The project's hybrid approach combines best-available ground truth data, such as submetering studies and statistical disaggregation of whole-building interval meter data, with the reach, cost-effectiveness, and granularity of physics-based and data-driven building stock modeling to deliver a nationally-comprehensive data set at a fraction of the historical cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical relationships between environmental factors and soil organic carbon produce comparable prediction accuracy as the Machine Learning

Accurate representation of environmental controllers of soil organic carbon (SOC) stocks in Earth System Model (ESM) land models could reduce uncertainties in future carbon-climate feedback projections. Using empirical relationships between environmental factors and SOC stocks to evaluate land models can help modelers understand prediction biases beyond what can be achieved with the observed SOC stocks alone. In this study, we used 31 observed environmental factors, field SOC observations (n = 6,213) from the continental US, and two Machine Learning approaches [Random Forest (RF) and Generalized Additive Modeling (GAM)] to (1) select important environmental predictors of SOC stocks, (2) derive empirical relationships between environmental factors and SOC stocks, and (3) use the derived relationships to predict SOC stocks and compare the prediction accuracy of simpler model developed with the machine learning predictions. Out of the 31 environmental factors we investigated, 12 were identified as important predictors of SOC stocks by the RF approach. In contrast, the GAM approach identified six (of those 12) environmental factors as important controllers of SOC stocks: potential evapotranspiration, normalized difference vegetation index, soil drainage condition, precipitation, elevation, and net primary productivity. The GAM approach showed minimal SOC predictive importance of the remaining six environmental factors identified by the RF approach. Our derived empirical relations produced comparable prediction accuracy as the GAM and RF approach using only a subset of environmental factors. The empirical relationships we derived using the GAM approach can serve as important benchmarks to evaluate environmental control representations of SOC stocks in ESMs, which could reduce uncertainty in predicting future carbon-climate feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Impact Analysis of Transitioning to Heat Pump Rooftop Units for the U.S. Commercial Building Stock

Twenty percent (25%) of the energy consumed by the U.S. commercial building sector is from on-site combustion of fossil fuels for space heating. Part of decarbonizing U.S. energy systems to meet climate initiatives will require electrification of space heating equipment, often by transitioning to heat pumps. Rooftop units (RTU) are the most prominent commercial building HVAC system type and should therefore be prioritized for electrification solutions. However, there is limited understanding of the impact on emissions when considering regional electricity generation methods, as well as the impact of ambient temperature on capacity and efficiency, defrost operation, realistic sizing methodologies, and supplementary heating on overall heat pump performance. This study explores the effects of transitioning all installed, existing RTUs to high-performance heat pump RTUs for the U.S. commercial building stock. The analysis is performed using ComStock (TM), the U.S. Department of Energy's calibrated model of the U.S. commercial building stock. Results show 10% and 9% reductions in stock aggregate energy consumption and greenhouse gas emissions, respectively. This analysis will help inform the transition to heat pump RTUs for the U.S. commercial building stock.

commercial building↗

Modeling the Effects of Global Change on Ecosystem Processes in a Tropical Rainforest

Ongoing land-use change and climate change in wet tropical forests can potentially drive shifts in tree species composition, representing a change in individual species within a functional group, tropical evergreen trees. The impacts on the global carbon cycle are potentially large, but unclear. We explored the differential effects of species within this functional group, in comparison with the effects of climate change, using the Century model as a research tool. Simulating effects of individual tree species on biome-level biogeochemical cycles constituted a novel application for Century. Background and Objectives: A unique, long-term, replicated field experiment containing five evergreen tree species in monodominant stands under similar environmental conditions in a Costa Rican wet forest provided data for model evaluation. Our objectives were to gain insights about this forest’s biogeochemical cycles and effects of tree species within this functional group, in comparison with climate change. Materials and Methods: We calibrated Century, using long-term meteorological, soil, and plant data from the field-based experiment. In modeling experiments, we evaluated effects on forest biogeochemistry of eight plant traits that were both observed and modeled. Climate-change simulation experiments represented two climate-change aspects observed in this region. Results: Model calibration revealed that unmodeled soil processes would be required to sustain observed P budgets. In species-traits experiments, three separate plant traits (leaf death rate, leaf C:N, and allocation to fine roots) resulted in modeled biomass C stock changes of >50%, compared with a maximum 21% change in the climate-change experiments. Conclusions: Modeled ecosystem properties and processes in Century were sensitive to changes in plant traits and nutrient limitations to productivity. Realistic model output was attainable for some species, but unusual plant traits thwarted predictions for one species. Including more plant traits and soil processes could increase realism, but less-complex models provide an accessible means for exploring plant-soil-atmosphere interactions.

54 ENVIRONMENTAL SCIENCES↗